Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 90 A 2ND FLOOR MAIN ROAD AMRIT PURI B REGD EAST OF KAILASH SOUTH DELHI 110065 | DELHI | SOUTH DELHI | DELHI | 110065 | Accepted-Technical ok |
| 2 | Accepted-Technical | Accepted-Technical ok |
| 3 | Not Admitted-Fee/PreQual/Technical 1203 I SQUARE CORPORATE PARK SCIENCE CITY ROAD SOLA AHMEDABAD GUJARAT 380060 | AHMADABAD | GUJARAT | 380060 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
Closing Date
11 Aug 2026, 9:00 amClosed
Managing Director
meerut road
onlinestackmonitoringsystem
2026_HBC_538029_1
onlinestackmonitoringsystem
Open Tender
Miscellaneous Goods
Supply
60 days
karnal
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
11 Aug 2026
1 Aug 2026
11 Aug 2026
1 Aug 2026
11 Aug 2026
1 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Upgrade the existing online stack monitoring system | |||||
| 1.1 | {INSTRUMENTATION/ INSTRUMENT STORE A/C}
SENSOR FOR CONTINUOUS STACK EMISSION MONITORING SYSTEM (CSEMS)
(IM0176)
Model – System DUSTHUNTER SB30/SP30,
Measuring Parameter – SPM, Measured Principle – Forward Light Scattering, Measuring Range – (0 7.5/15/45/75/150/225/375/1,000/3,000
mg/m3), Unit – mg/m3, mg/ Nm3, Process Temp. – Up to 200°C, Ambient Temp. Range – 0°C ... +60°C, Temp. – Up to 200°C, Temp. Measurement – Required for Normalization (mg/nm3), Pressure Measurement – Required for Normalization, Process Gas Humidity – Non-Condensing/Condensing as Per Site, Degree of Protection – Min Requirement IP66, Approval – NPL with Verification Certificate & Long-Life Validity, International Certification – TUV Germany, DIN EN 15267-1 (2009), DIN-EN 15267-2 (2009), DIN EN
15859 (2010), DIN EN 14181 (2014), Product Safety – CE, Accurate Dust Measurement – Yes,
DO (RS 485 MODBUS) – Yes, AO (4-20 mA) – Yes, Auto Zero Facility – Yes, Auto Span Facility – Yes, Data Connectivity to CPCB – Yes, Data Connectivity to HSPCB – Yes, Weatherproof Panel – Yes,
Display Unit – Yes, Touch Screen,
Make- Endress & Hauser
Note-
We require this NPL Certified Sensor for Continuous Stack Emission Monitoring System with installation of PTZ Camera also as per CPCB guidelines.
Rates should be inclusive of installation/erection and commissioning Continuous Stack Emission Monitoring System | 1 | Nos | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.65 MB
BOQ_617199.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .