EXECUTIVE ENGINEER BUILDING DIVISION LAKHISARAI
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER BUILDING DIVISION LAKHISARAI
SUPERINTENDING ENGINEER BUILDING CIRCLE MUNGER`
SE
CONSTRUCTION OF BLOCK BUILDING CUM CIRCLE OFFICE CUM RESIDENCE BUILDING AT RAMGADH CHAWK DISTRICT- LAKHISARAI. YEAR 2026-27
136164
NIT 04/BCD/LKH/2026-27
Open Tender
CIVIL
Lakhisarai
• Bid Security Amount in Rupees (A) Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given. 16.1 Total Bid Security Amount in Rupees Rs. 3986000.00 IFB
• (i) Legal Status of Bidder 4.3(a)
(ii) Place of Registration.
(iii) write Principal place of Business
(iv) Power of attorney of signatory Bid 4.2(iv)
• Total value of civil engineering construction work, in Rupees, Performed in last five years. Minimum annual financial turnover (in all classes of civil engineering construction works only) amount of construction work ,which must be at least equal to 50 % of estimated cost of works for which bid has been invited. The turn over will be indexed at the rate of 8% for a year 4.5(A) (a)
2020-21
2021-22
2022-23
2023-24
2024-25
• Amount in Rupees related to Work Experience of Similar nature Satisfactory completed at least one similar work of value not less than 50% of estimated Cost .5(A) (b)
• (c) Executed in any one year, the minimum quantities /amount of the following items of work (units shall be same as in Requirement column). Items Qty Unit 4.5A( c)
S. NO. ITEM Unit 50%
1 Earth work M3 3838.79
2 Local Sand M3 1798.43
3 PCC +RCC M3 3911.44
4 Reinforcement Kg 291462.77
5 Flooring M2 4462.88
6 Brick Work M3 1821.06
7 PHE Work Rs 42,11,192.50
8 Furniture Rs 49,69,337.50
9 Fire fight work Rs 17,44,391.50
10 Electrification Rs 1,56,02,527.00
• (a) Amount of Existing commitments and ongoing works in Rupees Sec 2-1.4(A)
• (b) Amount of Work for which Bid already submitted, in Rupees Sec 2-1.4(B)
• Numbers and Maximum age of Equipment with bidder Type of Equipment Nos. Maxm. Age 5 Year
Concrete Batching & Mixing plant Minimum capacity 15m3/hr . 5 1
Pump for concreting 5 1
Transit Mixture 5 1
Vibrator (Plate & Niddle) 5 5
Water Tanker 5 2
Steel shuttering 5 10000sft
• Name of the Personnel and Experince in years and Select from drop down list Personnel / Qualification 4.5(B) (b)
Project Manager B.E. Civil + 10 Years Exp. (5 years as Manager having MBA) or equivalent or retired E.E. 1 No.
Site Engineer B.E. (Civil) + 03 Years Exp. (3 years in Building Construction) or Diploma in Civil + 7 year Exp. In Building construction or retired A.E. 2No
Plant Engineer B.E. Mech./ Civil + 03 Years Exp. or Dip. Mech + 05 Years Exp. or Retired J.E. 1 No.
Quantity Surveyor B.E. Civil + 03 Years Exp. or Dip. Civil + 05 Years Exp. 1 No.
Site Supervisor Fresh Graduate in Civil or Diploma Civil + 02 Years Exp. or retired I.T.I Holder. 3 Nos.
• Evidence of accesses to Financial Resources in Rupees Evidence of access to or availability of credit facilities (10% of estimated cost), certified by bankers (for work under this bid). 4.2(i)
• Proposed methodology and programmer of construction Select from drop down list the proposed methodology and programmer of construction, backed with equipment planning and deployment 4.3(l)
• Litigation History. Select from drop down list. Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount. (Attached or not) 4.3(j)
• Affidavit Select from drop down list. Regarding statements made in the required attachments are true and correct. Sec-2, Affidavit
• Undertaking Select from drop down list. Able to invest a minimum of cost up to 25% of contract value of work. During implementation of contract. Sec-2, Undertaking
• Registration No. IT.& ST Registration & clearance Certificate Labour License Character Certificate NOC for Debar (If required)
CIVIL
PERCENTAGE
L1
1
22 documents required · 22 mandatory
₹10,000
Processing Fee: 11800
₹39.9 L
AT CE SOUTH BCD PATNA OFFICE, 24-07-2026 03:00 pm
15 Jul 2026
15 Jul 2026
12 Aug 2026
15 Jul 2026
11 Aug 2026
15 Jul 2026
18 Jul 2026
Earth work in excavation in foundation trenches or drains (not excoding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the exvavted soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Extra for every additional lift of 1.5 m or part thereof in
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth : consolidating each deposited layer by ramming and watering lead.
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Clearing jungle including uprooting or rank vegetation, grass, brush wood, trees and scaplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Beyond 40 cm girth up to and including 60 cm grith
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Turfing with Sods (Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the engineer including preparation of ground, fetching of rods and watering)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.
1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1.4.8 (1 Cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size)
1:3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by the manufacturers.
Centring and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc., for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Shelves (Cast in situ)
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Post and struts
Stairs, (excluding landings) except spiral staircases.
Vertical and Horizontal fins individually or forming box louvers band, facias ane eaves boards.
Wheather shade, Chajja, corbels etc., including edges.
Edges of slabs and breaks in floors and walls :
Extra for shuttering in circular work (20% of respective centring and shuttering items)
Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc, including cost of de-shutering and de centring at all levels over a height of 3.5 m, for every additional height of 1 meter of part thereof (plan area to be measured)
Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete.
TMT-500- 8mm dia .
TMT-500-10 mm dia.
TMT-500-12 mm dia
TMT-500-16 mm dia.
TMT-500-20 mm dia.
TMT-500-25 mm dia
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
Concrete of M-25 grade with minimum cement content of 330 kg/cum
Concrete of M-25 grade with minimum cement content of 350 kg/cum
Concrete of M-25 grade with minimum cement content of 330 kg/cum
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level
Brick work with fly ash bricks as per IS 12894 (2002) & IS 3495 in foundations and plinth in :
Half brick Masonary Cement mortar 1.:4 (1 cement: 4 coarse sand ) - 125 mm th Brick work
Extra tor Brick work in superstructure above plinth level upto floor V cum
Extra for providing and placing in position 2 Nos, 6 mm dia , MS bars at every third course of half brick masonry (with F. P. S. bricks)
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S.pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin-charge
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:
Providing and fixing aluminium sliding door bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ), transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (Over all area of door shutter to be measured).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:
Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C.doors) using synthetic rubber based adhesive.
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed onthe body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked, including top cover of 6 mm commercial ply wood conforming to IS: 303 BWR grade, nickel plated M.S. pipe 20 mmdia ( heavy type ) curtain rod with nickel plated brackets, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete.
Providing and fixing teak wood lipping of size 25x3 mm in pelmet.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - incharge. (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing non load bearing fixed frame for fire resistant glazed Partition for 120 min Fire Rating, made out to a profile of dimension 60mm x 70 mm of 1.6 mm thick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for 120 min of both integrity & radiation control (EW120) & minimum 15 min of insulation (El15). The profile has to be fixed to the supporting construction by means of anchor fasteners of size M10 x 80, every 150 mm from the edges and every 500 mm (approx) c/c. Linear meaurement of frame shall be measured for payment. The frame shall be filled with mineral wool insulation of density min 96kg/m³. and finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer -incharge.
Providing and fixing pressed steel door frame confirming IS code 351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-Charge.
Providing and fixing ISI marked steel glazed door, windows and ventilators of standard rolled steel section & joints mitered and welded with 15x3 mm lugs, 10cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawls plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with glazing clips and special metal sash putty of approved make complete including applying a priming coat of approved steel primer, but excluding the cost of steel beading and other fittings except necessary hinges or pivots as required.
Providing and fixing bright finished brass peg stays to steel ventilators with necessary welding and machine screws etc. complete.
Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete.
Steel work welded in built up section/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Extra for providing and fixing steel beading of approved shape and section with screws instead of glaxing clips and met. Sash putty in steel doors, windows, Ventilators and comosite units.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-iron 40x40x6 mm with 40 mm dia steel pulleys complete with bots. Nuts locking arrangement stoppers handles including applying a priming coat of approved steel primer
Providing and fixing hand rail welding etc.to steel ladder ralling & staricases railing including
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / neling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-charge. (The item includes cost of fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account)
Designing, fabricating , testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the buildings for all heights and all levels,including
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc.
Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete.
Providing flyash one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I.
Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1 st quality conforming to IS : 13755 of NITCO , ORIENT , SOMANY , KAJARIA or equivalent make in colours such as white , Ivory , Grey , Fume , Red , Brown , laid on 20 mm thick cement motar 1:4 (1 cement: 4 Coarse sand) including grouting the joints with white cement and matching pigments etc, complete.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Motar 1:3 (1cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) /1:4 (1 cement : 4 coarse sand)
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with:
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Area of slab upto 0.50 sqm
Area of slab over 0.50 sqm
Extra for Kota stone / sand stone in treads of steps and risers using single up to 1.05 metre.length
Extra for pre finished nosing in treads of steps of Kota stone / sand stone slab.
Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc.
Providing edge moulding to 18 mm thick marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in Charge
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622, of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Stone tile (polished) work for wall lining over 12 thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and cement slurry @ 3.3 kg / sqm including pointing in white cement complete
12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of neat cement
12 mm cement plaster of mix
1:3(1 Cement :3 coarse sand)
1:4(1 Cement :4 coarse sand)
1:6 (1 cement : 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix.
15mm cement plaster 1:3 (1cement : 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall
6 mm cement plaster to ceiling of mix.
1:3(1 Cement :3 coarse sand)
1:4 (1 cement : 4 coarse sand)
Distempering with 1st quality washable distemper (ready made ) of approved manufacturer and of required shade and colour complete. As per manufacture's specifications.
Applying priming coat:
With ready mixed pink or grey primer of approved brand and manufacture on woodwork (hard and soft wood)
With ready mixed red oxide zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works
Finishing walls with Acrylic Smooth exterior paint of required shade :
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
Painting with synthetic enamel paint of approved brand and manufacture to give an even shed.
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Forming groove of uniform size from 12 x 12 mm and upto 25 x 15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
Neat Cement punning
Applying one coat of cement primer of approved brand and manufacture on wall surface :
Stone work (machine cut edge) for wall lining etc. (veneer work) over 12 mm thick bed of cement lime mortar 1:1:6 (1cement : 1 lime putty : 6 fine sand) including pointing in white cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid for seperately)
Providing and fixing gun metal cramps of required shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 ( 1cement : 2 fine sand) including making the necessary chases.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part there of
Extra for plastering :
Finishing walls with Premium Acrylic smooth exterior paint with silicone additives of required shade.
Finishing walls with textured exterior of required shade :
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed protions of W.C. kitchen and the like consisting of :
Grading roof for water proofing treatment with
Providing and Laying APP (Atactic Polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre /sqm by the same membrane manufacture of density at 250 C, 0.87-0.89 kg / litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The Vital physical and chemical parameters of the membrane shall be as under : Joint strength in logitudinal and transverse direction at 230 C as 650/ 450N / 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 1500C. Cold flexibility shall be upto -20C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100%polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing plain cement concrete in (1:2:4) including making grooves laid in pattern of tiles 300 x 300 mm avg. thickness 40 mm on sloped roof as per drawings all complete.
Making khurras 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1cement:3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
Providing and fixing sheet covering over expansion joints with iron screws as per design to match the colour / shade of wall treatment.
Providing and filling in position bitumen mix filler of Proportion 80 kg of hot bitumen, 1 kg, of c ement and 0.25 cubicmetre of coarse sand for expansion joints,
Supplying chemical emulsion in sealed containers including delivery as specified.
Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termites' treatrnent (including the cost of chemical emulsion)
Along external wall where the apron is not provided using chemical imulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete.
Along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand ) to match the existing floor.
Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I.
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base.the drain duly.plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l,
Flat frame technology of required dimension to form suggested usage/made up of Aluminium Extruded Section,duly anodised All signage
Supplying and fixing C.I. cover without frame for manholes :
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
Providing and fixing vent pipes :
Providing and fixing in position 25mm diameter mosquito proof coupling of approved municipal design
Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of / and manure before and after flooring trench with water (excluding cost of imported earth, sludge or manure)
Supplying and stacking of good earth at site including royalty but excluding carriage (earth measured in stacks will be reduced by 20 % for payment)
Supplying and stacking at site dump manure from approved source, excluding carriage (manure measured in stacks will be reduced by 8% for payment)
Mixing earth and sludge or manure in proportion specified or directed.
Spreading of sludge, dump manutre or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately)
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking clods, rought dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.
Grassing with 'Doob' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free form weeds and fit for moving including supplying good earth if needed.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20 % 1 part of stacked volume of manure after reduction by 8 % ) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure sludge or extra good earth if needed to be paid for separately)
Holes 1.2 m dia. And 1.2 m deep.
Holes 60 cm dia. And 60 cm deep.
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8 :1 (8 parts of stacked volume of earth after reduction by 8% ) flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)
Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge.
Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v
Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge.
Providing and stacking of Hamelia patens of height 90-105 cm. bushy in big size HDPE bags as per direction of the officer-in-charge.
Providing and stacking of Mussaenda erythrophylla (Rosea) of height 60- 75 cm. multi branched in earthen pots of size 25 cm as per direction of the officer-in-charge.
Compacting original ground Compacting original ground supporting subgrade (Loosening of the ground upto a level of 500 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of table 300-2 for subgrade construction)
Construction of subgrade and Earthen Shoulder (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2)
Granular Sub-Base with Graded Material ( Table:- 400- 1) Plant Mix Method (Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.)
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge:
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including, cutting and making good the walls etc. (internal work)
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc . (external work)
Providing and fixing brass bib cock of approved quality.
Providing and fixing brass stop cock of approved quality (screwed end).
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end).
Providing and fixing gun metal non-return valve of approved quality (screwed end)
50mm nominal bore
32mm nominal bore
32mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation,refilling the earth or cutting of wall and making good the same complete wherever required :
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Providing and fixing P V C connection pipe with brass unions.
Providing and fixing C.P. brass shower rose 15 or 20 mm inlet.
Constructing masonry Chamber 30 x 30 x 50 cm inside, in brick work in cement mortar 1:4( 1 cement: 4 coarse sand) for stop cock, with C.I surface box 100 x 100 x 75 mm(inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation, foundation concrete 1:5:10( 1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:
Constructing masonry Chamber 60 x 60 x 75 cm inside, in brick work in cement mortar 1:4(1 cement: 4 coarse sand) for sluice valve, with C.I surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necesary excavation, foundation concrete 1:5:10( 1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3( 1 cement: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:nt complete as per standard design.
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :
Providing & filling sand of grading zone V or coarser grade all-around G.I. pipes in external work.
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc.complete (new work)
Providing and fixing C.P. brass,bib cock of approved quality conforming to IS : 8931
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS stamdards and weighing notless than 810 gms.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS stamdards and weighing notless than 690 gms.
Providing and fixing C.P brass stop cock (concealed) of standard design and of approved mark conforming to IS:8931
Providing and fixing C.P brass angle valve for basin mixer and gyser points of approved quality conforming to IS: 8931
Providing and fixing PTMT Soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Cutting holes up to 30 x 30 cm in walls including making good the same:
Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including finishing complete so as to make it leak proof.
Making holes up to 20 x 20 cm and embedding pipes upto 150 mm in diametre in masonary and filling with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) including dispopsal of malba.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
Provoding and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug , 40 mm C.P brass waste complete, including painting the fittings and brackets, cutting and making good the walls whereever required.
Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5 mm glass shelf with edges round off,supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
Providing and fixing soil, waste and vent pipes
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),including cost of cutting holes and making good the walls etc. :
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick bolts and nutts complete
Providing and fixing plain bend of required degree
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete
Providing and fixing single equal plain junction of required degree :100x100x100 mm
Providing and fixing terminal guard
Providing lead caulked joints to sand cast iron/ centrifugally cast (spun) iron pipes and fittings of diameter
Providing and fixing trap of self cleaning design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.
Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :
Providing and fixing on wall face unplasticised PVC (working pressure 4 kg per sqcm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
Providing and fixing on wall face unplasticised PVC moulded fittings / accessories for unplasticised-PVC rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
Single pushfit Coupler:
Single tee with door
Shoe plain
Providing and fixing unplasticised-PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S screws or required length including cutting brick work and fixing on cement mortar (1:4) 1 cement:4 coarse sand and making good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :
Providing and fixing white vitreous china pedastal type water closet (European type W.C pan) with seat and lid, 10 litre low level white P.V.C flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions G.I. clamps, complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:
Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C.automatic flushing cistern, with fittings, standard size G.I. / PVCflush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required :
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone finished smooth.aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distances of 37mm fromwall face with concealed fittings arrangement of approved quality, and colour, weighing not less than 88 gms.
Cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement: 3 coarse sand : 6 graded stonea agregate 12.5mm nominal size) including necessry plaster and pointing in cement mortar 1:4 ( 1 cement: 4 coarse sand):
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes inlcuding bed concrete as per standard design.
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
Providing and laying non-pressure NP2 class (light duty) R.CC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2( 1 cement: 2 fine sand) including testing of joints etc. complete.
Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.
Constructing brick masonry manhole in cement mortar 1:4(1 cement: 4 coarse sand) with R.C.C top slab with 1:2:4 mix (1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand:8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3( 1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design:
Extra for depth for manholes Size 90 x 80 cm with common burnt clay F.P.S (non modular) bricks of class designation 7.5
Constructing brick masonry chamber for underground C.I inspection chamber and bends with bricks in cement mortar 1:4( 1 cement: 4 coarse sand) C.I cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg) R.C.C top slab ith 1:2:4 mix ( 1 cement: 2 coarse sand:4 graded stone aggregate 20mm nominal size) foundtion concrete 1:5:10( 1 cement: 5 fine sand:10 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
Extra for depth beyond 45 cm of brick masonry chambar For 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe,removable as per requirement, all complete for borewell of:
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia
Gravel packing in tubewell construction in accordance with IS:4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Supply fixing 2 HP Motor Pump (1 Unit) with 32 mm dia clamp (1 Unit), Suitable Length of cable, Panel Board & Starter (1 No.), centre Guide ( 6 Nos.) Machine Up and Down etc. all complete
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking TGrid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The
Providing, fittings & fixing vertical venetian blinds (of vista, mac make) to window made with aluminium slate or approved thickness, colour quality with all accessories including adjuster, hardworks complete with all labour and materials in all floors.Design and colour to be approved first by Engineer-in-Charge.
Providing and fixing anodised aluminium work for doors, windows, ventilator? and partitions with extruded built up standard tubular and otner sections of approved make conforming to IS : 733 and IS : 1285,anodised trasparent or dyed to required shade according to IS : 1868,(Minimum anodic coating of grade AC 15), fixed with.rawl plugs and screws or with fixing clips , or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust fre straight, mitred and jointed mechanically wherever required including cleat angle,.Aluminium snap beading tor glazing/paneling, C.P. brass/stainless steel screws, all complete as per architecttural drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately.)
Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Providing & fixing of Aluminium Framed preliminated painted board complete wirth fixing of room no. / name plate / exit route in Hostel rooms & chambers of Institute block and hostel as per choice of client / E/I
Full height storage (size : 1200 L x 1975 H x 600 D) for Record room Making, supply and installation of Wooden Wardrob, 600mm deep, the sides, Top of B.W.P. lesard with 1.0 mm laminates finish. 12 mm thick B.W.P. Ply The front shutter with 19 mm thick B.W.P. Ply wood of century ply or equivalent with 1.0 mm thick. laminates movable roller, channel, recess knob Itallica Locks glass etc. including all fitting & fixture shall be complete in all respect. as per drawing and direction of E/I.
Storage Unit Low Height for Officer chamber (size :1050L x 430W x 750H) Supply , Fabrication and Installation of low height storage unit. The structure of made out of 18mm thick pre-laminated board (PLB). The shelves are made out of 18mm thick (PLB) , which are adjustable in height. The shutters are made out of 18 mm (PLB) openable and fitted by hinges, recessed handles, locking unit and levelers are considered, all complete as per drawing and directly of E/I.
Information Desk : (3775 x 750 x 900 h) Supplying and fixing Information Desk made of 25 mm thick prelaminated board top with PVC edge binding on wooden frame completes with shelves, key board and CPU Trolley, wire manager with all hardware. Internal wooden surface polished all complete per drawing and direction of E.I.
Interaction Countre : Size (4200 mm x 750 x 900 H) Supplying and fixing Interaction Countre made of 25 mm thick prelaminated board top with PVC edge binding on wooden frame completes with shelves, key board and CPU Trolley, wire manager with all hardware. Internal wooden surface polished all complete per drawing and direction of E.I.
Side table (size : 510 x 440 x 450mm) Supply,Fabrication & Installation of side table made of prelaminated board top matched with bed finish , with all necessary fixtures and fittings complete as per drawing and direction of E/I.
Canteen Table - (Size : 900 x 900) - Supply Fabrication and Installation of rectangular table of size (900 x 900 x 750 H) with preliminated Particle board top over chrome base leg all complete as per drawing design and direction of E/I.
Dining Table (Dining room of Guest House) - Size : (2000 x 800 x 750 mm H) - Supply Fabrication & Installation of Dining Table top of 19 mm thick PVC laminated board with 2 mm thick PVC edge banding , supported with M.S Rolling sqaure section framed complete with all fittings and assessories as per drawing & direction of E/I.
Meeting Table / Confrence Table - 22 persons Size : (5400 mm x 750mm x 900mm Ht.)
Executive table with return unit –
Sr.officers Table (size : 1350 x 750 x 750 mm)
Works station / Computer table (Size 1050 x 450 x 750mm (H)) Supply of Computer table made of 25 mm thick pre laminated particle board work top the tables will be lipped with PVC edge band of 2.0 mm thickness with frames : 50 mm thick and 1050 Ht , Base 700 mm five pronged base is made out of GF nylon - 6with an embedded metal rings and bottom ribs for additional support and strength lockable drawer unit and CPU stand wire manager at Top complete as per drawing design and direction of E/I.
Supplying, Fitting and Fixing of 3 seater chair (Chrome)
Supplying, Fitting and Fixing of Officer's Chair (Medium back) -
Supplying, Fitting and Fixing of Computer staff / visitor's chair (low back) -
Dining Chair - Supply , Fabrication and installation of dining chair with solid beech wood frame and legs with melamine polish. The seat and back rest shall be fully uphole stered with leatherlite / Fabric finish All complete as per drawing design and direction of E/I.
Dining Chair (Stackable ) for SHG Hall - Plastic Seat & BAck Without Arms and with Powdercoated Legs 'Providing and Fixing Featherlite Make MAGNA Chair The frame is made out of 22mm tube of 16gauge tube Welded by Co2 welding process for uniform surface, Thermo set powder coating epoxy polyester hybrids of harness (pencil) H.B.74 and impact resistant (in lab) 60-160 kgs cm and to a thickness of 40-50 microns is carried out of 7 step pretreatment process. The Back Shell is made out of Talc filled 10% poly propylene co polymer molded with ergonomic see through design
Godrej reception table size 2410x1065x725 work surface
Cantilever chair
Table with side unit return
Compactor
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc and disposing of surplus excavated soil as directed , within a lead of 50 m
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubbergasket, GI bolts, nuts, washers etc.as required :
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless steel (Grade 304)
Providing and fixing fully glazed MS fully welded construction double leaf door shutter for fire hydrant station fabricated from MS 50x50x6 mm angle iron frame, fixed to wall and hinged MS 40x40x5 mm angle iron door shutter with required MS sash bars for glazing complete with locking arrangements, stove enamelled fire red finish with 'FIRE HYDRANT' written in front. Approximate size 2100x900mm.
Providing and placing in proper position Stainless Steel 63mm dia short size branch pipes with 20 mm dia nozzles with 63mm instantaneous coupling ISI marked (IS:903).
Providing and fixing brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 and spindle AISI 410) with setting and gland of superior quality having minimum working pressure of 20 kg/cm2. 25mm dia
Supply, installation, testing & commissioning of 25mm dia air release valves of approved make on the top of each 150mm dia basement sprinkler ring main as per standard fire practice
Providing and fixing pressure gauges with isolation cocks and chrome plated copper pipes as hydrant station to read pressure from 0-25 kg/cm2 complete and of dial dia 150 mm.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipecoupling as required :
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft,mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation,conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.
a) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. c) SuitableHP squirell cage induction motor TEFC type suitablefor operation on 415 volts, 3 phase 50 Hz AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. d) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. e) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required
Providing and fixing motor control centres fabricated from 16 gauge M.S. sheet with Powder Coated finish. The control panels should be compatible with H.P. of the motor as under and as per spcifications with automatic star delta starters. (One separate panel to be located in the plant room).
Providing and fixing heavy duty Aluminum armored cables 1.1 KV grade including necessary support clamps at ceiling level, connection lugs and double compression glands, complete in all respects.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Supply, Installation, Testing & Commissioning of ISI marked (IS:15683) Portable fire extinguisher, of 4.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Supply, Installation, Testing & Commissioning of ISI marked (IS:2878) Portable fire extinguisher, of 22.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Providing, fixing, testing & commissioning of horizontal pumping set with stainless steel SS-304 stage casing and SS304 impellers with stainless steel SS304 shaft as per IEC standards and GJL250 cast iron suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440 volts, 3 phase, 50 Hz AC supply with pressure gauge and with gunmetal isolation cocks, vibration elimination pads etc. complete with base and frame, nuts and bolts and necessary RCC foundations as per requirement as per instructions and pump shall have following duty.
Pumps for Domestic Water Supply (Hydropneumatic)
Pressure Filter (Domestic Water)
Water Softener
Providing,fixing, testing & Commissioning of G.I. pipes (IS:1239 heavy class) complete with GI fittings ie tees, elbows, sockets, clamps etc including painting of approved specifications, MS structural supports and hangers as required (as per approved shop drawings) as per instructions of Engineer-In-charge.
Providing and fixing standard G.I. flanges, (only in valves, strainers, expansion joint and pumps matching flanges) screwed or welded complete with 1.5mm thick compressed asbestos gasket, nuts, bolts and washers etc., complete including testing of joints. The flanges shall be as per I.S:6392 - 1971 table E.
Providing and fixing rubber expansion joints (to provide relief from stresses at pipe flanges) as per specification of the manufacturers i.e. M/s Kanwal Industrial corporation,
Providing,fixing, testing & Commissioning of C.I double flanges suction “Y” type including, nuts, bolts and 3mm thick rubber insertion complete.
Providing,fixing, testing & Commissioning of butterfly valves, wafer end type class PN 1.6 as per I.S:13095 or BS:5155, including necessary nuts, bolts, gaskets etc. complete (without gear box)
Providing, fixing, testing & Commissioning of forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finish with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 10 kg/cm2 etc. complete in all respect.
Providing,fixing, testing & Commissioning of gunmetal non-return valves vertical or horizontal tested to 20 kg/cm2 as per IS:778.
Providing, fixing, testing & commissioning of CI double flanged horizontal/ vertical type non-return valve including nuts, bolts, 3mm thick rubber insertions complete to IS:5312, Part-I, swing type, class PN1.6
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'C' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in center of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: underground tanks)
Providing, installing, testing & commissioning of Main Electrical Panel -Motor Control Centre fabricated from 16 gauge MS sheet with powder coated finish. The control panels should be comparable with HP of the motor as specified and as per specifications provided.
PANEL - A ( In Plumbing Plant Room)
Providing, fixing, testing & commissioning of heavy duty copper armored cables 1.1 KV grade including necessary support clamps at ceiling level/ walls and connection legs complete in all respects.
Providing, fixing, testing & commissioning of heavy duty Copper/Aluminium armored cables 1.1 KV grade including necessary support clamps at ceiling level, connection lugs and double compression glands, complete in all respects.
Providing,fixing, testing & Commissioning of GI earthing wire 8 gauge betwen all motors and MCC panel to be connected in approved manner to the general earthing system complete.
Providing,fixing, testing & Commissioning of GI earthing strip of size 25x 3mm for higher size motors and MCC panels to be connected in as approved manner to the general earthing system complete.
Providing, fixing, testing & commissioning of Pressure Gauge in SS-316 (glycerine filled) for min. 0-300 psi round dial of 100mm size with threaded nipple, unions, coupling etc including standard fittings.
Providing and fixing Manhole Cover for U.G Tanks -Providing and fixing extra heavy duty 560mm dia, double seal, water tight DI manhole cover and frame for placing over the underground water tanks with lifting and locking arrangements as per approved sample, complete in all respect including fixing in PCC as per site requirement.
Providing and fixing electrically operated motorised valves with level controllers in SS body, for min. working pressure of 10 kg/cm2, complete with all necessary accessories and electrical devices.
Providing, fixing, testing & commissioning of automatic chemical dozing system consisting of electronic dosing pump, suitable to doze chemical solution as per requirement with a dosing capacity of (0-12 lph) for dosing of appx. 2 ppm of chemical to a flow of water of 50,000 to 100,000 lph. against a pressure of 50-60 psi complete with FRP moulded solution holding tank of 100 litre with all standard accessories.
Details of Items
Wiring for light point/ fan point/ exhaust fan point/ Call bell Point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable size G.I box etc. as required. Group - 'C'
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular switch box including connection but excluding modular plate etc. as required.
Supplying and fixing suitable size G.I box with modular plate and cover in front on surface or in recess including providing and fixing 5 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc, as required.
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc, as required.
Supplying and fixing 2 pin, 5 amp. ceiling rose on the existing junction box/PVC box including connection etc as required.
Supplying and fixing batten/angle holder including connection etc. as required.
Supplying and fixing Ding-Dong call bell suitable for single phase, 230 volts complete as required.
Supplying and fixing following modules G.I. box along with modular base and cover plate for modular switches in recess etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 nos. 5 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following way three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator)
Supplying and fixing following rating, 240 volts, ‘C’ series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following ways, surface/recess mounting, Vertical three phase distribution board ( VTPN DB's ) of CRCA sheet steel, dust protected, duly powder painted suitable for upto 250 amp, four pole MCCB as Incomer and SP/TP MCB's as outgoing inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's etc as required. (but without MCCB & MCBs),Legrand/Scneider.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing recess/surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Supply and fixing of following sweep/ sizes PVC/ABS square body Exhaust Fan with automatic openable louvre shutter in existing opening including making connection, testing etc as required.
Supply and installation of 600 mm, 230 V A.C. wall mounted Air circulator, heavy duty fan including fixing the bracket, making connection, testing, commissioning etc as required.
Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supply of following sizes and core XLPE/PVC insulated PVC sheathed (Heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1.1 KV as required.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cble of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc as required.
Supplying and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley internal wiring, earth terminals, Bus bar Chamber, Insulator and complete in all respect etc and panel manufacturers must be approved by CPRI. (But without RYB inicator , ammeter, voltmeter, inter-connection copper conductor cable / solid copper strip, switchgears etc.
Supplying and fixing of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc.as required.
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
50 mm X 5 mm copper strip (2.30 Kg/mtr)
Suppy and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required.
Providing and fixing MV danger notice plate of 200mm x 150 mm made of mild steel at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side etc as required.
FIRE SUPPPRESSION SYSTEM
SITC of 5.0 LB Novec 1230/FK-5-1-12
SITC lienear pneumatic heat Detection.
SITC of Master control unit for controlling each system, complete with pressure switches, buzzers and electronic hooter, including all necessary accessories + electrical wiring to make entire system functional (Make :- Fireterx/tracefire/Safefire).
Rubber mat of 16 mm thik and 1000mm wide to with stand 15kv dielectric strength as per is 5424.1969
Shock treatment chart in English and local language duly framed with glass.
First aid box complete with all standard first aid materials.
Rubber gloves 11 KV grade as per IS 4770-68
Earthing with G.I. plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with salt and charcoal / coke as required.
Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supply and erection of 6 metre height Hot-dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 X 220 X 12 mm , small door opening for junction box mounting including 6A 'C' series SP MCB, connector, and suitable size foundation bolts with template as required.(but without pole foundation)
Providing and making of following sizes octagonal street light pole foundation in reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) of specified size including PVC conduit, form work, curing, reinforcement, excavation and refilling etc. as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supply of following sizes and core XLPE/PVC insulated PVC sheathed (Heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1.1 KV as required.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cble of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc. as required.
Supplying and connection of following sizes ISI marked FR PVC insulated, single core copper conductor cable etc as reqd.
Fabrication, supply, Installation testing and commissioning of Street Light Feeder Pillar of cubical construction, floor mounted type, fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, digital ammeter & voltmeter, RYB LED lamp, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals etc. complete in all respect, suitable for following incoming and Outgoings as required. (CPRI Approved Panel Mfg.)
Supply, Installation, testing & commissioning 200 KVA, 11 K V / 433 V, 50 Hz, 3 phase Delta / Star connected, copper wound ONAN Transformer with Dyn-11 vector group suitable for out-door, floor mounting. The transformer shall have OFF Load taps in steps of +/- 2.5 % and +/-5 %, complete with first fill of oil and shall conform to I S : 2026 - 2011 & IS : 1180 (Level-2) : 2014 (latest edition). H. T. & L. T. sides of the transformer shall be suitable for cable termination box / Busduct Termination box complete with cable end-boxes as follows: Make:-kotsons/Powerstar /kirloskar/crompton HT SIDE: 11 KV ,3C X120MM XLPE CABLE ,LT SIDE:,2 X 3.5 X185 Sq. mm. XLPE CABLE Transformer shall have provided with winding over temperature indication and trip devices.
Supply ,Installation, testing and commissioning of 2 Pole mounted DP providing I no 11kv,400A GOC in accordence with ie rules& local authority specifications and drawing and comprasing the following
Supply, Installation, testing and commissioning of silent type DG set comprising with diesel engine water cooled , synchonous alternator , AMF panel three phase , acoustic enclosure, battery with charger and related accessories, including PCC 1:2:4 platform, incoming cable 10 meter, earthing GI/CU plate 2 nos. including exhaust pipe B class with insulation as per CPCB IV+ norms etc as required. Make:- Kirloskar/ Ashok Leyland/Cummins.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power H.T. cable with aluminium conductor for working voltage upto 11 KV as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Supply of following sizes and core XLPE/PVC insulated PVC sheathed (Heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1.1 KV as required.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cble of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required.(Including 5.36% GST)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. In the existing trench, complete as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. (For Transformer Neutral and Feeder panel)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Suuply, Installation, testing and commissioning of a fully enclosed type 100 KVAR capacitor panel, dust vermin and IP 55 protected, fabricated out of 14 guage MS sheet duly DPC coated including interconnections, relays specified as below complete as required.
SITC of 2MP IR Bullet Fixed lens Camera -1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S), support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Video tampering, UL, CE, FCC certified. (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 2MP IR Indoor Dome Fixed lens Camera- 1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, Color: 0.01 Lux at F1.2, ICR, ONVIF, support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Tripple individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, IK10, Edge Anlalytics- Line crossing detection, intrusion detection, Motion detection, video tampering, UL, CE, FCC certified. (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 2MP IR Outdoor PTZ Camera - 1/2.8" Progressive Scan CMOS, 1920 × 1080 at 60fps, 4.8 mm to 153 mm, 32× Optical, 16x digital zoom, Color: 0.005 Lux at F1.6, B/W: 0.001 Lux at F1.6, ICR, ONVIF, support H.265,MJPEG, 120 dB WDR, 3D Digital Noise Reduction, HLC, BLC, Defog, EIS, Tripple individually configurable stream, 24 VAC & Hi PoE, IR range: 150m, Pan: 360° endless, Tilt: From -15° to 90° (auto-flip), Pan Speed - from 0.1°/s to 160°/s, Preset Speed: 240°/s, Tilt Speed- from 0.1°/s to 120°/s, Preset Speed: 200°/s, Presets- 300, Alarm Input-2-ch alarm input, Alarm Output-1-ch alarm output, Audio-1 channel input & output, Support on-board storage up to 256 GB (SD card not included), IP66, IK10, Face Detection, Intrusion Detection, Line Crossing Detection, Region Entrance Detection, Region Exiting Detection, UL, CE, FCC certified. (Hi-PoE injector under Si Scope, if PoE is used)(Vertical Pole Mounting Bracket)) (Approved Makes: Hikvision/ Honeywell/ Bosch) /Equivalent
SITC of 32ch Network Video Recorder - Connect Up to 64 IP Cameras, Dual OS, Up to 12 Megapixels Resolution, Two independent HDMI outputs, one HDMI output of 4K resolution,1 VGA output with output upto 1920 × 1080, Support H.265, MJPEG, Supports N+1 hot spare system,Supports RAID0, RAID1, RAID5, RAID6 and RAID10 ,Supports HDD hot swap, Supports Dual Power-Redundant, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 6TB, 3 × USB at least 1 × USB with 3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. (Makes: Hikvision/ Honeywell/ Bosch)
SITC of 6TB Surveillance Hard Disk Custom-built for surveillance applications with Image Perfect firmware for crisp, clear, 24×7 video workloads Maximum 180TB/year workload rating—3× the workload rating of desktop drives—for reliable performance in write-intensive surveillance systems Rotational vibration (RV) sensors help maintain performance in RAID and multi-drive systems (4TB or higher) Up to 10TB of capacity to store up to 10,000 hours of HD video (Approved Makes: Seagate/WD/Toshiba)
SITC of SWITCH PORTS: 16-Port 10/100/1000 + 2 x 1GE copper/SFP combo. Fixed-configuration 1RU x 1/2, half-rack width chassis, 16 x RJ45 10/100/1000 BaseT PoE+ ports 2 x SFP/RJ45 combo ports 2 x SFP ports, 1 x USB port (type A, USB 2.0), 1 x Console port (RS232 RJ45)IEEE 1588v2 capable ports 12, MACsec capable ports 12 Switch capacity 24 Gb/s, PoE power budget 115W, Includes power cord & manuals/software access cards, Includes RJ45 to DB9 adaptor Operating temperature: -10°C to 60°C (14°F to 140°F) Storage temperature -40°C
SITC OF Video Management Software equips users with live video from the camera feed, access control, video intercom, alarms, and data storage. Support upto 120 Camera Streaming. Abundant Modules – Video, access control, attendance, intercom, alarm, E-map, and more. Friendly User Experience and Visual Design – Lightweight, flat UI, and component-based design. Multiple-Languages – 33 languages, including English, Simplified Chinese, Arabic, etc.
SITC OF Server for Video Management Software Form Factor: 1U rack, Processor: 1x Intel® Xeon® processor E-2300 or 1x Intel® Pentium® processor GPU Support: NVIDIA Quadro T1000 PCIe Active GPU, Memory: Up to 128GB in 4x DIMM slots, Drive Bays: Up to 10x 2.5 inch hot-swap SATA/SAS drives or 4x 3.5-inch hot-swap SATA/SAS drives Expansion Slots: Up to 2x PCIe Gen4 x8 slots
SITC OF 43” Professional display rated for 16/7 operation with essential professional functions Screen Size 43, Brightness (cd/m²) 350, Contrast Ratio 1200:1, Dynamic Contrast, Ratio 400,000:1, Response Time (ms) 8.0, Display Resolution, (H x V, pixels) 3840 x 2160, HDR (High Dynamic Range) compatibility yes (HDR10, HLG)
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed PVC conduit as required.
Supply , Installation , Testing and Commissioning of 12U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts. Makes: Poweride/MTS/Rittal/APC/APW
SITC of 6 U network Rack
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Supply , Installation , Testing and Commissioning of CAT6 information outlet (I/O) for Data, Voice, Camera & Wi-Fi at user end. Makes: Belden/Siemon/Panduit/Leviton
Supply , Installation , Testing and Commissioning of loaded 24 port CAT6 jack panel for CAT6 cable termination at rack end.Makes: Belden/Siemon/Panduit/Leviton
Supply , Installation , Testing and Commissioning of CAT6 patch cord 3 feet for rack side switch to jack panel connectivity. Makes: Belden/Siemon/Panduit/Leviton
Supply , Installation , Testing and Commissioning of CAT6 patch cord 7 feet for information outlet (I/O) to end user device connectivity.Makes: Belden/Siemon/Panduit/Leviton
Supply , Installation , Testing and Commissioning of 1, 2 and 4 port face plate white for I/O fixing at user side. Makes: Belden/Siemon/Panduit/Leviton
Supply , Installation , Testing and Commissioning of 22 U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts.Makes: Netrack/MTS/Rittal/APC/APW
Supply , Installation , Testing and Commissioning of 9 U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts.Makes: Poweride/MTS/Rittal/APC/APW
Supply , Installation , Testing and Commissioning of Core Switch Port Density - 14 X 1/10G SFP Ports and 12 X 1/10G Base T 2 x 40/100 G QSFP28 Ports. Power Supply - Redundant Hot Swappable Power Supply - AC/DC, Virtual Chassis/ Stacking Option - Upto 6 Switches or more, RAM - 8 GB or better, Flash and Buffer - 32GB or better and 32MB Packet Buffer Switching Capacity and forwarding Rate, 900 Gbps or better and 650 Mpps or better , Latency & MTBF Latency: <650 ns MTBF: 384,636 h,MAC Address 64K, Routes IPv4 - 12k or better, IPv6 - 12k or better. Support for Egress rate limiting, Eight egress queues per port, IEEE 802.1Q, 802.3x, DiffServ, Jumbo frame. Protocol Support - IGMP Snooping V1, V2, V3, MLD, PIM-SM/PIM-SSM/PIM-DM/PIM-Bidirectional, DVMRP,RIPv1v2,RIPing ,OSPFv3, RIP, BGPv4, MP-BGP,GRE, IS-IS, ITU-T G.8032, IEEE 802.1s, IEEE 802.3ad/802.1AX Link Aggregation Control Protocol (LACP), Ipv4/Ipv6, DHCP Option 82, BPDU, STP Root Guard, SIP detection, SPB-M or MPLS, IEEE 802.1ae, MIB, NTP,Built-in CPU protection against malicious attacks,The Switch Should have 1+N redundant supervisor manager in Virtual chassis with In-Service Software Upgrade (ISSU), VXLAN, ARP Poisioning detection, Policy based routing (PBR),SDN support through Restful API and openflow 1.3.1, Management SNMP V1,V2,V3, Web GUI, CLI, USB or equivalent memory card, IPv6 management feature on open standards, IEEE802.1ag, TDM or equivalent standards
Security Should support Access Control Lists (ACLs), DHCP snooping, IEEE802.1x based port authentication, RADIUS/ TACACS+, SSL, SSH, port mirroring,NTP, IEEE 1588, AES, Syslog, MD5, LLDP-MED, BPDU Blocking, BFD, Unified management, control and fabric-mesh virtual chassis technology, Autosensing IEEE 802.1X multi- client, multi-VLAN support for bridging and SPBM/VXLAN services,MAC-based authentication for non-IEEE 802.1X hosts, MAC address lockdown, Prevention from ARP attacks Resiliency IEEE802.1q, IEEE802.1d, IEEE802.1s, IEEE802.1w, ITU-T G.8032 ring resilience/ring protection, VRRPv2, Operating Temperature and Humditiy Temperature: 0 to 45Deg Humidity: 5% to 95% (non-condensing) Safety Certifications CE, EN 55022, RoHS, US UL 60950, CSA22.2 , FIPS 140-2, EAL2 & NCPP Certified , EN 60825-1/2 Laser SFP , SFP should be of same make as switch. Vendor to be present in Gartner Magic Quadrant. The Switch shall work with on-premise and cloud based NMS without change in hardware/software/OS Image. The Switch should be EAL2/NDPP certified Cisco/Juniper / Alcatel-Lucent
Supply , Installation , Testing and Commissioning of Access switch Port Density 24 X 1G RJ-45 Ports 2 x 1G/10G SFP+ Ports and 2 x 1G SFP/Base-T Combo Ports Power Supply Internal Power Supply Virtual Chassis/ Stacking Option Upto 4 Switches or more RAM 1 GB or better Flash 1 GB or better Switching Capacity and forwarding Rate 92 Gbps or better and 68 Mpps or better Latency & MTBF Latency: < 4 µs MTBF: 2595 k hours Layer 2 Features Mac Address:16K or more VLAN: 4K or more System Policies: 1.5K or more Max Jumbo Frame: 9216 bytes Multicast Group: up to 1000 Quality of Service Auto QoS for switch management traffic,Policy-based QoS, Traffic Prioritization, Priority Queues: Eight hardware-based queues per port, SPQ, WRR
Protocol Support Static Routing, MSTP, RSTP, PVST+,IPv6 Tunneling, LACP, LAG, IGMPv3, DHCP, DHCP82,DHCP Relay for IPv4/IPv6,Multiple microcode image support with fallback recovery, ARP,SDN support through Restful API and openflow 1.3.1 Management Loopback IP address support for management per service, Policy- and port-based mirroring, Remote port mirroring, sFlow v5 and Remote Monitoring (RMON), Unidirectional Link Detection (UDLD),Digital Diagnostic Monitoring (DDM), LLDP-MED, NTP,MVRP, SNMP, sflow or equivalent Security Dynamic change of authentication (CoA),MAC-based authentication for non-IEEE 802.1X hosts, MAC address lockdown, Prevention from ARP attacks, Web based Authentication, Autosensing IEEE 802.1X multi-client, multi-VLAN support,RFC 1321 MD5, RFC 2284 PPP EAP,RFC 1826/1827/4303/4305 Encapsulating Payload (ESP) and crypto algorithms, RFC 2104 HMAC Message Authentication, Built-in CPU protection against malicious attacks Resiliency Unified management, control and virtual chassis technology, Virtual Chassis 1+N redundant supervisor manager, Virtual Chassis In-Service Software Upgrade (ISSU),Smart continuous switching technology, IEEE 802.3ad/802.1AX Link Aggregation Cisco/Juniper / Alcatel-Lucent
SITC of 24 Port POE Network Switch Port Density - 24 X 1G RJ-45 PoE+ Ports with 380W power budget, 2 x 1G/10G SFP+ Ports and 2 x 1G SFP/Base-T Combo Ports upgradable to 2 x 10G SFP+ Ports Power Supply - Internal Power Supply, Virtual Chassis/ Stacking Option- Upto 4 Switches or more RAM - 1 GB or better, Flash - 1 GB or better Switching Capacity and forwarding Rate - 128 Gbps or better and 190 Mpps or better Latency & MTBF - Latency: < 4 µs MTBF: 1447 k hours Layer 2 Features - Mac Address:16K or more VLAN: 4K or more, System Policies: 1.5K or more Max Jumbo Frame: 9216 bytes, Multicast Group: up to 1000 Quality of Service - Auto QoS for switch management traffic,Policy-based QoS, Traffic Prioritization, Priority Queues: Eight hardware-based- queues per port, SPQ, WRR Protocol Support - Static Routing, MSTP, RSTP, PVST+,IPv6 Tunneling, LACP, LAG, IGMPv3, DHCP, DHCP82,DHCP Relay for IPv4/IPv6,Multiple microcode image support with fallback recovery, ARP,SDN support through Restful API and openflow 1.3.1, Management - Loopback IP address support for management per service, Policy- and port-based mirroring, Remote port mirroring, sFlow v5 and Remote Monitoring (RMON), Unidirectional Link Detection (UDLD),Digital Diagnostic Monitoring (DDM), LLDP-MED, NTP,MVRP, SNMP, sflow or equivalent
Security - Dynamic change of authentication (CoA),MAC-based authentication for non-IEEE 802.1X hosts, MAC address lockdown, Prevention from ARP attacks, Web based Authentication, Autosensing IEEE 802.1X multi-client, multi-VLAN support,RFC 1321 MD5, RFC 2284 PPP EAP,RFC 1826/1827/4303/4305 Encapsulating Payload (ESP) and crypto algorithms, RFC 2104 HMAC Message Authentication, Built-in CPU protection against malicious attacks Resiliency - Unified management, control and virtual chassis technology, Virtual Chassis 1+N redundant supervisor manager, Virtual Chassis In-Service Software Upgrade (ISSU),Smart continuous switching technology, IEEE 802.3ad/802.1AX Link Aggregation Control Protocol (LACP) and static LAG groups across modules Operating Temperature and Humditiy - Temperature: 0 to 45Deg Humidity: 5% to 95% (non-condensing) Safety Certifications - CE, EN 55022, RoHS, WEEE US UL 60950, CSA22.2, FIPS 140-2, EN 60825-1/2 Laser, IEC 62368-1 SFP - SFP should be of same make as switch. Vendor to be present in Gartner Magic Quadrant. The Switch shall work with on-premise and cloud based NMS without change in hardware/software/OS Image. Cisco/Juniper / Alcatel-Lucent
SITC of WIFI Access Point Proposed solution will be Controller less/HW Controller based/SW Controller based but all the Access Points managed centralized . The WLAN solution shall propose an indoor 802.11ax Wifi 6 MU-MIMO indoor dual radio AP Access Point (2.4, 5G) AP to support 2x2:2 on 5 Ghz and 2X2:2 on 2.4 Ghz. Access Point shall offer up to 1200 Mbps throughput on the 5Ghz band (low and high bands) and up to 573 Mbps throughput on the 2.4GHz band. 2 x 10/100/1000Base-T autosensing (RJ-45) port . Both ports should support 802.3at PoE,1x USB 2.0 Type C AP should support ACL, wIPS/wIDS and DPI application, 802.11i, 802.1x Access Point shall propose a Factory reset button. Access Point shall support up to 16 SSIDs (8 per radio) with 512 Clients and should support BLE 5.1/Zigbee Integrated. Single AP can act in dual mode (WLC/Client Serving) with controller to support 256 Access Points in single cluster. Distributed Radio Management, Radio Dynamic Adjustment (RDA), Transmit Power Control @ 18 dBM(TPC), DFS, VHT20,40,80 It should support Advanced Cellular Coexistence (ACC) i.e Minimizes interference from 3G/4G cellular networks, distributed antenna systems, and commercial small cell/femtocell equipment L2 Roaming 802.11r Roaming, 802.11K, 802.11v
Operating temperature must be 0°C to 45°C Humidity must be 10% to 90% non-condensing. WFA, UL2043 Plenum rating, EMI,RoHS, REACH, WEEE
Supplying and drawing 2 pair, 0.5 sqmm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed PVC conduit as required.
Supplying and drawing 4 pair, 0.5 sqmm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed PVC conduit as required.
Supply, installation, testing & commissioning of termination box for 50 pair EPABX system complete as required
SITC of Communication appliance for Voice,configured for:- 01 PRI- 08 Trunk- 40 Digital- 150 Analog Extensions Internal CLI on Digital Phones and Analog CLI Phones Alcatel-Lucent/Matrix/Cisco
SITC of Ananlog Phone Display type 1 line-Dot-matrix + 1 line 7-segments+ 1 line icons alphanumeric displayDate and time displayed in standby mode Call duration display Number of ringtones 1Ringtones volume levels 3 (high / low / off Handsfree function Handsfree volume control 3, Direct access memories 82-touch memories 10,Caller Identification type I & IIIncoming call log, Mute key Wall-mountable, Dialing type Tone / Pulse Protocol FSK & DTMF, Removable line connector cord RJ11/RJ11, Power supply No battery required Alcatel-Lucent/Matrix/Cisco
SITC of Console Phone Optimised access to all ALE communications features Touch screen or large display with LED buttons 3D Symphonic HD super wideband sound Cylindrical sound bar with 3D diffusion and up to 3 microphones Elegant metal and textile casing with 4 interchangeable colours Extensive connectivity: USB, WLAN, Bluetooth, IP, hybrid digital/IP Secure remote working: VPN, SRTP Accessories include: Alphabetic keypad, wireless handset, WLAN and Bluetooth module, colour display key module Centralised management and deployment from the cloud
Supplying, installing, testing and commissioning of the following as per specification complete with junction box, as and where required.without JB Analogue addressable Photo Electric type Smoke Detector with mounting base, address switch complete as required. Make - Agni/Bosch/Siemens
Analogue addressable rate of rise cum fixed temperature thermistor type heat detector with mounting base, address switch complete as required. Make - Agni/Bosch/Siemens
Addressable type Manual Call Point complete as required. Make - Agni/Bosch/Siemens
Addressable Hooter cum strobe complete as required. Make - Agni/Bosch/Siemens
Addressable strobe complete as required. Make - Agni/Bosch/Siemens
Duct casting unit with casing of fabricated aluminium/poly carbonate and hinged inspection cover, 1 No. inlet of proper length & 1 no. outlet tube & with 1 no. analogue addressable photoelectric type Smoke detector with mounting base, address switch complete as required. Make - Agni/Bosch/Siemens
Analogue addressable Fault Isolators for isolating shorted, de-wired and loose circuits between two successive Fault isolators with automatic resetting arrangement. (max. 20 devices for one fault isolators). Make - Agni/Bosch/Siemens
Analogue addressable, automatic commandable Control Switches for switching on/off various ventilation fans, pressurisation fans, zones of speakers etc. and other Fire operation related devices and complete as required. Make - Agni/Bosch/Siemens
Addressable Input Card/monitor module for connecting to Flow Switch etc. Make - Agni/Bosch/Siemens
Response indicator consisting of 16 gauge MS box with 75 x 75 x 6 thick cross brushed MS face plate. Make - Agni/Bosch/Siemens
Zone address module to connect conventional zones with the addressable panel. Make - Agni/Bosch/Siemens
Each loop of fire alarm panel shall have 10 to 15% spare addressable units. At all panels global access to be provided. Information of all the panel shall be accessible from any of panels through networking. All panels shall be upgradable to minimum 25% more loops. Other requirements are given in the specifications. The no. of loops may be changed based on the loop capacity of the panel. loop card.
Providing, installing, testing and commissioning of Zero Loop Repeater Panel for Fire Alarm System with piezo sounder, LCD alpha numeric character display with accept/reset buttons for alarm address of any sensor/field device. The Repeater Panel shall provide field device address as required. The Repeater Panel shall be active & all the setting for fire alarm system can be configured with panel.
Wall mounted speaker with three tap changers in acoustically treated box with speaker and line matching transformer (2W max).(For car park & double height areas)
Ceiling mounted baffle speaker with three tap changers (2W).
Portable UL listed fire phone handsets in a suitable enclosure.
Addressable fire phone jack plates with control/monitor module.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specification as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module conversion efficiency shall not be less than 16.5% PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Connections and interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kv grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories complete job etc. as required. (Including 5.36% GST) Make-Tata Power/Adani/Vikram solar/Waaree
SITC of 30 KVA, 3 Ph, IGBT Based Inverter & Rectifier Both Side True Online Double Conversion UPS and M.S Powder Coated Rack & Interconnecting cable with inbuilt Phase Sequence Correction. For 30 Minutes Battery Backup using 12 Volt 65 Ah, SMF Batteries (Total 24960 VAH for 30 minutes Battery Backup). Make:- Numeric/APC/Vertiv.
Providing and fixing following capacity double pole / TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
P/F following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty complete with all accessories including connections, earthing the body etc as reqd.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Fixing for laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Providing chemical/ mineral maintenance free aerthing system comprising of copper earth electrode 3 metre length and 17.2 mm outer dia along with 25 Kg earth electrode conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth inspection pit etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq.mm FR PVC insulated copper conductor cable in recessed PVC conduit with modular switch modular plate suitable GI box earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
Group B
Wiring for power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No.4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as required
Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required.
Meter
Meter
Meter
Meter
Meter
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing modular type 3 pin 5/6 amps socket outlet & 6A modular switch connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing modular 6 pin 15/16 amp socket outlet &15/16 amp modular switch including connection etc as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Meter
Supplying and fixing modular T.V antenna socket on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Supplying and drawing co-axial T.V cable RJ-6 grade , 0.7mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed PVC concuit as required.
Supplying and fixing modular Telephone socket outlet on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Supplying and drawing 2 pair 0.5 sq mm. FR PVC insulated annealed copper conductor unarmoured telephone cable in the existing surface / recessed PVC concuit as required.
Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular fitting in recess etc. as required. (For TV & Telephone out let)
1 or 2 Module (75mmX75mm)
Supplying & fixing of the 10 pair Krone Type Sub distribution frame box including connection testing etc as required.
Supplying and installation of 10 pair 0.5 sq mm.ATC unarmoured PVC insulated copper conductor telephone cable through existing PVC conduit including connection, testing etc. as required.
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way ( 4 + 12 ), double door, horizontal type
6 way ( 4 + 18 ), Double door, horizontal type
Supplying and fixing of following rating C series MCB suitable for inductive and other loads of following poles in the existing MCB DB complete witth connections ,testing and commissioning etc. as required .
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley internal wiring, earth terminals, Bus bar Chamber, Insulator and complete in all respect etc and panel manufacturers must be approved by CPRI. (But without RYB inicator , ammeter, voltmeter, inter-connection copper conductor cable / solid copper strip, switchgears etc.
Supplying and fixing of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc.as required.
100 A, 30 KA, FPMCCB
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
50 mm X 5 mm copper strip (2.30 Kg/mtr)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required.
Providing and fixing MV danger notice plate of 200mm x 150 mm made of mild steel at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side etc as required.
Earthing with G.I. plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with salt and charcoal / coke as required.
Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate / switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box along with modular base and cover plate for modular switches in recess etc as required.
Supply and Installation of following sweep / sizes metallic biade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc. as required.
Supply and fixing of following sweep/ sizes PVC/ABS square body Exhaust Fan with automatic openable louvre shutter in existing opening including making connection, testing etc as required.
Supplying and fixing 2 pin 5 Amp ceiling rose on the existing junction box/ PVC box including connection etc as required.
Supplying and fixing batten / angle holder including connections with 1.5 sq.mm FR PVC insulated, copper conductor single core cable etc. as required.
9/10 watt LED lamp
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficancy 100 Im/w in pressure die-cast aluminium housing and intergrated electronic driveretc. Directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc. as required.
Supplying and fixing Surface mounted 10/12 watt LED type Bulk-head fitting comprising of pressure die cast housing with acrylic diffuser (IP65) and complete with integrated electronic driver etc directly on wall/ceiling ncluding connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc. as required.
Supplying fitting fixing of call bell suitable for DC/AC single phase 230 volts,complete etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
meter
Upto 35 sq. mm
Upto 35 sq. mm (Clamped with 1 mm thick saddle)
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq.mm FR PVC insulated copper conductor cable in recessed PVC conduit with modular switch modular plate suitable GI box earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
Group A
Wiring for power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No.4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as required
Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required.
Meter
Meter
Meter
Meter
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing modular type 3 pin 5/6 amps socket outlet & 6A modular switch connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing modular 6 pin 15/16 amp socket outlet &15/16 amp modular switch including connection etc as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
meter
Supplying and fixing modular T.V antenna socket on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Supplying and drawing co-axial T.V cable RJ-6 grade , 0.7mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed PVC concuit as required.
Supplying and fixing modular Telephone socket outlet on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Supplying and drawing 2 pair 0.5 sq mm. FR PVC insulated annealed copper conductor unarmoured telephone cable in the existing surface / recessed PVC concuit as required.
Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular fitting in recess etc. as required. (For TV & Telephone out let)
1 or 2 Module (75mmX75mm)
Supplying & fixing of the 10 pair Krone Type Sub distribution frame box including connection testing etc as required.
Supplying and installation of 10 pair 0.5 sq mm.ATC unarmoured PVC insulated copper conductor telephone cable through existing PVC conduit including connection, testing etc. as required.
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing of following rating C series MCB suitable for inductive and other loads of following poles in the existing MCB DB complete witth connections ,testing and commissioning etc. as required .
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley internal wiring, earth terminals, Bus bar Chamber, Insulator and complete in all respect etc and panel manufacturers must be approved by CPRI. (But without RYB inicator , ammeter, voltmeter, inter-connection copper conductor cable / solid copper strip, switchgears etc.
Supplying and fixing of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc.as required.
100 A, 30 KA, FPMCCB
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
50 mm X 5 mm copper strip (2.30 Kg/mtr)
Suppy and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required.
Providing and fixing MV danger notice plate of 200mm x 150 mm made of mild steel at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side etc as required.
Earthing with G.I. plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with salt and charcoal / coke as required.
Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate / switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box along with modular base and cover plate for modular switches in recess etc as required.
Supply and Installation of following sweep / sizes metallic biade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc. as required.
Supply and fixing of following sweep/ sizes PVC/ABS square body Exhaust Fan with automatic openable louvre shutter in existing opening including making connection, testing etc as required.
Supplying and fixing 2 pin 5 Amp ceiling rose on the existing junction box/ PVC box including connection etc as required.
Supplying and fixing batten / angle holder including connections with 1.5 sq.mm FR PVC insulated, copper conductor single core cable etc. as required.
Supplying and fixing following types lamp in existing electrical fitting/ fixture etc as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficancy 100 Im/w in pressure die-cast aluminium housing and intergrated electronic driveretc. Directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc. as required.
Supplying and fixing Surface mounted 10/12 watt LED type Bulk-head fitting comprising of pressure die cast housing with acrylic diffuser (IP65) and complete with integrated electronic driver etc directly on wall/ceiling ncluding connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc. as required.
Supplying fitting fixing of call bell suitable for DC/AC single phase 230 volts,complete etc as required.
Supply of following sizes and core of PVC/XLPE insulated PVC sheathed heavy duty , aluminium conductor armoured under ground cable of graded 1.1 KV for working voltage upto 1100 volts conforming to ISI .
Metre
Laying of one number insulated and PVC sheathed power cable of 1.1 KV grade of following size direct in ground including excavations, sand cushioning protective covering and refilling the trench etc. as required.
Metre
Laying and fixing of one number PVC insulated and PVC sheathed aluminium conductor cable of1.1 KV grade of following size on surface etc. as required.
Above 35 sq. mm and upto 95 sq. mm (Clamped with 25 x 3 mm MS flat clamp)
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq.mm FR PVC insulated copper conductor cable in recessed PVC conduit with modular switch modular plate suitable GI box earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
Group A
Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required.
Meter
Meter
Meter
Meter
Wiring for power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No.4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing modular type 3 pin 5/6 amps socket outlet & 6A modular switch connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing modular 6 pin 15/16 amp socket outlet &15/16 amp modular switch including connection etc as required
Supplying and fixing modular T.V antenna socket on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Supplying and drawing co-axial T.V cable RJ-6 grade , 0.7mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed PVC concuit as required.
Supplying and fixing modular Telephone socket outlet on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Supplying and drawing 2 pair 0.5 sq mm. FR PVC insulated annealed copper conductor unarmoured telephone cable in the existing surface / recessed PVC concuit as required.
Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular fitting in recess etc. as required. (For TV & Telephone out let)
Supplying Installing Testing and commissioning of 20 Pair distribution tag box all complete as per specification and direction of E/I
Supplying and installation of 10 pair 0.5 sq mm.ATC unarmoured PVC insulated copper conductor telephone cable through existing PVC conduit including connection, testing etc. as required.
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, Double door
14 way, Double door
Supplying and fixing of following rating C series MCB suitable for inductive and other loads of following poles in the existing MCB DB complete witth connections ,testing and commissioning etc. as required .
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6 A to 32 A, double pole
40 A to 63 A, double pole
Supplying and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley internal wiring, earth terminals, Bus bar Chamber, Insulator and complete in all respect etc and panel manufacturers must be approved by CPRI. (But without RYB inicator , ammeter, voltmeter, inter-connection copper conductor cable / solid copper strip, switchgears etc.
Supplying and fixing of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc.as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6 A to 32 A, double pole
40 A to 63 A, double pole
50 mm X 5 mm copper strip (2.30 Kg/mtr)
Suppy and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required.
Providing and fixing MV danger notice plate of 200mm x 150 mm made of mild steel at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side etc as required.
Earthing with G.I. plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with salt and charcoal / coke as required.
Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate / switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box along with modular base and cover plate for modular switches in recess etc as required.
Supply and Installation of following sweep / sizes metallic biade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc. as required.
Supply and fixing of following sweep/ sizes PVC/ABS square body Exhaust Fan with automatic openable louvre shutter in existing opening including making connection, testing etc as required.
Supplying and fixing 2 pin 5 Amp ceiling rose on the existing junction box/ PVC box including connection etc as required.
Supplying and fixing batten / angle holder including connections with 1.5 sq.mm FR PVC insulated, copper conductor single core cable etc. as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing Surface mounted 10/12 watt LED type Bulk-head fitting comprising of pressure die cast housing with acrylic diffuser (IP65) and complete with integrated electronic driver etc directly on wall/ceiling ncluding connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc. as required.
Supplying fitting fixing of call bell suitable for DC/AC single phase 230 volts,complete etc as required.
70 sq. mm, 3.5 core
Metre
Metre
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq.mm FR PVC insulated copper conductor cable in recessed PVC conduit with modular switch modular plate suitable GI box earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
Point
Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required.
Meter
Meter
Meter
Meter
Wiring for power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No.4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing modular type 3 pin 5/6 amps socket outlet & 6A modular switch connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing modular 6 pin 15/16 amp socket outlet &15/16 amp modular switch including connection etc as required
Supplying and fixing modular T.V antenna socket on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Supplying and drawing co-axial T.V cable RJ-6 grade , 0.7mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed PVC concuit as required.
Supplying and fixing modular Telephone socket outlet on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Supplying and drawing 2 pair 0.5 sq mm. FR PVC insulated annealed copper conductor unarmoured telephone cable in the existing surface / recessed PVC concuit as required.
Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular fitting in recess etc. as required. (For TV & Telephone out let)
Supplying & fixing of the 10 pair Krone Type Sub distribution frame box including connection testing etc as required.
Supplying and installation of 10 pair 0.5 sq mm.ATC unarmoured PVC insulated copper conductor telephone cable through existing PVC conduit including connection, testing etc. as required.
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, Double door
12 way, Double door
Supplying and fixing of following rating C series MCB suitable for inductive and other loads of following poles in the existing MCB DB complete witth connections ,testing and commissioning etc. as required .
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6 A to 32 A, double pole
40 A to 63 A, double pole
Supplying and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley internal wiring, earth terminals, Bus bar Chamber, Insulator and complete in all respect etc and panel manufacturers must be approved by CPRI. (But without RYB inicator , ammeter, voltmeter, inter-connection copper conductor cable / solid copper strip, switchgears etc.
Supplying and fixing of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc.as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6 A to 32 A, double pole
40 A to 63 A, double pole
50 mm X 5 mm copper strip (2.30 Kg/mtr)
Suppy and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required.
Providing and fixing MV danger notice plate of 200mm x 150 mm made of mild steel at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side etc as required.
EARTHING
Earthing with G.I. plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with salt and charcoal / coke as required.
Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
SUPPLY & INSTALLATION OF FIXTURES
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate / switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box along with modular base and cover plate for modular switches in recess etc as required.
Supply and Installation of following sweep / sizes metallic biade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc. as required.
Supply and fixing of following sweep/ sizes PVC/ABS square body Exhaust Fan with automatic openable louvre shutter in existing opening including making connection, testing etc as required.
Supplying and fixing 2 pin 5 Amp ceiling rose on the existing junction box/ PVC box including connection etc as required.
Supplying and fixing batten / angle holder including connections with 1.5 sq.mm FR PVC insulated, copper conductor single core cable etc. as required.
Supplying and fixing following types lamp in existing electrical fitting/ fixture etc as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing Surface mounted 10/12 watt LED type Bulk-head fitting comprising of pressure die cast housing with acrylic diffuser (IP65) and complete with integrated electronic driver etc directly on wall/ceiling ncluding connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc. as required.
Supplying fitting fixing of call bell suitable for DC/AC single phase 230 volts,complete etc as required.
Metre
Metre
Metre
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq.mm FR PVC insulated copper conductor cable in recessed PVC conduit with modular switch modular plate suitable GI box earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
Point
Wiring for power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No.4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as required
Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required.
Meter
Meter
Meter
Meter
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing modular type 3 pin 5/6 amps socket outlet & 6A modular switch connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing modular 6 pin 15/16 amp socket outlet &15/16 amp modular switch including connection etc as required
Supplying and fixing modular T.V antenna socket on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Supplying and drawing co-axial T.V cable RJ-6 grade , 0.7mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed PVC concuit as required.
Supplying and fixing modular Telephone socket outlet on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Supplying and drawing 2 pair 0.5 sq mm. FR PVC insulated annealed copper conductor unarmoured telephone cable in the existing surface / recessed PVC concuit as required.
Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular fitting in recess etc. as required. (For TV & Telephone out let)
Supplying & fixing of the 10 pair Krone Type Sub distribution frame box including connection testing etc as required.
Supplying and installation of 10 pair 0.5 sq mm.ATC unarmoured PVC insulated copper conductor telephone cable through existing PVC conduit including connection, testing etc. as required.
MAIN PANEL & D.B.s
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, Double door
12 way, Double door
Supplying and fixing of following rating C series MCB suitable for inductive and other loads of following poles in the existing MCB DB complete witth connections ,testing and commissioning etc. as required .
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6 A to 32 A, double pole
40 A to 63 A, double pole
Supplying and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley internal wiring, earth terminals, Bus bar Chamber, Insulator and complete in all respect etc and panel manufacturers must be approved by CPRI. (But without RYB inicator , ammeter, voltmeter, inter-connection copper conductor cable / solid copper strip, switchgears etc.
Supplying and fixing of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc.as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6 A to 32 A, double pole
40 A to 63 A, double pole
50 mm X 5 mm copper strip (2.30 Kg/mtr)
Suppy and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required.
Providing and fixing MV danger notice plate of 200mm x 150 mm made of mild steel at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side etc as required.
EARTHING
Earthing with G.I. plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with salt and charcoal / coke as required.
Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
SUPPLY & INSTALLATION OF FIXTURES
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate / switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box along with modular base and cover plate for modular switches in recess etc as required.
Supply and Installation of following sweep / sizes metallic biade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc. as required.
Supply and fixing of following sweep/ sizes PVC/ABS square body Exhaust Fan with automatic openable louvre shutter in existing opening including making connection, testing etc as required.
Supplying and fixing 2 pin 5 Amp ceiling rose on the existing junction box/ PVC box including connection etc as required.
Supplying and fixing batten / angle holder including connections with 1.5 sq.mm FR PVC insulated, copper conductor single core cable etc. as required.
Supplying and fixing following types lamp in existing electrical fitting/ fixture etc as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing Surface mounted 10/12 watt LED type Bulk-head fitting comprising of pressure die cast housing with acrylic diffuser (IP65) and complete with integrated electronic driver etc directly on wall/ceiling ncluding connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc. as required.
Supplying fitting fixing of call bell suitable for DC/AC single phase 230 volts,complete etc as required.
Metre
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supply, Installation, testing & commissioning 200 KVA, 11 K V / 433 V, 50 Hz, 3 phase Delta / Star connected, copper wound ONAN Transformer with Dyn-11 vector group suitable for out-door, floor mounting. The transformer shall have OFF Load taps in steps of +/- 2.5 % and +/-5 %, complete with first fill of oil and shall conform to I S : 2026 - 2011 & IS : 1180 (Level-2) : 2014 (latest edition). H. T. & L. T. sides of the transformer shall be suitable for cable termination box / Busduct Termination box complete with cable end-boxes as follows: Make:-kotsons/Powerstar /kirloskar/crompton HT SIDE: 11 KV ,3C X120MM XLPE CABLE ,LT SIDE:,2 X 3.5 X185 Sq. mm. XLPE CABLE Transformer shall have provided with winding over temperature indication and trip devices.
Supply ,Installation, testing and commissioning of 2 Pole mounted DP providing I no 11kv,400A GOC in accordence with ie rules& local authority specifications and drawing and comprasing the following
meter
meter
Metre
pairs
Meter
Meter
Description of Work
Earth work in excavation over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m; disposal earth to be levelled and neatly dressed.
Earth work in excavation in foundation trenches or drains (not excoding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the exvavted soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Extra for every additional lift of 1.5 m or part thereof in
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth : consolidating each deposited layer by ramming and watering lead.
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Clearing jungle including uprooting or rank vegetation, grass, brush wood, trees and scaplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Beyond 40 cm girth up to and including 60 cm grith
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Turfing with Sods (Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the engineer including preparation of ground, fetching of rods and watering)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.
1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1.4.8 (1 Cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size)
1:3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1:3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by the manufacturers.
Centring and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc., for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Shelves (Cast in situ)
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Post and struts
Stairs, (excluding landings) except spiral staircases.
Vertical and Horizontal fins individually or forming box louvers band, facias ane eaves boards.
Wheather shade, Chajja, corbels etc., including edges.
Edges of slabs and breaks in floors and walls :
Metre
Extra for shuttering in circular work (20% of respective centring and shuttering items)
Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc, including cost of de-shutering and de centring at all levels over a height of 3.5 m, for every additional height of 1 meter of part thereof (plan area to be measured)
Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete.
TMT-500- 8mm dia .
TMT-500-10 mm dia.
TMT-500-12 mm dia
TMT-500-16 mm dia.
TMT-500-20 mm dia.
TMT-500-25 mm dia
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
Concrete of M-25 grade with minimum cement content of 330 kg/cum
Concrete of M-25 grade with minimum cement content of 350 kg/cum
Concrete of M-25 grade with minimum cement content of 330 kg/cum
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete
All work upto plinth level
All works above plinth level upto floor V level
Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.
Add or deduct for providing richer or leaner mixes respectively at all floor levels
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level
Brick work with fly ash bricks as per IS 12894 (2002) & IS 3495 in foundations and plinth in :
Half brick Masonary Cement mortar 1.:4 (1 cement: 4 coarse sand ) - 125 mm th Brick work
Extra tor Brick work in superstructure above plinth level upto floor V cum
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S.pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin-charge
12 mm thick prelaminated (with decorative lamination on one side and balancing lamination on other side) particle board Grade -1 medium density flat pressed, three layer and graded (FPT-1) conforming to IS :3087 bonded with BWP type synthetic resin adhesive as per IS :848 and prelamination conforming to IS :12823 Grade-1 Type II
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type,core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
Providing and fixing aluminium sliding door bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ), transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (Over all area of door shutter to be measured).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:
Metre
Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C.doors) using synthetic rubber based adhesive.
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed onthe body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Metre
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - incharge. (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing non load bearing fixed frame for fire resistant glazed Partition for 120 min Fire Rating, made out to a profile of dimension 60mm x 70 mm of 1.6 mm thick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for 120 min of both integrity & radiation control (EW120) & minimum 15 min of insulation (El15). The profile has to be fixed to the supporting construction by means of anchor fasteners of size M10 x 80, every 150 mm from the edges and every 500 mm (approx) c/c. Linear meaurement of frame shall be measured for payment. The frame shall be filled with mineral wool insulation of density min 96kg/m³. and finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer -incharge.
Providing and fixing pressed steel door frame confirming IS code 351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-Charge.
Metre
Metre
Providing and fixing ISI marked steel glazed door, windows and ventilators of standard rolled steel section & joints mitered and welded with 15x3 mm lugs, 10cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawls plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with glazing clips and special metal sash putty of approved make complete including applying a priming coat of approved steel primer, but excluding the cost of steel beading and other fittings except necessary hinges or pivots as required.
Providing and fixing bright finished brass peg stays to steel ventilators with necessary welding and machine screws etc. complete.
Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete.
Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides.
Steel work welded in built up section/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Extra for providing and fixing steel beading of approved shape and section with screws instead of glaxing clips and met. Sash putty in steel doors, windows, Ventilators and comosite units.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-iron 40x40x6 mm with 40 mm dia steel pulleys complete with bots. Nuts locking arrangement stoppers handles including applying a priming coat of approved steel primer
Providing and fixing hand rail welding etc.to steel ladder ralling & staricases railing including
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / neling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)
"Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as pr IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the erimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.
Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete.
Providing flyash one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I.
Providing flyash one Brick on edge soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specifiction and direction of E/I.
Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Motar 1:3 (1cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) /1:4 (1 cement : 4 coarse sand)
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with:
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Area of slab upto 0.50 sqm
Area of slab over 0.50 sqm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of
Extra for Kota stone / sand stone in treads of steps and risers using single up to 1.05 metre.length
Extra for pre finished nosing in treads of steps of Kota stone / sand stone slab.
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622, of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of neat cement
12 mm cement plaster of mix
1:3(1 Cement :3 coarse sand)
1:4(1 Cement :4 coarse sand)
1:6 (1 cement : 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix.
15mm cement plaster 1:3 (1cement : 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall
6 mm cement plaster to ceiling of mix.
1:3(1 Cement :3 coarse sand)
1:4 (1 cement : 4 coarse sand)
White washing with whiting to give an even shade.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
Distempering with 1st quality washable distemper (ready made ) of approved manufacturer and of required shade and colour complete. As per manufacture's specifications.
Applying priming coat:
With ready mixed pink or grey primer of approved brand and manufacture on woodwork (hard and soft wood)
With ready mixed red oxide zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works
Finishing walls with Acrylic Smooth exterior paint of required shade :
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
Painting with synthetic enamel paint of approved brand and manufacture to give an even shed.
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Forming groove of uniform size from 12 x 12 mm and upto 25 x 15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
Neat Cement punning
Applying one coat of cement primer of approved brand and manufacture on wall surface :
Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give and even shade
Stone work (machine cut edge) for wall lining etc. (veneer work) over 12 mm thick bed of cement lime mortar 1:1:6 (1cement : 1 lime putty : 6 fine sand) including pointing in white cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid for seperately)
Providing and fixing gun metal cramps of required shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 ( 1cement : 2 fine sand) including making the necessary chases.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part there of
Rough cast plaster with a mixture of sand and gravel or crushed stone from 2.36 to 12.5 mm nominal size dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:5 (1 cement:5coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement:3 corse sand) mixed with 10% finely grounded hydrated lime by volume of cement :
Extra for plastering :
Finishing walls with Premium Acrylic smooth exterior paint with silicone additives of required shade.
Finishing walls with textured exterior of required shade :
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed protions of W.C. kitchen and the like consisting of :
Grading roof for water proofing treatment with
Providing and laying integral cement based water proofing treatment including repatation of surface as required for treatment of roofs, balconies , terraces etc, consisting of following operations. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water -proofing compound cleaning the surface before treatment, (b) Laying cement concrete using broken bricks / brick bats 25 mm to 100 mm size with 50 % of cement mortar 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mmthick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water froofing compound onforming to IS 2545 to reuired slope and treating similary the adjoining walls upto 300 mm height including rounding of junctions, or walls ad slabs. (c) After two days of proper curing applying a secoung coat of cement slurry admixed with proprietary waterproofing compound conforming to IS :
Providing and Laying APP (Atactic Polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre /sqm by the same membrane manufacture of density at 250 C, 0.87-0.89 kg / litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The Vital physical and chemical parameters of the membrane shall be as under : Joint strength in logitudinal and transverse direction at 230 C as 650/ 450N / 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 1500C. Cold flexibility shall be upto -20C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100%polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing flooring under portico consisting of 100mm PCC ( 1:2:4 ) over brick on edge soling over 100 mm sand filling.
Providing plain cement concrete in (1:2:4) including making grooves laid in pattern of tiles 300 x 300 mm avg. thickness 40 mm on sloped roof as per drawings all complete.
Making khurras 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1cement:3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
Providng and filling in position, blown bitumen in expansion joints.
100m (Length) x1cm (Wide)x 1cm (Depth)
Providng and fixing sheet covering over expansion joints with iron screws as per design to match the colour/shade of wall treatment,
Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termites' treatrnent (including the cost of chemical emulsion)
Along external wall where the apron is not provided using chemical imulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete.
Metre
Along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.
Metre
Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I.
Providing and fixing Wire mesh
Marble work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work) in c ement mortar 1:3 (1 cement :3 coarse sand) including pointing with white coment mortar 1:2(1 shite cement:2 marble dust) with an admixture of pigment to match the marble shade:(To be secured to the backing by means of cramps, which shall be paid for separately)
Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections.
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia 0.63 mm all complete.
Signage
Supplying and fixing C.I. cover without frame for manholes :
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing in position 25mm diameter mosquito proof coupling of approved municipal design
Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of / and manure before and after flooring trench with water (excluding cost of imported earth, sludge or manure)
Supplying and stacking of good earth at site including royalty but excluding carriage (earth measured in stacks will be reduced by 20 % for payment)
Supplying and stacking at site dump manure from approved source, excluding carriage (manure measured in stacks will be reduced by 8% for payment)
Mixing earth and sludge or manure in proportion specified or directed.
Spreading of sludge, dump manutre or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately)
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking clods, rought dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.
Grassing with 'Doob' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free form weeds and fit for moving including supplying good earth if needed.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20 % 1 part of stacked volume of manure after reduction by 8 % ) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure sludge or extra good earth if needed to be paid for separately)
Holes 1.2 m dia. And 1.2 m deep.
Holes 60 cm dia. And 60 cm deep.
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8 :1 (8 parts of stacked volume of earth after reduction by 8% ) flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)
Plantation of trees & Shrubs/ creeps.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge:
Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5 mm), including making drainage opening wherever required etc. complete as per direction of Engineer-in-charge. (Length of finished kerb edging shall be measured for payment). (Old kerb stones shall be supplied by the department free of cost)
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-incharge.
Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in theproportion of 1:2 (1 cement : 2 fine sand) including testing of jointsetc. complete :300 mm dia. R.C.C. Pipe
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacture's specifications including appropriate priming coat, preparation of surface, etc, complete.
per 1000 nos
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including, cutting and making good the walls etc. (internal work)
Metre
Metre
Metre
Metre
Metre
Metre
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
Metre
Metre
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc . (external work)
Providing and fixing brass bib cock of approved quality.
Providing and fixing brass stop cock of approved quality (screwed end).
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end).
Providing and fixing gun metal non-return valve of approved quality (screwed end)
50mm nominal bore
32mm nominal bore
32mm nominal bore
Horizontal
Providing and fixing P V C connection pipe with brass unions.
Providing and fixing C.P. brass shower rose 15 or 20 mm inlet.
Constructing masonry Chamber 30 x 30 x 50 cm inside, in brick work in cement mortar 1:4( 1 cement: 4 coarse sand) for stop cock, with C.I surface box 100 x 100 x 75 mm(inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation, foundation concrete 1:5:10( 1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:
Constructing masonry Chamber 60 x 60 x 75 cm inside, in brick work in cement mortar 1:4(1 cement: 4 coarse sand) for sluice valve, with C.I surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necesary excavation, foundation concrete 1:5:10( 1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3( 1 cement: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:nt complete as per standard design.
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
Metre
Metre
Metre
Metre
Metre
Metre
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :
meter
meter
meter
Providing & filling sand of grading zone V or coarser grade all-around G.I. pipes in external work.
Metre
Metre
Metre
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc.complete (new work)
Providing and fixing C.P. brass,bib cock of approved quality conforming to IS : 8931
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS stamdards and weighing notless than 810 gms.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS stamdards and weighing notless than 690 gms.
Providing and fixing C.P brass stop cock (concealed) of standard design and of approved mark conforming to IS:8931
Providing and fixing C.P brass angle valve for basin mixer and gyser points of approved quality conforming to IS: 8931
Providing and fixing PTMT Soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Cutting holes up to 30 x 30 cm in walls including making good the same:
Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including finishing complete so as to make it leak proof.
Making holes up to 20 x 20 cm and embedding pipes upto 150 mm in diametre in masonary and filling with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) including dispopsal of malba.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
Provoding and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug , 40 mm C.P brass waste complete, including painting the fittings and brackets, cutting and making good the walls whereever required.
Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5 mm glass shelf with edges round off,supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
Providing and fixing soil, waste and vent pipes
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),including cost of cutting holes and making good the walls etc. :
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick bolts and nutts complete
Providing and fixing plain bend of required degree
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete.
Providing and fixing terminal guard
Providing lead caulked joints to sand cast iron/ centrifugally cast (spun) iron pipes and fittings of diameter
Providing and fixing trap of self cleaning design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.
Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :
metre
Providing and fixing on wall face unplasticised PVC (working pressure 4 kg per sqcm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
Metre
Providing and fixing on wall face unplasticised PVC moulded fittings / accessories for unplasticised-PVC rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
Single pushfit Coupler:
Single tee with door
Shoe plain
Providing and fixing unplasticised-PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S screws or required length including cutting brick work and fixing on cement mortar (1:4) 1 cement:4 coarse sand and making good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :
Providing and fixing white vitreous china pedastal type water closet (European type W.C pan) with seat and lid, 10 litre low level white P.V.C flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions G.I. clamps, complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:
Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C.automatic flushing cistern, with fittings, standard size G.I. / PVCflush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required :
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone finished smooth.aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distances of 37mm fromwall face with concealed fittings arrangement of approved quality, and colour, weighing not less than 88 gms.
Cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement: 3 coarse sand : 6 graded stonea agregate 12.5mm nominal size) including necessry plaster and pointing in cement mortar 1:4 ( 1 cement: 4 coarse sand):
Metre
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
Metre
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes inlcuding bed concrete as per standard design.
Metre
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
Providing and laying non-pressure NP2 class (light duty) R.CC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2( 1 cement: 2 fine sand) including testing of joints etc. complete.
Metre
Metre
Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.
Constructing brick masonry manhole in cement mortar 1:4(1 cement: 4 coarse sand) with R.C.C top slab with 1:2:4 mix (1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand:8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3( 1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design:
Extra for depth for manholes Size 90 x 80 cm with common burnt clay F.P.S (non modular) bricks of class designation 7.5
Constructing brick masonry chamber for underground C.I inspection chamber and bends with bricks in cement mortar 1:4( 1 cement: 4 coarse sand) C.I cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg) R.C.C top slab ith 1:2:4 mix ( 1 cement: 2 coarse sand:4 graded stone aggregate 20mm nominal size) foundtion concrete 1:5:10( 1 cement: 5 fine sand:10 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
Extra for depth beyond 45 cm of brick masonry chambar For 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Providing 150mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron concrete (1: 4:8), over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l,
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
metre
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -in-charge.
metre
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
metre
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe,removable as per requirement, all complete for borewell of:
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia
Gravel packing in tubewell construction in accordance with IS:4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
S/F/F Submersible 1.5H.P pump
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking TGrid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The
Providing, fittings & fixing vertical venetian blinds (of vista, mac make) to window made with aluminium slate or approved thickness, colour quality with all accessories including adjuster, hardworks complete with all labour and materials in all floors.Design and colour to be approved first by Engineer-in-Charge.
Providing and fixing anodised aluminium work for doors, windows, ventilator? and partitions with extruded built up standard tubular and otner sections of approved make conforming to IS : 733 and IS : 1285,anodised trasparent or dyed to required shade according to IS : 1868,(Minimum anodic coating of grade AC 15), fixed with.rawl plugs and screws or with fixing clips , or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust fre straight, mitred and jointed mechanically wherever required including cleat angle,.Aluminium snap beading tor glazing/paneling, C.P. brass/stainless steel screws, all complete as per architecttural drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately.)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Providing & fixing of Aluminium Framed preliminated painted board complete wirth fixing of room no. / name plate / exit route in Hostel rooms & chambers of Institute block and hostel as per choice of client / E/I
Full height storage (size : 1200 L x 1975 H x 600 D) for Record room Making, supply and installation of Wooden Wardrob, 600mm deep, the sides, Top of B.W.P. lesard with 1.0 mm laminates finish. 12 mm thick B.W.P. Ply The front shutter with 19 mm thick B.W.P. Ply wood of century ply or equivalent with 1.0 mm thick. laminates movable roller, channel, recess knob Itallica Locks glass etc. including all fitting & fixture shall be complete in all respect. as per drawing and direction of E/I.
Storage Unit Low Height for Officer chamber (size :1050L x 430W x 750H) Supply , Fabrication and Installation of low height storage unit. The structure of made out of 18mm thick pre-laminated board (PLB). The shelves are made out of 18mm thick (PLB) , which are adjustable in height. The shutters are made out of 18 mm (PLB) openable and fitted by hinges, recessed handles, locking unit and levelers are considered, all complete as per drawing and directly of E/I.
Information Desk : (3775 x 750 x 900 h) Supplying and fixing Information Desk made of 25 mm thick prelaminated board top with PVC edge binding on wooden frame completes with shelves, key board and CPU Trolley, wire manager with all hardware. Internal wooden surface polished all complete per drawing and direction of E.I.
Interaction Countre : Size (4200 mm x 750 x 900 H) Supplying and fixing Interaction Countre made of 25 mm thick prelaminated board top with PVC edge binding on wooden frame completes with shelves, key board and CPU Trolley, wire manager with all hardware. Internal wooden surface polished all complete per drawing and direction of E.I.
Side table (size : 510 x 440 x 450mm) Supply,Fabrication & Installation of side table made of prelaminated board top matched with bed finish , with all necessary fixtures and fittings complete as per drawing and direction of E/I.
Canteen Table - (Size : 900 x 900) - Supply Fabrication and Installation of rectangular table of size (900 x 900 x 750 H) with preliminated Particle board top over chrome base leg all complete as per drawing design and direction of E/I.
Dining Table (Dining room of Guest House) - Size : (2000 x 800 x 750 mm H) - Supply Fabrication & Installation of Dining Table top of 19 mm thick PVC laminated board with 2 mm thick PVC edge banding , supported with M.S Rolling sqaure section framed complete with all fittings and assessories as per drawing & direction of E/I.
Meeting Table / Confrence Table - 22 persons Size : (5400 mm x 750mm x 900mm Ht.)
Executive table with return unit –
Sr.officers Table (size : 1350 x 750 x 750 mm)
Works station / Computer table (Size 1050 x 450 x 750mm (H)) Supply of Computer table made of 25 mm thick pre laminated particle board work top the tables will be lipped with PVC edge band of 2.0 mm thickness with frames : 50 mm thick and 1050 Ht , Base 700 mm five pronged base is made out of GF nylon - 6with an embedded metal rings and bottom ribs for additional support and strength lockable drawer unit and CPU stand wire manager at Top complete as per drawing design and direction of E/I.
Supplying, Fitting and Fixing of 3 seater chair (Chrome)
Supplying, Fitting and Fixing of Officer's Chair (Medium back) -
Supplying, Fitting and Fixing of Computer staff / visitor's chair (low back) -
Dining Chair - Supply , Fabrication and installation of dining chair with solid beech wood frame and legs with melamine polish. The seat and back rest shall be fully uphole stered with leatherlite / Fabric finish All complete as per drawing design and direction of E/I.
Dining Chair (Stackable ) for SHG Hall - Plastic Seat & BAck Without Arms and with Powdercoated Legs 'Providing and Fixing Featherlite Make MAGNA Chair The frame is made out of 22mm tube of 16gauge tube Welded by Co2 welding process for uniform surface, Thermo set powder coating epoxy polyester hybrids of harness (pencil) H.B.74 and impact resistant (in lab) 60-160 kgs cm and to a thickness of 40-50 microns is carried out of 7 step pretreatment process. The Back Shell is made out of Talc filled 10% poly propylene co polymer molded with ergonomic see through design
Godrej reception table size 2410x1065x725 work surface
Cantilever chair
Table with side unit return
Compactor
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc and disposing of surplus excavated soil as directed , within a lead of 50 m
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubbergasket, GI bolts, nuts, washers etc.as required :
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless steel (Grade 304)
Providing and fixing fully glazed MS fully welded construction double leaf door shutter for fire hydrant station fabricated from MS 50x50x6 mm angle iron frame, fixed to wall and hinged MS 40x40x5 mm angle iron door shutter with required MS sash bars for glazing complete with locking arrangements, stove enamelled fire red finish with 'FIRE HYDRANT' written in front. Approximate size 2100x900mm.
Providing and placing in proper position Stainless Steel 63mm dia short size branch pipes with 20 mm dia nozzles with 63mm instantaneous coupling ISI marked (IS:903).
Providing and fixing brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 and spindle AISI 410) with setting and gland of superior quality having minimum working pressure of 20 kg/cm2. 25mm dia
Supply, installation, testing & commissioning of 25mm dia air release valves of approved make on the top of each 150mm dia basement sprinkler ring main as per standard fire practice
Providing and fixing pressure gauges with isolation cocks and chrome plated copper pipes as hydrant station to read pressure from 0-25 kg/cm2 complete and of dial dia 150 mm.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipecoupling as required :
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft,mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation,conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.
a) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. c) SuitableHP squirell cage induction motor TEFC type suitablefor operation on 415 volts, 3 phase 50 Hz AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. d) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. e) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required
Providing, fixing, testing and commissiong of motor control centres fabricated from 16 gauges MS sheet with powder coated finish. The control panels should be comparable with H.P. of the motor as specified.
Providing and fixing motor control centres fabricated from 16 gauge M.S. sheet with Powder Coated finish. The control panels should be compatible with H.P. of the motor as under and as per spcifications with automatic star delta starters. (One separate panel to be located in the plant room).
Providing and fixing heavy duty Aluminum armored cables 1.1 KV grade including necessary support clamps at ceiling level, connection lugs and double compression glands, complete in all respects.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Supply, Installation, Testing & Commissioning of ISI marked (IS:15683) Portable fire extinguisher, of 4.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Supply, Installation, Testing & Commissioning of ISI marked (IS:2878) Portable fire extinguisher, of 22.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Supply, Installation, Testing & Commissioning of ISI marked (IS:15683) Portable fire extinguisher, of 4.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Supply, Installation, Testing & Commissioning of ISI marked (IS:2878) Portable fire extinguisher, of 22.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Description of Work
Earth work in excavation over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m; disposal earth to be levelled and neatly dressed.
Earth work in excavation in foundation trenches or drains (not excoding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the exvavted soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Extra for every additional lift of 1.5 m or part thereof in
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth : consolidating each deposited layer by ramming and watering lead.
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Clearing jungle including uprooting or rank vegetation, grass, brush wood, trees and scaplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Beyond 40 cm girth up to and including 60 cm grith
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Turfing with Sods (Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the engineer including preparation of ground, fetching of rods and watering)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.
1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1.4.8 (1 Cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size)
1:3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1:3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by the manufacturers.
Centring and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc., for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Shelves (Cast in situ)
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Post and struts
Stairs, (excluding landings) except spiral staircases.
Vertical and Horizontal fins individually or forming box louvers band, facias ane eaves boards.
Wheather shade, Chajja, corbels etc., including edges.
Edges of slabs and breaks in floors and walls :
Metre
Extra for shuttering in circular work (20% of respective centring and shuttering items)
Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc, including cost of de-shutering and de centring at all levels over a height of 3.5 m, for every additional height of 1 meter of part thereof (plan area to be measured)
Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete.
TMT-500- 8mm dia .
TMT-500-10 mm dia.
TMT-500-12 mm dia
TMT-500-16 mm dia.
TMT-500-20 mm dia.
TMT-500-25 mm dia
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
Concrete of M-25 grade with minimum cement content of 330 kg/cum
Concrete of M-25 grade with minimum cement content of 350 kg/cum
Concrete of M-25 grade with minimum cement content of 330 kg/cum
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete
All work upto plinth level
All works above plinth level upto floor V level
Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.
Add or deduct for providing richer or leaner mixes respectively at all floor levels
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level
Brick work with fly ash bricks as per IS 12894 (2002) & IS 3495 in foundations and plinth in :
Half brick Masonary Cement mortar 1.:4 (1 cement: 4 coarse sand ) - 125 mm th Brick work
Extra tor Brick work in superstructure above plinth level upto floor V cum
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S.pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin-charge
12 mm thick prelaminated (with decorative lamination on one side and balancing lamination on other side) particle board Grade -1 medium density flat pressed, three layer and graded (FPT-1) conforming to IS :3087 bonded with BWP type synthetic resin adhesive as per IS :848 and prelamination conforming to IS :12823 Grade-1 Type II
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type,core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
Providing and fixing aluminium sliding door bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ), transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (Over all area of door shutter to be measured).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:
Metre
Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C.doors) using synthetic rubber based adhesive.
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed onthe body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Metre
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - incharge. (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing non load bearing fixed frame for fire resistant glazed Partition for 120 min Fire Rating, made out to a profile of dimension 60mm x 70 mm of 1.6 mm thick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for 120 min of both integrity & radiation control (EW120) & minimum 15 min of insulation (El15). The profile has to be fixed to the supporting construction by means of anchor fasteners of size M10 x 80, every 150 mm from the edges and every 500 mm (approx) c/c. Linear meaurement of frame shall be measured for payment. The frame shall be filled with mineral wool insulation of density min 96kg/m³. and finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer -incharge.
Providing and fixing pressed steel door frame confirming IS code 351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-Charge.
Metre
Metre
Providing and fixing ISI marked steel glazed door, windows and ventilators of standard rolled steel section & joints mitered and welded with 15x3 mm lugs, 10cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawls plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with glazing clips and special metal sash putty of approved make complete including applying a priming coat of approved steel primer, but excluding the cost of steel beading and other fittings except necessary hinges or pivots as required.
Providing and fixing bright finished brass peg stays to steel ventilators with necessary welding and machine screws etc. complete.
Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete.
Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides.
Steel work welded in built up section/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Extra for providing and fixing steel beading of approved shape and section with screws instead of glaxing clips and met. Sash putty in steel doors, windows, Ventilators and comosite units.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-iron 40x40x6 mm with 40 mm dia steel pulleys complete with bots. Nuts locking arrangement stoppers handles including applying a priming coat of approved steel primer
Providing and fixing hand rail welding etc.to steel ladder ralling & staricases railing including
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / neling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)
"Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as pr IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the erimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.
Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete.
Providing flyash one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I.
Providing flyash one Brick on edge soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specifiction and direction of E/I.
Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Motar 1:3 (1cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) /1:4 (1 cement : 4 coarse sand)
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with:
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Area of slab upto 0.50 sqm
Area of slab over 0.50 sqm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of
Extra for Kota stone / sand stone in treads of steps and risers using single up to 1.05 metre.length
Extra for pre finished nosing in treads of steps of Kota stone / sand stone slab.
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622, of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of neat cement
12 mm cement plaster of mix
1:3(1 Cement :3 coarse sand)
1:4(1 Cement :4 coarse sand)
1:6 (1 cement : 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix.
15mm cement plaster 1:3 (1cement : 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall
6 mm cement plaster to ceiling of mix.
1:3(1 Cement :3 coarse sand)
1:4 (1 cement : 4 coarse sand)
White washing with whiting to give an even shade.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
Distempering with 1st quality washable distemper (ready made ) of approved manufacturer and of required shade and colour complete. As per manufacture's specifications.
Applying priming coat:
With ready mixed pink or grey primer of approved brand and manufacture on woodwork (hard and soft wood)
With ready mixed red oxide zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works
Finishing walls with Acrylic Smooth exterior paint of required shade :
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
Painting with synthetic enamel paint of approved brand and manufacture to give an even shed.
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Forming groove of uniform size from 12 x 12 mm and upto 25 x 15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
Neat Cement punning
Applying one coat of cement primer of approved brand and manufacture on wall surface :
Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give and even shade
Stone work (machine cut edge) for wall lining etc. (veneer work) over 12 mm thick bed of cement lime mortar 1:1:6 (1cement : 1 lime putty : 6 fine sand) including pointing in white cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid for seperately)
Providing and fixing gun metal cramps of required shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 ( 1cement : 2 fine sand) including making the necessary chases.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part there of
Rough cast plaster with a mixture of sand and gravel or crushed stone from 2.36 to 12.5 mm nominal size dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:5 (1 cement:5coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement:3 corse sand) mixed with 10% finely grounded hydrated lime by volume of cement :
Extra for plastering :
Finishing walls with Premium Acrylic smooth exterior paint with silicone additives of required shade.
Finishing walls with textured exterior of required shade :
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed protions of W.C. kitchen and the like consisting of :
Grading roof for water proofing treatment with
Providing and laying integral cement based water proofing treatment including repatation of surface as required for treatment of roofs, balconies , terraces etc, consisting of following operations. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water -proofing compound cleaning the surface before treatment, (b) Laying cement concrete using broken bricks / brick bats 25 mm to 100 mm size with 50 % of cement mortar 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mmthick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water froofing compound onforming to IS 2545 to reuired slope and treating similary the adjoining walls upto 300 mm height including rounding of junctions, or walls ad slabs. (c) After two days of proper curing applying a secoung coat of cement slurry admixed with proprietary waterproofing compound conforming to IS :
Providing and Laying APP (Atactic Polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre /sqm by the same membrane manufacture of density at 250 C, 0.87-0.89 kg / litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The Vital physical and chemical parameters of the membrane shall be as under : Joint strength in logitudinal and transverse direction at 230 C as 650/ 450N / 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 1500C. Cold flexibility shall be upto -20C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100%polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing flooring under portico consisting of 100mm PCC ( 1:2:4 ) over brick on edge soling over 100 mm sand filling.
Providing plain cement concrete in (1:2:4) including making grooves laid in pattern of tiles 300 x 300 mm avg. thickness 40 mm on sloped roof as per drawings all complete.
Making khurras 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1cement:3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
Providng and filling in position, blown bitumen in expansion joints.
100m (Length) x1cm (Wide)x 1cm (Depth)
Providng and fixing sheet covering over expansion joints with iron screws as per design to match the colour/shade of wall treatment,
Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termites' treatrnent (including the cost of chemical emulsion)
Along external wall where the apron is not provided using chemical imulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete.
Metre
Along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.
Metre
Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I.
Providing and fixing Wire mesh
Marble work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work) in c ement mortar 1:3 (1 cement :3 coarse sand) including pointing with white coment mortar 1:2(1 shite cement:2 marble dust) with an admixture of pigment to match the marble shade:(To be secured to the backing by means of cramps, which shall be paid for separately)
Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections.
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia 0.63 mm all complete.
Signage
Supplying and fixing C.I. cover without frame for manholes :
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing in position 25mm diameter mosquito proof coupling of approved municipal design
Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of / and manure before and after flooring trench with water (excluding cost of imported earth, sludge or manure)
Supplying and stacking of good earth at site including royalty but excluding carriage (earth measured in stacks will be reduced by 20 % for payment)
Supplying and stacking at site dump manure from approved source, excluding carriage (manure measured in stacks will be reduced by 8% for payment)
Mixing earth and sludge or manure in proportion specified or directed.
Spreading of sludge, dump manutre or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately)
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking clods, rought dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.
Grassing with 'Doob' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free form weeds and fit for moving including supplying good earth if needed.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20 % 1 part of stacked volume of manure after reduction by 8 % ) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure sludge or extra good earth if needed to be paid for separately)
Holes 1.2 m dia. And 1.2 m deep.
Holes 60 cm dia. And 60 cm deep.
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8 :1 (8 parts of stacked volume of earth after reduction by 8% ) flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)
Plantation of trees & Shrubs/ creeps.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge:
Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5 mm), including making drainage opening wherever required etc. complete as per direction of Engineer-in-charge. (Length of finished kerb edging shall be measured for payment). (Old kerb stones shall be supplied by the department free of cost)
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-incharge.
Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in theproportion of 1:2 (1 cement : 2 fine sand) including testing of jointsetc. complete :300 mm dia. R.C.C. Pipe
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacture's specifications including appropriate priming coat, preparation of surface, etc, complete.
per 1000 nos
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including, cutting and making good the walls etc. (internal work)
Metre
Metre
Metre
Metre
Metre
Metre
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
Metre
Metre
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc . (external work)
Providing and fixing brass bib cock of approved quality.
Providing and fixing brass stop cock of approved quality (screwed end).
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end).
Providing and fixing gun metal non-return valve of approved quality (screwed end)
50mm nominal bore
32mm nominal bore
32mm nominal bore
Horizontal
Providing and fixing P V C connection pipe with brass unions.
Providing and fixing C.P. brass shower rose 15 or 20 mm inlet.
Constructing masonry Chamber 30 x 30 x 50 cm inside, in brick work in cement mortar 1:4( 1 cement: 4 coarse sand) for stop cock, with C.I surface box 100 x 100 x 75 mm(inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation, foundation concrete 1:5:10( 1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:
Constructing masonry Chamber 60 x 60 x 75 cm inside, in brick work in cement mortar 1:4(1 cement: 4 coarse sand) for sluice valve, with C.I surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necesary excavation, foundation concrete 1:5:10( 1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3( 1 cement: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:nt complete as per standard design.
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
Metre
Metre
Metre
Metre
Metre
Metre
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :
meter
meter
meter
Providing & filling sand of grading zone V or coarser grade all-around G.I. pipes in external work.
Metre
Metre
Metre
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc.complete (new work)
Providing and fixing C.P. brass,bib cock of approved quality conforming to IS : 8931
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS stamdards and weighing notless than 810 gms.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS stamdards and weighing notless than 690 gms.
Providing and fixing C.P brass stop cock (concealed) of standard design and of approved mark conforming to IS:8931
Providing and fixing C.P brass angle valve for basin mixer and gyser points of approved quality conforming to IS: 8931
Providing and fixing PTMT Soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Cutting holes up to 30 x 30 cm in walls including making good the same:
Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including finishing complete so as to make it leak proof.
Making holes up to 20 x 20 cm and embedding pipes upto 150 mm in diametre in masonary and filling with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) including dispopsal of malba.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
Provoding and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug , 40 mm C.P brass waste complete, including painting the fittings and brackets, cutting and making good the walls whereever required.
Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5 mm glass shelf with edges round off,supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
Providing and fixing soil, waste and vent pipes
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),including cost of cutting holes and making good the walls etc. :
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick bolts and nutts complete
Providing and fixing plain bend of required degree
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete.
Providing and fixing terminal guard
Providing lead caulked joints to sand cast iron/ centrifugally cast (spun) iron pipes and fittings of diameter
Providing and fixing trap of self cleaning design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.
Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :
metre
Providing and fixing on wall face unplasticised PVC (working pressure 4 kg per sqcm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
Metre
Providing and fixing on wall face unplasticised PVC moulded fittings / accessories for unplasticised-PVC rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
Single pushfit Coupler:
Single tee with door
Shoe plain
Providing and fixing unplasticised-PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S screws or required length including cutting brick work and fixing on cement mortar (1:4) 1 cement:4 coarse sand and making good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :
Providing and fixing white vitreous china pedastal type water closet (European type W.C pan) with seat and lid, 10 litre low level white P.V.C flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions G.I. clamps, complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:
Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C.automatic flushing cistern, with fittings, standard size G.I. / PVCflush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required :
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone finished smooth.aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distances of 37mm fromwall face with concealed fittings arrangement of approved quality, and colour, weighing not less than 88 gms.
Cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement: 3 coarse sand : 6 graded stonea agregate 12.5mm nominal size) including necessry plaster and pointing in cement mortar 1:4 ( 1 cement: 4 coarse sand):
Metre
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
Metre
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes inlcuding bed concrete as per standard design.
Metre
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
Providing and laying non-pressure NP2 class (light duty) R.CC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2( 1 cement: 2 fine sand) including testing of joints etc. complete.
Metre
Metre
Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.
Constructing brick masonry manhole in cement mortar 1:4(1 cement: 4 coarse sand) with R.C.C top slab with 1:2:4 mix (1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand:8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3( 1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design:
Extra for depth for manholes Size 90 x 80 cm with common burnt clay F.P.S (non modular) bricks of class designation 7.5
Constructing brick masonry chamber for underground C.I inspection chamber and bends with bricks in cement mortar 1:4( 1 cement: 4 coarse sand) C.I cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg) R.C.C top slab ith 1:2:4 mix ( 1 cement: 2 coarse sand:4 graded stone aggregate 20mm nominal size) foundtion concrete 1:5:10( 1 cement: 5 fine sand:10 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
Extra for depth beyond 45 cm of brick masonry chambar For 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Providing 150mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron concrete (1: 4:8), over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l,
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
metre
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -in-charge.
metre
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
metre
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe,removable as per requirement, all complete for borewell of:
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia
Gravel packing in tubewell construction in accordance with IS:4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
S/F/F Submersible 1.5H.P pump
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking TGrid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The
Providing, fittings & fixing vertical venetian blinds (of vista, mac make) to window made with aluminium slate or approved thickness, colour quality with all accessories including adjuster, hardworks complete with all labour and materials in all floors.Design and colour to be approved first by Engineer-in-Charge.
Providing and fixing anodised aluminium work for doors, windows, ventilator? and partitions with extruded built up standard tubular and otner sections of approved make conforming to IS : 733 and IS : 1285,anodised trasparent or dyed to required shade according to IS : 1868,(Minimum anodic coating of grade AC 15), fixed with.rawl plugs and screws or with fixing clips , or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust fre straight, mitred and jointed mechanically wherever required including cleat angle,.Aluminium snap beading tor glazing/paneling, C.P. brass/stainless steel screws, all complete as per architecttural drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately.)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Providing & fixing of Aluminium Framed preliminated painted board complete wirth fixing of room no. / name plate / exit route in Hostel rooms & chambers of Institute block and hostel as per choice of client / E/I
Full height storage (size : 1200 L x 1975 H x 600 D) for Record room Making, supply and installation of Wooden Wardrob, 600mm deep, the sides, Top of B.W.P. lesard with 1.0 mm laminates finish. 12 mm thick B.W.P. Ply The front shutter with 19 mm thick B.W.P. Ply wood of century ply or equivalent with 1.0 mm thick. laminates movable roller, channel, recess knob Itallica Locks glass etc. including all fitting & fixture shall be complete in all respect. as per drawing and direction of E/I.
Storage Unit Low Height for Officer chamber (size :1050L x 430W x 750H) Supply , Fabrication and Installation of low height storage unit. The structure of made out of 18mm thick pre-laminated board (PLB). The shelves are made out of 18mm thick (PLB) , which are adjustable in height. The shutters are made out of 18 mm (PLB) openable and fitted by hinges, recessed handles, locking unit and levelers are considered, all complete as per drawing and directly of E/I.
Information Desk : (3775 x 750 x 900 h) Supplying and fixing Information Desk made of 25 mm thick prelaminated board top with PVC edge binding on wooden frame completes with shelves, key board and CPU Trolley, wire manager with all hardware. Internal wooden surface polished all complete per drawing and direction of E.I.
Interaction Countre : Size (4200 mm x 750 x 900 H) Supplying and fixing Interaction Countre made of 25 mm thick prelaminated board top with PVC edge binding on wooden frame completes with shelves, key board and CPU Trolley, wire manager with all hardware. Internal wooden surface polished all complete per drawing and direction of E.I.
Side table (size : 510 x 440 x 450mm) Supply,Fabrication & Installation of side table made of prelaminated board top matched with bed finish , with all necessary fixtures and fittings complete as per drawing and direction of E/I.
Canteen Table - (Size : 900 x 900) - Supply Fabrication and Installation of rectangular table of size (900 x 900 x 750 H) with preliminated Particle board top over chrome base leg all complete as per drawing design and direction of E/I.
Dining Table (Dining room of Guest House) - Size : (2000 x 800 x 750 mm H) - Supply Fabrication & Installation of Dining Table top of 19 mm thick PVC laminated board with 2 mm thick PVC edge banding , supported with M.S Rolling sqaure section framed complete with all fittings and assessories as per drawing & direction of E/I.
Meeting Table / Confrence Table - 22 persons Size : (5400 mm x 750mm x 900mm Ht.)
Executive table with return unit –
Sr.officers Table (size : 1350 x 750 x 750 mm)
Works station / Computer table (Size 1050 x 450 x 750mm (H)) Supply of Computer table made of 25 mm thick pre laminated particle board work top the tables will be lipped with PVC edge band of 2.0 mm thickness with frames : 50 mm thick and 1050 Ht , Base 700 mm five pronged base is made out of GF nylon - 6with an embedded metal rings and bottom ribs for additional support and strength lockable drawer unit and CPU stand wire manager at Top complete as per drawing design and direction of E/I.
Supplying, Fitting and Fixing of 3 seater chair (Chrome)
Supplying, Fitting and Fixing of Officer's Chair (Medium back) -
Supplying, Fitting and Fixing of Computer staff / visitor's chair (low back) -
Dining Chair - Supply , Fabrication and installation of dining chair with solid beech wood frame and legs with melamine polish. The seat and back rest shall be fully uphole stered with leatherlite / Fabric finish All complete as per drawing design and direction of E/I.
Dining Chair (Stackable ) for SHG Hall - Plastic Seat & BAck Without Arms and with Powdercoated Legs 'Providing and Fixing Featherlite Make MAGNA Chair The frame is made out of 22mm tube of 16gauge tube Welded by Co2 welding process for uniform surface, Thermo set powder coating epoxy polyester hybrids of harness (pencil) H.B.74 and impact resistant (in lab) 60-160 kgs cm and to a thickness of 40-50 microns is carried out of 7 step pretreatment process. The Back Shell is made out of Talc filled 10% poly propylene co polymer molded with ergonomic see through design
Godrej reception table size 2410x1065x725 work surface
Cantilever chair
Table with side unit return
Compactor
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc and disposing of surplus excavated soil as directed , within a lead of 50 m
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubbergasket, GI bolts, nuts, washers etc.as required :
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless steel (Grade 304)
Providing and fixing fully glazed MS fully welded construction double leaf door shutter for fire hydrant station fabricated from MS 50x50x6 mm angle iron frame, fixed to wall and hinged MS 40x40x5 mm angle iron door shutter with required MS sash bars for glazing complete with locking arrangements, stove enamelled fire red finish with 'FIRE HYDRANT' written in front. Approximate size 2100x900mm.
Providing and placing in proper position Stainless Steel 63mm dia short size branch pipes with 20 mm dia nozzles with 63mm instantaneous coupling ISI marked (IS:903).
Providing and fixing brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 and spindle AISI 410) with setting and gland of superior quality having minimum working pressure of 20 kg/cm2. 25mm dia
Supply, installation, testing & commissioning of 25mm dia air release valves of approved make on the top of each 150mm dia basement sprinkler ring main as per standard fire practice
Providing and fixing pressure gauges with isolation cocks and chrome plated copper pipes as hydrant station to read pressure from 0-25 kg/cm2 complete and of dial dia 150 mm.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipecoupling as required :
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft,mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation,conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.
a) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. c) SuitableHP squirell cage induction motor TEFC type suitablefor operation on 415 volts, 3 phase 50 Hz AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. d) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. e) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required
Providing, fixing, testing and commissiong of motor control centres fabricated from 16 gauges MS sheet with powder coated finish. The control panels should be comparable with H.P. of the motor as specified.
Providing and fixing motor control centres fabricated from 16 gauge M.S. sheet with Powder Coated finish. The control panels should be compatible with H.P. of the motor as under and as per spcifications with automatic star delta starters. (One separate panel to be located in the plant room).
Providing and fixing heavy duty Aluminum armored cables 1.1 KV grade including necessary support clamps at ceiling level, connection lugs and double compression glands, complete in all respects.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Supply, Installation, Testing & Commissioning of ISI marked (IS:15683) Portable fire extinguisher, of 4.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Supply, Installation, Testing & Commissioning of ISI marked (IS:2878) Portable fire extinguisher, of 22.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Supply, Installation, Testing & Commissioning of ISI marked (IS:15683) Portable fire extinguisher, of 4.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Supply, Installation, Testing & Commissioning of ISI marked (IS:2878) Portable fire extinguisher, of 22.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Description of Work
Earth work in excavation over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m; disposal earth to be levelled and neatly dressed.
Earth work in excavation in foundation trenches or drains (not excoding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the exvavted soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Extra for every additional lift of 1.5 m or part thereof in
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth : consolidating each deposited layer by ramming and watering lead.
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Clearing jungle including uprooting or rank vegetation, grass, brush wood, trees and scaplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Beyond 40 cm girth up to and including 60 cm grith
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Turfing with Sods (Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the engineer including preparation of ground, fetching of rods and watering)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.
1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1.4.8 (1 Cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size)
1:3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1:3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by the manufacturers.
Centring and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc., for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Shelves (Cast in situ)
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Post and struts
Stairs, (excluding landings) except spiral staircases.
Vertical and Horizontal fins individually or forming box louvers band, facias ane eaves boards.
Wheather shade, Chajja, corbels etc., including edges.
Edges of slabs and breaks in floors and walls :
Metre
Extra for shuttering in circular work (20% of respective centring and shuttering items)
Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc, including cost of de-shutering and de centring at all levels over a height of 3.5 m, for every additional height of 1 meter of part thereof (plan area to be measured)
Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete.
TMT-500- 8mm dia .
TMT-500-10 mm dia.
TMT-500-12 mm dia
TMT-500-16 mm dia.
TMT-500-20 mm dia.
TMT-500-25 mm dia
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
Concrete of M-25 grade with minimum cement content of 330 kg/cum
Concrete of M-25 grade with minimum cement content of 350 kg/cum
Concrete of M-25 grade with minimum cement content of 330 kg/cum
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete
All work upto plinth level
All works above plinth level upto floor V level
Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.
Add or deduct for providing richer or leaner mixes respectively at all floor levels
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level
Brick work with fly ash bricks as per IS 12894 (2002) & IS 3495 in foundations and plinth in :
Half brick Masonary Cement mortar 1.:4 (1 cement: 4 coarse sand ) - 125 mm th Brick work
Extra tor Brick work in superstructure above plinth level upto floor V cum
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S.pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin-charge
12 mm thick prelaminated (with decorative lamination on one side and balancing lamination on other side) particle board Grade -1 medium density flat pressed, three layer and graded (FPT-1) conforming to IS :3087 bonded with BWP type synthetic resin adhesive as per IS :848 and prelamination conforming to IS :12823 Grade-1 Type II
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type,core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
Providing and fixing aluminium sliding door bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ), transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (Over all area of door shutter to be measured).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:
Metre
Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C.doors) using synthetic rubber based adhesive.
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed onthe body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Metre
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - incharge. (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing non load bearing fixed frame for fire resistant glazed Partition for 120 min Fire Rating, made out to a profile of dimension 60mm x 70 mm of 1.6 mm thick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for 120 min of both integrity & radiation control (EW120) & minimum 15 min of insulation (El15). The profile has to be fixed to the supporting construction by means of anchor fasteners of size M10 x 80, every 150 mm from the edges and every 500 mm (approx) c/c. Linear meaurement of frame shall be measured for payment. The frame shall be filled with mineral wool insulation of density min 96kg/m³. and finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer -incharge.
Providing and fixing pressed steel door frame confirming IS code 351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-Charge.
Metre
Metre
Providing and fixing ISI marked steel glazed door, windows and ventilators of standard rolled steel section & joints mitered and welded with 15x3 mm lugs, 10cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawls plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with glazing clips and special metal sash putty of approved make complete including applying a priming coat of approved steel primer, but excluding the cost of steel beading and other fittings except necessary hinges or pivots as required.
Providing and fixing bright finished brass peg stays to steel ventilators with necessary welding and machine screws etc. complete.
Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete.
Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides.
Steel work welded in built up section/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Extra for providing and fixing steel beading of approved shape and section with screws instead of glaxing clips and met. Sash putty in steel doors, windows, Ventilators and comosite units.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-iron 40x40x6 mm with 40 mm dia steel pulleys complete with bots. Nuts locking arrangement stoppers handles including applying a priming coat of approved steel primer
Providing and fixing hand rail welding etc.to steel ladder ralling & staricases railing including
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / neling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)
"Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as pr IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the erimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.
Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete.
Providing flyash one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I.
Providing flyash one Brick on edge soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specifiction and direction of E/I.
Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Motar 1:3 (1cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) /1:4 (1 cement : 4 coarse sand)
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with:
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Area of slab upto 0.50 sqm
Area of slab over 0.50 sqm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of
Extra for Kota stone / sand stone in treads of steps and risers using single up to 1.05 metre.length
Extra for pre finished nosing in treads of steps of Kota stone / sand stone slab.
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622, of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of neat cement
12 mm cement plaster of mix
1:3(1 Cement :3 coarse sand)
1:4(1 Cement :4 coarse sand)
1:6 (1 cement : 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix.
15mm cement plaster 1:3 (1cement : 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall
6 mm cement plaster to ceiling of mix.
1:3(1 Cement :3 coarse sand)
1:4 (1 cement : 4 coarse sand)
White washing with whiting to give an even shade.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
Distempering with 1st quality washable distemper (ready made ) of approved manufacturer and of required shade and colour complete. As per manufacture's specifications.
Applying priming coat:
With ready mixed pink or grey primer of approved brand and manufacture on woodwork (hard and soft wood)
With ready mixed red oxide zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works
Finishing walls with Acrylic Smooth exterior paint of required shade :
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
Painting with synthetic enamel paint of approved brand and manufacture to give an even shed.
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Forming groove of uniform size from 12 x 12 mm and upto 25 x 15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
Neat Cement punning
Applying one coat of cement primer of approved brand and manufacture on wall surface :
Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give and even shade
Stone work (machine cut edge) for wall lining etc. (veneer work) over 12 mm thick bed of cement lime mortar 1:1:6 (1cement : 1 lime putty : 6 fine sand) including pointing in white cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid for seperately)
Providing and fixing gun metal cramps of required shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 ( 1cement : 2 fine sand) including making the necessary chases.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part there of
Rough cast plaster with a mixture of sand and gravel or crushed stone from 2.36 to 12.5 mm nominal size dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:5 (1 cement:5coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement:3 corse sand) mixed with 10% finely grounded hydrated lime by volume of cement :
Extra for plastering :
Finishing walls with Premium Acrylic smooth exterior paint with silicone additives of required shade.
Finishing walls with textured exterior of required shade :
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed protions of W.C. kitchen and the like consisting of :
Grading roof for water proofing treatment with
Providing and laying integral cement based water proofing treatment including repatation of surface as required for treatment of roofs, balconies , terraces etc, consisting of following operations. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water -proofing compound cleaning the surface before treatment, (b) Laying cement concrete using broken bricks / brick bats 25 mm to 100 mm size with 50 % of cement mortar 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mmthick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water froofing compound onforming to IS 2545 to reuired slope and treating similary the adjoining walls upto 300 mm height including rounding of junctions, or walls ad slabs. (c) After two days of proper curing applying a secoung coat of cement slurry admixed with proprietary waterproofing compound conforming to IS :
Providing and Laying APP (Atactic Polypropylene polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre /sqm by the same membrane manufacture of density at 250 C, 0.87-0.89 kg / litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The Vital physical and chemical parameters of the membrane shall be as under : Joint strength in logitudinal and transverse direction at 230 C as 650/ 450N / 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 1500C. Cold flexibility shall be upto -20C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100%polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing flooring under portico consisting of 100mm PCC ( 1:2:4 ) over brick on edge soling over 100 mm sand filling.
Providing plain cement concrete in (1:2:4) including making grooves laid in pattern of tiles 300 x 300 mm avg. thickness 40 mm on sloped roof as per drawings all complete.
Making khurras 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1cement:3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
Providng and filling in position, blown bitumen in expansion joints.
100m (Length) x1cm (Wide)x 1cm (Depth)
Providng and fixing sheet covering over expansion joints with iron screws as per design to match the colour/shade of wall treatment,
Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termites' treatrnent (including the cost of chemical emulsion)
Along external wall where the apron is not provided using chemical imulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete.
Metre
Along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.
Metre
Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I.
Providing and fixing Wire mesh
Marble work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work) in c ement mortar 1:3 (1 cement :3 coarse sand) including pointing with white coment mortar 1:2(1 shite cement:2 marble dust) with an admixture of pigment to match the marble shade:(To be secured to the backing by means of cramps, which shall be paid for separately)
Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections.
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia 0.63 mm all complete.
Signage
Supplying and fixing C.I. cover without frame for manholes :
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing in position 25mm diameter mosquito proof coupling of approved municipal design
Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of / and manure before and after flooring trench with water (excluding cost of imported earth, sludge or manure)
Supplying and stacking of good earth at site including royalty but excluding carriage (earth measured in stacks will be reduced by 20 % for payment)
Supplying and stacking at site dump manure from approved source, excluding carriage (manure measured in stacks will be reduced by 8% for payment)
Mixing earth and sludge or manure in proportion specified or directed.
Spreading of sludge, dump manutre or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately)
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking clods, rought dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.
Grassing with 'Doob' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free form weeds and fit for moving including supplying good earth if needed.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20 % 1 part of stacked volume of manure after reduction by 8 % ) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure sludge or extra good earth if needed to be paid for separately)
Holes 1.2 m dia. And 1.2 m deep.
Holes 60 cm dia. And 60 cm deep.
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8 :1 (8 parts of stacked volume of earth after reduction by 8% ) flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)
Plantation of trees & Shrubs/ creeps.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge:
Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5 mm), including making drainage opening wherever required etc. complete as per direction of Engineer-in-charge. (Length of finished kerb edging shall be measured for payment). (Old kerb stones shall be supplied by the department free of cost)
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-incharge.
Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in theproportion of 1:2 (1 cement : 2 fine sand) including testing of jointsetc. complete :300 mm dia. R.C.C. Pipe
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacture's specifications including appropriate priming coat, preparation of surface, etc, complete.
per 1000 nos
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including, cutting and making good the walls etc. (internal work)
Metre
Metre
Metre
Metre
Metre
Metre
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
Metre
Metre
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc . (external work)
Providing and fixing brass bib cock of approved quality.
Providing and fixing brass stop cock of approved quality (screwed end).
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end).
Providing and fixing gun metal non-return valve of approved quality (screwed end)
50mm nominal bore
32mm nominal bore
32mm nominal bore
Horizontal
Providing and fixing P V C connection pipe with brass unions.
Providing and fixing C.P. brass shower rose 15 or 20 mm inlet.
Constructing masonry Chamber 30 x 30 x 50 cm inside, in brick work in cement mortar 1:4( 1 cement: 4 coarse sand) for stop cock, with C.I surface box 100 x 100 x 75 mm(inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation, foundation concrete 1:5:10( 1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:
Constructing masonry Chamber 60 x 60 x 75 cm inside, in brick work in cement mortar 1:4(1 cement: 4 coarse sand) for sluice valve, with C.I surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necesary excavation, foundation concrete 1:5:10( 1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3( 1 cement: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:nt complete as per standard design.
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
Metre
Metre
Metre
Metre
Metre
Metre
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :
meter
meter
meter
Providing & filling sand of grading zone V or coarser grade all-around G.I. pipes in external work.
Metre
Metre
Metre
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc.complete (new work)
Providing and fixing C.P. brass,bib cock of approved quality conforming to IS : 8931
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS stamdards and weighing notless than 810 gms.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS stamdards and weighing notless than 690 gms.
Providing and fixing C.P brass stop cock (concealed) of standard design and of approved mark conforming to IS:8931
Providing and fixing C.P brass angle valve for basin mixer and gyser points of approved quality conforming to IS: 8931
Providing and fixing PTMT Soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Cutting holes up to 30 x 30 cm in walls including making good the same:
Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including finishing complete so as to make it leak proof.
Making holes up to 20 x 20 cm and embedding pipes upto 150 mm in diametre in masonary and filling with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) including dispopsal of malba.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
Provoding and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug , 40 mm C.P brass waste complete, including painting the fittings and brackets, cutting and making good the walls whereever required.
Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5 mm glass shelf with edges round off,supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
Providing and fixing soil, waste and vent pipes
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),including cost of cutting holes and making good the walls etc. :
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick bolts and nutts complete
Providing and fixing plain bend of required degree
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete.
Providing and fixing terminal guard
Providing lead caulked joints to sand cast iron/ centrifugally cast (spun) iron pipes and fittings of diameter
Providing and fixing trap of self cleaning design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.
Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :
metre
Providing and fixing on wall face unplasticised PVC (working pressure 4 kg per sqcm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
Metre
Providing and fixing on wall face unplasticised PVC moulded fittings / accessories for unplasticised-PVC rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
Single pushfit Coupler:
Single tee with door
Shoe plain
Providing and fixing unplasticised-PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S screws or required length including cutting brick work and fixing on cement mortar (1:4) 1 cement:4 coarse sand and making good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :
Providing and fixing white vitreous china pedastal type water closet (European type W.C pan) with seat and lid, 10 litre low level white P.V.C flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions G.I. clamps, complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:
Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C.automatic flushing cistern, with fittings, standard size G.I. / PVCflush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required :
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone finished smooth.aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distances of 37mm fromwall face with concealed fittings arrangement of approved quality, and colour, weighing not less than 88 gms.
Cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement: 3 coarse sand : 6 graded stonea agregate 12.5mm nominal size) including necessry plaster and pointing in cement mortar 1:4 ( 1 cement: 4 coarse sand):
Metre
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
Metre
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes inlcuding bed concrete as per standard design.
Metre
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
Providing and laying non-pressure NP2 class (light duty) R.CC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2( 1 cement: 2 fine sand) including testing of joints etc. complete.
Metre
Metre
Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.
Constructing brick masonry manhole in cement mortar 1:4(1 cement: 4 coarse sand) with R.C.C top slab with 1:2:4 mix (1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand:8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3( 1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design:
Extra for depth for manholes Size 90 x 80 cm with common burnt clay F.P.S (non modular) bricks of class designation 7.5
Constructing brick masonry chamber for underground C.I inspection chamber and bends with bricks in cement mortar 1:4( 1 cement: 4 coarse sand) C.I cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg) R.C.C top slab ith 1:2:4 mix ( 1 cement: 2 coarse sand:4 graded stone aggregate 20mm nominal size) foundtion concrete 1:5:10( 1 cement: 5 fine sand:10 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
Extra for depth beyond 45 cm of brick masonry chambar For 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Providing 150mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron concrete (1: 4:8), over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l,
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
metre
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -in-charge.
metre
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
metre
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe,removable as per requirement, all complete for borewell of:
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia
Gravel packing in tubewell construction in accordance with IS:4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
S/F/F Submersible 1.5H.P pump
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking TGrid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The
Providing, fittings & fixing vertical venetian blinds (of vista, mac make) to window made with aluminium slate or approved thickness, colour quality with all accessories including adjuster, hardworks complete with all labour and materials in all floors.Design and colour to be approved first by Engineer-in-Charge.
Providing and fixing anodised aluminium work for doors, windows, ventilator? and partitions with extruded built up standard tubular and otner sections of approved make conforming to IS : 733 and IS : 1285,anodised trasparent or dyed to required shade according to IS : 1868,(Minimum anodic coating of grade AC 15), fixed with.rawl plugs and screws or with fixing clips , or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust fre straight, mitred and jointed mechanically wherever required including cleat angle,.Aluminium snap beading tor glazing/paneling, C.P. brass/stainless steel screws, all complete as per architecttural drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately.)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Providing & fixing of Aluminium Framed preliminated painted board complete wirth fixing of room no. / name plate / exit route in Hostel rooms & chambers of Institute block and hostel as per choice of client / E/I
Full height storage (size : 1200 L x 1975 H x 600 D) for Record room Making, supply and installation of Wooden Wardrob, 600mm deep, the sides, Top of B.W.P. lesard with 1.0 mm laminates finish. 12 mm thick B.W.P. Ply The front shutter with 19 mm thick B.W.P. Ply wood of century ply or equivalent with 1.0 mm thick. laminates movable roller, channel, recess knob Itallica Locks glass etc. including all fitting & fixture shall be complete in all respect. as per drawing and direction of E/I.
Storage Unit Low Height for Officer chamber (size :1050L x 430W x 750H) Supply , Fabrication and Installation of low height storage unit. The structure of made out of 18mm thick pre-laminated board (PLB). The shelves are made out of 18mm thick (PLB) , which are adjustable in height. The shutters are made out of 18 mm (PLB) openable and fitted by hinges, recessed handles, locking unit and levelers are considered, all complete as per drawing and directly of E/I.
Information Desk : (3775 x 750 x 900 h) Supplying and fixing Information Desk made of 25 mm thick prelaminated board top with PVC edge binding on wooden frame completes with shelves, key board and CPU Trolley, wire manager with all hardware. Internal wooden surface polished all complete per drawing and direction of E.I.
Interaction Countre : Size (4200 mm x 750 x 900 H) Supplying and fixing Interaction Countre made of 25 mm thick prelaminated board top with PVC edge binding on wooden frame completes with shelves, key board and CPU Trolley, wire manager with all hardware. Internal wooden surface polished all complete per drawing and direction of E.I.
Side table (size : 510 x 440 x 450mm) Supply,Fabrication & Installation of side table made of prelaminated board top matched with bed finish , with all necessary fixtures and fittings complete as per drawing and direction of E/I.
Canteen Table - (Size : 900 x 900) - Supply Fabrication and Installation of rectangular table of size (900 x 900 x 750 H) with preliminated Particle board top over chrome base leg all complete as per drawing design and direction of E/I.
Dining Table (Dining room of Guest House) - Size : (2000 x 800 x 750 mm H) - Supply Fabrication & Installation of Dining Table top of 19 mm thick PVC laminated board with 2 mm thick PVC edge banding , supported with M.S Rolling sqaure section framed complete with all fittings and assessories as per drawing & direction of E/I.
Meeting Table / Confrence Table - 22 persons Size : (5400 mm x 750mm x 900mm Ht.)
Executive table with return unit –
Sr.officers Table (size : 1350 x 750 x 750 mm)
Works station / Computer table (Size 1050 x 450 x 750mm (H)) Supply of Computer table made of 25 mm thick pre laminated particle board work top the tables will be lipped with PVC edge band of 2.0 mm thickness with frames : 50 mm thick and 1050 Ht , Base 700 mm five pronged base is made out of GF nylon - 6with an embedded metal rings and bottom ribs for additional support and strength lockable drawer unit and CPU stand wire manager at Top complete as per drawing design and direction of E/I.
Supplying, Fitting and Fixing of 3 seater chair (Chrome)
Supplying, Fitting and Fixing of Officer's Chair (Medium back) -
Supplying, Fitting and Fixing of Computer staff / visitor's chair (low back) -
Dining Chair - Supply , Fabrication and installation of dining chair with solid beech wood frame and legs with melamine polish. The seat and back rest shall be fully uphole stered with leatherlite / Fabric finish All complete as per drawing design and direction of E/I.
Dining Chair (Stackable ) for SHG Hall - Plastic Seat & BAck Without Arms and with Powdercoated Legs 'Providing and Fixing Featherlite Make MAGNA Chair The frame is made out of 22mm tube of 16gauge tube Welded by Co2 welding process for uniform surface, Thermo set powder coating epoxy polyester hybrids of harness (pencil) H.B.74 and impact resistant (in lab) 60-160 kgs cm and to a thickness of 40-50 microns is carried out of 7 step pretreatment process. The Back Shell is made out of Talc filled 10% poly propylene co polymer molded with ergonomic see through design
Godrej reception table size 2410x1065x725 work surface
Cantilever chair
Table with side unit return
Compactor
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc and disposing of surplus excavated soil as directed , within a lead of 50 m
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubbergasket, GI bolts, nuts, washers etc.as required :
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless steel (Grade 304)
Providing and fixing fully glazed MS fully welded construction double leaf door shutter for fire hydrant station fabricated from MS 50x50x6 mm angle iron frame, fixed to wall and hinged MS 40x40x5 mm angle iron door shutter with required MS sash bars for glazing complete with locking arrangements, stove enamelled fire red finish with 'FIRE HYDRANT' written in front. Approximate size 2100x900mm.
Providing and placing in proper position Stainless Steel 63mm dia short size branch pipes with 20 mm dia nozzles with 63mm instantaneous coupling ISI marked (IS:903).
Providing and fixing brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 and spindle AISI 410) with setting and gland of superior quality having minimum working pressure of 20 kg/cm2. 25mm dia
Supply, installation, testing & commissioning of 25mm dia air release valves of approved make on the top of each 150mm dia basement sprinkler ring main as per standard fire practice
Providing and fixing pressure gauges with isolation cocks and chrome plated copper pipes as hydrant station to read pressure from 0-25 kg/cm2 complete and of dial dia 150 mm.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipecoupling as required :
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft,mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation,conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.
a) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. c) SuitableHP squirell cage induction motor TEFC type suitablefor operation on 415 volts, 3 phase 50 Hz AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. d) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. e) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required
Providing, fixing, testing and commissiong of motor control centres fabricated from 16 gauges MS sheet with powder coated finish. The control panels should be comparable with H.P. of the motor as specified.
Providing and fixing motor control centres fabricated from 16 gauge M.S. sheet with Powder Coated finish. The control panels should be compatible with H.P. of the motor as under and as per spcifications with automatic star delta starters. (One separate panel to be located in the plant room).
Providing and fixing heavy duty Aluminum armored cables 1.1 KV grade including necessary support clamps at ceiling level, connection lugs and double compression glands, complete in all respects.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Supply, Installation, Testing & Commissioning of ISI marked (IS:15683) Portable fire extinguisher, of 4.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Supply, Installation, Testing & Commissioning of ISI marked (IS:2878) Portable fire extinguisher, of 22.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Supply, Installation, Testing & Commissioning of ISI marked (IS:15683) Portable fire extinguisher, of 4.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Supply, Installation, Testing & Commissioning of ISI marked (IS:2878) Portable fire extinguisher, of 22.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Check list farwarding.pdf
NIT • 1.76 MB
Letter no 7292 E-in- C bcd.pdf
NIT • 0.64 MB
Letter No 3183 Dated 3-6-2020.pdf
NIT • 1.08 MB
Annex.1-Joint Venture Guidelines.pdf
NIT • 1.20 MB
Letter no 7291 E-in-C bcd.pdf
NIT • 0.55 MB
E NIT No 04 & CORRIGENDUM.pdf
NIT • 3.75 MB
SBD_NIT 04.doc
NIT • 0.86 MB
BOQ RAMGADH CHAWK.xlsx
NIT • 0.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].