Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC 23 6 C LAL VIHAR EAST END BAMRAULI PRAYAGRAJ 211012 U P | PRAYAGRAJ | UTTAR PRADESH | 211012 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹5.3 L+₹11,610 (2.23%)Rejected-Finance 02 JAMEEWAR COMPLEX RING ROAD HANUMAN NAGAR GONDIA MAHARASHTRA 441614 | GONDIA | MAHARASHTRA | 441614 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹7.2 L+₹1.9 L (37.5%)Rejected-Finance BAKRABAD BAMRAULI ALLAHABAD U P | ALLAHABAD | U P | L3 | Rejected-Finance Being not lowest |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
20 Oct 2023, 6:00 pmClosed
Shri Pranav, AGE (I)
AGE (I) Manauri Allahabad-212212
REPAIR TO ROOF TREATMENT AND ALLIED WORKS IN OFFICERS ENCLAVE AND TECH AREA AT AF STN MANAURI
2023_MES_620135_1
9101/E8
Open Tender
Civil Works
Item Rate
182 days
Manauri
As per tender docs
7 documents required · 7 mandatory
₹500
AGE (I) AF Manauri
₹14,000
Yes
2 Dec 2023
22 Sept 2023
23 Oct 2023
22 Sept 2023
20 Oct 2023
7 Oct 2023
Amount
Demolition of brick work built in cement mortar including all quoions, arches pillar etc complete all as specified and directed.
M&L brick work with sub class "B" old size bricks, straight or curved on plan exec 6m mean radius built in CM 1:6 complete all as specified and directed.
Taking down cement plaster on brick/stone surface of wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick on fair face of brick walls or concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new surfaces and applying 2 coats of OBD over a coat of primer complete all as specified and directed.
M&L rendering 15 mm thick in cement plaster 1:4 with WPC (@ 3%by weight of cement) on fair faces of brick work or concrete surface finishing the surface even and smooth without using extra cement complete all as specified and directed. Note:- WPC shall be measured & paid seprately.
M&L for preparation of new surface of wall including cornices and apply two coat of cement based paint over a coat of primer etc complete all as specified and directed.
Supply only intergal water proofing compound complete all as specified and directed.
M&L in applying two coats of synthetic enamel paints over a coat of red oxide primer on old steel surfaces over 10 cm width or girth including preparatinon of surfaces complete all as specified and directed.
M&L in applying two coats of synthetic enamel paints over a coat of red oxide primer on new steel surfaces over 10 cm width or girth including preparatinon of surfaces complete all as specified and directed.
Dismantling timber scantlings 40 sqcm and over in section, in any position complete all as specified and directed.
M&L for Second class hard-wood in scantlings complete all as specified and directed.
M&L 2nd class hard wood plain fillets square, rectangular or trangular in section, clean sawn secured with nails or brads area exc 3 and n.exc 13 sqcm complete all as specified and directed.
M&L surfaces for two coat of synthetic enamel paint over one coat of zinc primer on wooden surface of any description n exc 10cm width or girth when unconnected with other painting or when painted in different tint on new wooden surfaces complete all as specified and directed.
M&L for PCC1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate), as in copping etc complete all as specified and directed.
M&L preparation of roof treatment with APP polymeric water proofing membrane all as given below:- (a) Taking down existing water proofing treatment and cleaning roof surface by washing and rubbing etc and removing retrieved material to a distance n.exc 500m where directed. (b) M&L for plastering 10mm thick in CM 1:3 using 100% coarse sand on roof surface including water proofing compound as per manufactures instructions and as directed by Engr-in-Charge. (c) Applying a coat of bituminous primer conforming to IS:3384-1986 @ 0.40 Ltrs/Sqm and allow to dry. (d) Applying and laying 3mm thick APP membrane having weight 3.2 – 3.5 Kg on prepared surface as per manufactures instructions and over laps 10cm and 15cm longitudinal and transverse directions respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into grooves on vertical plane and grove sealed with cement mortar 1 :3. (e) Applying two coats aluminium paint over membrane @ 0.20 Kg/Sqm complete all as specified and directed.
M&L preparation of roof treatment with APP polymeric water proofing membrane with roof tiles all as given below:- (a) Taking down existing water proofing treatment and cleaning roof surface by washing and rubbing etc and removing retrieved material to a distance n.exc 500m where directed. (b) M&L for plastering 10mm thick in CM 1:3 using 100% coarse sand on roof surface including water proofing compound as per manufactures instructions and as directed by Engr-in-Charge. (c) Applying a coat of bituminous primer conforming to IS:3384-1986 @ 0.40 Ltrs/Sqm and allow to dry. (d) Applying and laying 3mm thick APP membrane having weight 3.2 – 3.5 Kg on prepared surface as per manufactures instructions and over laps 10cm and 15cm longitudinal and transverse directions respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into grooves on vertical plane and grove sealed with cement mortar 1:3. (e) Screed bed 15mm thick in CM 1:4 as in beddding layers using 100% coarse sand. (g) M&L for 22mm thick roof tiles, set, jointed and pointed in neat cement slurry as in terraces over screed bed complete all as specified and directed.
M&L PCC 1:2:4 type B-0 (using 12.5 graded crushed stone aggregates) as in roof padding (approx avg 30 mm thick) etc complete all as specified and directed.
Dismantling of AC (corrugated/semi corrugated) sheet/PGI/CGI in roof covering including ridges, valley gutters complete all as specified and directed.
S&F 6mm thick Asbestos cement corrugated/semi corrugated sheet in roofs, fixed with L/J type hook or cranked hook bolt and making good to disturb surface etc complete all as specified and directed.
S&F AC Serrated ridge two pieces adjustable 6mm thick for corrugated or semi corrugated AC sheets fixed complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and making good to disturb surface, complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding/ridge/valley gutter in wall/roof, fixed with self tapping screws complete all as specified and directed.
Fixing only old or new roof covering of any type,size and thickness as in roof covering/cladding to wall, fixed with self tapping screws,hooks as requered on side complete all as specified and directed.
S&F 6 to 8mm thick poly carbonate sheet of any shape and size including in roof coverings including ridges etc complete all as specified and directed.
Repair of valley gutter joint filling with M-seal complete all as specified and directed.
S&F in repair PVC (SWR) pipes, single socketed in any length with rubber rings 110mm dia and fixed to wall complete all as specified and directed.
S&F in repairs PVC (SWR) bends any radius 110mm bore complete all as specified and directed.
S&F in repair PVC (SWR) junction single, (Single T) 110mm bore equal or unequal complete all as specified and directed.
S&F in repair PVC (SWR) pipes, single socketed in any length with rubber rings 75mm dia and fixed to wall complete all as specified and directed.
S&F in repairs PVC (SWR) bends any radius 75mm bore complete all as specified and directed.
S&F in repairs PVC (SWR) junction single, (Single T) 75mm bore equal or unequal complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed.(Fe- 410W Grade-E-250 quality A).
Dismantling wall and ceiling boards fiber, pulp, insulation etc any thickness including cover fillets etc complete all as specified and directed.
S&F in replacement ceiling 4mm thick Non asbestos fibre cement building boards only and including two coat of white wash, complete all as specified and directed.
S&F in replacement gypsum board 12mm thick in ceiling fixed with screw as per manufacturers instructions, complete all as specified and directed.(except grids)
S&F gypsum board 12mm thick in ceiling over and including anodised aluminium snap grid frame work for false ceiling, size of grid 605 x 605mm complete all as specified and directed.
M&L for preparation of ceiling surface and applying two coats of OBD over a coat of putty complete all as specified and directed.
S&F in replacement cement building board/designer E-Board only with all finishes size 595 x 595mm fixed in ceiling required complete all as specified and directed.
S&F grid false ceiling in GI system powder coated prelude main runner section 38 x 24 x 0.40mm, cross 'T' 28 x 24 x 0.40mm, wall angle 24 x 24 x 0.40mm and including providing and fixing 4mm thick non asbestos fibre fire resistant cement building board/designer E-Board with all finishes size 595 x 595mm fixed in ceiling frame work with all necessary hanging washers, expansion holding fasteners etc for securing framework to ceiling wherever required complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (including Cleaning repairing, etc) complete all as specified and directed.
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri
M/S R S Traders
M/S KESRI WORKERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .