Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.1 CrAccepted-AOC | ₹1.1 Cr | 1 | Accepted-AOC Being lowest and reasonable rates |
| 2 | 2₹1.2 Cr+₹5.3 L (4.61%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | ₹1.2 Cr+₹5.3 L (4.61%) | 2 | Rejected-Finance Not being lowest tenderer |
| 3 | 3₹1.2 Cr+₹9.9 L (8.65%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹1.2 Cr+₹9.9 L (8.65%) | 3 | Rejected-Finance Not being lowest tenderer |
| 4 | 4₹1.4 Cr+₹24.3 L (21.3%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | ₹1.4 Cr+₹24.3 L (21.3%) | 4 | Rejected-Finance Not being lowest tenderer |
| 5 | 5₹1.4 Cr+₹26.8 L (23.4%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | ₹1.4 Cr+₹26.8 L (23.4%) | 5 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
26 Feb 2022, 6:00 pmClosed
HQ CWE (U) DELHI CANTT
HQ CWE (U) DELHI CANTT
SPL REPAIR OF LT OH LINE CONVERTED TO UG CABLES AT COD JCOS/OR MD ACCN/UNIT LINE AND COD OVAL SURROUNDING AREA, 19 BIHAR JCOS/OR MD ACCN AREA AND UNIT LINE AREA OF AGE (U) E/S NO-I UNDER GE (U) E/S DELHI CANTT-10
2021_MES_482272_2
CWE(U)/D-14/2021-22
Open Tender
Civil Works
Works
180 days
DELHI CANTT-10
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE(U) ELECTRIC SUPPLY
₹1.9 L
Yes
23 Mar 2022
29 Jan 2022
28 Feb 2022
29 Jan 2022
26 Feb 2022
14 Feb 2022
Amount
Dismantling of MS channel or Angle iron or flat iron sections from LT poles complete all as specified and as directed by Engr in charge.
Dismantling of insulators of any type and any size from RCC/PCC poles complete all as specified and as directed by Engr in charge.
Dismantling carefully Old unserviceble ACSR conductor / jumper from LT Pole complete all as specified and as directed by Engr in charge.
Dismantling & Removing carefully Old unserviceble LT cables/ Service cable of size 16 sqmm to 35 sqmm from LT Pole to MCB DB complete all as specified and as directed by Engr in charge.
Supply, installing, testing and commissioning of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement ,of size 450mm x 450mm x 300mm with 4 Nos 200 Amps aluminium bus bar and with 100 Amp MCCB, 4 pole, 25 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level complete all as specified and as directed by Engr in charge.
Supplying, laying, jointing testing and connecting of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes complete all as specified and as directed by Engr in charge:- Note :- Excavation and earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule/BOQ.
16 Sqmm 4 core
25 Sqmm 4 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
400 Sqmm 3.5 core
500 Sqmm single core
Material & Labour for Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.1 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized Iron Strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as specified and as directed by Engr in charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe light grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supply & Fixing KIOSK box weather proof made out of PVC, one piece moulded SMC base and out door pole mounted hinged door size 333 x 233 x 120 mm out side and 300 x 200 x 105mm inside dimensions comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp and 6 Amp MCB SP with base for controlling the street light, FI clamps 30x4 mm with necessary MS nuts bolts and washers including embossing/painting of Danger notice of size not less than 10 cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as directed by Engineer-in-Charge.
Supply drawing, connecting and testing of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting including providing suitable copper lugs complete all as specified and as directed by Engr in charge.
Material & Labour for HDPE pipe suitable for 5 kgf/cm 2 working pressurewith all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed by Engr in charge. of following sizes
50 mm dia
90 mm dia
110 mm dia
Material & Labour for Demolition of road/path/drain etc and concrete in ground floors, RCC/Brick wall as in road/path/drain etc (below or above ground level) complete all as specified and as directed by Engr in charge including removal of distance upto 50 mtr.
Material & Labour for providing cement concrete 1:2:4 type B-2 (using 40 mm grade crushed stone aggregate) 250 mm Thick complete all as specified and as directed by Engr in charge.
Supply & Fixing time switches astro type in having longitude and latitude of Indian cities in memory 415 V three phase 20 Amp rating with 20 Amps, 415 Volts, three pole contactor fitted inside factory made 2mm thick steel enclosure duly powder coated paintcomplete all as specified and as directed by Engr in charge.
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and as directed by Engr in charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and as directed by Engr in charge.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and as directed by Engr in charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and as directed by Engr in charge.
Supply & Fixing sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and as directed by Engr in charge.
Boring of hole under road/pavement/hard standing or any other situation by mannual means upto 0.90 mtr depth from ground level suitable for passing of HDPE pipe 50 to 110 mm bore and making good both ends all complete all as specified and as directed by Engr in charge.
Vijay Electricals
mayur enterprises
Ridhi engineers and builders
MV Engineers And Contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .