Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAdmitted-Finance B 103 SAIRAJ REGENCY PIMPLE SAUDAGAR NEAR SAI CAMP AUNDH CAMP PUNE 411027 | PUNE | PUNE | MAHARASHTRA | 411027 | ₹38.4 L | L1 | Admitted-Finance |
| 2 | L2₹39.8 L+₹1.4 L (3.62%)Admitted-Finance | ₹39.8 L+₹1.4 L (3.62%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Work done certificate and Affidavit bond not uploaded |
| Sl No | Description | Qty | Unit | EVEREST ENTERPRISES L1 | Bhasruti Advanced Solutions and Engineering Pvt. Ltd. L2 |
|---|---|---|---|---|---|
| 1.00 | Providing & Fixing of Microprocessor based digital wireless level indicator water monitoring system with GSM based transmitter and receiver RTU having inbuilt software for data acquisition and system control at CWSS Waluj | 2 | Job | 6,75,000 ₹13,50,000 Lowest | 7,68,310 ₹15,36,620 |
| 2.00 | Supplying of full bore Electromagnetic flowmeter 600mm dia. At CWSS Waluj | 1 | Number | 14,19,730 ₹14,19,730 | 12,74,850 ₹12,74,850 Lowest |
| 3.00 | Arranging calibration of 600mm dia. electromagnetic flowmeter including volumetric testing of flowmeter at CWPRS Pune / NABL Acredated Lab including including payment towrds testing fees, transportation, loading/unloading , packing etc complete. | 1 | Number | 1,21,560 ₹1,21,560 Lowest | 1,22,580 ₹1,22,580 |
| 4.00 | Providing and supplying MS Flowmeter tail piece and connector suitable to various size of sluice valves,butterfly valve set with two flanged type welded to MS pipes made of MS plates of required thickness, bar stockmaterials with neoprene one piece V gland ring flangeddrilledasper IS1538 studs of electro-galvanized and joints paintedwith lightgrayenamel paint with necessary machining including hydraulic testing | 1 | Number | 1,14,940 ₹1,14,940 Lowest | 1,35,490 ₹1,35,490 |
| 5.00 | Supplying and erecting Double Shielded Signal cable for flowmeter | 100 | Running Meter | 2,200 ₹2,20,000 Lowest | 2,210 ₹2,21,000 |
| 6.00 | Suppling & installing of Panel board for indication of fluid flow and totalizer, the panel shall have suitable space to contain the devices safety.it shall have corrosion resistance and a provision for air cooling of electronics devices | 1 | Number | 21,850 ₹21,850 Lowest | 25,970 ₹25,970 |
| 7.00 | Supplying of Microprocessor base Digital DataMonitoring system with RTU (Remote Terminal Unit) | 1 | Number | 3,49,550 ₹3,49,550 Lowest | 3,69,120 ₹3,69,120 |
| 8.00 | Supervision, installation, erecting and commissioning of 600mm dia flowmeter at CWSS Waluj Indl. Area- unit charges including erecting, excavation, pipe fixing, jointing of tail piece, welding, clamping and necessary allied civil work with satisfactory trail. | 1 | Number | 1,20,350 ₹1,20,350 Lowest | 1,65,840 ₹1,65,840 |
| 9.00 | Providing Chamber for enclosing the sensor unit of flowmeter having suitable sizes by following standard civil construction procedure with using best quality bricks, cement and steel bars as per instruction of Engineer in- Charge | 2 | Number | 62,555 ₹1,25,110 Lowest | 65,450 ₹1,30,900 |
Tender Value
Refer Docs
EMD Value
₹38,500
Closing Date
27 Mar 2026, 11:00 amClosed
Superintending Engineer, MIDC Circle Office, CSN
Superintending Engineer, MIDC Circle Office, CSN
Upgradation of digital wireless level monitoring system and allied work at CWSS Waluj
2026_MIDC_1287533_1
32/A/03
Open Tender
Civil Works
Item Rate
CSN
Please refer Tender documents.
2 documents required · 2 mandatory
₹8,850
₹38,500
7 Apr 2026
16 Mar 2026
2 Apr 2026
16 Mar 2026
27 Mar 2026
20 Mar 2026
16 Mar 2026 - 18 Mar 2026
Providing & Fixing of Microprocessor based digital wireless level indicator water monitoring system with GSM based transmitter and receiver RTU having inbuilt software for data acquisition and system control at CWSS Waluj
Supplying of full bore Electromagnetic flowmeter 600mm dia. At CWSS Waluj
Arranging calibration of 600mm dia. electromagnetic flowmeter including volumetric testing of flowmeter at CWPRS Pune / NABL Acredated Lab including including payment towrds testing fees, transportation, loading/unloading , packing etc complete.
Providing and supplying MS Flowmeter tail piece and connector suitable to various size of sluice valves,butterfly valve set with two flanged type welded to MS pipes made of MS plates of required thickness, bar stockmaterials with neoprene one piece V gland ring flangeddrilledasper IS1538 studs of electro-galvanized and joints paintedwith lightgrayenamel paint with necessary machining including hydraulic testing
Supplying and erecting Double Shielded Signal cable for flowmeter
Suppling & installing of Panel board for indication of fluid flow and totalizer, the panel shall have suitable space to contain the devices safety.it shall have corrosion resistance and a provision for air cooling of electronics devices
Supplying of Microprocessor base Digital DataMonitoring system with RTU (Remote Terminal Unit)
Supervision, installation, erecting and commissioning of 600mm dia flowmeter at CWSS Waluj Indl. Area- unit charges including erecting, excavation, pipe fixing, jointing of tail piece, welding, clamping and necessary allied civil work with satisfactory trail.
Providing Chamber for enclosing the sensor unit of flowmeter having suitable sizes by following standard civil construction procedure with using best quality bricks, cement and steel bars as per instruction of Engineer in- Charge
stage.html
html • 0.03 MB
technical_2213903.pdf
techsummary_2213903.pdf
BOQ Comparative Chart
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_2213903.xls
BOQ • 0.28 MB
TenderDocument.pdf
Tender Documents • 0.32 MB
ItemSpecification.pdf
Other Document • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .