REPAIR MAINTENANCE OVERHAULING OF CEILING FAN EXHAUST FANS OF TECH AREA AT 402 AF STN CHAKERI KANPUR
2020_MES_317984_1
8341/E8
Open Tender
Electrical and Maintenance Works
Item Rate
182 days
GE (AF) E/M Chakeri Kanpur
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) E/M Chakeri Kanpur
₹25,000
20 Mar 2020
24 Jan 2020
25 Feb 2020
24 Jan 2020
24 Feb 2020
7 Feb 2020
Amount
Taing down carefully Ceiling fan 1200/1400 mm sweep any size any capacity any sweep including dismentling of blade down rod fan for recognised defects at site or deposit to store complete all as specified and directed. Note : (i) refixing and reconnection etc of ceiling fan due painting /over hauling etc shall be measured and paid separately (ii) Any damage or loss of fan during taking down shall be made good by the contractor at the own cost
Opening up of ceiling fan for examination joint inspection preparation of inventry of each fan assessing listing nature and details for repair /overhauling /providing new lubricating, grease in bearing/bushes, re-assembling, commissioning and testing complete providing nuts, bolts, locking bolts, blades screws, split pin, rubber real, PVC connector, washers whereas Upto 4 Meters height complete all as specified and directed. Note:- All major rerpair such as replacement of Bush, bearing , condensor, shaft, connection wire , winding & painting will be measured & paidunder resepctive items.
--Ditto--- all as per item No. 2 but for Above 4 Meters height - do-
Refixing and testing ceiling fan any size 1200/1400 mm size in position etc excluding Provision of cable from Ceiling fan to Ceiling Rose PVC flexible three core cable of size 23/0.0076 copper conductor ISI marked white in colour complete all as specified and directed Note : cable will be measured and paid separately
S&F in replacement PVC insulated three core wire copper conductor 1100 Volt grade of size 0.5Sqmm complete all as specified and directed.
S&F in Replacement of ball bearing (No 6201, 6202 & 6203) suitable for Ceiling fan 1200mm/1400mm suitable as per site requirements complete all as specified and directed.
M&L for removing of burnt winding from ceiling fan stator of size 1200mm/1400mm sweep and rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete incl transportation to contractor's work shop and bringing back to store and testing complete all as specified and directed.
M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting ceiling fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with capital letter of size 20 mm height and 03 mm width with synthetic enameled black paint for Ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
S&F in Replacement of gun metal bush suitable for ceiling fan as per site requirements complete all as specified and directed.
Supply and fixing condenser with PVC clamp for 4 mfd complete all as specified and directed.
Supply and fixing condenser with PVC clamp for 6 mfd complete all as specified and directed.
Supply & fix PVC canopy of 1200/1400 mm sweep ceiling fan complete all as specified and directed.
Taking down the ceiling fan, remove the down rod, Material and Labour for provisioning of new down rod made out of GI tubing medium grade cutting, threaded and holes drilled both ends (dual arrangement), making holes – 02 Nos, painting with two coats of synthetic enamel white colour paint, fixing the down rod to the fan and re-hanging the fan complete including their electric connections complete all as specified and directed. Note- GI tubing will be measured and paid separately under S&F item here-in-after.
S& F GI tubing 15 mm bore medium grade ISI marked for fixing in item Serial No 13 above complete all as specified and directed.
S& F GI tubing 40 mm bore medium grade ISI marked for fixing on walls including PCC 1:3:6 type C-1 using 20 mm graded stone aggregate block 230x230x150 mm for grouting ends of pipe & all fittings for hanging of Ceiling fans complete all as specified and directed.
M&L for fan hook made out of MS flat 50x6 mm suitably shaped to mount on 40 mm dia GI pipe including welded MS bar 10 mm dia half round shaped & necessary nuts & bolts complete all as specified and directed.
M&L for replacement of celing fan shaft complete of size & quality as per existing complete all as specified and directed.
Material and labour for replacement of U/S stator block made of laminated sheets of size and quality as per existingcomplete all as specified and directed.
Supply and fixing of Outer cover as per existing shape and size complete all as specified and directed.
S&F electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete all as specified and directed.
S&F fan blade set (set of three) made out of aluminium sutaible for 1200 mm sweep ceiling fan, as per exisitng size and guage complete all as specified and directed. Make : As per sample
-- Ditto-- all as per srl item No 21 here-in-before but 1400 mm sweep
Taing down carefully exhaust fan /wall fan /pedestal fan /air circulators any size any capacity any sweep including dismentling of blade down rod fan for recognised defects at site or deposit to store complete all as specified and directed. Note : (i) refixing and reconnection etc of exhaust fan /wall fan /pedestal fan /air circulators due painting /over hauling etc shall be measured and paid separately. (ii) Any damage or loss of fan during taing down shall be made good by the contractor at the own cost
Disconnecting & Taking down Exhaust fan/wall fan/Pedestal fan/ air circulator any make any size from any position at site transporating to MES store Yard & dismantling blades opening the stator and rotor of fan and providing new lubricating, grease in bearing/bushes, reassembling incl providing nuts, bolts, locking bolts, blades screws, split pin, rubber reel, PVC connector, rubber pad, washers whereas required complete all as specified and directed. Note:- All major rerpair such as replacement of Bush, bearing , condensor, shaft, connection wire, winding & painting will be measured & paid separately under supply only items here-in-after
Refixing and testing Exhaust fan/wall fan/Pedestal fan/ air circulator any make any size from any position at site in position etc including Provision of cable from Ceiling fan to Ceiling Rose PVC flexible three core cable of size 23/0.0076 copper conductor ISI Mar white in colour complete all as specified and directed.
S&F in replacement PVC insulated three core wire copper conductor 1100 Volt grade of size 0.5Sqmm complete all as specified and directed.
-Ditto all as per item No 26 but for 1 sqmm -do-
S&F in Replacement of ball bearing suitable for Exhaust fan/wall fan/pedestal fan upto 380mm sweep complete all as specified and directed.
S&F in Replacement of ball bearing suitable for Exhaust fan / pedestal fan / Air circulator 450mm to 600mm sweep complete all as specified and directed.
Material and Labour for removing of burnt windingof Exhaust Fan 9” sweep from exhaust fan/ Air Circulators/ Wall mounted fans/ pedestal fans rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing incl transportation to work shop and bringing back to store and testing for following fans complete all as specified and directed.:-
-- Ditto-- all as per item No. 30 above but for Exhaust Fan 12” sweep.
-- Ditto-- all as per item No. 30 above but for Exhaust Fan 18” sweep.
-- Ditto-- all as per item No. 30 above but for Exhaust Fan 24” sweep.
-- Ditto-- all as per item No. 30 above but for Air circulator Fan 24” sweep.
-- Ditto-- all as per item No. 30 above but forwall mounted fan 16" sweep.
-- Ditto-- all as per item No. 30 above but for pedestal fan 16" sweep.
-- Ditto-- all as per item No. 30 above but for pedestal fan 24 " sweep.
S&F in Replacement of gun metal bush suitable for pedestal fan/ exhaust fan all as per site requirements complete all as specified and directed.
Supply and fixing capacitors with PVC clamp of the 4 MFD complete all as specified and directed.
Supply and fixing capacitors with PVC clamp of the 6 MFD complete all as specified and directed.
Supply and fixing the revolving mechanism of wall mounted fan suitable for 400 mm sweep or as per existing type complete all as specified and directed.
Supply and fixing the stator block of wall mopunted fan as per existing design and material suitable for 400 mm sweep complete all as specified and directed.
Supply and fixing the rotor block as per existing suitable for 400 mm sweep wall mounted fan complete all as specified and directed.
M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting of exhaust fan/air circulator fan/pedestal fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with capital letter of size 20 mm height and 03 mm width with synthetic enameled black paint for Exhaust Fan 9”/12" sweep complete all as specified and directed.
-- Ditto-- all as per Item No. 44 above but Exhaust Fan 24” sweep single phase/ three phase.
-- Ditto-- all as per Item No. 44 above but Air Circulators 24” sweep single phase/ three phase.
-- Ditto-- all as per Item No. 44 above but Pedestal Fan 16 " sweep single phase/ three phase.
-- Ditto-- all as per Item No. 44 above but Pedestal Fan 24 " sweep single phase/ three phase.
-- Ditto-- all as per Item No. 44 above but exhaust Fan 18 " sweep single phase/ three phase.
Material and Labour for making circular holes suitable for fixing of 18” sweep Exhaust fans by cutting the wall any thickness/ required circumstances for exhaust of air and including grouting of rag bolts and nuts complete including finishing of disturbed surfaces by using cement mortar 1:3 complete all as specified and directed.
-- Ditto -- all as per item No 50 above but suitable for 12” sweep exhaust fan.
Supply and fixing in replacement of celling fan sweep suitable for 1200/1400 mm sweep fan complete all as specified and directed.
S&F in replacement exhaust fan of MS blade size 12” to 15” complete all as specified and directed.
S&F in replacement exhaust fan of MS blade size 18” to 24” complete all as specified and directed.
S&F in replacement pedestal fan of MS blade size 16” to 24” as per existing complete all as specified and directed.
M&L for MS front frame suitable for mounting of stays of 9" exhaust fan made out of MS Sheet not less than 1.6mm thick painted with two coat of synthetic enamelled over a coat of red oxide primer complete with neccesarry fixing accessories such as nut, bolts washers etc & fixing to wall all as per existing & site requirement including taking down old unserviceable complete all as specified and directed.
--Ditto- all as per item No 56 but suitable for 12" exhaust fan -do-
--Ditto- all as per item No 56 but suitable for 18" exhaust fan -do-
--Ditto- all as per item No 56 but suitable for 24" exhaust fan -do-
M&L for MS stay work (set of 4) suitable for 9" exhaust fan made out of not less than 20 x 3mm MS strip bent to shape complete painted with two coat of synthetic enamelled over a coat of red oxide primer complete with neccesarry fixing accessories such as nut, bolts washers etc & fixing to wall all as per existing & site requirement including taking down old unserviceable complete all as specified and directed.
-Ditto-- all as per item No 60 but suitable for 12" exhaust fan made out of not less than 25 x 4mm MS strip -do-
-Ditto-- all as per item No 60 but suitable for 18" exhaust fan made out of not less than 25 x 4mm MS strip -do-
-Ditto-- all as per item No 60 but suitable for 24" exhaust fan made out of not less than 25 x 5mm MS strip -do-
M&L for circular / rectangular framed shutters suitable for 9" exhaust fan made out of MS sheet not less than 1 mm thick for frame & not less than than 0.6mm thick for shutter painted with two coat of synthetic enamelled over a coat of red oxide primer complete with neccesarry fixing accessories all as per existing & as per site requirement complete all as specified and directed.
-Ditto- all as per item No 64 but suitable for 12" exhaust fan -do-
-Ditto- all as per item No 64 but suitable for 18" exhaust fan -do-
-Ditto- all as per item No 64 but suitable for 24" exhaust fan -do-
M&L for replacement of exhaust fan shaft complete of size & quality as per existing complete all as specified and directed.
ashokcontractors
BRIGHT TRADRES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .