| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹90.5 LAccepted-AOC NEAR VILLAGE PANCHAYAT SANCORDEM GOA | NORTH GOA | GOA | 403402 | 1st | Accepted-AOC 1stlowestbidder | |
| 2 | 2nd₹94.7 L+₹4.2 L (4.68%)Rejected-Finance | 2nd | Rejected-Finance 2nd lowest | |
| 3 | 3rd₹99.3 L+₹8.8 L (9.73%)Rejected-Finance AMEYA PLOT NO 8 KURTARKAR NAGARI SHANTINAGAR PONDA | NORTH GOA | GOA | 403001 | 3rd | Rejected-Finance 3rd lowest | |
| 4 | 4th₹1.0 Cr+₹11.1 L (12.2%)Rejected-Finance GOA | NORTH GOA | GOA | 403524 | 4th | Rejected-Finance 4th lowest |
Tender Value
₹94.8 L
EMD Value
₹1.9 L
Closing Date
6 Feb 2025, 3:00 pmClosed
Executive Engineer
4th floor Paryatan Bhavan Panaji Goa
Upgradation/Beautification and Illumination of Shree Devi Shantadurga Alias Sateri Devasthan, Deulmol, Bolkarnem, Sancordem, Dharbandora - Goa (Re-tender)
2025_GTDCL_19479_1
GTDC/PC/EE-(S)/2024-25/e-54
Open Tender
Civil Works
Item Rate
270 days
4th Floor Paryatan Bhavan Patto Panaji
Please refer Tender documents.
7 documents required · 7 mandatory
₹8,000
₹1.9 L
28 Mar 2025
17 Jan 2025
7 Feb 2025
17 Jan 2025
6 Feb 2025
17 Jan 2025
Amount
CIVIL WORKS
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : a) All kinds of soil
b)All types of Ordinary rock including all types of laterite rock, blasting prohibited
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement.
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. Extra for laterite masonry in all sizes in superstructure from floor I level upto floor V level.
Providing & laying cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded granitic or basaltic stone aggrt. 40 mm. nominal size) excluding cost of centering, shuttering and finishing in: a) All works upto plinth level
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) a)All works upto plinth level
b)In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. upto floor five level
c)In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level
Reinforced cement concrete work 1:1½:3 (1 cement: 1½ coarse sand: 3 granitic or basaltic stone aggreate 20mm nominal size excluding plastering and cost of centering, shuttering & reinforcement, in sloping or battering surface (slabs, beams, louvers, etc) (i) Where inclination to the horizontal does not exceed 30°
Centering & shuttering including Strutting, Propping & removal of forms for : i) Foundations, Footings, Bases for columns
iii)Columns, Piers, Pillars, Aburments, Posts and struts (square rectangle polygon in plan)
iv)Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth
xiii) Suspended floors, roofs landings, shelves & their supports
Centering & shuttering including Strutting, Propping & removal of forms for sloping or battering surface (slabs, beams, louvers, etc) including folded plates (i) Where inclination to the horizontal does not exceed 30° requiring shuttering on the underside onlyExtra to be added for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de- shuttering and de-centering at all levels, over a height of 3.5m, for every additional height of 1m or part thereof. (Plan area to be measured) Suspended floors, roofs, landings, beams and balconies (plan area to be measured)
Centering & shuttering including Strutting, Propping & removal of forms for sloping or battering surface (slabs, beams, louvers, etc) including folded plates (iv) Cornices & Mouldings
Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
Providing and fixing in position S.S. hand rail in main stair case, and landing as per approved design shown in the drawing including bending handrail pipe to proper shape in curves with specials, etc. complete.
Providing and laying jet black mirror polish granite flooring and dado over 20mm thick base of cement mortar 1:4 laid over and jointed with cement slurry including rubbling complete Granitic slab (jet blck with mirror polish) 20 mm thick add q0% wastage 1.00
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer : Flamed finish granite stone slab. a) jet black
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqm a)jet black
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. a) 60 mm thick in all colours except grey
b) 60 mm thick in Grey colour
12mm cement plaster 1:4 (1 cement : 4 fine sand)
6mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand)
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.
Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.
Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete.
Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Removing dry or oil bound distemper by scrapping sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead.
Dismantling the tile work in floors and roofs laid in cement including stacking of materials within 50 meters lead for thickness of tiles 10mm to 25mm.
Demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead.
Dismantling asbestos sheet roofing including ridges, hips valley and gutters and stacking the material within 50 meters lead.
Dismantling wood work of area below 40 sq.cm. wrought framed and fixed in frames, other frames and trusses including stacking of material within 50 mts. Lead
Disposal of unserviceable material such as buiding rubbish,wood,earth excavated rock etc for all leads and lifts beyond 50m, Upto 5km
Providing water proofing treatment over the new R.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab and laying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m.
Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed: a)110 mm dia
Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating.
ELECTRICAL WORKS
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit ( medium)of appropriate size as required. (b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)
(c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group A -- with Cat A Modular Accessories
Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( vmedium) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required. A) CAT A
Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 A and 5/6 A modular socket outlet modular socket outlet and 15/16 A modular switch connection painting etc. as required. A) CAT A
Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator). f) 8 way double door Cat A
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. b) DP, Cat A
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. b) DP, Cat A
Supplying & erecting LED 20W tube light fitting (4 feet), 5700K, with CRCA housing, heat sink, with industrial grade heavy duty driver complete Havels Cat stout mini 1200bs 40w led 865 Make Philips / Wipro cat no LL24-541-XXX-57-CD (including lamp)
Supply and erecting of 48 inch ( 1200mm sweep) ceiling fan, double ball bearing type, , complete with all accessories. (b) Cat B
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (a) Cat A
Supply and erecting fan hook box ( 100 mm diameter or equivalent square size, 75mm deep) fabricated out of 16 SWG sheet steel with 10 m round bar hook bounded to RCC steel upto 50 mm length protruding on each side of the box, including painting with 2 coats of red oxide, complete as required.
Supply of Architectural designed Pole of 3mtr Height Post top pole made of galvanised iron sections of 114mm & 60mm dia. This architecturally designed pole is structurally sound. Windspeed considered in design 50m/s, IS875:PART 3:1987•Material for tubes steel of grade YST210.•Material for base plate steel of grade E250 to IS2062; 2011. The pole will be provided with an inbuilt junction box to fix 32Amp Connectors & 6Amp MCB inside the cut window of the bottom pipe the inbuilt box should have a flush door of suitable size with Allenkey locking on bothside. The Decorative pole will be mounted on a square base plate of size 200X200mm having 10mm thickness. The base plate shall have 4 hole suitable for M16/450 foundation bolts ensuring firm grouting in the specially designed RCC foundation. The galvanized zinc coat should not be less than 65+/ 10microns. The Galvanised pole should be painted in 3layer coating (Coating thickness should not be than 80microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy zinc primer & 3rd final layer with PU Paint with overall 100 +/- 10 microns. Including Foundation bolts, FRP connectors and MCB Preferred Make:- Suncity, K-lite, Reteck, Havells, La-Luminire as required and directed by the engineer incharge
Supply of 40W decorative luminaire made of spun aluminium body withpressure die-cast heat management (PDCHM) and the IP65 opticalcompartment with high power LED/s is comprised of a deep drawnchemically polished and co-extruded, thermoformed polycarbonate protectorstabilized agent UV rays suitable for 50W LED. Fitting shall be Post topmounting type fixture. System Wattage: 50W LED, Protection class:IP65,Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency:50-60Hz, Operating Voltage:1200- 277Vac, Operating Temperature: 0deg to+50deg C, single phase ac supply.● light Source : Bridegelux, LEDLumens:6000lm, CRI(Ra):>80, LED Colour Temperature: 4000K, LifeSpan:>59,000 Hours,, ● Physical Body: Die cast Aluminium Base, BodySpun Aluminium, Diffuser: Convex Type Translucent / V TranslucentPolycarbonate glass, Mounting: Suitable for 48mm OD Pipe, Finish: PowderCoated Black, ●Driver Power Factor:>0.95, THD:<7.8%,Surge Protection:4KV, Efficiency:>87%. Fitting should have inbuilt driver with efficiency >0.9and having surge protection device of 4KVA and external surge protectiondevice of 10KVA make Philips. LED's of Osram & Driver to be of makePhilips. LM79-2019 report to be provided.(Preferred Make:- Havells,Suncity,K-lite, Reyteck, La Luminire as required and directed by engineer incharge)
Supply of 3 core unarmoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 2) 3 Core 2.5 sq.mm
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 1) 3 1/2 Core 25 sq.mm
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 4) 4 Core 10 sq.mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. (a) In soily strata
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (1) 3 1/2 x 25 Sq. mm.
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (1) 3 x 1.5/2.5 Sq. mm.
Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark,of approved brands, including accessories and providing masonry enclosure with CI/RCC cover having locking /lifting arrangement and watering pipe etc. with charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately). (b) In rocky strata
Supplying and laying 25 mm x 5 mm GI strip in 40 mm dia GI pipe from earth electrode as required
Providing and laying earth connection from earth lectrode with 6 SWG dia GI wire in 15 mm dia GI pipe from earth electrode as required
MICHAEL AND MICHAEL CONSTRUCTIONS (BID ID -42953)
SHIVAM INFRATECH (BID ID -43372)
D K BHOMKAR (BID ID -43063)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .