Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹32.4 LAccepted-Finance SHOAL BAY 11 SOUTH ANDAMAN | 1 | Accepted-Finance Accepted | |
| 2 | 2₹34.2 L+₹1.7 L (5.29%)Accepted-Finance | 2 | Accepted-Finance Accepted | |
| 3 | 3₹34.7 L+₹2.3 L (7.06%)Accepted-Finance | 3 | Accepted-Finance Accepted | |
| 4 | 4₹35.0 L+₹2.6 L (7.89%)Accepted-Finance GOVT CONTRACTOR STEWARTGUNJ SOUTH ANDAMAN PIN 744107 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744107 | 4 | Accepted-Finance Accepted | |
| 5 | 5₹36.5 L+₹4.1 L (12.6%)Accepted-Finance | 5 | Accepted-Finance Accepted |
Tender Value
₹45.3 L
Closing Date
15 Sept 2022, 3:00 pmClosed
DFO, South Andaman
Divisional Forest Office South Andaman Wimberlygunj
Renovation of Forest Club at Mannarghat Range under South Andaman Division (Full Work)
2022_DFOSA_7165_1
12-4/G-MG/Forest Club/MG/387
Open Tender
Civil Works - Buildings
Works
365 days
Mannarghat
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
30 Dec 2022
31 Aug 2022
15 Sept 2022
31 Aug 2022
15 Sept 2022
1 Sept 2022
Amount
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Column. Stage steps.Verandha steps
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto1.5m. Floor. Stage area
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). Column, Flooring, Enterance Steps bed, Steps bed, Plinth wall (long side), Short side, Stage front side.
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). Stage front side, Stage side steps treads, Rise, Enterance Steps treads.
Providing and fixing up to floor five level precast cement concrete hollow block including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). Long wall. Front& back wall.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Providing and laying CC surface drain 1:4:8 of size 23x23cm.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). Short column, Teripozail portion.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). Column, Plinth beam (long side), Short side, Lintel beam, Tie beam.
Centring and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. Short column, Teripozail portion, Short column
Lintels, beams, plinth beams, girders, bressumers and cantilevers. Column, Plinth beam (long side), Short side, Lintel beam, Tie beam.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Cold twisted bars, Foundation jalli both ways. (10 mm-Main bar, Lintel beam), (12 mm- Plinth beam (Long side), Short side, Tie beam, column), (8 mm- Plinth beam (long side), short side, lintel beam tie beam, column
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Kiln seasoned and chemically treated Superior Hard Wood Cat-II. Door ,Window & ventilator Frame. Eaves board.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws excluding, panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Kiln seasoned and chemically treated Hollock wood. 30 mm thick shutters. D, D1.
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Kiln seasoned and chemically treated Hollock wood. 30 mm thick. W, V
Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and cleresterory window shutters. (Area of openin for glass panes excludin portion inside rebate shall be measured). 5.5 mm thick instead of 4 mm thick. W & V.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 300x16 mm
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 200x10 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 150x10 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 100 mm
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. (65mm Ø MS Pipe- Tie, Main Rafter), (50mm Ø MS Pipe - Purlin, 40x6mm thick Mukree, 40x6mm thick Gutter flat, 8mm thick purlin cleat main, 8mm thick hip side purlin cleat, 8mm thick shou(Gusset ) plate), 25 mm dia pipe, (Bolt and nuts - Purlins bolt &nuts 16mmx2''length, Connection bolt &nuts 20mmx2"long)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while etc. Main building, Hip side
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 m. Ridges plain (500 - 600mm).
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. 75 mm diameter.
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. 110 mm diameter.
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expan. Single tee without door. 110x110x110 mm.
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expan. Bend 87.5°. 110 mm bend.
Providing and fixing 15 cm wide 45 cm over all semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 0.80mm thick with zinc coating not less than 275gm/m²
12 mm cement plaster of mix : 1:4 (1 cement : 4 coarse sand), Front& back wall.
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work. Front& back wall.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer. Front& back wall
Applying priming coat : With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood), Door ,Window & ventilator Frame, Eaves board. D, D1, W, V.
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Whole Electrical work
Whole Plumbing work
T ABDUL BASHEER
R SELVAM
N H CONSTRUCTION
A P HUSAINAR
M/S HABIB CONSTRUCTION
Haneefa Constructions
Abdul Gafoor
A SAMSUDDIN
A Palani
Kathir Marketing Services
tech_eval.pdf
fin_eval.pdf
finance_7665.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .