Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC | ₹28.7 L | L1 | Accepted-AOC Lowest tenderer |
| 2 | L2₹30.6 L+₹2.0 L (6.95%)Rejected-Finance | ₹30.6 L+₹2.0 L (6.95%) | L2 | Rejected-Finance Other than lowest tenderer |
| 3 | L3₹30.8 L+₹2.2 L (7.55%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹30.8 L+₹2.2 L (7.55%) | L3 | Rejected-Finance Other than lowest tenderer |
| 4 | L4₹31.7 L+₹3.0 L (10.6%)Rejected-Finance | ₹31.7 L+₹3.0 L (10.6%) | L4 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
23 Jan 2021, 6:00 pmClosed
GE NAGROTA
GE NAGROTA C/O 56 APO
SPECIAL REPAIR TO OVERHEAD LINE TO UNDERGROUND CABLE, PANEL AND OTHER CONNECTED SERVICES AT STN HQ, PROVN OF SECURITY LIGHTS FROM STP TO POST NO. 11 THROUGH KOTE AND HQ 19 INF DIV OTM ACCN AND CERTAIN REVENUE AND MINOR WORKS UNDER GE NAGROTA.
2020_MES_406904_1
GEN-65/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
NAGROTA
Class D and above and category b (I)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹60,000
Yes
9 Feb 2021
24 Dec 2020
28 Jan 2021
24 Dec 2020
23 Jan 2021
8 Jan 2021
Amount
Supply and install high wall 1.5 TR split AC units indoor/outdoor complete with cordless remote control unit and with cooling and heating function of capacity as shown with copper tubing condensor including all necessary fixing arrangement and accessories including mounting bracket for outdoor unit complete all as specified and directed.
S&L for votage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of +/- 2.5% for the capacity 5 KVA complete all as specified and directed.
S&F of sheet metal enclosure single pole and netural with a two pin and earth metal plug and socket with one single pole MCB 240 volts 20 Amps complete all as specified and directed.
S & F MCB single pole 6 to 32 Amps, 230 volts 'C' curve, 50Hz AC 10KA, complete all as specified and directed.
S&F insulation for copper tubes of split type AC units , insulation tupe superion of size 3/8" dia complete all as specified and directed
S&F insulation for copper tubes of split type AC units , insulation tupe superion of size 5/8" dia complete all as specified and directed
S&F copper tubing soft grade suitable for split type AC suction/discharge line of size 5/8" dia complete all as specified and directed
S&F copper tubing soft grade suitable for split type AC suction/discharge line of size 3/8" dia complete all as specified and directed
S&F submain wiring with 2 runs of 4 sqmm , PVC insulated , unsheated, single core, multi stranded, 1100 volts, copper conductor cable drawn in and inclding 25/32 wide PVC casing and caping with all accessories such as tees, elbows, junction box, reducers etc as requred along with 1 run of 2.5 Sqmm PVC insulated usheated single core multi stranded copper conductor cable as continous earth wire and connecting to existing main switch board/distrubution board and testing on completion including taking down old submain wiring of any type with conduct complete all as specified and directed by Engr-in-Charge. Note: 2 Runs of 4 Sqmm cable, 1 run of 2.5 Sqmm PVC insulated unsheated single core multi stranded copper conductor cable and 1 run of PVC casing/caping 25mm/32mm wide shall be measured as single run.
S&F ceiling fan 1200 mm sweep single phase AC 230/240V complete incl grouting of eyebolt of suitable size in ceiling and fixing the fan by mean of suitable bolt, nuts, washers and provision of flexible copper conductor cable 3 core 23/0.0076 size from ceiling rose to fan complete all as specified and directed.
S&F step type fan regulator 300 watt, 230 volts, 50 Hz AC complete all as specified and directed.
S&F high wall indoor/outdoor complete with cordless remote control unit and with cooling and heating function of capacity 1.5 TR AC and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity as shown with copper tubing condensor including all necessary fixing arrangement and accessories including mounting bracket for outdoor complete all as specified and directed
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for electric poles stay foundation, and under ground electric power cables and getting out etc. complete all as specified and directed.
All as per ser item No. 13 here in above but exceeding 1.5 m depth and n exc 3 m in depth
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete in any type of soil,complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50m from the starting point, complete all as specified and directed.
Sand dry clean as cushioning to underground electric cable provided all as specified in clause 19.75 of of SSR Part-I 2009 complete all as specified.
Supply and fixing in replacement of 60 W LED Street Light luminaire confirming including all necessary arrangement for fixing on Pole made up of Epoxy coated pressure Die Cast aluminum housing confirming IP66 for Optical Compartment and Control Gear Compartment. The Optical compartment shall be covered with heat resistant toughened glass for safety. LED Street Light should be provided with non -yellowing modular secondary lens optics .The driver used is specially designed to have built-in-surge voltage,open/short ckt protections .Built in surge protection of 4 kv and External surge protection of 10 kv provided for additional safety.side entry mounted for 40 mm and above OD pipe bracket. The LED shall be tested with LM80-08 standard .The LEDs used in Street Light shall have CCT of ≥ 5700 K with CRI of ≥70. The LED Street Light shall be of Integral type. The Input voltage range shall be 140V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have luminous of ≥ 90/watt and power factor more than 0.9 with THD less than 10% complete as specified and as directed.
M&L in repairs for three run single core zero halogen flame retardant insulated cable 2.5 Sqmm with unilay copper conductor and drawn through pole from junction box to street light throuh conduit pipe properly fixed with pole through clamps ,nut bolts etc , complete all as specified and directed by Engr-in-Charge.
S & F 40 mm bore Steel tubing galvanized(Light grade) conforming to IS -1239 for passing cable under road /floor or fixing to poles for protection of underground cable complete with flat iron 50x6 mm clamps made to shape and 12mm dia bolts, nuts and washers for fixing where required, complete all as specified and directed. (NOTE:- Excavation and earth work shall be measured and paid separatly)
S & F mounting arm for installation of LED light made from (40 mm bore dia) GI pipe medium grade of total length 1.5 mtrs fabricated as per approved design, supplied alongwith mounting clamps-02 Nos, fabricated from 65mm x 5 mm MS sheet, complete all as specified and directed.
Terminal boxes made out of 2 mm thick sheet metal of size 300mmx250mmx200mm with front opening fitted with aluminium bus bar four strip of size 200x25x6 mm on porcelain insulators with complete fitted with clamps made out of flat iron 25x3 mm with nuts and bolts fixed to street/RCC pole including taking down defective cable terminal boxes, complete all as specifed and directed.
S&F of automatic change over switch with rating of 100 Amps 230 volt 50Hz 4 pole 3 phase complete with all fitting and fixture complete all as specified and directed by Engr-in-Charge.
Brick proection using sub class 'B' well burnt clay bricks of size 230 mm x 115 mm x 75 mm as a machnical protection to the power electric cable laid dry flat in the cable rench across the length of the cable complete all as specified and directed
Supply and laying testing and commissioning in trenches, ducts or fixing to pole/wall or passing through XLPE insulated armoured , heavy duty electric cables with aluminium conductor 1100 V grade cross sectional area 10 Sqmm, 2 core complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 95 Sqmm 3.5 core including taking down old cable, complete all as specified and directed by Engineer-in-Charge. (NOTE:- Excavation and earth work shall be measured and paid separatly)
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 35 Sqmm 3.5 core cable, complete all as specified and directed by Engineer-in-Charge. (NOTE:- Excavation and earth work shall be measured and paid separatly)
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 16 Sqmm 2 core cable, complete all as specified and directed by Engineer-in-Charge. (NOTE:- Excavation and earth work shall be measured and paid separatly)
Supply, installation, commissioning and testing of CPRI approved outdoor cubical type LT feeder piller box suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system fabricated from stainless steel totally enclosed dust , weather & vermin proof 3mm thick for outer shell and 2 mm thick CRCA sheet for inner shell having MS section not less than 50 mm x 50 mm x 6mm thick having TPN aluminium bus bar of 200 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement with MCCB FP 100 Amp, 16 KA, 415 Volts 50 Hz with adjustment thermal and adjustable magnetic setting and provn for incoming and outgoing cables with glands including control wiring with minimum 1.5 Sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.
Supply in replacement chage over switch off load type with enclosure conforming IS 13947 part I & III 415 V, 4 pole of rating 100 Amps complete all as specified and directed.
S&F of CPRI approved outdoor cubical type wall mounted bus bar of capacity 200 Amp TPN duly fixed on wall with nut bolts wahers complete all as specified and directed.
Supply and fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of nature light having ON ≤ 30 lux and OFF ≥ 10 Lux . The sensor (Nature Switch) along with suitable power contactor , MCB and support termianl should be enclosure made of rust proof, electric shock proof , termite proof and FR grade SMC junction box(sintex make) conforming to confirmining IS 13947.4-1 & IS 8828, IP 66 including contactors ( 3 Nos each) and incoming- ourgoing MCBs ( 3 Nos each) rating of 25-40 amp and Circuit copper wiring of min 10 Sqmm cable, complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 3 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20 mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 3 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
Supply and fixing automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of nature light . The sensor (Nature Switch) along with suitable power contactor , MCB and support termianl should be enclosure made of rust proof, electric shock proof , termite proof and FR grade SMC junction box(sintex make) conforming to confirmining, IP 54 including contactors ( 3 Nos each) and incoming- outgoing MCBs ( 3 Nos each) rating of 20-25 amp and Circuit copper wiring of min 10 Sqmm cable, complete all as specified and directed.
S&F steel tublar swaged poles complete with cast iron base plate, final tapper, plug, bolt nuts & screws as specified tupe 410 SP 22 (9 mtr long) complete all as specified and directed
Supply laying jointing and testing XLPE insulated PVC sheathed armoured under gorund cable heavy duty with alumimium conductor LT 1100 V grade cross sectional area 10 Sqmm 4 core complete all as specified and directed. Note:-Excavation and Earth work will be measured and paid separately.
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 70 Sqmm 3.5 core , complete all as specified and directed by Engineer-in-Charge. Note:-Excavation,returning and removing will be measured and paid separately.
All as per ser item No 39.00 here in before but 50 Sqmm 3.5 core.
All as per ser item No 39.00 here in before but 25 Sqmm 4 core.
All as per ser item No 39.00 here in before but 16 Sqmm 4 core.
Supply and fix new generation energy saving and environmental friendly long life led street light fitting 90 W, made up pressure die cast aluminium housing with high powder LED as lightning source and lens embedded PC Cover having TOP opening separate driver compartment with IP 66 protection and impact resistance of IK 07 with 10 KV built in surge protection. suitable for Side entry, pole mounting with brackt arm OD 54 mm pipe bracket. The LED shall be tested with LM79 standard. The LEDs used in street light shall have CCTof > 5700 K with CRI of > 70. The LED street light shall be of integral type. The Input Voltage range shall be 140V to 270 V and operating Temp -10 C +50 C, average life 50000 hrs . The LED driver shall be of isolated type with constant current voltage topology to ensure optimum driving of LEDs, The LED street light shall have luminous of > 90/Watt and power factor more than 0.9 with THD less than 10% Complete all as directed by Engr-in- charge.
S&F Mounting arm for installation of LED light made from 1.5"(40mm) GI pipe light grade of total length 2.5 mts, (to be fabricated as per approved design),having angle of 120 C and to be supplied alongwith mounting clamps-02 Nos, fabricated from (65mm x 5mm)MS complete all as specified and directed by Engineer -in- chage . Note : The Contractor should fix te clamp as per site requirment.
Supply and fixing Junction box made of SMC/FRP sheet ready made of size 300 mm x 200 x 105 mm having 100 A Capacity RYB and neutral aluminium bus bar of 3 mm thick duly fitted on suitable insulator, and MCB SP 6 A 10 KA 240V -01 No. with fixing arrangement fixed properly to pole/fixed on wall with MS Clamps 25x5 mm and nut and bolts complete all as specified and directed by the Engineer-In-Charge.
Steel tubing galvanized(Light grade) 50mm bore conforming to IS -1239 for passing cable under road /floor or fixing to poles for protection of underground cable complete with flat iron 50x6 mm clamps made to shape and 12mm dia bolts, nuts and washers for fixing where required. (NOTE:- Excavation and earth work shall be measured and paid separatly)
PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete in foundation of pole/stays etc complete all as specified
PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete in foundation of pole/stays etc complete all as specified
PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in coping/above ground level around the pole etc complete all as specified.
Dismantling of ACSR or AAC conductors of any size and set in site complete all as specified.
Repair to DG set engine of capacity 40 KVA make kirloskar, 4 cylinder, 1500 RPM, water cooled model engine No. 4H.3002/0500005 by dismantling/strip opening of the DG set for overhauling by removing the cylinder heads, piston, connecting rod, cylinder liner, oil sump and injector etc. including calibration of engine and reassembling of the complete engine as per the manufactures instruction and testing on completion after replacement of unsv parts as mention below:- 1. Monoblock case-01 Nos 2. Crank shaft gear asly- 01 Nos 3. Piston assly- 04 Nos 4. Valve pair inlet and exhaust-08 Nos 5. Cyl liner assly- 04 Nos 6. Valve guide- 08 Nos 7. Valve steam seal- 08 Nos 8. Valve collect- 16 Nos 9. Bearing T/W - 01 Nos 10. Set of O ring- 01 set 11. Set of joints - 01 set 12. Cyl Head Gasket- 01 set 13. HP pipe- 01 Nos 14. Lube oil pump assly -01 set 15. Thermostate Assly-01 Nos 16.Con Rod Assly- 02 Nos 17. Valve Tappet-08 nos 18. Cap Assly- 01 Nos 19. Oil seal- 01 Nos 20.Primary Air Cleaner-01 Nos
21.Fuel pipe- 02Nos 22. LO supply Hose pipe- 01 Nos 23.Lube Oil cooler (3 plate)-01 set 24. Con rod bearing-01 set 25. Main Bearing- 01 set 26. Bearing Bush- 01 Set 27. Con Rod Bush-01 set 28. Bolt for head-06 Nos 29. Precoated Drain Plug- 01 Nos 30. Starter Ring -01 set 31. K Salent- 01 set 32. Fuel Filter Element- 01 set 33. Fuel filter element sec- 01 Nos 34. Spinion Lub Oil filter -01 Nos 35. Koel Engine oil- 25 Ltr 36. Koel care coolant 37. Bush for injector- 04 Nos 38. Set of copper washer - 01 set 39. Cyl head valve guide fitting- 01 job 40. Crank shaft grinding- 01 Job 41. Self starter calibration -01 Job 42. Charging Alternator-01 job 43. Labour Charges- 01 job
S&F in replacement maintenance free lead acid battery 12 volts 180 AH complete all as specified and directed
Repair to battery charger unit 40 KVA DG set including rewinding of transformer, replacement of rectifier plate, crocodile grip & flexible copper conductor 6 sqmm upto a length of 10 mtr complete all as specified and directed
Supply and fix in replacement automatic voltage regulator (AVR) suitable for 40 KVA DG Set complete all as specified and directed
Cleaning of radiator with the help of descaling agent/solution including repairs to the tubes and replacement of wornout rubber hoses complete all as specified and directed for 40 KVA DG Set.
Supply and installed Desert Cooler electric driven (Single phase) having nominal air flow capacity of 4000 Cum per hour of steel body duly fitted not below 26 guage thickness of GI sheet size of front grill not less than 620 x 545 x 75 mm and size of water tank not less than 680 x 680 x 180 mm and 1250 RPM totaly enclosed and all as specified and directed.
Supply, installation and commissioning of Refrigerator partially stainless steel, electric driven, single phase having capacity 315 Ltr, BEE 3 Star rated with stand complete all as specified and directed.
Supply and fix gun metal gate valve 20 mm bore with iron wheel screwed both ends for iron pipes complete all as specified and directed.
S&F 15 mm bore steel water tubing 'medium grade' galvanised with all fitting (i.e. Tee, socket, bend etd) complete to walls and trenches or laid in floors, complete all as specified and directed by Engr-in-Charge. (NOTE:- Excavation and earth work shall be measured and paid separatly)
S&F 20 mm bore steel water tubing 'medium grade' galvanised with all fitting (i.e. Tee, socket, bend etd) complete to walls and trenches or laid in floors, complete all as specified and directed by Engr-in-Charge. (NOTE:- Excavation and earth work shall be measured and paid separatly)
M&L for cutting og existing GI water main 50/40 mm dia, GI tubing including inserting GI tee of 20 mm and necessary fitting,joint complete all as specified and directed by Engineer- in-Charge.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 14,325.00 during AOC Note:- Tenderers shall not quote for this Schedule
ASHOKA ENGINEERS AND BUILDERS
MAMTA ENTERPRISES
proach associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .