Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC 90 E BECHARAM CHATTERJEE ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹16 L+₹1.4 L (9.22%)Rejected-Finance MOSAT HARIPUR RD VILL P O HARIPUR DIST HOOGHLY PIN 712701 | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L2 | Rejected-Finance Rejected as financial | |
| 3 | L3₹16.2 L+₹1.5 L (10.5%)Rejected-Finance FLAT 7 SRADHANJALI APARTMENT 393 3F 6 PRINCE ANWAR SHAH ROAD PODDAR NAGAR KOLKATA WEST BENGAL 700068 | KOLKATA | WEST BENGAL | 700068 | L3 | Rejected-Finance Rejected as financial | |
| 4 | Rejected-Technical ROOM NO 502 5TH FLOOR KAMLALAYA CENTRE DHARMATALA 156A LENIN SARANI KOLKATA WEST BENGAL 700013 | KOLKATA | WEST BENGAL | 700013 | - | Rejected-Technical DisDisqualified as Insuffient Creditional | |
| 5 | Rejected-Technical 45A 1 CENTRAL ROAD JADAVPUR N | - | Rejected-Technical Disqualified as Insuffient Creditional |
| Sl No | Description | Qty | Unit | MEGHJIT POWER SOLUTIONS LLP L3 | GHANASHYAM ELECTRIC STORES L2 | SIMPSON AND FERRIS PVT LTD L1 |
|---|---|---|---|---|---|---|
| 1.00 | SITC of 30 KVA UPS including Battery Bank of minimum 28800 VAH for each UPS (SMF Battery) 12 Volt Three phase Input / Three phase Output, inbuilt Isolation Transformer, static by pass arrangement, compatible with D.G. Set, DSP controlled IGBT based rectifier with minimum 90% efficiency on 100% Load. The UPS shall be provided with active input P.F. Correction system to obtain 0.9 lag at 100% resistive Load, Wave form - Pure line wave. It Should be capable of operating in 50’c above ambient temperature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by-pass ON, Over temperature. Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation.(2 nos in parallel)/ paralleing kit and suitable size battery rack.
(UPS Make: APC-Schneider Electric / NUMERIC/ Delta / VERTIV) | 2 | Sets | 8,09,698 ₹16,19,396 | 8,00,000 ₹16,00,000 | 7,35,020 ₹14,70,040 Lowest |
| 1.01Regulated Sealed Lead Acid Battery End Point Discharge Voltage should not less than 1.75V/Cell, Construction type : AGM or VRSLAB in ABS Flame Retardant Rating, 28080 VAH (for each UPS) (12V, SMF Battery) Back up time 30 Min at full load.Warranty : Two years on UPS and two Years on SMF Battery on site against any manufacturing defects. Certificate : ISO 9001:2015, ISO 14001:2015, IOS 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/ EN50091- 1,IEC/EN 60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2(EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture) (Battery Make Amararaja Quntra/ Exide Power Safe.) (fire Retardant) | ||||||
| 2.00The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules | ||||||
| 3.00Defect Liability Period - 2 (Two) years | ||||||
| 4.00Make & model of each and every material to be approved by EIC | ||||||
Tender Value
₹14.3 L
EMD Value
₹28,600
Closing Date
28 May 2025, 12:00 pmClosed
Exe.Engr.-I, Kol. South Health El. Divn. P.W.Dte
75 D H Road Kidderpore Kol_23
Emergent thorough renovation work of Electrical Installations , Air-Conditioning Systems and SITC of FDA Systems and online UPS System at Bio-Chemistry Lab and Ancillary areas of IOP Office Building, IOP-COE, Kolkata-25.-SITC of UPS
2025_WBPWD_840164_1
WBPWD/EE-I/KSHED/Q10/25-26
Open Tender
MISC ELECTRICAL WORKS
Item Rate
30 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹28,600
O/o Exe.Engr., Kol. South Health El. Divn. P.W.Dte
8 Sept 2026
29 Apr 2025
30 May 2025
29 Apr 2025
28 May 2025
7 May 2025
6 May 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .