Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 CrAccepted-AOC 1077 SECTOR 16 AND 17 125001 R55 | HISAR | HISAR | HARYANA | 125001 | ₹34.7 Cr | L1 | Accepted-AOC Allotted |
| 2 | L2₹34.7 CrRejected-AOC H NO 66 SECTOR 27A CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | 160019 | ₹34.7 Cr | L2 | Rejected-AOC NA |
| 3 | L3₹36.7 CrRejected-AOC | ₹36.7 Cr | L3 | Rejected-AOC NA |
| 4 | L4₹39.0 CrRejected-AOC | ₹39.0 Cr | L4 | Rejected-AOC NA |
| 5 | L5₹40.2 CrRejected-AOC BOOTH NO 53 MAIN MARKET KITCHLU NAGAR LUDHIANA PUNJAB 141001 | LUDHIANA | PUNJAB | 141001 | ₹40.2 Cr | L5 | Rejected-AOC NA |
Updated dates
Tender Value
₹45.7 Cr
EMD Value
₹91.3 L
Closing Date
29 Dec 2025, 10:00 amClosed
EE National Highway Division pwd B and R Ferozepur
EE National Highway Division pwd B and R Ferozepu
Upgradation of Plan Road Ferozerpur Jalalabad road SH.20 from Km. 2.00 to 48.00 for the financial year 2025.26 under Special Assistance FY 2025.26 including maintenance of road for 5 years One Year Defect Liability plus Four Year maintenance Group.1
2025_CEPW_154387_1
Tender Notice No.11 dated 24.11.2025
Open Tender
Civil Works - Roads
270 days
EE National Highway Division pwd B and R Ferozepur
Please refer Tender documents.
4 documents required · 4 mandatory
₹50,000
₹91.3 L
EE National Highway Division pwd B and R Ferozepur
16 Feb 2026
26 Nov 2025
29 Dec 2025
26 Nov 2025
29 Dec 2025
26 Nov 2025
12 Dec 2025
Clearing Grass and Removal of Rubbish Clearing grass and removal of rubbish up to a distance of 50 meters outside the periphery of the area as per technical clause 201 of MORT&H specifications (CSR 24.1)
Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications (24.5 (a)
Slurry Seal Type-I (2-3mm thickness) Providing and laying slurry seal Type-I 2-3mm thickness consisting of a mixture of fine aggregates, portland cement filler, bituminous emulsion SS-2 @ 13% and water on a road surface including cleaning of surface, mixing of slurry seal in a suitable mobile plant, laying and compacting to provide even riding surface complete as per technical clause 512 of MORT&H specifications
Tack Coat @ 0.40kg per sqm Providing and applying tack coat with penetration grade bitumen VG-10 using bitumen pressure distributor at the rate of 0.40 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical specifications (24.16 b)
Providing and laying dense graded bituminous macadam 50mm to 75mm thick with batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder VG-40 @ 4.5%, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 505 of MORT&H specifications (24.20 (a) NOTES : - I. The actual volume of the aggregate to be paid for shall be computed after deducting the specified percentage from the volume computed by stacks measurement as per MORT & H specifications (addendum to latest revision) for the purpose of secured advance." II. The final grading for the aggregates required for bitumenious macadam course Grading 2 for 75 mm / 50 mm thickness of each layer conforming to table 500-7 of M.O.R.T. & H specifications (addendum to latest rivision) shall be determined after getting the bitumenious macadam grading-2 designed from Punjab PWD, B&R Research Laboratory Patiala after obtaining 60 % of material. The design mix so finally approved by shall be termed as the approved mix. The aggregates shall be hydrophobic and of low porosity. The aggregates shall satisfy the physical requirement set fourth in table 500-6 (addendum to latest revision). III. The mix shall exhibit the following details: a) Binder expressed as a percentage by weight of total mix. b) Coarse aggregate of 26.5 mm gauge expressed as percentage by weight of total mix. c) Crushed Bajri of 11.2 mm size expressed as percentage by weight of total mix. d) Fine aggregates 4.75 mm below expressed as percentage by weight of total mix. e) A single definite percentage passing each sieve for mixed aggregates. f) Density of Bitumensious macadam (75 mm/ 50mm thick after compaction) shall be minimum 2.2 gms/C.C & nothing extra shall be payable if higher density is achieved at site. IV) The Contractor thereafter, shall be required to complete the supply of various ingradients or Bituminous macadam as per proportions stipulated in the approved mix. V) Rate of B.M shall be quoted by the contractor with respect to binder content percentage by weight of mix being 3.4 % if Laboratory designs a mix with different percentage then the difference shall be payable / recoverable.
Bituminous Concrete 30mm to 45mm thickness (Grading II) Providing and laying bituminous concrete 30mm to 45mm thick with batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-40 @ 5.4%, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 507 of MORT&H specifications (CSR 24.23a) NOTES:- (i) Job mix formula for the bituminous concrete shall be provided by the agency and shall be got approved from Punjab PWD, B&R Research laboratory Patiala before adoption at site for execution. (ii) The specifications of this item for analytic purpose is kept with bitumen content @ 5.4% weight of mix variation as compared with job mix formula shall be paid/ deducted accordingly. The limits of variations shall be worked out with the approved formula. TECHNICAL NOTE:- i.) Apart from the conformity with the grading and quantity requirement of individual ingredients exhibited above the mix aggregate i.e. coarse and fine aggregate for bituminous concrete shall meet all requirements set forth clause 507 of MORT&H specifications. ii.) The final grading for the aggregates required for bituminous concrete confirming to table 500.17 of MORT&H specifications shall be determined after getting the bituminous concrete designed from Punjab PWD, B&R Research Laboratory Patiala after obtaining 60% of material. The design mix so finally approved shall be termed as the approved mix. The aggregates shall be hydrophobic and of low porosity. The aggregates shall satisfy the physical requirement set forth in table 500-6 (addendum to latest revision). iii.) The approved mix shall exhibit the following details, source and location of all material:- (a) Binder expressed as percentage by weight of total mix. (b) Course expressed as percentage by weight of total mix. (c) Crushed bajri expressed as percentage by weight of total mix. (d) Fine aggregate expressed as percentage by weight of total mix. (e) A single definite percentage passing each sieve for mixed aggregates (f) Density of bituminous concrete after compaction will be not less than 2.35 gm/CC.
Bituminous Concrete 50mm to 65mm thickness (Grading I) Providing and laying bituminous concrete 50mm to 65mm thick with batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-40 @ 5.20%, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 507 of MORT&H specifications (CSR 24.22a) NOTES:- (i) Job mix formula for the bituminous concrete shall be provided by the agency and shall be got approved from Punjab PWD, B&R Research laboratory Patiala before adoption at site for execution. (ii) The specifications of this item for analytic purpose is kept with bitumen content @ 5.2% weight of mix variation as compared with job mix formula shall be paid/ deducted accordingly. The limits of variations shall be worked out with the approved formula. TECHNICAL NOTE:- i.) Apart from the conformity with the grading and quantity requirement of individual ingredients exhibited above the mix aggregate i.e. coarse and fine aggregate for bituminous concrete shall meet all requirements set forth clause 507 of MORT&H specifications. ii.) The final grading for the aggregates required for bituminous concrete confirming to table 500.17 of MORT&H specifications shall be determined after getting the bituminous concrete designed from Punjab PWD, B&R Research Laboratory Patiala after obtaining 60% of material. The design mix so finally approved shall be termed as the approved mix. The aggregates shall be hydrophobic and of low porosity. The aggregates shall satisfy the physical requirement set forth in table 500-6 (addendum to latest revision). iii.) The approved mix shall exhibit the following details, source and location of all material:- (a) Binder expressed as percentage by weight of total mix. (b) Course expressed as percentage by weight of total mix. (c) Crushed bajri expressed as percentage by weight of total mix. (d) Fine aggregate expressed as percentage by weight of total mix. (e) A single definite percentage passing each sieve for mixed aggregates (f) Density of bituminous concrete after compaction will be not less than 2.35 gm/CC.
Wrought iron & Mild steel ladders, framed grills,gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position (CSR 18.4)
Cement concrete 1:2:4 With stone ballast or shingle mixing by manual means (CSR 10.13ai)
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Precast Cement Concrete Kerb providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications (CSR 24.41a)
Providing and making rumble strips 15-20 mm high at centre, 250mm wide placed at 1m centre to centre over freshly laid bituminous layer by using close graded premix surfacing material type B at approved locations to control speed. The close graded premix surfacing material type B shall conform to technical clause 512 of MORT&H specifications (24.62 b)
Hazard Marker sign board 300x900mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 09 and IRC 67 2012, fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground including foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012 (CSR 24.51a)
Road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 0.25kg per sqm area as per IRC:35 1997 complete as per technical clause 803 of MORT&H specifications
Providing and Fixing of Flexible Median Markers as per IRC 79:2019 which shall be made of combination of tough, high impact resistant molded thermoplastic body along with florescent yellow color retro-reflective type XI sheeting with minimum exposed reflective area 285 square mm and with rebound property. The reflective sheeting should confirm to Type XI Florescent Yellow sheeting as per IRC 67 2012 and ASTM D4956- 11. The flexible median marker shall have overall height of minimum 180 mm, body thickness of minimum 2mm and shank depth of minimum 30mm. The retro-reflective sheeting shall be on both sides of the Flexible Median Marker and shall be edge protected with no exposed edges which will prevent edge lifting, vandalism, sheeting damage, etc. The edge of sheeting should not come out easily by putting nails, sharp objects etc. The logo of the manufacturer shall be embossed on either side of the body. The product design has to with stand all natural impacts and should not get damaged if any pedestrian stamp on top of it intentionally or unintentionally. The product should bend up to 90 degree on both sides without breakage or damage. Each (CSR 24.64)
Supplying and fixing of single mould twin shank reflective road studs made out of polycarbonate/ABS moulded body and reflective panels with micro prismatic lens or Glass Beeds capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values shall be as given in the detailed specifications and the product shall conform to ASTM D4280. The raised pavement marker shall also meet all the testing conditions of ASTM D4280 and fixed to the road surface using the adhesive. Two cylindrical Polymer Shanks of not less than 20 mm diameter and not less than 30 mm length shall be molded in the RPM body. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. The marker shall withstand flexural strength of 909 kgf complete as per CSR 24.63
Advance Direction sign board 1200x900mm rectangular per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. grade sheeting fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on two square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground in foundation concrete M-25 of size 0.60x0.60x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 (b) Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012
Cautionary sign board 900x900x900mm triangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4mm thick aluminum Composite material (ACM) sheeting having aluminum skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suita
ble size aluminum alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laborator conforming to clause 6.7 of IRC 67-2012 (a) Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012
Mandatory sign board 900mm circular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. Fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/cto back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67- 2012 . (a) Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012 (CSR 24.45a)
Definition Plate 600x200mm rectangular as per as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012.specifications. Fixed over 3mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame welded with vertical post of sign board complete as per clause 801 of MORT&Hspecifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 . (a) Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012
Overhead sign board 12000x1500mm simply supported type double sided as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 . fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 40x40x6mm angle iron supported on designed double support system of MS pipe and plates in the form of a simply supported type truss made with 350NB pipe @50kg per mtr as vertical support, 50NB pipe @ 4.50kg per mtr and 40NB pipe @ 3.61kg per mtr for truss including base plates, gusset plates, designed RCC foundation for fixing in ground complete as per clause 802 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012. Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per AST
M D 4956 09 and as per IRC 67 2012
Overhead sign board 6000x1500mm cantilever type double sided as per IRC 67-2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012 fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 40x40x6mm angle iron supported on designed single support system of MS pipe and plates in the form of a cantilever type truss made with 350NB pipe @50kg per mtr as vertical support, 50NB pipe @ 4.50kg per mtr and 40NB pipe @ 3.61kg per mtr for truss including base plates, gusset plates,designed RCC foundation for fixing in ground complete as per clause 802 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67- 2012 .. (Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012 (CSR 24.52b)
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth (CSR 11.5)
12.5 mm thick cement plaster 1:4 (CSR 15.9)
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish (CSR 16.65)
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface (CSR 16.31)
Painting two or more coats excluding priming coat with synthetic enamel paints in all shades on wood work , metallic or plastered , concrete surface to give an even shade. (CSR 16.17)
Providing and fixing in all respects 24 hours light sensor control polycarbonate material solar blinker with flashing frequency of 50 times per minute having diameter of 300mm and 120 pcs of LED with 10 W solar panel and 12V / 7Ah battery. The solar blinker is to be mounted on pole having length of 2.5 m outside the ground level.
Ordinary Kilometer Stone for Plan Roads Reinforced cement concrete M-15 grade ordinary kilometer stone of standard design as per IRC 8-1980 fixing in position including painting and printing etc. complete as per technical clause 804 of MORT&H specifications (CSR 24.37a)
5th Kilometer Stone for Plan Roads Reinforced cement concrete M-15 grade 5th kilometer stone of standard design as per IRC 8-1980 fixing in position including painting and printing etc. complete as per technical clause 804 of MORT&H specifications (CSR 24.37b)
200 meter Stone Reinforced cement concrete M-15 grade 200 meter stone of standard design as per IRC 26-1967 fixing in position including painting and printing etc. complete as per technical clause 804 of MORT&H specifications(CSR 24.38)
Dismantling brick work tile, masonry or tile lining (c ) In cement (CSR 8.5c)
Dismantling concrete (e) Reinforced cement concrete (CSR 8.6e)
Dismantling concrete (a) Lime concrete, cement concrete of 1:6:12 or leaner mix (CSR 8.6a)
Taking out existing CC interlocking paver blocks from footpath/ central verge/pavement, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. (CSR 8.43)
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead (CSR 8.46).
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge (CSR 8.44)
Stripping and stacking iron sheets of a roof including ridging, flashing, eaves boards gutters and down pipes.(CSR 8.11)
Excavation in Soil (any type) using Hydraulic Excavator CK 90 Excavation with hydraulic excavator of 0.9 cum bucket capacity including cutting trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lift and combined lead up to 60 mtr. 24.6 (c)
Cement concrete 1:4:8 with stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type (CSR 10.11b(ii))
Reinforced cement concrete M-40 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (CSR 10.19 & AC 1)
Disposal of Rubbish (Malba) carriage upto 1km lead
Credit of Bricks (Store)
Credit of Brick bats from well burnt or burnt bricks.(CSR Ch. 3 M-12 (d)
Credit of street light pole
Credit of Toll plaza high mast light with pole
Traffic Light with pole (single)
OHLS Fited on Canopy
TLC box for barrier
Load cell
Credit of Scrap Steel in Dismantled RCC
Credit scrap of ACM sheets
Credit scrap of aluminium/ Gypsum partitions sheets
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
SBD.pdf
Tender Documents • 16.89 MB
BOQ_312965.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid