Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAdmitted-Finance | ₹2.4 L | L1 | Admitted-Finance |
| 2 | L2₹2.4 L+₹6,490 (2.76%)Admitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | ₹2.4 L+₹6,490 (2.76%) | L2 | Admitted-Finance |
| 3 | L3₹2.5 L+₹16,638 (7.07%)Admitted-Finance CW 545 SANJAY GANDHI TRANSPORT NAGAR NEW DELHI 110042 | NORTH | DELHI | 110042 | ₹2.5 L+₹16,638 (7.07%) | L3 | Admitted-Finance |
| 4 | L4₹2.6 L+₹24,036.60 (10.2%)Admitted-Finance PROP NO A 80 FIRST FLOOR FLAT NO 3 CHATTAR PUR ENCLAVE PHASE 2 NEW DELHI SOUTH WEST DELHI DELHI 110074 | SOUTH DELHI | DELHI | 110074 | ₹2.6 L+₹24,036.60 (10.2%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SONI SALES and SERVICE L1 | Premier Engineering Company L2 | M G Traders and Engineers L4 | Devraj Enterprises L3 |
|---|---|---|---|---|---|---|---|
| 1.01 | Dismantling of the Automation panel starter & Automatic rotor controller, removing of cable connection, logic control unit, sensing lead from sump by skilled technical person at site. | 1 | Job | 9,500 ₹11,210 | 7,500 ₹8,850 Lowest | 7,850 ₹9,263 | 10,200 ₹12,036 |
| 1.02 | Repairing of Automatic rotor resistance unit & panel unit for operation of 75 HP motor pump set by replacing following items with new:-
a) Digital cyclic timer-1 Nos.
b) Sump Sensor with prob -1No
c) Auxiliary Relay2 No+2NC – 2Nos.
d) Auto manual selector switch with keys; 1 No.
e) Phase failure relay-1No
f) Power contactor 220V-2 Nos.
g) 80 Amp TP -1No.
h) Aluminum bus bar 500 Amp.
i) Control wiring 2.5/1.5 sqmm-20 mtr.
j) Power wiring 25 sq mm-20 mtr.
k)100 Amp MCCB 36KA 3 pole -1No.
l) TP MCB 16 Amp – 1 No.
m) Resistance set in resistance wire (URIKA WIRE) on porcine tube -12 Nos.
n) On delay timer -1No, off/trip indication -1set
o) volt meter with VSS-1 No.
p) Ampere meter with ASS-1No.
q) Temperature meter with sensor-1No
r) CT 400/5-2 Nos
s) Control MCB 6 Amp – 4 Nos
Repairing of automatic phase sequence corrector -1Job
Components make: L&T/Minelec/Finolex | 1 | Job | 1,30,000 ₹1,53,400 Lowest | 1,59,500 ₹1,88,210 | 1,70,200 ₹2,00,836 | 1,35,000 ₹1,59,300 |
| 1.03 | Making control wiring through copper wire 2.5 sq mm with thimble /ferrule as per site requirement. | 1 | Job | 11,000 ₹12,980 | 7,500 ₹8,850 Lowest | 7,720 ₹9,109.6 | 12,400 ₹14,632 |
| 1.04 | Re- fitting of above components & installation of system on site & making Cable connection with thimble /tapping etc. | 1 | Job | 6,500 ₹7,670 Lowest | 12,500 ₹14,750 | 13,100 ₹15,458 | 8,500 ₹10,030 |
| 1.05 | Automation programming by PLC & GSM module with SMPS & synchronizing operation & indication as per command given. | 1 | Job | 28,500 ₹33,630 | 15,000 ₹17,700 Lowest | 17,500 ₹20,650 | 32,000 ₹37,760 |
| 1.06 | Testing & commissioning of the installed equipment’s, testing of the panel prior to switching on as follow
i)Continuity and earth testing
ii) Meggaring of all equipment’s for phase to phase, neutral to body, neutral to earth and phase to earth. | 1 | Job | 14,000 ₹16,520 | 3,000 ₹3,540 Lowest | 3,500 ₹4,130 | 15,500 ₹18,290 |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
1 Jul 2026, 3:00 pmClosed
EE SDW V
Ring Road Andrews Ganj New Delhi 110049
Repair Renovation of Rotor Resistance Control System of Pump Sets No.2 installed at Tughlkabad Extn SPS
2026_DJB_294373_19
N.I.T. No. 05 2026 27
Open Tender
Miscellaneous Works
Works
30 days
Ring Road Andrews Ganj New Delhi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹5,000
8 Jul 2026
25 Jun 2026
1 Jul 2026
25 Jun 2026
1 Jul 2026
25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Dismantling of the Automation panel starter & Automatic rotor controller, removing of cable connection, logic control unit, sensing lead from sump by skilled technical person at site. | 1 | Job | 80 | ₹80 |
| 1.02 | Repairing of Automatic rotor resistance unit & panel unit for operation of 75 HP motor pump set by replacing following items with new:-
a) Digital cyclic timer-1 Nos.
b) Sump Sensor with prob -1No
c) Auxiliary Relay2 No+2NC – 2Nos.
d) Auto manual selector switch with keys; 1 No.
e) Phase failure relay-1No
f) Power contactor 220V-2 Nos.
g) 80 Amp TP -1No.
h) Aluminum bus bar 500 Amp.
i) Control wiring 2.5/1.5 sqmm-20 mtr.
j) Power wiring 25 sq mm-20 mtr.
k)100 Amp MCCB 36KA 3 pole -1No.
l) TP MCB 16 Amp – 1 No.
m) Resistance set in resistance wire (URIKA WIRE) on porcine tube -12 Nos.
n) On delay timer -1No, off/trip indication -1set
o) volt meter with VSS-1 No.
p) Ampere meter with ASS-1No.
q) Temperature meter with sensor-1No
r) CT 400/5-2 Nos
s) Control MCB 6 Amp – 4 Nos
Repairing of automatic phase sequence corrector -1Job
Components make: L&T/Minelec/Finolex | 1 | Job | 80 | ₹80 |
| 1.03 | Making control wiring through copper wire 2.5 sq mm with thimble /ferrule as per site requirement. | 1 | Job | 80 | ₹80 |
| 1.04 | Re- fitting of above components & installation of system on site & making Cable connection with thimble /tapping etc. | 1 | Job | 80 | ₹80 |
| 1.05 | Automation programming by PLC & GSM module with SMPS & synchronizing operation & indication as per command given. | 1 | Job | 80 | ₹80 |
| 1.06 | Testing & commissioning of the installed equipment’s, testing of the panel prior to switching on as follow
i)Continuity and earth testing
ii) Meggaring of all equipment’s for phase to phase, neutral to body, neutral to earth and phase to earth. | 1 | Job | 80 | ₹80 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
BOQ_391401.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .