HQ Chief Engineer Delhi Zone Delhi Cantt-10
ADDN ALTN AND UPGRADATION TO BLDG NEW NPG LINE ORS QTRS JCOS QTRS AT OLD NPG LINE AND CIV QTRS JCOS QTRS AT HAZIPIR LINE QTRS UNDER GE WEST DELHI CANTT 10
2024_MES_682751_1
CEDZ/TOKEN-21 OF 2024
Open Tender
Civil Works
270 days
Delhi Cantt-10
As per NIT
10 documents required · 10 mandatory
₹2,000
GE West
₹4.8 L
Yes
7 Nov 2024
7 Nov 2024
29 Jun 2026
17 Apr 2026
25 Jun 2026
18 Jun 2026
er strong (Product no. 201) of chowgale building chemicals or equivalent pidlite/Drfixit/sika/phosrock, complete all as specified and directed Method of Application Methodology (a) The surface must be sound , absorbent, clean, free of dust, oil, paint, curing agents , loose cement or lime plaster & concrete, debris, or any separation layers. (b) The plaster must be knocked off at least 50cm beyond the visibly penetrated area. (c) Damaged mortar joints are to be scraped out to a depth of approximately 2-3 cm. All sharp edges/joints need to be levelled ; loose concrete to be removed. (d) Drill boreholes at ground level horizntally. The boreholes are drilled horizontal into the masonry. (e) The holes should be drilled until a depth of approx 5cm (for a 6cm thick wall) before the end of the wall is reached. The boreholes should have a diameter of 12mm upto a maximum of 15mm and should be spaced approx 100-120mm apart and the vertical offset is 6cm maximum. (f) Before inserting rising bar super strong or equivalent the boreholes must be clean from boring dust by using air pressure. It is not necessary to pre-wet the boreholes. (g) For applying of rising bar of super strong or equivalent the dosing system inserted as far as possible into the bore holes. While dosing the product uniformly, the injection nozzle is pulled out leading to a completely filled boreholes (h) Treatment of highly absorbent masonary mught required repeated filling of the boreholes. depending upon extent of damage, rising bar superstrong or equivalent can be re-injected into the same hole after 24 hrs. depending on observency, application or masonry thickness 0.1 to 0.15 ltr/m with 10cm wall thickness.#3!M&L for Preventive treatment against the danger of carbonation in exposed faces of RCC members :- (i) Cleaning existing surfaces of RCC members and making surface free of loose material, oil, grease etc. by vigorous wire brushing including light grit blasting where necessary as recommended by Engr-in-charge. (ii) Further, cleaning using biocide (as recommended by manufacturer) to ensure that surface is free of algae and fungus and no trace of paint (any type) left out. Sand blasting to be done to remove trace of paint. (iii) Cleaned surface to be allowed to dry. (iv) Spray a coat of primer (as recommended by manufacturer) over dry cleaned surface as required prior to final finish. Primer shall be diluted in proposition 2:1 with mineral turpentine. After application, primer shall be allowed to dry for 03 hours or as directed. (v) Apply a coat of neat Aliphatic Acrylic anti-carbonation (ACC) over the primed surface with air / spray gun at nominal rate of 3.5 ltrs per sqm as recommended by manufacturer. (vi) Apply a more coat of Aliphatic Acrylic anti-carbonation (ACC) after 5-6 hours as recommended by manufacturer complete all as specified and directed.úM&L for use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete, complete all as specified & directed.iM&L for use & waste of form work using steel sheet, steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period, complete all as specified and directed. Note : Form work shall be 100% leak proof. For purpose of payment area in touch with concrete shall be measured. ö#ú!nAll as per item No.140 above but 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders.S&F FRP chajjas of 450mm wide suitable for various openings including fittings and fixtures upto 4 storey bldg complete all as specified and directed.jRefixing of balcony grill without damage including welding, cleaning rust and apply zink primer and fixing at same place without any damage to existing structure etc complete all as specified and directed. Note : The cost of dismantling of all balcany grill up to 4 storey building without any damage and refixing at same place is deemed included in this item.Ð#Ô!íM&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. including brushing neat cement slurry with 3.0kg of cement per sq. Metre, complete all as specified & directed.ÈM&L providing pre cast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in kitchen slab, passage roof etc and set in cement mortar 1:4, complete all as specified & directed.öM&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of syntethic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified & directed.S&F brass CP mixer swivel spout for mixing hot & cold water for sink, screwed down for 15mm bore pipe or ferrul, complete all as spd & directed.
S&F for stengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
BoQ_Ver3.0
Bidder Name :
SCHEDULE 'A' PART-II (INTERNAL ELECTRIFICATION) PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
M&L for concealed point wiring with PVC insulated unsheathed multistranded colour code copper conductor in PVC conduit with FRLS cable 1.5 Sqmm size 1100 volts grade conforming to IS:694 in new metal flush box of 1.6 mm thick including one coat of synthetic enmelled black paint and providing with brass screws and cup washers including single core multi stranded FRLS copper conductor 1.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit, complete all as specified and directede for the following :-
(a) One light/ fan/ bell point controlled by controlled by one, one way switch .
(b) One 3 pin 5 Amps socket outlet point controlled by one, one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one, one way switch on same board.
(d) One light point controlled by two Nos two way switches 5 Amps.
M&L for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 2.5 Sqmm size 1100 volts grade conforming to IS:694 in new metal flush box of 1.6 mm including one coat of syenthetic enamelled black paint fixed with brass screws and cup washers including single core multi stranded FRLS copper conductor 2.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit for one 3 pin socket 15A on Indepentent board, complete all as specified & directed.
S&F Switch piano flush type 6 Amps, single pole one way, complete all as specified & directed.
S&F Switch piano flush type 16 Amps, single pole one way, complete all as specified & directed.
S&F of socket outlet multipurpose 3 pin 6 amps flush button type, complete all as specified and directed.
S&F of socket outlet multipurpose 2 in 1, 6 and 16 Amps with safety shutter, complete all as specified and directed.
S&F LED B22 1x 12 W, 220V, AC LED lamp decorative wall mounting light fitting fixture made up of Aluminum body including LED 12 watt with System level efficacy of the Luminary is >= 100 lm/W, Color Temperature-6500K, including connecting up with necessary PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed, complete all as specified and directed.
S&F of Lamp holder, PVC /Polycarbonate type with back plate suitable for batten fittings with connections, complete all as specified and directed
S&F in repairs LED bulb of 9 watt (B-22),with lumen efficacy>=90 lm/W, Color Temperature-6500K, complete all as specified and directed.
Taking down carefully existing sub main wiring with aluminium conductor/copper conductor cable of any size with GI earth wire including wooden batten etc and making good disturbed surface of walls etc, complete all as specified & directed.
Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated, FRLS, unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection, complete all as specified and directed. Note : Three runs of copper conductor 6.0 sqmm including PVC rigid conduits will be measured and paid as one unit only.
Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 4.0 sqmm (Main Cable and neutral) and one run of IC x 4.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated, FRLS, unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed. Note : Three runs of copper conductor 4.0 sqmm including PVC rigid conduits will be measured and paid as one unit only.
Supply, installation, testing and commissioning of 1200mm sweep BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, Class of insulation : B, power factor not less than 0.9, service value (CMM/W) minimum 6.85, not less than 350 RPM (tolerance as per IS:374-2019), THD less than 10%, including electronic regulator unit for speed control and all remaining accessories including safety pin, nuts bolts, washers, temperature rise =75 degree C (maximum), insulation resistance more than 2 mega Ohm, suitable for 230V, 50 Hz, single phase AC supply including taking down old ceiling fan and depositing to MES store yard, complete all as specified and directed.
S&F single pole MCB 40 Amps, 240 v, 50 Hz AC made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IEC-60898-1:2002 including taking down old MCB's, complete all as specified and directed.
S&F SPN MCB 40 amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity, complete all as specified and directed.
S&F surface mounting LED building security light fitting fitted in high pressure die cast aluminium housing not less than 35W including fabrication of GI bracket 25mm dia suitable for fixing of LED light fitting duly fixed with clamps, nut bolts & washer etc, fixture should have minimum efficacy at system level >=100 lumens/Watt, life of fixture not less than 50K Hrs, Ripple<5%,UGR<19, minimum Surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95 ,THD<10% @ 240v Ac with IP 66 protection, operating voltage range of 140-270V including all connection upto ceiling rose, complete all as specified and directed.
S&F ceiling rose 3 phase/PVC/polycarbonate isolated body, complete all as specified and directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
uploadtender83119.rar
Tender Documents • 2.13 MB
BOQ_764008.xls
BOQ • 0.93 MB
Download all tender documents and submit your bid