Capital (Works)
WORKS
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of IRSGCC, April 2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Non-Compliance to the above will lead to summary rejection of your offer
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one inwhich tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender,orTwo similar works each costing not less than the amount equal to 40% of advertised value of thetender,or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. For details regarding submission of self attested documents/certificates, please refer 'Important instructions to tenderers for open tenders costing more than Rs.50 lakhs available at documents section. Similar nature of work is defined as following, "Works involving wiring/lighting with 240V,1 phase or 415V, 3 phase system with control gear and protection arrangements in residential buildings or service buildings or railway stations /yards or colony/highway lightings " (CEE/MAS Letter No. E.252/1/8/G dated 02.08.2013)" .Tenderers should mandatorily submit Work completion certificate issued by Competent Authority. In case of experience certificate submitted by tenderer for composite works, experience certificate shall clearly specify the executed cost of Electrical work duly certified by Experience Certificate issuing authority Non compliance to above will lead to summary rejection of your offer.
10 conditions · 8 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1) Tenderer should attach self attested copy of PAN CARD and photo identification in support of their Identity. 2) The documents attached to the tender document should be clear and legible for evaluation of tenders. Proper care to be taken in this regard
A copy of document to be uploaded containing the following details: Name of the tenderer/ contractor, Validity of DSC, Complete address with pincode, Contact No.
Scanned copy of PAN card has to be enclosed
Scanned copy of TIN card has to be enclosed
A copy of NEFT form duly filled in the details as necessary along with a cancelled Cheque to be uploaded. (The tenderer/ contractor not having NEFT form may down load the empty NEFT form available in documents site)
Information/ certificates required as per Tender document for partnership deed, Article of association, MOU, JV AGREEMENT, Proprietary firm etc.
Self Attested copy of Experience Certificate of Previous Work Done -The bidder should submit documents related to completed/on-going similar service contracts during the last three previous financial years and the current financial year along with the details of payments received and percentage penalties imposed therein, to classify the completed/ on-going similar service contracts.
For materials of purchase value Rs.5 lakhs and above, inspection shall be done by third party i.e. M/s. RITES and all expenditure in connection with the inspection shall be borne by thetenderer/Contractor . For ISI marked products, if the order is placed on ISI certified manufacturers, the materials can be accepted on firm's WTC
Electrical arrangements for: Redevelopment of Jolarpettai Railway Station under ABSS Phase-I (Additional Items)
ME-29-II-1087-2026
ME-29-II-1087-2026
Open
Works - General
90 Days
Chennai, Tamil Nadu
₹0
₹2.0 L
14 Apr 2026
24 Mar 2026
31 Mar 2026
61 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,03,75,087 | ||
| — | — | — | Above/ 116550.00 Below/P | ||
| Supply ,Installation, Testing and commissioning of loop in loop out box of size 170x170x105 mm and made up of SMC ( similar to Sintex catalogue reference No.GSJB- 1414) and comprising of 1 No. of 6 way 15 amps connector block, 1 No. of 3 plate ceiling rose,1 No of 6A,MCB 'C' curve duly pre wired up to ceiling rose and provision of the same close to light fitting on platform shelter including wiring from junction box to light fitting by using 3 core 1.5 sq.mm multi stranded flexible copper cable complete including all fixing arrangements and other accessories required complete as per site conditions in a manner as directed by the section engineer in charge at site. | — | 150.00 | — | — | |
| — | — | — | Above/ 2619360.00 Below/P | ||
| Supply, Erection, Installation and testing of Single Sided Wall/Double Sided wall / hanging / floor / pole mounting type LED illuminated, Modular, Changeable Aluminium extruded profile signage / direction board in Full/Half/Semi Parabolic and Elliptical square and multi angle shape, with die molded internal structural brackets (Nylon/SS) and aluminium extruded heat sink. Suitable size end cap PC/SS304 should be provided with provision of illuminated Logo. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter vision angle shall not be less than 160 degree and visibility not be less than 75%. The approved color text and graphics shall be printed router cut on monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. A pole with grooves for tricolour LED/Neon light installation. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4- 8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. The work should be executed as per the approved Detailed specifications (STANDARD SIGNAGES AT STATIONS ON INDIAN RAILWAYS -APRIL 2023) | — | 1530.00 | — | — | |
| — | — | — | Above/ 45000.00 Below/P | ||
| Fabrication, Supply, Fixing of clamp for 30W LED 4 feet fitting , of suitable size GI Flat including all accessories required complete as per site conditions complete in a manner as directed by Section Engineer in charge at site. | — | 500.00 | — | — | |
| — | — | — | Above/ 1032500.00 Below/P | ||
| Providing of saw cutting in concrete pavement 200mm to 250mm depth including all men and materials under contractor's scope of work | — | 2500.00 | — | — | |
| — | — | — | Above/ 114000.00 Below/P | ||
| Supply and Drawing of Copper(Cu) wire using 1.5 sq.mm fire retardant Low smoke PVC insulated unsheathed single copper conductor cables conforming to IS:694/1990 or latest duly along wires vide and from MCB DB to switch boards and switch boards to light and fan points or elsewhere in a manner as directed by Senior Section Engineer in charge at site. The colour of cable shall be as per instructions of the SSE incharge at site. | — | 6000.00 | — | — | |
| — | — | — | Above/ 276552.00 Below/P | ||
| Supply, Installation, Testing and commissioning of 200W LED High Bay light fittings as per specification enclosed using suitable mounting and fixing arrangements as per industrial standards including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper conductor flexible chord complete in a manner as directed by Section Engineer in charge at site. | — | 36.00 | — | — | |
| — | — | — | Above/ 886546.00 Below/P | ||
| Design, Supply, Erection, Testing and commissioning of Facade Lighting as per Annexure enclosed in Documents section | Lumpsum | 1.00 | 8,86,546 | — | |
| — | — | — | Above/ 514088.00 Below/P | ||
| Design, manufacture, supply (at site) of 20 metre high mast system of hot tip galvanized complete with head frame assembly, lantern carriage, double drum winch, stainless steel wire rope, suitable control panel, timer switch, twin dome aviation obstructing fittings suitable for high mast including lamps, electrical cable, 9 Nos of 200w high efficient LED flood light fittings with 9 Numbers of Arms and (as per specification enclosed) etc., and other standard accessories as per specification enclosed including integrated power tool with reversible electric motor and foundation bolts manufactures from special steel along with nuts, washers of suitable size of anchor plate and template and erection, testing and commissioning of the above high mast as per specification enclosed on the RCC foundation by using modern engineering practice by crane / derrick system complete as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 1)200w flood light fittings and accessories shall be as per specification enclosed.2)High Mast Foundation Drawing is enclosed for reference purpose only .Original High Mast Drawing should be submitted by Contractor along with Soil test Report 3)Ten percentage of overall quoted Bid Rate for each High Mast is considered as cost of LED fixtures. Warranty/Guarantee/Deferred Payment clause for LED fixtures will be dealt accordingly as mentioned in Tender Document 4)Remaining Ninety percentage of overall quoted Bid Rate for each High Mast is considered as High Mast cost .Warranty/Guarantee clause for High Mast will be dealt accordingly as mentioned in Tender Document | — | 1.00 | — | — | |
| — | — | — | Above/ 595800.00 Below/P | ||
| Supply of 4 core 120 sq. mm ISI Marked cross linked polyethylene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (i) Batch No/Drum No/Lot No/Serial No of the tested cable (ii) LOA/Agreement No as reference with railway mentioned as the consignee/customer. (iii) The WTC should be issued on the official letter head of the manufacturer (OEM). Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. Ref: PCEE/MAS Ltr no:E.252/1/8/Circular dtd 25-03-2025 | — | 900.00 | — | — | |
| — | — | — | Above/ 250000.00 Below/P | ||
| Supply of 4 core 95 sq. mm ISI Marked cross linked polyethylene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (iv) Batch No/Drum No/Lot No/Serial No of the tested cable (v) LOA/Agreement No as reference with railway mentioned as the consignee/customer. (vi) The WTC should be issued on the official letter head of the manufacturer (OEM). Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. Ref: PCEE/MAS Ltr no:E.252/1/8/Circular dtd 25-03-2025 | — | 500.00 | — | — | |
| — | — | — | Above/ 202000.00 Below/P | ||
| Supply of 4 core 70 sq. mm ISI Marked cross linked polyethylene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (vii) Batch No/Drum No/Lot No/Serial No of the tested cable (viii) LOA/Agreement No as reference with railway mentioned as the consignee/customer. (ix) The WTC should be issued on the official letter head of the manufacturer (OEM). Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. Ref: PCEE/MAS Ltr no:E.252/1/8/Circular dtd 25-03-2025 | — | 500.00 | — | — | |
| — | — | — | Above/ 531000.00 Below/P | ||
| Supply of 4 core 35 sq. mm ISI Marked cross linked polyethylene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (x) Batch No/Drum No/Lot No/Serial No of the tested cable (xi) LOA/Agreement No as reference with railway mentioned as the consignee/customer. (xii) The WTC should be issued on the official letter head of the manufacturer (OEM). Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. Ref: PCEE/MAS Ltr no:E.252/1/8/Circular dtd 25-03-2025 | — | 3000.00 | — | — | |
| — | — | — | Above/ 171000.00 Below/P | ||
| Supply of 4 core 25 sq. mm ISI Marked cross linked polyethylene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (xiii) Batch No/Drum No/Lot No/Serial No of the tested cable (xiv) LOA/Agreement No as reference with railway mentioned as the consignee/customer. (xv) The WTC should be issued on the official letter head of the manufacturer (OEM). Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. Ref: PCEE/MAS Ltr no:E.252/1/8/Circular dtd 25-03-2025 | — | 1000.00 | — | — | |
| — | — | — | Above/ 100080.00 Below/P | ||
| Demolishing plain cement concrete in platform or elsewhere, disposal of material at least 6m away from track centre within railway land by saw cutting/breaker as per site conditions to avoid any damage to nearby site complete in a manner as directed by the Section Engineer in charge at site. | — | 180.00 | — | — | |
| — | — | — | Above/ 919836.00 Below/P | ||
| Supply and provision of mass concrete for platforms or elsewhere with 1:2:4 ratio using 20mm graded blue metal complete in a manner as directed by the Section Engineer in charge at site. NOTE: i) Cement shall be Ordinary Portland Cement, 43 grade, conforming to IS: 456 or latest. ii)Proper compaction of cement concrete shall be ensured as per standard industrial practices. iii)The finished level should match with surface level properly | — | 162.00 | — | — | |
| — | — | — | Above/ 74250.00 Below/P | ||
| Excavation of Cable trench in all kinds of soils duly removing all obstructions in the way of cable trench, dumping at embankment site within railway land complete as per specification enclosed and in a manner as directed by the Section Engineer in charge at site. NOTE: The Section Engineer, in charge at site, will indicate the route of cable trench. | — | 450.00 | — | — | |
| — | — | — | Above/ 21150.00 Below/P | ||
| Re-filling of trench with excavated earth, ramming, consolidation and bringing back the surface to original condition complete in a manner as directed by the Section Engineer in charge at site. | — | 450.00 | — | — | |
| — | — | — | Above/ 921000.00 Below/P | ||
| Supply of perforated cable trays of 300mm width X 50mm height made of 2.00mm thick hot dip galvanized Sheet steel complete with all accessories including coupler plate, supports fabricated using 40x40x6 mm MS angles for the longitudinal members and 40 x 6mm MS flats for the cross members and erection, testing and commissioning of the same duly supported from walls/ ceiling/roof purloins/structural steel works or elsewhere using intermediate supports by 40x6 mm MS flats complete in a manner as directed by Section Engineer-in-charge at site. Note:-The cable tray supports shall be applied with two coats of red oxide primer and painted with two coats of bright aluminium paint. | — | 1000.00 | — | — | |
| — | — | — | Above/ 180600.00 Below/P | ||
| Supply and Laying of 110 mm dia ISI Marked High Density Polyethylene pipes of material grade PE-100 and with Pressure rating of 6.0 P.N conforming to IS: 4984 / 1995 or latest in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. | — | 600.00 | — | — | |
| — | — | — | Above/ 270000.00 Below/P | ||
| Supply and Laying of 63 mm dia ISI Marked High Density Polyethylene pipes of material grade PE-100 and with Pressure rating of 6.0 P.N conforming to IS: 4984 / 1995 or latest in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site. | — | 3000.00 | — | — | |
| — | — | — | Above/ 67500.00 Below/P | ||
| Supply of 4 feet 30W LED Batten light fitting suitable to work on 240V single phase 50 Hz AC supply with lamp and all standard accessories suitable and similar to the specification enclosed and provision of the same using suitable mounting arrangements including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper conductor flexible pendant chord in a manner as directed by Section Engineer in charge at site. | — | 125.00 | — | — | |
| — | — | — | Above/ 42000.00 Below/P | ||
| Supply and provision of 5 feet long 2" dia "B" class GI pipe confirming to IS: 1239 P1/2004, P2/1992 or latest for protecting the vertical raise of cable at walls / stanchions / FOB /lamp post duly burying the pipe to a depth of 0.3 m in ground/floor and clamping the pipe at regular intervals complete including coping arrangement and for concealing in the floor area near MDB in a manner as directed by Section Engineer in charge at site. Note: i) The open end of GI pipes shall be filled with "M seal" sealing compound to prevent ingress of water. ii) 5 feet length of G.I pipe is taken as 1 No for unit purpose. Damage to floors, if any, made for burying the pipe shall also be re-done to bring back the surface to original condition. | — | 50.00 | — | — | |
| — | — | — | Above/ 48650.00 Below/P | ||
| Supply of material & providing light/fan point wiring concealed with 2 runs of single core multi- strand copper wire, PVC insulated unsheathed, LSHF / ZHFR, of size 1.5 sq.mm., along- with earth wire and modular switches, complete with all accessories, junction box, ceiling rose etc., as per specifications enclosed | — | 175.00 | — | — | |
| — | — | — | Above/ 111840.00 Below/P | ||
| Supply and stringing of over head mains beneath platform shelters using 5 runs of 16 sq. mm PVC insulated and PVC sheathed multi stranded aluminium conductor cable duly by binding onto insulators of brackets (Drawing enclosed) to be provided at appropriate locations as per site conditions complete in a manner as directed by Section Engineer in charge at Site. Note: 5 runs of 16 sq.mm cable are taken as 1m for unit purpose. | — | 480.00 | — | — | |
| — | — | — | Above/ 35400.00 Below/P | ||
| Supply of 4 core 35 sq. mm ISI Marked cross linked polyethylene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (i) Batch No/Drum No/Lot No/Serial No of the tested cable (ii) LOA/Agreement No as reference with railway mentioned as the consignee/customer. (iii) The WTC should be issued on the official letter head of the manufacturer (OEM).Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. Ref: PCEE/MAS Ltr no:E.252/1/8/Circular dtd 25-03-2025 | — | 200.00 | — | — | |
| — | — | — | Above/ 25875.00 Below/P | ||
| Supply and Concealing of 25mm dia rigid PVC conduits [IVORY colour] confirming to IS: 9537/P3/1983 or latest [ISI Marked] with wall thickness not less than 2.0 mm along with all accessories like Bends,Junction Boxes and other items required as per site conditions and including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting walls to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site and as per specification for wiring/ rewiring enclosed. | — | 575.00 | — | — | |
| — | — | — | Above/ 23780.00 Below/P | ||
| Supply and drawing of inside mains using 2 runs of 6 sq. mm [from MCB DB to switch boards and from switch boards to switch boards or elsewhere] Fire Retardant Low Smoke PVC insulated unsheathed multistranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly inside the PVC conduit concealed/laid complete as per the specification enclosed and in a manner as directed by Section Engineer in charge at site. Note: - 2 runs of 6 sq. mm copper conductor are taken as 1m for quantity purpose. | — | 205.00 | — | — | |
| — | — | — | Above/ 14560.00 Below/P | ||
| Supply and drawing of inside mains using 2 runs of 4 sq. mm [from MCB DB to switch boards and from switch boards to switch boards or elsewhere] Fire Retardant Low Smoke PVC insulated unsheathed multistranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly inside the PVC conduit concealed/laid complete as per the specification enclosed and in a manner as directed by Section Engineer in charge at site. Note: - 2 runs of 4 sq. mm copper conductor are taken as 1m for quantity purpose. | — | 160.00 | — | — | |
| — | — | — | Above/ 7015.00 Below/P | ||
| Supply and drawing of inside mains using 2 runs of 2.5 sq. mm [from MCB DB to switch boards and from switch boards to switch boards or elsewhere] Fire Retardant Low Smoke PVC insulated unsheathed multistranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly inside the PVC conduit concealed/laid complete as per the specification enclosed and in a manner as directed by Section Engineer in charge at site. Note: - 2 runs of 2.5 sq. mm copper conductor are taken as 1m for quantity purpose. | — | 115.00 | — | — | |
| — | — | — | Above/ 157155.00 Below/P | ||
| Supply, Installation, Testing and commissioning of 5 kVA ,120 minutes' backup time Online UPS similar to GEM Contract No: GEMC-511687725739407 attached along with this Tender. Warranty certificate and Authorized dealership certificates should be submitted along with the supply of the material. | — | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Checklist.pdf
ATTACHMENT
FacadeAnnexure.pdf
ATTACHMENT
FacadeImages.pdf
ATTACHMENT
FacadeSpecialNotes.pdf
ATTACHMENT
GCC2022.pdf
ATTACHMENT
GCCACS1.pdf
ATTACHMENT
GCCACS2.pdf
ATTACHMENT
GCCACS3.pdf
ATTACHMENT
IRSGCCACS4.pdf
ATTACHMENT
IRSGCCACS5.pdf
ATTACHMENT
IRSGCCACS6.pdf
ATTACHMENT
IRSGCCACS7.pdf
ATTACHMENT
IRSGCCACS8.pdf
ATTACHMENT
IRSGCCACS9.pdf
ATTACHMENT
IRSGCCACS10.pdf
ATTACHMENT
GeneralinstructionstoTenderers.pdf
ATTACHMENT
ImportantinstructionstoTenderers.pdf
ATTACHMENT
SpecialconditionsofContract.pdf
ATTACHMENT
HighMastSpecification.pdf
ATTACHMENT
HighMastDrawing.pdf
ATTACHMENT
LEDTubeLightSpecification.pdf
ATTACHMENT
LEDspecification-SELSpecPower2-2015.pdf
ATTACHMENT
MCBDrawing.pdf
ATTACHMENT
MSBracketsDiagram.pdf
ATTACHMENT
NEFTFORM.pdf
ATTACHMENT
PaymentClause.pdf
ATTACHMENT
PointWiringSpecificationDetailed.pdf
ATTACHMENT
SpecificationforlayingUndergroundcable.pdf
ATTACHMENT
specificationforwiringandrewiring.pdf
ATTACHMENT
Undertaking.pdf
ATTACHMENT
UPSGEMDocument.pdf
ATTACHMENT
Part1_compressed.pdf
ATTACHMENT
Part2_compressed.pdf
ATTACHMENT
Part3.pdf
ATTACHMENT
Part4.pdf
ATTACHMENT
IRSGCCACS11.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .