| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹11.3 LAdmitted-Finance | -24.48% | ₹11.3 L | L1 | Admitted-Finance |
| 2 | L2₹13.2 LAdmitted-Finance | -11.91% | ₹13.2 L | L2 | Admitted-Finance |
| 3 | L3₹13.8 LAdmitted-Finance | -8.01% | ₹13.8 L | L3 | Admitted-Finance |
| 4 | L4₹14.1 LAdmitted-Finance | -5.40% | ₹14.1 L | L4 | Admitted-Finance |
| 5 | L5₹14.5 LAdmitted-Finance | -2.95% | ₹14.5 L | L5 | Admitted-Finance |
Tender Value
₹14.9 L
EMD Value
₹29,900
Closing Date
10 Feb 2026, 6:00 pmClosed
EE PHED Div Bhadra
EE PHED Div Bhadra
Replacement of Pump Sets against summer contigency 2026 at UWSS Bhadra under Subdn Bhadra
2026_PHCJA_531744_1
EE/PHED/BDR/2025-26/122
Open Tender
Civil Works - Water Works
60 days
EE PHED Div Bhadra
As per Bid Documnts
2 documents required · 2 mandatory
₹1,000
EE PHED Div Bhadra
₹29,900
Yes
13 Feb 2026
24 Jan 2026
11 Feb 2026
24 Jan 2026
10 Feb 2026
24 Jan 2026
Replacement of Pump Sets
Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ. Discharge 31 to 40 LPS and head 31 to 40 M
--do----Discharge 51 to 60 LPS and head 20 to 30 M
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)
Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 7.5 KW (10 HP) & head up to 120 mtr.
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:-(a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testingprocedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testingfacilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. 70.0 Sq. mm 3.5 CORE
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured copper cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:-(a) Copper conductor of electrlytic grade copper, purity>99.97 % ISI marked as per IS:1554 P-I / IS :7098 P - I(b) conductor shall made of copper rods confirming toIs613-1964,IS 3975-1999 for armouring of cables inarmoured cable items , IS5831 for sheath, IS 10810 (Part0 to 64 ) for testing procedures(c) OEM Must have ISO 9001 & 14001 certifications & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted. All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 3 core 35 sqmm
3 core 16 sqm
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf