| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹39.9 L+₹3.3 L (8.94%)Rejected-AOC E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L2 | Rejected-AOC Neither lowest nor competitive | |
| 3 | L3₹40.5 L+₹3.9 L (10.5%)Rejected-AOC B 12 BASEMENT PLOT NO 19 RETAIL BUSINESS CENTRE ADITYA COMPLEX NANGAL RAYA SOUTH WEST NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-AOC Neither lowest nor competitive | |
| 4 | L4₹42.3 L+₹5.7 L (15.4%)Rejected-AOC WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L4 | Rejected-AOC Neither lowest nor competitive | |
| 5 | Rejected-Technical PLOT NO 17 GF PRATAP NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | - | Rejected-Technical being not enlisted in appropriate category |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
28 Jan 2021, 6:00 pmClosed
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
PROVN OF TILING FALSE CEILING AND ROOF TREATMENT AT KANDHAR LINE PROVN OFTOILET BLOCK AT OTM ACCN (RECT ACCN) TO CATER FOR ENHANCE STR OF RECTS OF RRRC AND PROVN OF ADDN POWER POINT GEYSERS FOR JCOs/OR GOVT MD ACCN AT MYNA
2021_MES_408986_1
GE/C-71/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt
₹86,000
Yes
6 Mar 2021
2 Jan 2021
30 Jan 2021
2 Jan 2021
28 Jan 2021
13 Jan 2021
2 Jan 2021 - 13 Jan 2021
Amount
M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors including hacking out existing floor and applying cement slarry @3Kg/Sqm set and jointed in neat cement slurry and pointed in white or oloured cement to match laid over and incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) complete all as specified and as directed.
M&L for glazed ceremic colour tiles (600x300x7mm) thick, in vertical surface includign taking down old tile/ plaster/dado set and jointed in neat slurry and pointed in white or coloured cement to match with tiles laid over and including 10mm thick rendering in cement mortar (1:4) complete all as specified and as directed.
M&L for Non - skid Ceramiccolour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors including hacking out existing floor and applying cement slarry @3Kg/Sqm set and jointed in neat cement slurry and pointed in white or oloured cement to match laid and over incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) complete all as specified and as directed.
S&F Non - skid Ceramic colour tiles 600 x600 x 7 to 8 mm thick in floors including hacking out existing floor and applying cement slarry @3Kg/Sqm and laid ovoer and including and 15mm thick screed bed 1:6 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified.
M&L for roof treatment as per the description below :- a) preparation of roof surfaces by removing all loose material /dust extra for carrying out water proofing treatment. b) Apply bituminous primer @ 0.3 ltr/Sqm (conforming to IS-3384) on prepared surfaces. After drying of primer apply a coat of hot blown 85/25 grade bitumen conforming to (IS-702 @ 1.20 kg/Sqm of prepared surfaces. c) Laying APP (Atatic Polypropylene) modified five layered membrane 3 mm thick and weighing not less than 4 Kg/Sqm with centre core 160 GSM/ Sqm ; core reinforced and laid with 75 mm side overlap and 150 mm end lap. The membrane shall be laid with LPG torch application and overlaps sealed and finished neatly as per the manufacturer specification apply a coat of hot blown 85/25 grade bitumen conforming to (IS-702 @ 1.20 kg/Sqm and apply two coat of silver shield bitumestic aluminum paint all as specified
M & L for PCC 40 mm average thickness type B-1, 1:2:4 (using 20mm graded stone aggregate) as in roof complete all as specified and directed.
M&L for rendering 15mm thick cement plaster in CM 1:4 on fair faces or other than fair faces of brick work or concrete surfaces of wall/roof finished even and smooth without using extra cement incl taking down old plaster complete all as specifed as direted.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specifed as direted by Engr-in-charge.
complete removal exising teratment from old surface of wall by scrubbing with hard brushing, brooming down or steel wire brushing scraping down smook soot mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water & applying two coat cement base paint over one coat of alkali priming on old plastered surfaces of walls complete all as specified and directed.
M & L for snap grid false ceiling with E - board ceiling tiles of size 600x600mm 4mm thick incl aluminium alloy anodised at edges angle 25x25x1.5mm and tee section 38x38x1.5 mm at other than edges both ways fixed with 4mm dia gi wire complete all as specifed as direted by Engr-in-charge. .
S&F for 19/20mm thick Block board grade 2 quality interrior grade commercial type fixed with screws to timber frame work including teak wood leaping and necessary rebating for double shutter where required (Note : teak wood leaping shall be measured and paid separatly) complete all as specifed as direted by Engr-in-charge.
M&L second class hard wood timber scantling plain fillets, square, rectangular or triangular in section clear swan, sectional area exc 13 sqcm & not exc 25 sqcm, secured with nails or brads complete all as specifed as direted by Engr-in-charge..
S&F continuous (Piano) hinges, mild steel bright finish or electro glavanised (width of flap when open 30mm) complete all as specifed as direted by Engr-in-charge.
S&F 40mm dia cupboard knobs fixed with nut screw and washer of mild steel, bright finished complete all as specifed as direted by Engr-in-charge.
S&F Cequered cement concrete tiles with grey cement and pigment 30cm X 30cm X22mm thick set jointed and pointed in neat cement slurry in floors laid over and including 100mm thick cement concrete type D-2 1:4:8 and15mm thick screed bed in CM 1:6 with required surface drassing complete all as specifed as direted by Engr-in-charge.
M&L for machine pressed precast concrete interlocking paver block 60mm thick M-35 grade any shape and size with grey cement and pigment laid over and incl 75 mm thick pcc 1:4:8 type D-2 with required surface drassing complete all as specified and as directed.
M&L for sand filling under floor or in foundations including watering and consolidation complete all as specifed as direted by Engr-in-charge.
M&L hardcore in sub base of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15 cm thick watered and rammed to a true surface complete all as specifed as direted by Engr-in-charge.
M&L for cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) as in side of chequer tiles filling and paver block complete all as specifed as direted by Engr-in-charge..
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loose soil complete all as specifed as direted by Engr-in-charge..
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specifed as direted by Engr-in-charge.
Removal of surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point complete all as specifed as direted by Engr-in-charge..
M&L for cement Concrete 1:4:8, type D2, using 40mm graded stone aggregate incl packing under and haunching against the side for 300mm internal dia of DWCPE pipe after they are laid and tested complete all as specified (thickness of concrete bed 150mm) complete all as specifed as direted by Engr-in-charge..
Supply and laying, DWCPE(SN8) 300 mm dia pipes and snap fit coupler incl testing and laid properly, jointed laid in teenches to a level on concrete bed complete all as specifed as direted by Engr-in-charge.
M&L PCC 1 : 4 : 8, type D2, using 40mm graded stone aggregates, as in foundation of manholes etc complete all as specifed as direted by Engr-in-charge.
M&L Rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfacesfinsihed even and smoth without using extra cement complete all as specifed as direted by Engr-in-charge.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section) in cement concrete 1 : 2 : 4 type B1 using 20mm graded stone aggregate finished smooth and reforming benching as required for 150mm dia pipes complete all as specifed as direted by Engr-in-charge.
M&L for precast fiber reinforced cement concrete manhole cover incl grove and hook arrangement for lifting and placing in position and side covered by MS sheet medium duty of overall size 100x500x75mm complete all as specifed as direted by Engr-in-charge.
M&L for precast fiber reinforced cement concrete manhole cover incl grove and hook arrangement for lifting and placing in position and side covered by MS sheet medium duty of overall size 450x450x50mm complete all as specifed as direted by Engr-in-charge.
M&L for brick work with sub class 'B' bricks old size bricks strainght or curved on plan exc 6m mean radius built in CM 1 : 6 . complete all as specifed as direted by Engr-in-charge.
M&L for RCC Design mix M-25 (using 20mm graded stone aggregate) as in foundation including rafts, footing, foundation beams, plinth beams, lintel band, bases for columns, etc and mass concrete complete all as specifed as direted by Engr-in-charge.
M&L for RCC Design mix M-25 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specifed as direted by Engr-in-charge.
M&L for RCC Design mix M-25 (using 20mm graded stone aggregate) as in roof beams, cantilevers, bressumers, lintels etc complete all as specifed as direted by Engr-in-charge..
M&L for RCC Design mix M-25 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies,desk slaby and in shelves and the like.
Material and labour for brick work with sub class B bricks of old size, straight or curved on plan exc 6m mean radius in half brick walls, in CM 1:4 complete all as specifed as direted by Engr-in-charge.
M & L for mild steel bar 10mm dia and over cut to length,bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specifed as direted by Engr-in-charge..
Ditto as per item descriped in above but 6mm to 8mm dia as in stirrups and binders complete all as specifed as direted by Engr-in-charge..
M&L formwork to sides of concrete foundation, footing, bases of columns, rafts and raft beams, sides and plinth beams; and similar work; vertical or to batter, rough finised surface of concrete complete all as specifed as direted by Engr-in-charge..
M&L for formwork to side and soffits of roof beam, lintel, fair finished flat surface of concrete complete all as specifed as direted by Engr-in-charge..
M&L for formwork to sides of pillars, posts, columns, fair finished, rectangular, square or polygonal surface of concrete complete all as specifed as direted by Engr-in-charge..
M&L for formwork to soffits of suspended slabs such as roof slabs,floor slabs, landings and similar work; n.exc 200mm thick fair finished concrete surface.
M&L PCC 1:4:8, type D2, 100 mm thick, finished even and rough to receive top surfaces in sub base all as specified and directed.
M & L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling, chajja and like surface finished even and smooth without using extra cement incl scafolding etc, complete all as specifed as direted by Engr-in-charge.
M&L for cement concrete 75mm thicktype C-2 1:3:6 (40mm graded aggregate)as in plinth protection and paths laid in alternative panel complete all as specifed as direted by Engr-in-charge..
Supply only integral water proofing compound complete all as specified and as directed.
S&F Cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access doors for 100mm bore pipe complete all as specifed as direted by Engr-in-charge..
S&F Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame and fixing with ancher bolts complete all as specifed as direted by Engr-in-charge.
S&F 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
S&F MS butt hinges medium weight 100 mm size fixed with screws complete all as specifed as direted by Engr-in-charge..
S&F aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws complete all as specifed as direted by Engr-in-charge..
S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with MS screws complete all as specifed as direted by Engr-in-charge..
Supply and fix steel ventilator with top hung shutter including hinges, steel peg stay, complete half fixed glazed and half openable glazed complete all as specified and directed (Glass shall be measured and paid separately) complete all as specifed as direted by Engr-in-charge..
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specifed as direted by Engr-in-charge.
S&F Sheet glass pin head type, 4.0mm thick, ordinary quality glazing with glazing clips, rubber and necessary joining cleats in square n exc 0.5 sq. m in each pane complete all as specifed as direted by Engr-in-charge..
S&F in vitreous China squatting pan, 'orissa' pattern size 580 x 440 mm white with integral foot rest water closet complete all as specifed as direted by Engr-in-charge..
S&F in 100 mm dia CI 'P' or 'S' trap complete all as specifed as direted by Engr-in-charge..
S&F in 10 Ltr PVC valveless, syphonic action type flushing cistern low level with inlet, ball valve, float and handle including brackets and PVC out let sutaible for IWC complete all as specifed as direted by Engr-in-charge..
Supply and fix galvanized steel tubing, 15 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed
Supply and fix galvanized steel tubing, 20 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed
Cutting chases, pinning in, for brick walls built in cement mortar, making good to facings where required and pointing in cement mortar 1:3 or PCC 1:2:4 type B-O(using 12.5 mm graded aggregate) as required for conceled water tubing etc cutting exceeding 10cm girth but not exc. 20 cm complete all as specifed as direted by Engr-in-charge.
S & F in 15mm angle valve cast copper alloy screwed down high pressure with fancy type chromium plated handle screwed both ends or for unions etc complete all as specifed as direted by Engr-in-charge..
M&L preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
S & F 15mm bore CP bib tap fancy type long body cast copper alloy with capstan head handle screwed for iron pipe or for brass ferrule in repairs complete all as specifed as direted by Engr-in-charge.
Material and labour for rotational moulded polyethylene water storage tanks 1000 lts capacity, double layered (cylindrical vertical with closed top) hoisted and fixed in position including 25 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description complete all as specifed as direted by Engr-in-charge.
Supply and fixed Ball valves, high pressure of brass with epoxy coated aluminium rod and high density plastic ball screwed for 20mm bore GI pipe of having minimum weight 210gms complete all as specifed as direted by Engr-in-charge.
M & L for in PVC connection 600mm long with 2 nos brass check CP nuts as suitable complete all as specified
S & F in vitreous china wash hand basin (flat back) white of size 550x400mm long incl waist pipe and CP waste coupling and a pair of mild steel angle iron brackets of suitable size complete all as specifed as direted by Engr-in-charge.
S&F 15 mm dia pillar taps, fancy type brass with capstan head chromium plated screwed down high pressure with or without lettered “hot/cold” with long screwed shank and flynut screwed ,complete all as specifed as direted by Engr-in-charge.
M&L for rendering 15mm thick cement plaster in CM 1:4 on fair faces or other than fair faces of brick work or concrete surfaces of wall/roof finished even and smooth without using extra cement complete all as specifed as diret
M&L surface excavation n exc 30 cm deep and averaging 15cm deep and getting out soft/loose soil all as specified and directed.
M&L ceiling rose, surface polycarbonate isolated body three terminals complete all as specifed as direted by Engr-in-charge.
Supply and fixing fresh Air fan 250 sweep singe phase 230 Volts 50 Hz complete with accessories etc.complete all as specifed as direted by Engr-in-charge.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Make:- Legrand / L&T/ABB.
Supply and fix MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. strip from earth electrode to the earth test point of galvanized Iron/steel of size 75 x 75 x 25 mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe Med grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed.
Supply and fix 45W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed. Make: Havells/Bajaj/Crompton
Supplying, laying sub class 'B' bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
Material, labour jointing & testing XLPE insulated armoured heavy duty electric cable with standard aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core including making connection with suitable size of cable gland, aluminium lugs etc complete including taking down old U/S cable all as specified and directed.
Supply & Fixing GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia complete all as specified and directed
M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall & including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly for
one light /fan point controlled by one way switch.
One 5 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately.
All as above item No 83.02 but Same board.
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 4 sqmm FRLS 1100 Volts in New PVC concealed conduit in new M S steel terminal boxes modular including one run of using 2.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one power point, all as specified and directed by Engr-in-Charge.
M & L Submain wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 volts grade in and including PVC conduit ISI marked alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. Note: Three runs of 6 sqmm cable and one run of PVC conduit shall be measured as one RM.
M & L Submain wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 volts grade in and including PVC conduit ISI marked alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. Note: Three runs of 4 sqmm cable and one run of PVC conduit shall be measured as one RM.
M&L switch Piano flush type 5 Amp SP one wayall as specified and directed by Engr in Charge.
M&L switch piano flush type 15 Amp SP one way all as specified and directed by Engr in Charge.
M&L socket outlet 5 pin 5 Amp flush type all as specified and directed by Engr in Charge.
M&L socket outlet 2 in 1,3 pin 5/15 Amps all as specified and directed by Engr in Charge. Make:-
S & F water heater storage type Geyser vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection having adjustable knob for temperature control and inner tank should be glass line coated tank and outer body material of ABS with high pressure with standing enabling (up to 8 bar pressure) capacity , should be glass line coated capacity 25 ltrs having heating element 1.5 KW and not less than 3 star ratingh suitable for 230 Volt , 50 Hz electric supply complete all as specified and directed.
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed.
M&L MCB SPN 32 Amp "C " curve complete all as specifed as direted by Engr-in-charge. .
M & L for cutting the existing GI tube pipe for insertation of new Tee branches, reducers in any position of 15 mm dia pipe line complete all as specified and directed.
S&F of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of cap 15mm dia complete all as directed
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix 10/12 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
GIAN ENGINEERS
S D Constructions
imran construction company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .