| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC 139 11 104 MUTTHIGANJ ALLAHABAD UTTAR PRADESH 211003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | L1 | Accepted-AOC Accepted being lowest quoted bidder | |
| 2 | L2₹35.5 L+₹7.1 L (25.0%)Rejected-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-AOC Rejected being other than lowest quoted bidder | |
| 3 | L3₹38.3 L+₹9.9 L (34.9%)Rejected-AOC 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | L3 | Rejected-AOC Rejected being other than lowest quoted bidder |
| Sl No | Description | Qty | Unit | P S TRADERS L2 | DK Builders L1 | Uma engineers L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for checking the leakage in both low and high side of the system by feeding dry nitrogen upto 300 PSI to maintain adequate pressure in the system, plugging the leaks including S&F in replacement of Teflon sealing of all refrigerant line valves like liquid lines valves/ suction/ discharge valves of compressors, gland packages of all angle valves flaring of all connections framing welding etc complete for AC plant of capacity 3x37.5TR-Plant for OT millitary Hospital, complete all as specified and directed . | 2 | Each Job | 3,000 ₹6,000 | 1,500 ₹3,000 Lowest | 2,000 ₹4,000 |
| 2.00 | All as per Srl item No. 1 above but for AC plant of capacity 2x75TR-Plant for Selection centre, complete all as specified and directed . | 1 | Each Job | 3,000 ₹3,000 | 2,000 ₹2,000 Lowest | 2,000 ₹2,000 Lowest |
| 3.00 | All as per Srl item No. 1 here-in-before but for AC plant of capacity 2x37.5TR-Plant for ERG of ABW Chheoki, complete all as specified and directed . | 1 | Each Job | 3,000 ₹3,000 | 3,000 ₹3,000 | 2,000 ₹2,000 Lowest |
| 4.00 | All as per Srl item No. 1 here-in-before but for AC plant of capacity 2x80TR-Plant for Cobra Auditorium, complete all as specified and directed . | 1 | Each Job | 3,000 ₹3,000 | 4,000 ₹4,000 | 2,000 ₹2,000 Lowest |
| 5.00 | M&L for opening the upper sheet and side sheet of AHU for access to cooling coil including for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing and changing of V Belt both set with necessary fitting and T&P for mounting for AC plant of capacity 3x37.5TR- Plant for OT Millitary Hospital , complete all as specified and directed . | 1 | Each Job | 3,000 ₹3,000 | 5,000 ₹5,000 | 1,500 ₹1,500 Lowest |
| 6.00 | All as per Srl item No. 5 above but for AC plant of capacity 2x75TR-Plant for Selection centre, complete all as specified and directed . | 1 | Each Job | 3,000 ₹3,000 | 5,000 ₹5,000 | 2,000 ₹2,000 Lowest |
| 7.00 | All as per Srl item No. 5 here-in-before but for AC plant of capacity 2x37.5TR-Plant for Erg of ABW Chheoki, complete all as specified and directed . | 1 | Each Job | 3,000 ₹3,000 | 6,000 ₹6,000 | 2,000 ₹2,000 Lowest |
| 8.00 | All as per Srl item No. 5 here-in-before but for AC plant of capacity 2x80 TR-Plant for Cobra Auditorium, complete all as specified and directed . | 1 | Each Job | 3,000 ₹3,000 Lowest | 6,000 ₹6,000 | 3,000 ₹3,000 Lowest |
| 9.00 | M&L for PCB Package AC plant of capacity 9 TR including in replacement of nut, bolt and other packing material etc; checking the proper electric connection, testing and commissioning for smooth operation at optimum efficiency for 803 FD Workshop, complete all as specified and directed . | 2 | Each Job | 12,000 ₹24,000 | 5,000 ₹10,000 Lowest | 10,000 ₹20,000 |
| 10.00 | Taking out the existing unserviceable the item of packege AC 9 TR capacity, including cooling coil ,air filters,plasma filters etc (indoor uint), condenser, condenser ,fan motor etc electrical/electonic circuits realays,wiring kit,thermostats, swiches, knobs,remote control unit, including PCB , fan blower and refixing the same in ex position complete after replacement with supply and fixing meterial as following item no 11 to 21 complete all as specified and directed .
Note:- Rate for taking down and refixing in original position shall be inclusived in rate quoted against item No. 11 to 21 and no extra amount shall be paid. | - | - | - | - | - |
Tender Value
₹43.9 L
EMD Value
₹87,840
Closing Date
19 May 2026, 6:00 pmClosed
HQ CWE PRAYAGRAJ
HQ CWE NEW CANTT PRAYAGRAJ
REPAIR, SERVICING, MAINTENANCE OF CENTRAL/PACKAGE TYPE AC PLANTS ETC ALONGWITH ASSOCIATED WORKS AT NEW CANTT PRAYAGRAJ/CHHEOKI CANTT UNDER GE (WEST) PRAYAGRAJ.
2026_MES_762486_1
82094/W/E8
Open Tender
Civil Works
Item Rate
180 days
Prayagraj
Class D and Category c(i)
6 documents required · 6 mandatory
₹500
GE (West) Prayagraj
₹87,840
Yes
1 Aug 2026
28 Apr 2026
26 May 2026
28 Apr 2026
19 May 2026
12 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for checking the leakage in both low and high side of the system by feeding dry nitrogen upto 300 PSI to maintain adequate pressure in the system, plugging the leaks including S&F in replacement of Teflon sealing of all refrigerant line valves like liquid lines valves/ suction/ discharge valves of compressors, gland packages of all angle valves flaring of all connections framing welding etc complete for AC plant of capacity 3x37.5TR-Plant for OT millitary Hospital, complete all as specified and directed . | 2 | Each Job | 1.25 | ₹2.5 |
| 2 | All as per Srl item No. 1 above but for AC plant of capacity 2x75TR-Plant for Selection centre, complete all as specified and directed . | 1 | Each Job | 2.25 | ₹2.25 |
| 3 | All as per Srl item No. 1 here-in-before but for AC plant of capacity 2x37.5TR-Plant for ERG of ABW Chheoki, complete all as specified and directed . | 1 | Each Job | 3.25 | ₹3.25 |
| 4 | All as per Srl item No. 1 here-in-before but for AC plant of capacity 2x80TR-Plant for Cobra Auditorium, complete all as specified and directed . | 1 | Each Job | 4.25 | ₹4.25 |
| 5 | M&L for opening the upper sheet and side sheet of AHU for access to cooling coil including for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing and changing of V Belt both set with necessary fitting and T&P for mounting for AC plant of capacity 3x37.5TR- Plant for OT Millitary Hospital , complete all as specified and directed . | 1 | Each Job | 5.25 | ₹5.25 |
| 6 | All as per Srl item No. 5 above but for AC plant of capacity 2x75TR-Plant for Selection centre, complete all as specified and directed . | 1 | Each Job | 6.25 | ₹6.25 |
| 7 | All as per Srl item No. 5 here-in-before but for AC plant of capacity 2x37.5TR-Plant for Erg of ABW Chheoki, complete all as specified and directed . | 1 | Each Job | 7.25 | ₹7.25 |
| 8 | All as per Srl item No. 5 here-in-before but for AC plant of capacity 2x80 TR-Plant for Cobra Auditorium, complete all as specified and directed . | 1 | Each Job | 8.25 | ₹8.25 |
| 9 | M&L for PCB Package AC plant of capacity 9 TR including in replacement of nut, bolt and other packing material etc; checking the proper electric connection, testing and commissioning for smooth operation at optimum efficiency for 803 FD Workshop, complete all as specified and directed . | 2 | Each Job | 9.25 | ₹18.5 |
| 10 | Taking out the existing unserviceable the item of packege AC 9 TR capacity, including cooling coil ,air filters,plasma filters etc (indoor uint), condenser, condenser ,fan motor etc electrical/electonic circuits realays,wiring kit,thermostats, swiches, knobs,remote control unit, including PCB , fan blower and refixing the same in ex position complete after replacement with supply and fixing meterial as following item no 11 to 21 complete all as specified and directed .
Note:- Rate for taking down and refixing in original position shall be inclusived in rate quoted against item No. 11 to 21 and no extra amount shall be paid. | - | - | 9.25 | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Specialcondition.pdf
Additional Documents • 0.49 MB
BOQ_854094.xls
BOQ • 1.54 MB
Tenderdocument.pdf
Tender Documents • 0.60 MB
Particularspecification.pdf
Additional Documents • 0.46 MB
Makes.pdf
Additional Documents • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .