Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC Award of Work as selected in transparent lottery | |
| 2 | L2₹23.3 LSame as L1Rejected-Finance AT GOUDAPANKAJSAHE PO DEHAGAON DIST NAYAGARH | NAYAGARH | NAYAGARH | ODISHA | L2 | Rejected-Finance Rejected in transparent lottery | |
| 3 | L2₹23.3 LSame as L1Rejected-Finance | L2 | Rejected-Finance Rejected in transparent lottery | |
| 4 | L2₹23.3 LSame as L1Rejected-Finance | L2 | Rejected-Finance Rejected in transparent lottery | |
| 5 | L2₹23.3 LSame as L1Rejected-Finance | L2 | Rejected-Finance Rejected in transparent lottery |
Tender Value
₹27.4 L
EMD Value
₹27,400
Closing Date
29 Dec 2025, 5:00 pmClosed
Executive Engineer, Brutang Irrigation Division
O/o EE,BID,Dasapalla
Construction of Main Entrance Gate Security Room and Boundary Wall for Administrative Building of Chief Construction Engineer Brutang and Hadua Irrigation Project at Dasapalla
2025_BIDVD_123203_1
Bid Identification No.EE-BID-BIP-07(01) of 2025-26, Dt.05.12.2025
Open Tender
Civil Works - Buildings
Percentage
120 days
Daspalla
Please refer Tender documents.
3 documents required · 3 mandatory
₹6,000
₹27,400
Yes
19 Feb 2026
15 Dec 2025
30 Dec 2025
15 Dec 2025
29 Dec 2025
15 Dec 2025
Cleaning and grubbing road land including uprooting rank vegtable, grass, bushes, shrubs, saplings and trees girth up to 300mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to be used or auctioned up to lead of 1000 mtr including removal and disposal of top organic soil not exceeding 150mm in thickness.
Dismantling Brick OR StoneDismantling Brick OR Stone Masonry of any thickness in Cement OR Lime Mortar under 3mt height ( alongwith plastering and cladding the tiles to walls ) including stacking the useful materials for reuse and removing / disposing the debris beyond the premises and cleaning the proposed work site including cost of all Labour, Sundries,T&P etc. complete in all respect as per approved drawings and as directed by the Engineer-in-charge . (No seperate payment will be made for execution of this item of work in any shape.)
Dismantling and removing R.C.C. columns including stacking the useful materials for reuse and removing the debris within 50m lead.
Earth work in excavation of foundation trenches in all kinds of soil including moorum stoney earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and leveling the bed upto the required depth and depositing the excavated materials away from the work site with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.
Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional antitermite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. as directed by the Engineer -in -charge.( The payment shall be made on the basis of the actual measurement of the plinth area of the building at Ground Floor and vertical faces will not be measured for payment)
Supplying & Filling foundation trenches , plinth & ditches with river sand well watered and rammed in layers not exceeding 23 c.m in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and taxes of all Materials, cost of all Labour,Sundries, T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge. (Measurement will be taken on finished compacted section only.)
Providing and Laying Plain Cement Concrete of proportion (1:3:6) in foundation and floors (i.e. below the base course of the flooring) using 40 mm size crusher broken H.G Stone Metal free from weathered skins , cement and screened & washed sharp river sand for mortar of approved quality & from approved quarry including hoisting, lowering and laying concrete to the required level, ramming, watering & curing etc complete to required levels, laid in layers not exceeeding 15cm thick in each layer including cost, conveyance , loading,unloading, stacking ,royalties and taxes of all materials, cost of all labour, Sundries, T&P required for the work including shoring, shuttering and dewatering ( if required) including hire and running charges of the water pump required for the work etc complete in all respect as directed by the Engineer-in-charge.
Providing Fly Ash Brick Masonry using Fly Ash bricks of size 25 c.m x 12 c.m x 8 c.m having crushing strength not less than 75 kg per square c.m. in cement mortar of mix (1:6) with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in the works in Foundation & Plinth and similar such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, royalties and taxes of all materials,cost of all labour,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.
Providing Fly Ash Brick Masonry using bricks of size 25 c.m. x 12 c.m. x 8 c.m. having crushing strength not less than 75 kg per square c.m. in cement mortar of mix (1:6) with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in the works in superstructure and similar such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.
Ground Floor
First Floor
Providing Fly Ash brick masonry using Fly Ash bricks of size 23 c.m. x 11 c.m. x 8 c.m.having crushing strength not less than 75 kg per square c.m in cement mortar of mix (1:4) (for half brick masonry wall) with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth, basement and for ornamental flower beds, plinth moulding and similar such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, royalties and taxes of all materials ,cost of all labour, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.
Ground Floor
Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 grade in Column Base, Column Footings, Stem of the Columns up to plinth level and Raft Foundation as per approved designs and drawings having a minimum compressive strength ( in work test) 250Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips( of required quantities) from weathered skins of approved quality & from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge.
Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 grade in PLINTH BAND / GRADE BEAM of approved designs and drawings having a minimum compressive strength ( in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by Engineer-in-charge.
Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 grade in all kinds Column in Superstructure as per approved designs and drawings having a minimum compressive strength ( in work test) 250Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips( of required quantities) from weathered skins of approved quality & from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centering and shuttering th
Ground Floor
First Floor
en after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge.
Ground Floor
Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 grade in all kinds LINTELS as per approved designs and drawings having a minimum compressive strength ( in work test) 250Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips( of required quantities) from weathered skins of approved quality & from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge.
Ground Floor
Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 grade in all kinds CHAJJA AND SILL PROJECTION (of 6.5cm. Average thick) as per approved designs and drawings having a minimum compressive strength ( in work test) 250Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips( of required quantities) from weathered skins of approved quality & from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge.
Ground Floor
First Floor
Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 grade in all kinds BEAM as per approved designs and drawings having a minimum compressive strength ( in work test) 250Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips( of required quantities) from weathered skins of approved quality & from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge.
Ground Floor
First Floor
Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 grade in all kinds ROOFSLAB as per approved designs and drawings having a minimum compressive strength ( in work test) 250Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips( of required quantities) from weathered skins of approved quality & from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge.
Ground Floor
First Floor
Cutting, Straightening coiled or bent up HYSD / TMT Reinforcement Bars of Fe 500 welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing Fan Hooks where necessary and hoisting, lowering and placing the same in proper position according to the approved designs and drawings in all floors at all height including cost, coveyance, loading, unloading ,stacking & taxes of HYSD/ TMT Reinforcement Bars and Binding Wires of 18 to 20 Gauge as required for the work , cost of all Labour ,Sundries, T&P,Staging and Scaffolding complete in all respect as directed by Engineer-in-charge. (Payment will be made according to the actual / proper weight of the HYSD / TMT Reinforcement Bars & Binding Wires consumed in the particular work only) .
Ground Floor
First Floor
16 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the rough surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc. required for the work complete etc. as directed by the Engineer- in -charge.
Ground Floor
First Floor
12 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the even surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding
Ground Floor
First Floor
of corners etc. required for the work complete etc. as directed by the Engineer- in -charge.
Ground Floor
6 m.m thick cement plaster in cement mortar of mix (1:4) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement to the ceiling of the Roof Slab, Staircase, Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jally and Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to all R.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking and taxes of all Materials, cost of all Labour,Sundries, T&P, Scaffolding,Watering, Curing etc. complete in all respect as directed by the Engineer- in- charge
Ground Floor
Providing, Fitting and Fixing minimum 8 m.m to 10 m.m thick double charge Vitrified Tile in flooring using vitrified Tile in flooring using vitrified Tile of approved quality, colour and size (600 mmx 600 mm coloured printed series homogeneous) in floors , treads on steps landings in all floors at all height on 25 m.m thick bed of cement mortar of mix(1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry joining the Vitrified Tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the Vitrified Tile if required (Tile are to be immersed in the water for required time before use) including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials , cost of all Labour , sundries, T&P required for the work, Watering, Curing for required days including cleaning the flooring space.
Ground Floor
First Floor
Providing, Fitting & Fixing of 8 mm. to 10mm. thick Vitrified Tile (of size 600mm.x600mm.) of approved make confirming to specifications having minimum breaking strength 1400 kg/sq.cm in dados skirting and riser of steps in all floors at all height on 12m.m thick cement mortar (1:4) to proper slope , line and level including cutting to required size and shape ,fixing at corners and splays etc. including filling the joints with silicon sealant to match the shade of Vitrified Tile as per the design & drawing including cost, conveyance, loading , unloading , stacking, royalties and taxes of all materials, cost of all labour, T&P , sundries , watering & curing etc. required for the work complete in all respect as directed by the Engineer-in-charge.
Ground Floor
Painting 2(two) or more coats with premium quality exterior emulsion paint(weather shield max ) of approved Brand/Quality & colour on the finished external plasterd surface using required quantities of paint by the concerned manufacturer to give an even shade over a coat of primer in all floors at all height, watering the surface before applying the Weather Coat paint and curing for the required period including cost , onveyance, loading , unloading , stacking, royalties and taxes of all materials, cost of all labour, T&P , sundries , watering & curing etc. required for the work complete in all respect as directed by the Engineer-in-charge.
Ground Floor
Finishing surface of interior walls with premium quality interior acrrylic emulsion paint over a coat of wall priming of approved make and finished smooth & even surface with two coats of wall putty to receive painting in all floors at all height including cost, coveyance, loading , unloading ,stacking and taxes of all Materials, cost of all Labour, Sundries ,Scafffolding ,Staging and T&P etc. required for the work complete in all respect as directed by the Engineer-in-charge.
Ground Floor
Supplying ,fitting and Fixing M.S Grills/ M.S shutter of approved Drawings & Designs made out of M S flat , square bars etc. of approved specifications/ dimensions with necessary welded clamps fixed in proper postion & plumb including a single coat of priming using approved quality metallic primer , making required holes in Massonary Walls /R.C.C. Structures including cost, conveyance, loading unloading , stacking , royaltites and taxes of all Materials, cost of all Labours , stacking,scaffolding, sundries, T&P etc.complete as directed by the Engineer-in charge.(Weight to be taken up properly to fixing the grills in the works and payment to be made accordingly)
Ground Floor
Providing, fitting, fixing UPVC windows( sliding type) including providing stainless steel hinges, locking arrangement and other requisite fittings and fixtures including cost, coveyance, loading, unloading and taxes of all materials,cost of all labour,scaffolding, staging, sundries and T&P required for the works etc. complete in all respect as per approved drawing,design & specification and as directed by the Engineer-in-charge all complete. (Fenest/ Wintek make)- Provisional Rate
Ground Floor
Painting with Synthetic enamel paint of approved colour, shade and brand like ICI/Asian/ Berger on stee work/ New wood work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation , loading, unloading, scaffolding, all labour ,sundries, T&P etc. complete as per the direction of the Engineer-in charge including filling gaps with putties , scrapping, sand papering, sand papering and cleaning the surface to make free from rusts, dust and only substances before applying primer etc. complete.
Ground Floor
Providing ,Supplying , fitting and fixing of openable UPVC doors with door frame and locking system of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. including cost, conveyance,loading, unloading and taxes of all materials , cost of all labour, scaffolding, staging, sundries and T&P required for works etc. complete in all respect as directed by the Engineer-in charge.
Filling in foundation trenches and plinth with excavated earth well waterd and rammed in layers not exceeding 23 c.m in depth including all lead and lift, cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge.
25 mm. thick Grading Concrete of proportion (1:2:2) on top of the Roof Slab using approved quality of cement, 6 mm. size hard crusher broken granite stone chips with screened & washed sharp sand for mortar of approved quality from approved quarry, washed & cleaned, free from all debrises and silt along with providing a layer of waterproofing treatment by using pedicrete (URP/SBR) Latex before grading concret (Mix - Latex @ 0.54 Ltr/Sqm & Cement @ 0.008Qntl /Sqm) including hoisting, lowering and laying concrete in all floors at all height after chipping, chiseling and cleaning the entire roof surface by using wire brush, finished smooth to proper required slope and gradient including cost, conveyance, royalties, loading, unloading,stacking and taxes of all Materials, cost of all Labour, T &P, Sundries, Watering ,Curing etc.required for the work complete in all respect as directed by the Engineer-in-charge.(sika/pidilite/equivalent)
Terrace
WALL PANELING WITH WOODEN SLAT HDF PLANK (FIRE RESISTANCE) Sypplying and installation of wall panelling of wooden slats (2440mm x128mm x16mm thick )surco high density fiberboard made out of pure pinewood particles ,FireResistance (Class -1) pinl in colour core with 5 test Fire Resistance BS 476 PART 5 BS 476 Part 6 BS 476 Part 7 iso 1182, ASTM E 662 Somke Density liminated finish perforated wooden grooved HDF slats 1162 (2mm grooves @8mm centers)tongue groove of lineal dimension size (2440mm x128 mm x16mm thick ) having density of 700 kg / m2, weight 9 kg / m2 with back fleers from sounders Germany nonwoven Acoustic to be pastrd on slat surco is to be installed by using GI strut system .The technical parameter are as follows Core Varients. Fiber board Climate (OCRH) -50 .70 Light reflectance .75% Geeen(RC % )-25 Hygiene (Voc Clean room )Low Class 1 Strength ,load capacity (kg)Anti sag ball Impact .
INTERNAL WIRING- (Modular)
Recessed wirring to light point/ fan point/ exhaust fan point/ cal
l bell point with 1.5 sq.mm FR PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia FR PVC conduit ISI marked Make-AKG / BEC / Precision / Norpak / Anchor / Kinjal 6A modular type switch ISI marked Make-Schneider (Zencelo) / Legrand( Myrius-NEXT GEN) / Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate Make-Schneider (Zencelo) / Legrand ( Myrius - NEXT GEN ) / Panasonic ( Vision ) of suitable size, modular box with 1.5 sq. Mm FR PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
Single light point controlled by one 6A switch or first light point or group control - Group-A .
Single light point controlled by one 6A switch or first light point or group control - Group-B .
Single light point controlled by one 6A switch or first light point or group control - Group-C .
Ceiling Fan point
Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge. (Make of wire - (Finolex /Anchor /Polycab / Havells / RR Kable / KEI)
Supply & fixing of 5 / 6 amp socket outlet on existing switch board with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge.Make-Schneider (Zencelo) / legrand( Myrius-NEXT GEN) / Panasonic (vision).(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supply, fixing with recessed wiring to 5 / 6 amp socket outlet on separate board 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. Make-Schneider (Zencelo) /Legrand (Myrius-NEXT GEN) / Panasonic (Vision).(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supply & fixing of 2 x 6 amp socket outlet controlled by 2 nos 6Amp on separate board, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. Make-Schneider (Zencelo) /Legrand (Myrius-NEXT GEN) / Panasonic (Vision).(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Excess running mtr for subsequent point of group control ) Make- Finolex / Anchor / Polycab / HAVELLS / RR KABLE / KEI in recessed HMS FR PVC conduit of mentioned size Make-AKG / BEC / Precision / Norpak / Anchor / Kinjal as required as per direction of Engg.-in-Charge.
Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (From BDB to Switch Board & 16A socket points ) Make- Finolex / Anchor / Polycab / HAVELLS / RR KABLE / KEI in recessed HMS FR PVC conduit of mentioned size Make-AKG / BEC / Precision / Norpak / Anchor / Kinjal as required as per direction of Engg.-in-Charge.
PANEL / DISTRIBUTION BOX
Distribution Board
Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted following sizes, SPN, MCB, DB siutable for, 240 V, Single phase 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below. (But without MCB/RCCB/ Isolator) Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9
12 Way SPN double door, MCB DB
Supply and fixing of 6 amp to 32 amp rating 240 V "C" series miniature circuit breaker suitable for inductive loads of the following poles in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required.(make- L&T / Legrand / Schneider or equvalant reputed make)
6Amp rating to 32Amp (SP) MCB
Supply and fixing of following rating double pole (single pole and neutral) 240 V residual current break (RCCB) having a sensitivity current up to 300 milli ampere in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required.(make- L&T / Legrand / Schneider or equvalant reputed make)
40Amp 2P RCCB (100mA/300mA) for BDB-P
CABLE
Supplying,laying of 3cx6 sq.mm copper flexible cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Polycab/ RR/ Finolex/ Havells/ KEI/ Gloster )
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.
3C x 6 sq.mm ( For BDB - Gate )
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.
Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of following sizes on LAYING OF CABLE ON SURFACE as required.
Upto 25 sq.mm
Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of following sizes on LAYING OF CABLE ON GROUND as required.
FITTINGS & FIXTURE
Supply of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting /Wall Fan/Ceiling Fans/Ex Fans of all sizes complete with all accessories and lamp etc as required.(Make-Philips/ Bajaj/ Havells/ Crompton)
Supply of 9 watt LED lamp of Philips EyePro B22 LED Bulb on existing angle/batten holder or equivalent
Supply of 10W LED Bulk Head fitting all connections of Philips catalouge No WT202W LED10S CW PSU S3 PC or equivalent
Supply of 15W LED Square surface fitting with all connections of Philips catalouge SM251/261 LED16S 6500 PSU WH or equivalent
Supply of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having
power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
Supply of LED Strip Outdoor type @5mtr with driver with all connections or equivalent
Supply of 1x7W LED "Garden Spike" fitting with all connections similar to Philips catalouge Model No. 31385 (Make- Philips/Havells/ Crompton/ Bajaj) or equivalent
Supply of 1x12W LED Wall washer "Alpha" fitting with all connections similar to Philips catalouge Model No. 58162 (Make- Philips/Havells/ Crompton/ Bajaj) or equivalent
Supply of.1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove / Havells Efficiencia Neo /Usha Technix) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge, Replacement Warranty will be 4 years.
Providing and fixing extra down rod of 20 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored
INSTALLATION OF FITTING FIXTURE
Supply and fixing circular/ HEXAGONAL G.I. box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick G.I. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the G.I. box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting of all sizes complete with all accessories and tube etc. directly on ceiling wall, including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.
Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.as per drawing and as per the direction of Engineer in charge
Installation, Testing and Commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor, earthing the regulator as required as per the direction of Engineer in charge
Supplying and fixing PVC batten/ angle holder including connections etc. as required, as per drawing and as per the direction of Engineer in charge
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
EARTHING
Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required.
Extra for using salt and charcoal for G.I or copper plate earth as required
Providing and fixing 25 mm x 5 mm Copper strip in 40 mm dia G.I. pipe from earth electrode as required.
Supplying and laying 25 mm x 5 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
stage.html
html • 0.08 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_571661.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.35 MB
Dtcn.pdf
Tender Documents • 15.03 MB
BOQ_571661.xls
BOQ • 0.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .