Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.2 LAccepted-AOC | L-1 | Accepted-AOC Work allotted after financial approval from committee | |
| 2 | L-2₹25.2 L+₹6.1 L (31.7%)Rejected-AOC | L-2 | Rejected-AOC Work not allotted | |
| 3 | Rejected-Technical | - | Rejected-Technical All Condition Not Fulfill |
| Sl No | Description | Qty | Unit | VIJAY ELECTRICAL L2 | M/s RSPPL AGRA L1 |
|---|---|---|---|---|---|
| 1.00 | Cartage of New 11 KV CT-PT combined metering units from 132 KV Taj Store, Agra to Site of work with their loading and unloading at respective ends (Distance- 00-70 Kms) | 362 | Nos | 1,400 ₹5,06,800 | 826 ₹2,99,012 Lowest |
| 2.00 | Installation of New 11 KV CT PT combined metering units at outside double pole for HV-2 Consumers & other places as per requirement under EDC Agra including cost of 2 Nos. MS channel (125x55x6) of length 2240 mm, 1 No. MS channel (100x50x6) of length 2240 mm for supporting meter box, 2 Nos. MS angle 65x65x6mm of length 2280 mm, 4 Nos. PG clamps and required number of MS clamps with Nut & Bolts for holding the channel, angles etc. and other sundries items such as M.Seal, PVC tape etc. required for completion of work in all respect. The unit body shall be earthed by connecting MS strip 1/8"x1" connected to a earth rod of size 20mm x 2540mm. Both ends of the pole mounted units shall be insulated. MS Strip & earth rod provide by department and any other material, if required , shall be arranged by the Contractor at his own cost for proper completion the work. | 105 | Job | 6,000 ₹6,30,000 | 4,720 ₹4,95,600 Lowest |
| 3.00 | Dismantalling and Removal of existing damaged 11 KV CT-PT combined metering units by opening its 11 KV jumpers both incoming and outgoing, then installation of New 11 KV CT-PT combined metering unit and including the work of its both jumpers by using appropriate lugs, M.seal, PVC tape on bushings of CT-PT as per direction of Superivising Engineer. | 257 | Job | 4,000 ₹10,28,000 | 3,540 ₹9,09,780 Lowest |
| 4.00 | Cartage of damaged 11 KV CT-PT combined metering units from site of work to 132 KV Taj store Agra / Test Lab at Agra with their loading and unloading at respective ends. (Distance 00-70 Kms) | 257 | Nos | 1,400 ₹3,59,800 | 826 ₹2,12,282 Lowest |
Tender Value
₹24.6 L
EMD Value
₹25,000
Closing Date
27 Sept 2025, 1:00 pmClosed
SE
EDC, B 690, Kamla Nagar, Agra
WORK OF INSTALLATION NEW 11 KV CT-PT and REPLACEMENT OF OLD-DAMAGED 11 KV CT-PT COMBINED METERING UNITS UNDER AREA OF EDC, AGRA
2025_DVVNL_1070062_2
20/EDCA/2025-26
Open Tender
Electrical Works
Piece-work
90 days
EDC, B 690, Kamla Nagar
As per tender specification
2 documents required · 2 mandatory
₹3,540
www.dvvnl.org
₹25,000
14 Jan 2026
20 Sept 2025
27 Sept 2025
20 Sept 2025
27 Sept 2025
20 Sept 2025
Cartage of New 11 KV CT-PT combined metering units from 132 KV Taj Store, Agra to Site of work with their loading and unloading at respective ends (Distance- 00-70 Kms)
Installation of New 11 KV CT PT combined metering units at outside double pole for HV-2 Consumers & other places as per requirement under EDC Agra including cost of 2 Nos. MS channel (125x55x6) of length 2240 mm, 1 No. MS channel (100x50x6) of length 2240 mm for supporting meter box, 2 Nos. MS angle 65x65x6mm of length 2280 mm, 4 Nos. PG clamps and required number of MS clamps with Nut & Bolts for holding the channel, angles etc. and other sundries items such as M.Seal, PVC tape etc. required for completion of work in all respect. The unit body shall be earthed by connecting MS strip 1/8"x1" connected to a earth rod of size 20mm x 2540mm. Both ends of the pole mounted units shall be insulated. MS Strip & earth rod provide by department and any other material, if required , shall be arranged by the Contractor at his own cost for proper completion the work.
Dismantalling and Removal of existing damaged 11 KV CT-PT combined metering units by opening its 11 KV jumpers both incoming and outgoing, then installation of New 11 KV CT-PT combined metering unit and including the work of its both jumpers by using appropriate lugs, M.seal, PVC tape on bushings of CT-PT as per direction of Superivising Engineer.
Cartage of damaged 11 KV CT-PT combined metering units from site of work to 132 KV Taj store Agra / Test Lab at Agra with their loading and unloading at respective ends. (Distance 00-70 Kms)
VIJAY ELECTRICAL (BID ID -5566411)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .