| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹38.7 L+₹9.2 L (31.0%)Rejected-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L2 | Rejected-AOC Bidder not quoted L1 rates | |
| 3 | L3₹40.9 L+₹11.3 L (38.3%)Rejected-AOC | L3 | Rejected-AOC Bidder not quoted L1 rates | |
| 4 | L4₹43.8 L+₹14.3 L (48.3%)Rejected-AOC 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | L4 | Rejected-AOC Bidder not quoted L1 rates | |
| 5 | L5₹46.4 L+₹16.8 L (57.0%)Rejected-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L5 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
8 Aug 2022, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GENERAL BHAGAT MARG PUNE 411040
8356 MAINT/REPL/REP TO LT PROTECTIVE SYST, PANEL, UG CABLE, MCCB, CHANGE OVER, LIGHTING, APFC PANEL EARTHING AND THEIR CONNECTED MISC WK IN THE AREA OF AICTS HOSP AREA, FMLY QTRS, OFFRS QTRS AND OTHER TECH ACCN AND OTHER CONNECTED AREA UNDER GE S PUN
2022_MES_537549_1
8356 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹88,000
4 Oct 2022
12 Jul 2022
10 Aug 2022
12 Jul 2022
8 Aug 2022
26 Jul 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out cable etc and repairs / laying cables etc and getting out in following type of strata complete all as specified and as directed by the Engineer-in-Charge.
Soft/Loose soil
Hard Dense soil
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete, complete all as specified and directed.
M & L for plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in base of pole or in any situation all as specified and directed
M & L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping including necessary form work or in any situation all as specified and directed
M&L for laying of Reinforced concrete pipes,class NP2 of dia 100 mm ,2 nos half round ( for bottom and top )and before laying exacaved area shall be leveling all as specified and directed Engr-in-charge.
M&L for straight through joint kit heat shrinkable suitable for the following size LT under ground cable 1100 volt grade armoured with aluminium conductor including necessary lugs and earth work etc all as specified and as directed. [Make - M-Seal / Danson/Raychem/ 3M] (Note : Taking out / Relaying of old cable cover/Bricks deemed to be included in the rates. )
LT cable 3.5 core 25-50 sqmm
LT cable 3.5 core 70- 120 sqmm
LT cable 3.5 core150- 240 sqmm
M&L for repairs to LT panel boards complete with wiring of suitable size / existing size copper cable with necessary works complete all as specified and as directed by Engineer-in-Charge
M&L for repairs to LT panel boards complete with necessary welding works to doors, replacement of unserviceable hinges and aldrop bolts complete all as specified and as directed.
M&L for prepration of old painted surface of LT panel board /Bus Bar boxes etc and applying one coat of synthetic enamel paint as specified for panels complete all as specified and as directed by Engineer-in-Charge
M & L for replacement of damaged sheet of panel board of thickness 2 mm to match to existing sheet including bending, cutting, pressing to required size and shape including painting with two coats of synthetic enamel paint over a coat of primer to match the existing surface complete all as directed.
Supply and fix in repairs danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with screws on LT panel boards of size 20x15 cm complete all as specified and as directed
M&L for pin point of fault in LT/HTunderground cables by using high voltage fault detector machine as and when required at site complete all as per the direction of Engineer-in-Charge
M&L for disconnecting burnt LT cable from MCCB/Main switch/Transformer etc and cleaning the bus bar and removing carbon and rusted nut bolts etc complete and reconnecting the LT cable after replacement of aluminium lugs, glands and insulating exposed inner core of the cable with insulation tape etc for the following size cables per the direction of Engineer-in-Charge
LT under ground cable 10 to 25 sqmm 4 core
LT under ground cables 50 to 95 sqmm 3.5 core
LT under ground cable 120 to 185 sqmm 3.5 core
Taking down Old unserviceable Cable of any size and make complete all as specified and directed
Supply, Laying, joint, test and commission LT under ground cable 1100 Volt grade, XLPE insulated, armoured and sheathed with Aluminium conductor of following sizes including cable glands, lugs, jointing materials etc laid in trenches / floors / ducts all as specified and directed. (Note: Earth work and excavation shall be measured and paid separately.)
240 Sqmm 3.5 core
185 Sqmm 3.5 core
150 Sqmm 3.5 core
95 Sqmm 3.5 core
70 Sqmm 3.5 core
50 Sqmm 3.5 core
35 Sqmm 3.5 core
25 Sqmm 3.5 core
16 Sqmm 4 core
10 Sqmm 4 core
6 sqmm 4 core
Taking down old unsv LT panel and Supply,installing, testing and commissioning of free standing weather proof, dust and vermin proof LT cubicle/ Modular construction fully compartmentalized panel out door type,with bus bar chamber and cable ally, IP-54 and all as per IE rules fabricated with 3.0 mm CRCA double door type (Front side ; out side with main panel door and inside with compartmentlised door for each cubicle, Rear side main panel door ) Sheet for load bearing members and 2 mm thick for doors and covers and shall be powder coated with 7-tank process on all internal and external surfaces. the panel to be suitable for 1100 volt grade, 3 phase, 415 volts, 50 cycles AC supply. The panel shall be provided with MS angle iron frame 50x 50x 6 mm welded in shape and including necessary grouting in pcc 1:3:6 type C-1 with 20 mm grade stone aggregate completed with legs 30 cm in ground in pcc and 40 cm above ground including connecting to cable with cable gland, lugs etc”and comprising the following :
Supply,installing, testing and commissioning of free standing weather proof, dust and vermin proof LT cubicle/ Modular construction fully compartmentalized panel out door type,with bus bar chamber and cable ally on both side, IP-54 and all as per IE rules fabricated with 3.0 mm CRCA double door type (Front side ; out side with main panel door and inside with compartmentlised door for each cubicle, Rear side main panel door ) Sheet for load bearing members and 2 mm thick for doors and covers and shall be powder coated with 7-tank process on all internal and external surfaces. the panel to be suitable for 1100 volt grade, 3 phase, 415 volts, 50 cycles AC supply. The panel shall be provided with MS angle iron frame 50x 50x 6 mm welded in shape and including necessary grouting in pcc 1:3:6 type C-1 with 20 mm grade stone aggregate completed with legs 30 cm in ground in pcc and 40 cm above ground including connecting to cable with cable gland, lugs etc”and comprising the following :
Design, supply,install, test and comissioning of vermin proof Automatic power factor control panel 50 KVAR indoor installation factory made fabricated with 2.0 mm thick CRCA sheet for load bearing members and 1.6 mm thick for doors and covers and shall be painted with epoxy powder paint by means of electro static gun after rigorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 200 Amps rating TPN bus bars of high conductivity aluminium alloy and shall be provided with colour coded heat shrinkable sleeves,with more depth for accommodating Capacitor bank 08 Nos inside of the panel.
ITEM No. 20.00 Contd... The panel shall be modular/cubical trype with bus chamber cable allyand provided with separate fully compartments for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged door , front and rear openable with locking arrangement and suitable for 1100 Volts grade , 3 phase 415 Volts , 50 cycles , AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54 . The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm , embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate , 500 mm above ground level and comprising the following including taking out of old panels etc , removing of cables and connecting to new panels with all required material such as glands, lugs etc
Supplying and laying GI pipe, 50mm dia, Light grade for cable protection at road crossing etc including necessary road cutting and making good with PCC 1:2:4, Type B-1, using 20mm graded stone aggregate, 100mm thick or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed by the Engineer - in - Charge.
Supplying and laying GI pipe, 80 mm dia, Light grade for cable protection at road crossing etc including necessary road cutting and making good with PCC 1:2:4, Type B-1, using 20mm graded stone aggregate, 100mm thick or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed by the Engineer - in - Charge.
Supplying and laying GI pipe, 100 mm dia, light grade for cable protection at road crossing etc including necessary road cutting and making good with PCC 1:2:4, Type B-1, using 20mm graded stone aggregate, 100mm thick or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed by the Engineer - in - Charge.
Supply and fix in repairs digital Voltmeter 0-500 volt square type complete with necessary fixing complete all as specified and as directed.
Supply and fix in repairs digital ammeter 0-100 amps square type complete with necessary fixing and 3 Nos of CTs complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs digital ammeter 0-200 amps square type complete with necessary fixing and 3 Nos of CTs all as specified and as directed.
Material and labour for painting of steel tubular pole 9mtr height including cross arm, clamp, back plate etc in situ on with one under coat and one finishing coat with aluminium paint after cleaning preparation of surface including making alternate yellow and black strip 30 cm wide 5 nos. with two coats of synthetic enamel paint complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to GI earth strip 25x4 mm connected to the plate by means of GI bolts & nuts complete all as per Electrical plate No. 5 of SSR Part - I, connected to earthing test point including testing on completion including main earthing, charcoal, common salt, PCC 1:3:6, Type C-2 earth pit with RCC cover, MS funnel with GI watering pipe, wiremesh, earth work excavation etc complete all as specified and as directed by the Engineer - in - Charge. (Note - GI earth strip and protection pipe will be measured and paid seperately beyond 7.50 mtr)
M&L for repair of existing earthing pit chamber as under : (a) Repair to damaged plaster in cement mortar 1:6, 10mm thick to match with existing. (b) Provision of RCC (1:2:4, type B1 using 20mm graded stone aggregates) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) with lugs 2 Nos and with 6 mm dia MS bar handle made to shape (c) Provision of funnel and wire mesh. (d) Two coats of White wash on surface of earthing chamber.
M&L for earth continuity conductor or main earthing lead fixed to wall on batter or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25 x 4 mm dia galvanised iron strip, complete all as specified and directed.
M&L for cleaning of 2/4 pole structure/ sub station /OHR/UG sumps/Pump house surrounding by surface dressing including removing shrubs, grass, mini plants and other unwanted materials and levelling and removing the excavated materials not exe. 50 mtr complete all as specified and as directed.
M&L For Cutting/trimming of tree branches up to 80mm dia along overhead Electric lines which are growing/touching or falling on ACSR conductor /poles or near by substn etc., at any height upto 11 mtr from ground level and making sufficient clearence(1.5mtr) from ACSR conductor /poles /structure and taking down the same on the ground carefully &take all safety precaution to avoiding the damage and removing to a distance where directed by Engr-In-Charge
M&L for Attending fault of APFC pannel including repair to APFC pannel, replacing burned out wiring, setting and adjusting APFC relay etc complete and making APFC pannel servicable all as specified and directed (NOTE : Cost of wiring / materials are included in quoted rates)
Supply and fix in repairs APFC relay 12 stage for automatic correction of power factor suitable for 415 volt 3 phase power supply complete with necessary fixing conforming to cat part No. L&T Cat No. ERPML08D500 or equivallent in Siemens/Schneider/ Legrand
Supply and fix in repairs Capacitor of 2 KVAR Capacity complete all as specified and as directed.
Supply and fix in repairs Capacitor of 3 KVAR Capacity complete all as specified and as directed.
Supply and fix in repairs Capacitor of 5 KVAR Capacity complete all as specified and as directed.
Supply and fix in repairs Capacitor of 10 KVAR Capacity complete all as specified and as directed.
Supply and fix in repairs Capacitor Duty Contactors suitable for 5 KVAR capacitor complete (L&T Type MO C25 or same type in Siemens/Schneider/ Legrand)
Supply and fix in repairs Capacitor Duty Contactors suitable for 10 KVAR capacitor complete all as specified and as directed.
M&L for taking out old unserviceable Change over switch and supply and fix new auto transfer switch ATS] with automatic/Manual control with inbuilt time delay etc complete with enclosure 200 amp 4 pole including necessary arrangements to fix the ATS on wall with necessary bus bar and cable end boxes to connect incoming cable and out going cables complete all as specified and as directed. (Make- L&T(DV/D-sine) /Siemens (3 VA ) /Schneider (CVS) / Legrand (DX3)/C&S/Havells)
M&L for taking out old unserviceable Change over switch and supply and fix new auto transfer switch[ATS] with automatic/Manual control with inbuilt time delay etc complete with enclosure 125 amp 4 pole including necessary arrangements to fix the ATS on wall with necessary bus bar and cable end boxes to connect incoming cable and out going cables complete [Make- L&T(DV/D-sine) /Siemens (3 VA ) /Schneider (CVS) / Legrand (DX3)/C&S/ Havells
M&L in replacement for heat shrinkable end termination jointing kit for HT 22 KV XLPE cables up to 120 Sqmm 3 core including all accessories required complete all as specified and as directed. [Make :- Denson/M Seal/3M.]
M&L in replacement for heat shrinkable Straight through jointing kit for HT 22 KV XLPE cables up to 120 Sqmm 3 core including all accessories required complete all as specified and as directed. [Make :- Denson/M Seal/3M.]
Supply and fix Multifunction Meter-( Make -L&T( MFM 4410 LED meter Cl 0.2S with RS485 ) equivalent in SIEMENS / Schneider )with required wiring and CT including taking down any type of meter all as specifed and directed
Supply and replace indicator LED lamp any colour complete all as specified
M & L for Attending the fault in UPS -10/15/20 KVA of any Make and Servicing of the UPS including setting the UPS for proper function, replacing minor spare parts and repairing and blowing out dust from inside the UPS complete all as specified and directed. (Note : Spare parts required shall be inclusive in quoted rates)
Supply and fix on wall / ceiling multi core flexible copper conductor pvc insulated and sheathed cable 4 Core 25 Sqmm, 1100 volt conforming to IS:694 including taking down existing aluminium cable connecting to UPS/MCCB/DB and other equipment with lugs, glands and necessary jointing material all as specified and directed.
Supply and fix on wall / ceiling multi core flexible copper conductor pvc insulated and sheathed cable 4 Core 10 Sqmm, 1100 volt conforming to IS:694 including taking down existing aluminium cable connecting to UPS/MCCB/DB and other equipment with lugs, glands and necessary jointing material all as specified and directed.
Supply and replace on load change over switch disconnector in Sheet metal enclosure 200 Amps 415 Volt 4 Pole all as specified and directed.
Taking down broken/damaged RCC pole and supply and fix Steel tubular swaged poles complete with cast iron base plate, finial tape plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) complete all as specified and directed by the engineer in charge.
S&F in replacement MCCB 4 pole 125 Amp, Icu = 18 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections complete including MS enclosure of suitable size all as specified and directed. (Make : L&T (DBVTL004DD ) or Equivalent in Legrand/ Schneider /C&S)
S&F in replacement MCCB 4 pole 200 Amp, Icu = 18 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections complete including MS enclosure of suitable size all as specified and directed. (Make :- L&T (DBVTL004DD ) or Equivalent in Legrand/ Schneider /C&S)
S&F in replacement MCB SP 6-32 Amps,10KA,'C' series complete all as specified and as directed.
S&F in replacement MCB SPN 20-40 Amps,10KA, 240V,'C' series complete all as specified and as directed.
S&F in replacement MCB TP 32/40 Amps ,10KA,415 V,'C' series complete all as specified and as directed.
M&L for taking out old unserviceable MCB/MCCB TP/TPN from existing LT panel board and supply and fix MCCB FP 63 amps capacity ,Adjustable Thermal Magnetic, rup capacity 16 KA at 415 volt 50 Hz AC supply including necessary modification in panel board if required to fix the MCCB complete with replacement of brunt lugs and wire/cable pieces etc as required at site [Make- L&T(d sine) /Siemens (3 VA ) /Schneider (CVS ) /Legrand ( DX3 )/C&S ]
All as per Item No 57.00 above but 100 amps capacity FP, rup capacity 16 KA complete all as specified and as directed.
All as per Item No 57.00 above but 200 amps capacity FP rup capacity 35 KA complete all as specified and as directed by Engineer -in-Charge
All as per Item No 57.00 above but 400 amps capacity FP rup cap 35 KA at 415 volt complete all as specified and as directed by Engineer -in-Charge
All as per Item No 57.00 above but 125 amps capacity FP, rup capacity 35 KA complete all as specified and as directed by Engineer -in-Charge
All as per Item No 57.00 above but 250 amps capacity FP rup capacity 35 Ka complete all as specified and as directed by Engineer -in-Charge
All as per Item No 57.00 above but 160 amps capacity FP rup capacity 35 Ka complete all as specified and as directed by Engineer -in-Charge
M&L for taking out unserviceable contactor ML-3 TP from panel board and supply and fix power contactor ML-3 TP 40 amps capacity suitable for operation on 415 volt 50 Hz AC supply complete all as specified and as directed
M&L for taking out unserviceable contactor ML-4 TP from panel board and supply and fix power contactor ML-4 TP 70 amps capacity suitable for operation on 415 volt 50 Hz AC supply complete all as specified and as directed.
Taking down Unserviceable flood light from 15 mtr high mast pole through mechanically or manually after repair/replacement of flood light should be refix on same place complete all as specified & directed by Engr-in-charge. (Note :- All T&P i.e ladder, tools, safety gloves etc will be provided by the contractor without any extra cost.)
Supply & Fixing in replacement of 150 watts LED flood light for high mast light highly efficient LED lood light with lens made of pressure die cast aliminium housing, extruded aluminium heat sinks & enclosed with toughened glass IP-66 fitted on the wall/ roof top/pole etc. with the help of nuts,bolts, clamps PCC work, complete all as specified and as directed.
Supply & Fixing in replacement of 100 watts LED flood light for high mast light highly efficient LED flood light with lens made of pressure die cast aluminium housing, extruded aluminium heat sinks & enclosed with toughened glass IP-66 fitted on the wall/ roof top/pole etc. with the help of nuts,bolts, clamps PCC work, complete all as specified and as directed.
S&F in replacement mild steel work (structural) as in cross arm bracing supports, clamps & back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending, drilling holes for bolts in any size or shape as indicated including one primer coat with red oxide primer & one black finishing coat of aluminium paint complete all as specified and directed.
S & F in repair framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for Synthetic Insulating Mat for Electrical Instrument of size 2mx1mx12mm, complete all as specified and directed.
Rama Electricals
CHAITANYA WINDWELL
RELIABLE ENTERPRISES
metro electrical services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .