Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.1 LAccepted-AOC AWANTA BHAWAN SOURA SRINAGAR 190011 J K | SRINAGAR | JAMMU AND KASHMIR | 190011 | L1 | Accepted-AOC AOC | |
| 2 | L2₹52.2 L+₹7.1 L (15.8%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | Rejected-Technical 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | - | Rejected-Technical Due to adequate work load i.e beyond 5 times upper tender limit | |
| 4 | Rejected-Technical | - | Rejected-Technical No due to declared as No in WLR | |
| 5 | Rejected-Technical HOUSE NO 49 SECTOR 28 FARIDABAD 121008 HR | FARIDABAD | FARIDABAD | HARYANA | 121008 | - | Rejected-Technical Due to not enlisted with requisite category i.e (i) |
Tender Value
₹25.6 L
EMD Value
₹51,200
Closing Date
20 Nov 2021, 6:00 pmClosed
GE
GE 860 EWS
REPAIR /MAINT OF DI/GI/PPR/HDPE PIPE LINES INCLUDING VALVES, FLUSHING OF BORE WELLS, REPAIR TO PUMP MOTORS AND STARTERS, SUBMERSIBLE CABLES, COLUMNS PIPE, CONNECTED ITEMS AT KARU AND SHESHARTHANG AND MAINT AND REPAIR OF DG SET AND ALLIED WORKS AT TAN
2021_MES_482978_1
8163/2021-22/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Karu
Class D
Category c i
9 documents required · 9 mandatory
₹500
Yes
GE 860 EWS
₹51,200
Yes
24 Feb 2022
21 Oct 2021
3 Dec 2021
21 Oct 2021
20 Nov 2021
12 Nov 2021
Amount
Dismantling disconnecting and taking out the unservicable Burner Assy 50000 KL from the oil fired boiler installed at CHS installation & Supply and fixing the same as specified and as directed by Engr-in-charge
Dismantling disconnecting and taking out the unservicable Burner Assy 100000 KL from the oil fired boiler installed at CHS installation & Supply and fixing the same as specified and as directed by Engr-in-charge
Dismantling disconnecting and taking out the unservicable Burner Assy 200000 KL from the oil fired boiler installed at CHS installation & Supply and fixing the same as specified and as directed by Engr-in-charge
Taking up or down old unserviceable DI/GI tubing connection including disconnection of fittings from tubing where required and cleaning for refixing or removal from site complete as directed by Engr-in-Charge of following sizes :-
PPR/GI pipe 25 mm dia
PPR/GI pipe 32 mm dia
PPR/GI pipe 40 mm dia
GI/PPR pipe 50 mm dia
GI/PPR pipe 80 mm dia
GI/PPR of 100 mm bore
GI/PPR of 75 mm bore
Refixing/Relaying of old DI/GI tubing retrieved from srl item No 4 and connections in new or old position including S & F new tightening rubber complete all as directed by Engr-in-Charge.
PPR/GI pipe 25 mm dia
PPR/GI pipe 32 mm dia
GI/PPR pipe 40 mm dia
PPR pipe 50 mm dia
GI/PPR pipe 75 mm dia
GI/PPR pipe 80 mm dia
GI/PPR pipe of 100 mm bore
Supply & laying of PPR/GI/DI pipe of the following sizes and grade complete with all fittings laid in trenches complete as directed by Engr-in-Charge, of following sizes (Note when pipe laid in straight line then the 3rd length is required to be connected by union
PPR pipe 3 layer SDR 7.4 , 25 mm dia
PPR pipe 3 layer SDR 7.4 , 32 mm dia
PPR pipe 3 layer SDR 7.4 , 40 mm dia
PPR pipe 3 layer SDR 7.4 , 50 mm dia
PPR pipe 3 layer SDR 7.4 , 75 mm dia
M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 80 mm complete all as specified and as directed
M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 100 mm complete all as specified and as directed
M & L for Insulation of MS Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of sizes 100 mm bore complete all as specified and as direcred by Engr-in-charge'
M & L for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of sizes 80 mm bore complete all as specified and as direcred by Engr-in-charge'
M & L for Insulation of MS Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of sizes 25 mm bore complete all as specified and as direcred by Engr-in-charge'
M & L for Insulation of MS Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of sizes 32 mm bore complete all as specified and as direcred by Engr-in-charge'
M & L for Insulation of MS Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of sizes 40 mm bore complete all as specified and as direcred by Engr-in-charge'
M & L for Insulation of MS Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of sizes 50 mm bore complete all as specified and as direcred by Engr-in-charge'
M & L for Insulation of MS Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of sizes 75 mm bore complete all as specified and as direcred by Engr-in-charge'
Dismantling/disconnecting all the connection of of glycol pipes and electrical connection from the U/s boiler of 250 KW Supply and fixing the same complete all as specified and as directed by Engr-in-charge.Make rapid cool.
Dismantling disconnecting the U/s boiler element 25 KW Each from the boiler of 750 KW capacity and supply and fixing the same as specified and as directed by Engr-in-charge.
Supply and fixing of Suction valves for compressors units , with connected chilled/gas piping complete all as specified and directed by Engr-in-charge.
Supply and fixing of discharge valves for compressors units , with connected chilled/gas piping complete all as specified and directed by Engr-in-charge.
Material & Labour for complete leak testing the entire Package AC plant system consisting of 39 TR capacity consisting of variour makes for compressors, condensors, evaprators, with connected chilled/gas piping, expansion valves and all accessories complete with Nitrogen gas, locating leaks positions, rectifing the leaks and flushing out the complete system including pressure testing and holding the pressure for 48 Hrs for observation for any pressure drop in the system and rectifying complete and filling the regrigrent gas to desired pressure and testing complete all as directed by the Engr in charge.
Supply only Refrigerant gas 'R- 134' in manufacturer's sealed cylinder. [Make: Floron/ Mafron/ Retron] [Note:- (i) Empty cylinder will be returned to contractor on completion of work (ii) Net weight of refrigerant gas shall be measured and paid.
M&L for repair to AHU 39 TR including change of air cleaner filter including painting the entire unit complete all as specified and as directed by Engr-in-charge.
Material and labour M&L for duct insulation by pasting the thermocool of 1 inch thickness by adhessive putting PUF of 3 inch thickness, and wire netting of galvanised steel wire of 1.40mm dia fixed with inned tacks or wire staplea, size of mesh 1 mm wraping around the duct and rendering in cement 1:4,15mm thick over the chicken wire mesh, finished even and smooth without using extra cement all as specified and directed by Engineer- in -charge with following:- (i) Cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free from miliscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (ii) Applying rubber based adhesive CPRX compound. (iii) Sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50mm wide to make the insulation leak proof. (iv) Securing the insulation with and including mechanically fastened nylon/ steel straps of size 12mm/ 50mm at maximum intervals of 1.2m
Excavation in trenches in hard / dense soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for laying of cables & foundation of poles, stay assembly, complete all as specified and directed by Engr-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge.
Taking out old unserviceable/serviceable un-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge. Note:- Serviceable un-reinforced concrete PCC cable cover kept in safe custody for reuse at site and unserviceable un-reinforced concrete PCC cable cover through in low lying area.
Laying only old reinforced PCC cable cover of any size as retrieved from serial item No- 04 above, complete all as directed by Engineer-in-Charge.
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge.
Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by Engr-in-Charge.
Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade 10 sq mm 2 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
S&F of galvanized iron pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
Dismantling and taking down unserviceable / defective street light fitting / Flood light fitting of any wattage alongwith mounting bracket, flat iron clamp, nuts bolts etc from overhead LT poles complete all as directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S&F of LED street light luminaire of 120 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge. Make : Crompton Cat part No LSTN-120-CDL-A
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp
Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp
S&F LED bollard light 10 with die cast aluminium housing with warm white COB LED reflector and IP65 protection and incl making all electric connection, complete all as specified and directed by Engineer in charge. Make :Crompton Cat Part No LBLA3-10-CDL Maya III
S&F in replacement of street light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 40 mm dia size light grade complete with and incl 02 nos MS clamp made of MS flate iron of 50 x 6 mm size with nut, bolts, washer etc with and incl two coats of aluminum paint over a coat of red oxide primer, complete all as directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm nominal cross section in service connections complete all as specified and as directed by Engineer-in-Charge.
osho traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .