Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC S NO 41 4K JAIHIND SOCIETY GANESH NAGAR NEAR ANAND PARK VADGAON SHERI PUNE 411 014 | PUNE | PUNE | MAHARASHTRA | 411014 | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.8 L+₹6.1 L (19.7%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹38.9 L+₹8.1 L (26.4%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹41.2 L+₹10.4 L (33.9%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹43.6 L+₹12.8 L (41.6%)Rejected-AOC | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | Srinivasa Consructions L5 | OM INFRA L1 | M. Laxman Rao and sons L2 | Srinivash Engineers L4 | SRI SAI RAM ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00Note : 1. Contractor need to purchase minimum 50% of all items mentioned in this CA within 20 days of getting sample approval and kept in custody so that no delay in work due to non-availability of materials will be faced. Contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of item/date. 2. Contractor should buy the exact items which are given with catalogue reference. Other makes will be approved only by submitting non availability Certificate Company. Contractor need to remove all the dismantled items without delay. 3. Rate quoted for demolition/dismantling /taking down is inclusive of removing the same from site and dumping at given locations anywhere inside station. 4. Contractor will make his own arrangement to store his items. 5. Some places in this contract where the vehicle will not reach the spot directly, the material will be moved manually in these places. The rate quoted will be considered all inclusive on this account. 6. All trade skilled labour required in this contract shall be present daily in working hours, irrespective of complaints received. 7. Complaint for a similar items may be in scattered / different area, quoted rate will be considered all inclusive on this account. | ||||||||
| 1.01 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard/dense soil for laying of cables/ for erection of poles/ for stay assembly etc complete all as specified and directed by Engineer-in-Charge. | 389 | Cum | 320 ₹1,24,480 | 300 ₹1,16,700 | 240 ₹93,360 Lowest | 240 ₹93,360 Lowest | 300 ₹1,16,700 |
| 2.00 | Boaring/ drilling (horizontally ) of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 80 mm dia suitable for 0.4 mpa working pressure. all as specified and directed by Engineer in charge.. | 20 | RM | 3,000 ₹60,000 | 900 ₹18,000 | 1,170 ₹23,400 | 850 ₹17,000 Lowest | 1,100 ₹22,000 |
| 3.00 | Supply and spread clean Ridelled soil in trenches for cushioning of cable complete all as specified and directed by Engineer-in-Charge. (Note: Punned down thickness only shall be measured for the purpose of payment) | 117 | Cum | 100 ₹11,700 Lowest | 700 ₹81,900 | 720 ₹84,240 | 800 ₹93,600 | 950 ₹1,11,150 |
| 4.00 | Supply and lay un-reinforced precast concrete cable cover , class LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables complete all as specified and directed | 9,666 | Each | 17 ₹1,64,322 Lowest | 27 ₹2,60,982 | 18 ₹1,73,988 | 20 ₹1,93,320 | 28 ₹2,70,648 |
| 5.00 | Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engineer-in-Charge. | 232 | Cum | 50 ₹11,600 | 80 ₹18,560 | 72 ₹16,704 | 45 ₹10,440 Lowest | 99 ₹22,968 |
| 6.00 | Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge. | 131 | Cum | 60 ₹7,860 | 80 ₹10,480 | 72 ₹9,432 | 55 ₹7,205 Lowest | 99 ₹12,969 |
| 7.00 | Material and labour for 80mm dia bore tubes, 'light grade' galvanised, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed by Engineer-in-Charge. | 24 | RM | 500 ₹12,000 | 750 ₹18,000 | 340 ₹8,160 Lowest | 500 ₹12,000 | 450 ₹10,800 |
| 8.00 | All as per item No. 7 here-in-before but of size 50mm bore. | 24 | RM | 200 ₹4,800 Lowest | 500 ₹12,000 | 240 ₹5,760 | 350 ₹8,400 | 370 ₹8,880 |
| 9.00 | All as per item No. 7 here-in-before but of size 40mm bore. | 24 | RM | 150 ₹3,600 Lowest | 400 ₹9,600 | 215 ₹5,160 | 300 ₹7,200 | 320 ₹7,680 |
Tender Value
₹45.0 L
EMD Value
₹89,900
Closing Date
26 Jan 2026, 6:00 pmClosed
GE (AF) Hakimpet
Secunderabad
REPAIR AND REPLACEMENT TO LT NETWORK, INSTALLATION EARTHING AND ALLIED WORKS IN TECH / DOMESTIC AREA AT AFS HAKIMPET UNDER GE (AF) HAKIMPET
2026_MES_747220_1
8896/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hakimpet
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Hakimpet
₹89,900
Yes
16 Mar 2026
5 Jan 2026
28 Jan 2026
5 Jan 2026
26 Jan 2026
19 Jan 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: GE (AF) HAKIMPET
Name of Work: REPAIR AND REPLACEMENT TO LT NETWORK, INSTALLATION EARTHING AND ALLIED WORKS IN TECH / DOMESTIC AREA AT AFS HAKIMPET UNDER GE (AF) HAKIMPET
Contract No: GE/AF/HKPT/ OF 2025-2026 (8896/E8) SERIAL PAGE NO.
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT TOTAL AMOUNT In Words
1 Note : 1. Contractor need to purchase minimum 50% of all items mentioned in this CA within 20 days of getting sample approval and kept in custody so that no delay in work due to non-availability of materials will be faced. Contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of item/date. 2. Contractor should buy the exact items which are given with catalogue reference. Other makes will be approved only by submitting non availability Certificate Company. Contractor need to remove all the dismantled items without delay. 3. Rate quoted for demolition/dismantling /taking down is inclusive of removing the same from site and dumping at given locations anywhere inside station. 4. Contractor will make his own arrangement to store his items. 5. Some places in this contract where the vehicle will not reach the spot directly, the material will be moved manually in these places. The rate quoted will be considered all inclusive on this account. 6. All trade skilled labour required in this contract shall be present daily in working hours, irrespective of complaints received. 7. Complaint for a similar items may be in scattered / different area, quoted rate will be considered all inclusive on this account. 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
1.01 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard/dense soil for laying of cables/ for erection of poles/ for stay assembly etc complete all as specified and directed by Engineer-in-Charge. Cum Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
15 All as per item No. 10 here-in-before but of size 70 Sqmm, 3.5 core RM Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
19.01 Note:- (i) The unit rate shall include for GI water pipe, protection pipe wire mesh, funnel, excavation, RCC pit cover, PCC, test point, G I strip 32 X 6 mm from top of earth plate upto 5 mtr (ii) PCC pit shall be provided at least 1.5m away from the earth pit and extra cost of additional length of water pipes and fixing junction, Elbows etc. shall be deemed to be included in the unit rate. (iii) RCC pit cover shall be percast of RCC 1:2:4, type B-1, 80 mm thick reinforced with XPM weighing not less than 4kg/Sqm in liue of cast iron cover. 2 Construction of chamber for 100mm sluices valve item3 10 Nos
24 M&L MCCB 4 Pole, current rating 250 Amp, microprocessor based, thermal setting adjustable 70%-100% breaking capacity 36kA at 415V,50Hz. Including both side spreader (Make : (Make : Havells/Indoashian /L&T/ Standard). Each Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
45.01 (a) Aluminium bus bar of capacity 400 Amp with heat shrinkable coloured PVC sleeve insulation mounted on suitable insulators for 3 phases and half of the capacity for neutral - 01 Set (b) MCCB, 250 Amps, 4 Pole,36 KA microprocessor based-01No.(incoming). (c) MCCB 100 Amp 4 Pole 25 KA - 03 Nos (Outgoing) (d) MCCB, 160 Amps, 4 Pole, 36 KA - 02 Nos (outgoing) (e) Change over switch 250 Amps, 4 Pole, 36 KA - 01 Nos. (f) Digital Voltmeter 0-500 Volts range with selector switch - 01 No. (g) Digital Ammeter 0-500 Amps range with selector switch and CTs - 05 Set (h) LED type pilot indicator lamps for R,Y,B phases - 01 Set of 3, Hardware of panel board including bolt, nuts gaskets etc. (j) Errection, testing & commissioning including PCC foundation blocks of 2x PCC block of size, 500mm x 300 mm x 100 mm for grouting of panel as directed by Engr In Charge - 01 Job Note:- Drawing will be approved by the accepting officer before placing demand to the manufacture. 2 Construction of chamber for 100mm sluices valve item3 10 Nos
46.01 (a) Aluminium bus bar of capacity 1000 Amp with heat shrinkable coloured PVC sleeve insulation mounted on suitable insulators for 3 phases and half of the capacity for neutral - 01 Set (b) MCCB, 630 Amps, 4 Pole, 36 KA microprocessor based-01No (incoming). (c) MCCB, 250 Amps, 4 Pole, 36 KA - 01 Nos (Outgoing) (d) MCCB 160 Amp 4 pole 25 KA (outgoing) - 02 Nos (e) MCCB 100 Amps, 4 Pole, 16 KA - 02 Nos. (f) Digital Voltmeter 0-500 Volts range with selector switch - 01 No. (g) Digital Ammeter 0-500 Amps range with selector switch and CTs - 05 Set (h) LED type pilot indicator lamps for R,Y,B phases - 01 Set of 3. Hardware of panel board including bolt, nuts gaskets etc. (j) Errection, testing & commissioning including PCC foundation blocks of 2x PCC block of size, 500mm x 300 mm x 100 mm for grouting of panel as directed by Engr In Charge - 01 Job Note:- Drawing will be approved by the accepting officer before placing demand to the manufacture. 2 Construction of chamber for 100mm sluices valve item3 10 Nos
47.01 (a) Aluminium bus bar of capacity 600 Amp with heat shrinkable coloured PVC sleeve insulation mounted on suitable insulators for 3 phases and half of the capacity for neutral - 01 Set (b) MCCB, 315 Amps, 4 Pole, 36 KA microprocessor based-01No.(incoming). (c) MCCB, 100 Amps, 4 Pole, 16 KA - 03 Nos (Outgoing) (d) MCCB 160 Amps, 4 Pole, 25 KA - 02 Nos. (Outgoing) (e) MCCB 63 Amps, 4 Pole, 16 KA - 01 Nos. (Outgoing) (f) Digital Voltmeter 0-500 Volts range with selector switch - 01 No. (g) Digital Ammeter 0-500 Amps range with selector switch and CTs - 06 Set (h) LED type pilot indicator lamps for R,Y,B phases - 01 Set of 3 Hardware of panel board including bolt, nuts gaskets etc. (j) Errection, testing & commissioning including PCC foundation blocks of 2x PCC block of size, 500mm x 300 mm x 100 mm for grouting of panel as directed by Engr In Charge - 01 Job Note:- Drawing will be approved by the accepting officer before placing demand to the manufacture. 2 Construction of chamber for 100mm sluices valve item3 10 Nos
50.01 (m) Sensor Interface Support: (i) Tilt Sensor : Digital Tilt sensor with Modbus protocol : ZCT1360J (ID-5& Baud Rate 9600) DYNAMIC TILT Sensor (ii) Wind Sensor : Analog Type Output 0 to 10V or 40 to 20mA (iii) Main Controller/SCADA Interface: Yes, via RS485 - MODBUS RTU format (iv) Communication Interface : RS232 (v) Integrated debug : Yes, on External HMI display (n) Electrical Data (i) STC Power Supply : Max, 40V DC Supply (o) Environmental Data (i) Operating Temprature (Ambient) Range : -20 degree C to + 60 degree C (p) Mechanical Data (i) Product Dimentions (LxBxH) - in mm : 400 x 300 x 150 (ii) Product weight : 3 Kg Complete all as specified and directed. 2 Construction of chamber for 100mm sluices valve item3 10 Nos
51.01 Note : (i) Inspecting/ overhauling of manual/ motorised spring drive mechanism by checking mechanism, motor and gear assembly, gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, motor cut-off limit switch, replacement of damaged control wiring DC/ AC for smooth function of ACB, testing of contact resistance, insulation resistance and apply multi grease lubricant to function smoothly. (ii) Inspecting/ overhauling/ cleaning, by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (iii) Assembling all items/ components parts to the respective position & testing the breaker and meggering before and after high voltage test complete. (iv) All test to be conducted infront of Engr-in-Charge or rep of Engr-in-Charge and all reports to handed over to Engr-in-Charge for further record 2 Construction of chamber for 100mm sluices valve item3 10 Nos
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
BOQ_836755.xls
BOQ • 0.68 MB
8896ps.pdf
Tender Documents • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .