| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.2 LAccepted-AOC AT C O MAHADEV RAY BANASO MANGARTILALA BANASO GIRIDIH JHARKHAND | BANASO | GIRIDIH | JHARKHAND | 825108 | L-1 | Accepted-AOC L-1 Bidder. |
Tender Value
₹3.0 L
EMD Value
₹3,800
Closing Date
15 Jul 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO (Civil), CHA
Office of AGM, CHA
Arrangement of raw water at Nandgaon filter plant under HLSA of Chandrapur Area.
2024_WCL_311608_1
WCL_CHA_civil_eT-031
Open Tender
Civil Works - Others
Item Rate
30 days
HLSA
As per NIT.
3 documents required · 3 mandatory
₹3,800
28 Jul 2024
1 Jul 2024
16 Jul 2024
1 Jul 2024
15 Jul 2024
1 Jul 2024
1 Jul 2024 - 8 Jul 2024
Amount
Supplying , erecting, testing and commissioning of minimum three & above star rated submersible pumpset of 5.625 KW/7.5 HP with 415 V, three phase, 50 Hz AC supply suitable for 150 mm dia. borewell with 110 to 510 LPM discharge at 107 to 30m head and discharge and delivery pipe of size 50mm dia with a necesary H type clamps as per specification no. WP-SMP
Supplying, erecting, testing and commissioning automatic control panel for three phase, 415 Submersible/centrifugal pump set upto 10 HP consisting of Star Delta starter having relay range 9-14 A, S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection with single phasing, phase reversal, phase imbalance etc.
Supplying , erecting, testing and commissioning of flat flexible 3 core 10 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with coloum pipe assembly complete
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing Ball plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200mm dia.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominalsize derived from natural sources).
Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.Sluice valves - PN -1 (Without by pass) 50mm.
Providing & erecting 3 Pole MCCB upto 415V, upto 100 A, rated short circuitbreaking capacity 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact MCCB with phase barriers on both sides, insulation withstand capacity 800 V , no line - load bias in provided enclosure/panel as per specification no. SW-MCCB .
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB/ TP MCB/ FP MCB/RCCB/ RCBO complete erected on provided angle iron GI frame.
Total impact of GST for the purpose of CTC
techsummary_322930.pdf
PDF • 4.13 MB
finsummary_322930.pdf
PDF • 4.13 MB
Award.pdf
PDF • 2.39 MB
finance_322930.pdf
PDF • 0.36 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .