Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-Finance | L1 | Accepted-Finance Quoted as per NIT conditions. | |
| 2 | L2₹18.4 L+₹3.1 L (20.4%)Accepted-Finance 79 2 10TH B CROSS AYYAPPA TEMPLE ROAD GUDDADAHALLI HEBBAL R T NAGAR POST BENGALURU 560032 | BENGALURU | BENGALURU URBAN | KARNATAKA | 560032 | L2 | Accepted-Finance Quoted as per NIT conditions. |
Tender Value
₹14.2 L
EMD Value
₹28,450
Closing Date
17 Jul 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Head SE and M
NCBS, Bangalore
Proposed Remodification of existing spaces to facilitate Dr.Abhilasha at 1st floor of ELC and behavior and procedure room at 1st floor of Vivarium at NCBS campus Bangalore
2024_DAE_810704_1
NCBS/Maint(civil)/NIT-188
Open Tender
Civil Works
Works
90 days
NCBS, Bangalore
As per NIT
3 documents required · 3 mandatory
₹0
₹28,450
Yes
NCBS, Bangalore
8 May 2025
10 Jun 2024
18 Jul 2024
10 Jun 2024
17 Jul 2024
12 Jul 2024
10 Jun 2024 - 3 Jul 2024
4 Jul 2024
Amount
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
Removing white or colour wash by scrapping, sand papering the surface smooth including necessary repairs, etc complete.
Providing and applying PLASTER OF PARIS PUTTY (BIRLA PUTTY) of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Charges for powder coating on existing aluminium pherpharals including loading, unloading, transport charges and necessary covering after power coating.
Refixing/re-erecting the aluminium partition sections as a door, window,panels etc., with available aluminium sections and fixing the available boards and glasses stacked in storage shed including necessary rubber gaskets, hardware, tools, labour etc., complete
Providing and fixing at all height in all floor with all lead Seamless type M/F Suspended False Ceiling of calcium silicate board using GI perimeter channel of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with erimeter of ceiling, screws fixed to brick wall / partition with the help of nylon sleeves and screws at 610mm centres. Then suspending GI intermediate channels of size 45mm (0.9mm thick with two flanges of 15mm each) from the soffit at 1220mm centres with ceiling angle of width 25mmx10mmx0.5mm thick fixed to soffit with GIcleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction of perpendicular to the intermediate channel at 5\457mm centres. 12.5mm tapered edge gypboard (conforming to IS: 2095) is then screw fixed to ceiling section with 25mm dry wall screws at 230mm centres. Screws fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards of 15 mm thick gyp board are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for gypboard including providing scaffolding and executing the work at all heights. (Please refer drawing for details and recommended practices of India Gypsum or equivalent). NOTE: For lightingfittings, grills diffuses and cut-outs etc., have to be made with the frame of perimeter channels of size 20mm x 27mm x 30mm x 0.55mm thick supported suitable and should be considered as per drawing.
Modular panels work
Supply installation Testing & Commissioning (SITC) of wall panels made up of GI powder coated of 0.6mm thick sheet on both sides, with 50mm thick class 'O' PUF of min. 40kg/m3 density sandwitched in between. The GI sheet shall have 80 micron thick powder coating by hot dipgalvanizing with zinc coating not less than 180gm/sqm both side of the panel. Scope includes bottom runner, interconnecting profiles, fixing arrangements, silicon sealant application and all other accessories required to complete the work as per site requirement. Colour: Powder coated as approved by NCBS, complete with all necessary C-channels for bottom track and liight cutout covering, Aluminium 3D corner piece, External coving, hardware, accessories, fittings and fixtures, as per description in individual items, technical specifications, drawings and instructions of the Engineer-Incharge .Note:Necessary cut-opens to be made for service outlets , light fittings & HAVC fixtures etc and finished with required channels, chair angle, Internal & External perimeter Belting,PCGI Strip and C Flashings after passing/fixing the service outlets and light/HAVC fixtures. a shop drawing should be provided by agency before making production for approval and execution for both partition and door items.
Supply installation testing & commissioning (SITC) of modular sandwiched doors with both side GI powder coated, GI sheet construction 0.6mm thickness duly flushed with the walls, with 45mm thick PUF, sandwiched between GI sheets, with door frame, including flushed hinges, SS 304 handle / push plates and hydraulic door closers. General construction drawing to be attached, but frame width and leaf width to suit the site conditions. Drawings attached are for guidance purposes only, complete with all necessary hardware, double glazed view panels as per size required at site,accessories, fittings and fixtures, as per description in individual items, technical specifications, drawings and instructions of the Engineer-Incharge. Single leaf door: 1170 X 2100mm Measurement to suit the site conditions should have sliding arrangements like channels,wheels & operating gears.view panels (300 W X 600 H)/as per requirement at site.
Supply and installation of aluminium coving R50 mm redius wall to wall and ceiling to wall as per manufacturer specification and as directed by EIC etec complete.
Providing Core Cutting for walls/ for slabs of various dia including necessary finishing and cleaning as directed by Engineer In-Charge. For dia 40mm/50mm/63mm/75mm upto 300mm depth
Supplying and fixing HYDRAULIC DOOR CLOSER conforming to IS 3564 Everite/ozone or equivalent make of size specified below, inclusive of making adjustments and sorting it for smooth operation, etc.; complete all as per specifications. Size 3 (To carry a door width up to 1000mm)
Supplying and fixing MORTICE LOCK 6 levers 100mm conforming to I.S 2209 'Godrej' or equivalent make, straight edged bevelled or rotated as required, right or left handed as directed, suitable either to single or double leaf shutters including making necessary recess in shutter and fixing the mortice lock with aluminium anodised steel screws, etc.; complete all as per specifications.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (SDR 11) conforming to IS: 15778, having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and cost of cutting chases and making good the same with Cement Mortar 1:3, including testing of joints complete as per direction of Engineer-in-charge etc., for CONCEALED WORKS with: CPVC pipes, 25mm outer dia
Providing and fixing rigid PVC SWR (soil, waste and rain water) drainage / rain water pipe conforming to Type-A IS: 13592, including accessories like bends and fixing with pipe clips, adhesive at joints all as per manufacturer's specifications to required length etc., complete all as per specifications and directions of Engineer-in-charge. 75mm dia OD pipes with minimum wall thickness of 1.80mm
Painting INTERNAL plastered surfaces with TWO or more coats of PREMIUM SUPER ACRYLIC EMULSION PAINT of approved brand and colour (Asian or Berger or equivalent) to give an even shade with required finish over a coat of water thinnable cement primer including cleaning the surfaces, filling the crevices with approved filler, applying a coat of approved putty on whole surface and rubbing the surface to achieve desired smooth surface, scaffolding, etc., complete all as per specifications and directions of Engineer-incharge.
Providing and finishing TWO or more coats with EPOXY PAINT at all locations prepared & applied as per manufacturer's specifications including one coat of epoxy primer and filling crevices with approved epoxy putty, preparation of surface, scaffolding etc., complete.
Painting WOOD / STEEL WORK with ONE or more coats of SYNTHETIC ENAMEL PAINT of first quality and approved colour to give an even shade including cleaning the surfaces, filling the crevices with approved filler, scaffolding, etc.;complete all as per specifications.
Disposal of surplus excavated earth/ moorum / building rubbish / malba / similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, for lead upto 10km for all lifts, complete all as per directions of Engineer-in-charge. Note: Item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5cum or more.
Providing and laying 2mm thick ANTSTATIC POLYVINYL SHEET manufactured by M/s. Inidana International Pvt ltd. or equivalent on a smooth & damp proof base using rubber based adhesives (@ 0.2kg/sqm) of approved quality and manufacturer like Dunlop S- 758, Fevicol SR-998 or equivalent includingcleaning, levelling, drying of the base, rolling with light wooden roller weighing about 5.00kg including providing copper strip of size 15mm x 2mm for earthing etc. all complete as per specification and the directions of the engineer-incharge and having the following properties for the sheet: (1) Electrical Resistance - Anti-Static flooring range 5x104 - 108 Ohms, conductive flooring range up to 5 x 104 Ohms. (2) Flexibility - Does not break, crack or any sign of failure. (3) Heat Ageing & Exudation - No visible effect or exudation. (4) Fire resistance - Does not support combustion or assist spread of flame. (5) Water absorption - less than 0.1%. (6) Sound reduction factor - 2mm - 3 db.
Repolishing the existing terrazzo tile / cast-insitu looring / dado including finishing with oxalic acid, cleaning, etc.; complete.
Door Frame and Shutter work
Providing seasoned TEAK WOOD of class specified below in frames of doors, windows, ventilators and other frames etc.; wrought, framed and fixed in position with 2 nos. of 8mm dia anchor fasteners or 1 no. of 12mm dia anchor fastener embedded in cement concrete blocks of size 345 / 230 / 115mm x 230mm x 150mm in PCC 1:3:6 mix (cement : fine aggregate as per IS: 383 : graded hard stone aggregate) for wall locations. Further if the frames are butting to the RCC / PCC columns / mullions, 8mm dia anchor fastener shall be provided instead of hold fasts or with M.S bolts / T.W plugs and G.I. screws as required including tarring back of the frames, etc.; complete all as per specifications. Maximum permissible moisture contents in timber as per IS: 287 shall not exceed 12%. Using SECOND CLASS seasoned TEAK WOOD
Supplying and fixing solid hard core NONDECORATIVE type (BN) interior grade commercial BLOCK BOARD FLUSH DOOR SHUTTERS of approved make conforming to IS: 2202 (Part-I) with teak wood internal lipping on all sides and solid teak wood inserts for mounting locks, etc.; having well matched commercial ply veneering with cross bands and face veneers on both faces, including cost of labour for fixing builder's hardware and locking arrangement etc.; complete all as per specifications but excluding cost of builder's hardware and locking arrangement issued with screws by the department free of cost. NOTE: Samples as stipulated in IS should be furnished for tests free of cost by the contractor as the tested samples are destroyed during testing. Double shutter 35mm thick
Add extra for providing vision panel of size 0.25x0.60 in all types of flush door shutters of all thicknesses including cost of 3.5mm to 4.0mm thick plain glass and internal first class T.W. beading 20x10mm on both sides of glass vision panel. (Overall area of door shutter to be measured). Rectangular or square
Supplying of Anodised aluminiumTower bolts (Barrel type) as per IS 204:1974, Barrel dia11mm, bolt dia 10mm
Supplying of Butt hinges( stain less steel type) of size 125mm x 65mm x 2.12mm
Providing and fixing best quality of regular decorative laminated sheet 1.00mm thick Mica or equivalent, matt finish, of approved colour conforming to IS: 2046 code and with ISI mark, fixing to flush shutter, etc.; using adhesive fevicol - SH or equivalent, complete all as per specifications and direction of the Engineer- in-charge.
Providing skilled Carpenter service with necessary tools and machinery for various wooden Joinery and Aluminium joinery works like fixing AC Grills, mainteance/service for existing carpentry fixtures including necessary works and as directed by EIC.,
Providing and fixing 12mm thick flat pressed three layered wood based melamine faced prelaminated particle board bonded with Phenol formaldehyde with a decorate laminate of same colour on both sides - NOVOPAN PLT / BHUTAN BOARD/ ARCHIDPLY/ GREENLAM - Exterior grade or equivalent, including cutting to required size and shape, fixing with aluminium glazing clips or triangular beading (measured and paid under item elsewhere) including screws, putty etc., complete.
Providing and constructing BRICK MASONRY in cement mortar as per mixes stipulated below using approved well burnt bricks of class designation (Classification as per IS: 1077) as specified below including raking out joints 10mm deep, scaffolding, curing, etc.; complete as per specifications IN SUPERSTRUCTURE UPTO FLOOR FIVE LEVEL. (The mix ratio specified is for Cement : fine aggregate (Uncrushed sand by natural disintegration of hard stone / rock from streams or glacial sources as per IS: 2116)) Using BRICKS of class designation '3.5' (minimum average compressive strength not less than 3.5N/sqmm) in cement mortar 1:5
Plastering 12mm thick with cement mortar specified below, finished smooth with lime neeru, including scaffolding, curing, etc.; complete for INTERNAL SURFACES of walls, beam, ribs, sills, jambs, ceiling, etc.; complete all as per specifications UPTO FLOOR FIVE LEVEL, mix specified is for cement : fine aggregate as per IS: 1542. With CM 1:6 (Cement: Fine aggregate (Uncrushed sand by natural disintegration of hard stone / rock.
Dismantling tile work in floors / roofs / dado laid in cement, including demolishing the cement mortar, including stacking material within 50m lead for thickness of tiles 10mm to 25mm.
Demolishing BRICK / CC BLOCK WORK in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50m lead.
Carful Dismantling of Existing High bench and work Bench fabricated with powder coated MS Sections of size 25mmx25mm, having 20mm tk polished granite slabs as table top, laminated wooden Reagent shelves erected on 20x20mm tk Powder coated MS sections,dismantling of existing water supply/oulet lines including shifting to storage yard with lead up to 100mtrs as directed by EIC.
Providing and fixing of Sink Faucet of approved brand and make suitable for laboratory sinks including necessary connection hose and fixtures etc., complete and as directed by EIC
Providing and fixing of Eye Wash of Approved brand and make suitable for laboratory sinks including necessary connection hose and fixtures etc., complete and as directed by EIC
Providing and fixing of Foot operated valve - paddle type JAL make CP 15mm including necessary hose connection pipes suitable for laboratory sink faucets etc,. Complete and as directed by EIC.
FILLING OF CRACKS, voids and pores in concrete members using low viscosity epoxy resin CONCRESIVE 1315 AND EPOXY PUTTY CONCRESIVE 2200i with the following procedures: 1) Clean the cracks using wire brush and take grooves along cracks using machines. 2) Drill 12mm dia holes using drilling machine up to 1 / 3rd depth of concrete member and fix injection. Ports at 200mm c/c distance on the crack groove and other areas capped with concresive 2200i epoxy paste. Leave it for cure. 3) Mix two component concresive 1315 using mechanical paddle till homogeneous paste obtained. Inject the mix through the injection hole using electric pump till the resin flow from other hole. Continue the process for other holes. NOTE: Rate quoted shall include cost of tools & plants, transportation and taxes etc.
Painting plastered surfaces with TWO or more coats of water based EPOXY POLYURETHANEPAINT of first quality manufactured M/s. CIPY Polyurethane Pvt Ltd. or Equivalent approved make and colours to give a even shade as per Asian or Berger colour bank with a neat finish over a surface prepared by removing all loose particles, dust and protrusions and applying neutralise coat to take care of deliminatations due to alkalinity of substrata by neutralising the cement plastered surface, acrylic putty is applied over the above surface to give smooth backing for the paint over the surface thus prepared water based two component polyurethane primer is applied to obtain a compatible surface for good adhesion of two coats of ultra-high performer ultra violet resistant epoxy polyurethane coat etc., complete at all heights including scaffolding.
Providing and laying self levelling Antistatic Hard Epoxy Flooring (glossy) (ESD flooring) using NITOFLOR SL DISSIPATIVE of approved colour of M/s. FOSROC Chemicals or equivalent by preparing the surface of floor by any mechanical means to obtain the profile of CSP 4 to CSP 6 as per ICRI guidelines followed by vacuum cleaning to receive the flooring and laying the floor having the following specifications and as per directions of Engineer in charge. (a) Compressive strength shall not be less than 50Mpa at 7days as per BS 6319. (c) Providing a copper tape of 100 micron thickness and 25mm which shall be embedded all around the static dissipative flooring and this copper strip shall be earthed independently or through the special copper earthing provided on wall. (b) Surface resistivity in case of static dissipative type is between 10 to the power of 6 and 10 to the power of 9ohms when measured for surface resistance in accordance with ASTM F150. (The minimum value shall not be less than 10 to the power of 6ohms). (d) The thickness of flooring shall be as per manufacturers specification meeting the above stringent requirement and shall not be less than 2mm. The above flooring material shall be as per the manufacturers specifications satisfying the above properties and specifications and may be from one of the following manufacturers viz., M/s. FOSROC Chemicals (I) Ltd., or equivalent. Note: 1. The contractor shall prepare a sample panel of size 3.0x3.0m flooring of any of the above manufacturers and get it approved by the department free of cost. After the panel floor passes all the testing standards, the work shall be carried out. The sample work shall be carried out well in advance and got approved.2. The surface resistance to be measured using megger meter after laying under coat and top coat by the agency executing the work without any extra cost.3. Test certificate from Central Power Research Institute should be produced at the time of laying the sample flooring and the test values shall conform to the specifications mentioned above and after the completion of sample area should again be tested and satisfied.4. All laying procedures should conform to manufacturers specifications which may have to be got approved from Engineer in charge before starting the work.5. Guarantee for the performance of work irrespective of antistatic and other specified parameters should be furnished for 10 years. 6. The work must be carried out only by a reputed firm, who have the experience of having carried out similar works satisfactorily which will be inspected by the Engineer in charge and only after his specific approval, the work shall be executed.
CRS AND COMPANY
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .