Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.8 L+₹1.0 L (4.08%)Rejected-Finance H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹25.9 L+₹1.1 L (4.60%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹27.0 L+₹2.2 L (8.92%)Rejected-Finance D 1 A 72 UPPER GROUND FLOOR JANAK PURI JAI ROAD NEW DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹27.9 L+₹3.1 L (12.5%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹61,000
Closing Date
11 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE No 2 Delhi Cantt
CWE No 2 Delhi Cantt-10
PROVN OF PASSENGER LIFT FOR CGOM SECTOR -24 NOIDA UNDER AGE (I) CG NOIDA
2021_MES_428079_2
CWE/NOIDA-23/2020-21
Open Tender
Miscellaneous Works
Item Rate
1170 days
Sector 24 Noida
As per tender Documents
8 documents required · 8 mandatory
₹500
AGE (I) CG Noida
₹61,000
Yes
10 Jun 2021
10 Apr 2021
13 May 2021
10 Apr 2021
11 May 2021
28 Apr 2021
60 days
Amount
Phase-I Design, Supply ,install, testing and commissioning of eletrically operated passenger lift of capacity 8 passenger lift (544 kgs Capacity) in the existing lift well, 1.5 m/s speed with automatic GIEN micro stroke button control, micoprocessor based controller, simplex full collective control suitable for 3 phase, 50 HZ 415 volts AC supply independent operation with AC variable voltage variable frequency(AC VVVF) control closed loop with power saving regenerative drive with suitable gearless motor unit to serve ground plus four upper floors i.e with 5 stops and 5 landings with or with out attendent suitable for synchronised operation automatic power operated centre opening sliding stainless steel door with Rose Golden Mirror finish of 16 gauge with infra-red sensors all along the height for car door with automatic rescue/levelling device (ARD) (with + or -5 mm) with suitable dry maintenance free batteries,haul position digital indicators in car and all landing with call indicating lights etc including necessary joists and beams for mounting machine in the machine room including all civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following : (Size of well available is 2100 mm x 1800 mm ) Make: (i) M/s Otis Elevator Company India Ltd. (ii) M/s Mistubishi Elevator India Pvt Ltd. (iii) M/s Kone India (iv) M/s Hitachi Lift India Pvt Ltd. (v) M/s Thysen krupp Elevator India Pvt Ltd. (vi) M/s Omega Elevators
(a) Fire man switch. (b) Automatic rescue device (A.R.D) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. (c) Battery operated emergency light (LED ceiling fitting ), alarm (speaker for emrgency alarm system to be fixed) and stop buttion in car with rechargeable arrangement for battery .
(d) Integrated Roof RL20 Stainless Steel Ring Lighting LED (e) One sleek circular PVC heavy duty fan in false ceiling. Make for (c) and (d) : Philips/ Bajaj / Havells / Crompton Greaves. (f) Aluminium chequered plate (3mm thick) as flooring joint in chequered plate should not more than one and top covering with 20 mm Recess & Granite Stone.Car skirting material: Brushed stainless SUS304 (g) Non stop button /independent operation (h) Over load warning indicator both audio and visual type with tripping system having relays etc (overload protection/tripping system). (j) Front landing door of stainless steel Rose golden mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. (k) Car size shall be in confirmity with IS -3534-1976 and body to be stainless steel of 16 gauge rose gold mirror finish with stainless steel hand rail 38mm hairline finish (l) Limit switches as specified in IS
(m) Mirror of 6mm thickness of suitable size. (n) Hand rail 38mm hairline finish. (o) Opening with see through glass of 8 mm thick 200 x 600 mm size in all the doors (Car/Landing doors) (p) Specification plate with complete details. (q) Continuous earthing for machine and equipments. (r) Steel Wire rope of adequate size as per relevent IS and as per manufacturer specification
(s) Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards ,buffers, gear unit brakes, control panel ,locks ,governor ,car operational panel,power, control and trailing cables complete. (t) Car operating Panel 1 Full Height Dark grey brushed StSt Tempering glass Segmented LCD display Round flush mounted – stylish touch panel Landing Signalization-Tempered glass Segmented LCD display Flush Mounted Tempered glass Round flush mounted - stylish touch panel (u) Main drives and control shall be of latest , high effective and low power consumption. (v) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. (w) Over load and floor announcement audio and visual arrangement.
Features Common to Specifications 1. Digital Direction & Position Indicator in Car and at all landings 2. Emergency Alarm at the main landing 3. Facia Plate 4. 2 Phase Fireman Drive, Fireman’s switch at the main landing. (In case Fireman Drive is activated the elevator will come to the main landing and open the door). 5. Advanced door operation (Ensures smooth opening & closing of the doors at adjustable door speed) 6. Additional Pressure Sensing Device 7. Load Weighing Device (Audio visual over load indicator in the car for better safety) 8. Full Height Infra-Red Curtain 9. Pit Ladder 10. Emergency Light, Intercom and Alarm with Maintenance Free Rechargeable Battery operation.
11. +6% to -10% Volt. Fluctuation Withstand Capacity 12. Over speed governor (Electro-mechanical device that prevents free fall in case the elevator is travelling at speed more than 10% of the rated speed in downward direction) 13. Automatic Rescue Device (To rescue the passengers in case of emergency- this device will bring the car to the nearest floor automatically and will open the doors). 14. Steel Ropes 15. Special Car Door Lock 16. Fire Rated Doors-2 hour. 17. Automatic Brake Testing. 18. PMS MOTOR with ECO Disk Drive 19. Linear Motor Technology & Close Loop Arrangement. 20. 24x7 Connected Services. 21. Car & Landing Doors – Rose Golden Mirror Finish
M & L for earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick burried directly on ground (earth pit not less than 2.25m below ground level) with top edge not less than 1.5m below ground level connected to copper earth lead of size 20 x 3 mm by means of bolts, nuts check nuts, washers of galvanised iron or steel all as shown in electrical plate No 5 of SSR part I, connected to earth test point all as specified or indicated complete with excavation, earth work, PCC 1:3:6 pit with RCC M-25 Design Mix concrete cover 54 cm x 54 cm x 50 mm thick reinforced with hard drawn steel wire fabric weighting exceeding 4 kg/ Sqm with suitable handle made of 10 mm dia iron rod and 25 mm bore and 7.5 mtrs medium grade GI pipe for protection of earth lead, test point. GI funnel with wire mesh all as directed and specified and testing on completion
Supply and fixing copper strip 20mmx3mm buried in ground or fixed to wall complete all as specified.
M&L for test point terminal block made of gun metal or phospourous bronze size 75x72x25mm drilled and screwed including 3nos 8mm dia 25mm long hex head screw complete all as specified and as directed.
Supply, laying and testing XLPE cable PVC insulated heavy duty armoured electric 1100V grade with aluminium conductor,cross sectional area 35 Sqmm 3.5 Core complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of LT UG cables etc. not exceeding 10 sqm on plan and getting out for soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as directed.
Material and labour for Sand cushioning over and below the U/G Cables laid (Total depth of sand shall be 23 cm and compacted to 18 cm) complete all as specified and directed
Material and labour for laying Bricks common burnt clay building bricks sub-class `B’ designation 75 as in protection of UG cable complete all as specified and as directed.
Supply and fix MCB DB TPN 4 way 8+12(I/C+O/G)double door with MCB as incomer complete all as specified and as directed.
Supply and fix MCB 100 Amps capacity 415 volts 4 pole complete all as specified and as directed.
Supply and fix RCBO for earth leakage, overload & short- circuit protection TPN 63 Amps capacity 415 volts 300ma complete all as specified and as directed.
Supply and fix MCB FP 32 Amps complete all as specified and as directed.
Supply and fix MCB DP 16-32 Amps complete all as specified and as directed.
Supply and lay in trenches or fixed to walls GI pipe 40mm dia light grade for cable protection as required at site complete all as specified and as directed.
M & L Point wiring with single core PVC insulated unsheated 1100 Volts grade FR IS 694 cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area) drawn through and incl non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia,fixed on wall (concealed conduit wiring) and on ceiling with GI saddles,GI screws,rawl plugs etc (surface conduit wiring) with all fittings incl tee,junction boxes and provn of pressed steel terminal box 2mm thick of suitable size with 3mm thick plastic laminated sheet cover for mounting switch sockets and regulators/ modular type pressed steel terminal boxes of suitable sizes for modular wiring with PVC white fram where modular switch socket to be fixed/coloured top sheet cover/ frame and drawing continious earth wire and incl PVC insulated unsheated 1100 Volts grade FR IS 694 cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area) connected to earth dolly complete all as specified and directed by Engr-in-charge (for Lift Well)
All as per item No-17.00 here-in-before but for 3 pin 5 amps socket outlet on independent board controlled by one switch complete all as specified and directed.
S & F switch piano, flush type, single pole, one way 6 amp complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin, 6 amp flush type complete all as specified and directed.
LED bulk head luminaries, with lamp holders, etc. complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ
Cutting opening through brick wall built in cement mortar through brick wall for door and removing rubbish off the permises of MOD land complete all as sprcified.
M& L for forming jambs, etc to openings (for foregoing item) with cement mortar 1:4 including cutting, toothing and properly bonding into old brick work also facing, jointing and pointing to match existing work complete.
M & L for making good under cills or heads of opening in cement mortar 1:4 including pingin when necessary complete.
Taking down cement plaster of brick work or concrete surface including raking out joints, hacking for key, scrubbing down with water complete all as specified.
M & L for rendring 15 mm thick in cement mortar 1:4 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Supply only liquid water proofing compound.
M & L for 10 mm thick rendering for backing of granite tiles in cement mortar 1:3 on fair faces of brick work or concrete surfaces complete all as specified and as directed.
M & L for 20 mm thick granite work tiles machine cut, in dado or wall cladding laid over cement screed and jointed with granite epoxy/silicon glue including grinding and polishing complete all as specified and as directed.
M & L for preparation of new plastered or previousely untreated surfaces including brooming down with steel wire brushing removing silt, efflorescence etc and applying 3 coat of white wah on wall complete all as specified and as directed.
Phase-II (i)This phase will start after completion of defect liability period of phase-I (ii) Final bill of this phase prepare separately)
Comprehensive mainenance of electrically operated passenger lifts (1 No) 8 passenger lift (544 Kgs) passengers to serve ground plus four upper floors complete including attending the following services to lifts all as mentioned vide Note-1 complete all as specified and directed :-
First year after expiry of defects liability period
Second year after expiry of defects liability period
Third year after expiry of defects liability period
Note-1 (i) Comprehensive maintenance consists of preventive and breakdown services including repair and replacment of all consumables like topping of gear oils/grease/door rollers/relays/contactors/door belts/gate lock/contacts/PCB's and any hardware including rewinding of motor etc and load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes the following
(ii) Preventive maintaince consists of carrying out routine check by skilled personnel deputed by OEM as specified in Particular specifications and as recommended by Engineer-in-Charge and lubricating to all moving parts,topping up of oils as per Lubrication chart.
(iii) Breakdown maintaince consists of attending to the faults that may occur and carrying out necessary repairs/replacement to electrical control circuits and electrical/mechanical components of the lift that may occur during the operation.
(iv) Fortnightly,monthly,quarterly,halfyearly and yearly maintaince registeres shall be maintained and signed by site engineer and contractor.
(v) Load testing shall be arranged by the contractor to the Lift for whose repairs were carried out as and when directed by Engr-in-charge.
(vi) Any delay in attending breakdown will attract penalty @ Rs 500 for first 8 to 16 Hrs after receiving complain and @Rs 1500 for every 24 Hrs of delay in rectification of complain.
(vii) Payment will be released only after successull completion of maintenance as per schedule described here in before and submission of record signed by all concern persons
Note-2 The contracto has to submit the AMC agreement with the OEM before the completion defect liability period for commencement of Phase- II
Ish Engineers and Contractors
M/s Adhikari construction co.
Choice india
V S BUILDER
Omega Elevators
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .