Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹36.3 L+₹1.2 L (3.49%)Rejected-Finance CHANDPURA TIKAMGARH DIST TIKAMGARH MP | TIKAMGARH | TIKAMGARH | MADHYA PRADESH | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹39.7 L+₹4.7 L (13.3%)Rejected-Finance | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder | |
| 4 | L4₹45.1 L+₹10.0 L (28.6%)Rejected-Finance | L4 | Rejected-Finance Rejected being 4th Lowest Bidder | |
| 5 | L5₹46.0 L+₹10.9 L (31.2%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L5 | Rejected-Finance Rejected being 5th Lowest Bidder |
Tender Value
₹50.4 L
EMD Value
₹1.0 L
Closing Date
24 Feb 2020, 6:00 pmClosed
CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
SPECIAL REPAIRS TO WATER SUPPLY PUMP HOUSE NO. 01 AND ITS FILTRATION PLANTS AT MILITARY STATION FARIDKOT
2019_MES_284737_1
CA NO. CWE SGNR - 50 OF 2019-20
Open Tender
Civil Works - Others
Item Rate
120 days
GE FARIDKOT
Class D
Category a(ii)
10 documents required · 10 mandatory
₹1,000
GE FARIDKOT
₹1.0 L
Yes
14 Mar 2020
27 Jan 2020
26 Feb 2020
27 Jan 2020
24 Feb 2020
17 Feb 2020
Amount
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed by Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles(if any) to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge
S&F Glazed ceramic tiles (coloured tiles) in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick backing plaster in CM 1:4 etc complete all as specified and directed by Engineer-in-Charge
S&F Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles 15mm thick screed bed or bedding layer CM 1:4 for laying finishes, complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster on brick or stone wall etc. including raking out of joints, hacking for keys and scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering 15 mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement and preparation of newly plastered surface of wall and applying three coats of white wash etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering 15 mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement including preparation of newly plastered or unplastered surfaces and applying two coat of cement base paint over one coat of primer complete all as specified and directed by Engineer-in-Charge
M&L for rendering 10 mm thick in cement plaster 1:3 on ceiling finished even and smooth without using extra cement including preparation of new surfaces plastered or unplastered and applying three coats of white wash on ceiling etc complete all as specified and directed by Engineer-in-Charge
M&L for cement plaster and rendering 15mm thick rough cast plaster in cement mortar (1:4) on fair of brick or concrete surface and applying two coat cement base paint over one coat of primer complete all as specified and directed by Engineer-in-Charge
M&L for hardcore of broken brick aggregate gauge not exceeding 63mm deposited spread and leveled in layers not exceeding 15 Cm thick watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge
Dismantling wrought iron on Mild steel work of any description etc complete all as specified and directed by Engineer-in-Charge
M&L for mild steel framed work of E-165(Fe-290) as in grills/guard bars shouldered with steel windows/ventilators frames,Cooler Stand, Ladder etc. including red oxide primer coat complete all as specified and directed by Engineer-in-Charge
M&L for machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade, with grey cement and pigment, complete all as specified and directed by Engineer-in-Charge
M&L for machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 100 mm thickness, M-50 Grade, with grey cement and pigment, complete all as specified and directed by Engineer-in-Charge
Providing factory made precast cement concrete solid block type B1, 1:2:4 (20mm graded aggregate) as in kerb stone of any size/thickness setting in cement mortar 1:4 for path edgings etc, embedded in positon including all necessary excavation, tamping ground arround blocks and removal of rubbish/surplus soil etc. complete all as specified and directed by Engineer-in-Charge
Preparation of new concrete / plastered surface of any description, over 10cm width or girth and applying two coats of plastic emulsion paint including priming paints complete all as specified and directed by Engineer-in-Charge
S&F factory made box type steel window with side hung shutters including box type hinges with steel handle and 2 Nos 150mm long mild steel tower bolt,fixing lugs etc complete with glazing bars dovetailed or welded complete all as specified and directed by Engineer-in-Charge
S&F factory made box type steel window with side hung shutters including box type hinges with steel handle and 2 Nos 150mm long mild steel tower bolt,fixing lugs etc complete without glazing bars dovetailed or welded complete all as specified and directed by Engineer-in-Charge
Taking down of chowkats or frames n.exc 1.5 Sqm each with shutters (without taking of shutters from the frames) complete all as specified and directed by Engineer-in-Charge
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, manhole cover ,sub base & mass concrete complete all as specified and directed by Engineer-in-Charge
M&L for preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (Un-reinforced) in ground floor /First floor and paving n.exc 15 cm thick (below or above ground level) complete all as specified and directed by Engineer-in-Charge
M&L for cement concrete 50mm thick type C-1 (1:3:6) 20 mm graded stone agg) as in plinth protection/path finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge
M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in benching for manholes.bands,coping,bed plates including slightly rounded or chamfered angles including necessary formwork complete all as specified and directed by Engineer-in-Charge
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed by Engineer-in-Charge
M&L for brick work with fly ash bricks (old size bricks) straight or curved on plan exceeding 6m mean radius with old size bricks in wall built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge
All as per ser item No. 27 here-in-before but except bricks complete all as specified and directed by Engineer-in-Charge
Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as Switches, sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface complete all as specified and directed by Engineer-in-Charge
Taking down unserviceable main switches and MCB distribution boards single phase complete all as specified and directed by Engineer-in-Charge
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core including PVC rigid concealed conduit medium grade of suitable size (not less than 20mm dia) with all accessories such as bend reducers / MS hooks, MS junction boxes 2mm thick galvanized steel pressed sunken terminal boxes of suitable sizes for mounting of switches sockets, fan regulators etc covered with 2.8mm thick plastic laminate (Hylem / Anchor) top cover including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated stranded (Green colour) connected to common earth point dolly for one light point / call bell point / fan point to be controlled by one number one way point switch complete all as specified and directed by Engineer-in-Charge
Switch socket combination 5 Pin 5 Amps 230 Volts point controlled by one switch and wiring with 1.5 Sqmm PVC unsheathed copper conductor cable 1.5 Sqmm PVC insulated earth wire on independent board complete all as specified and directed by Engineer-in-Charge
All as per item No. 32 here-in-before but on same board complete all as specified and directed by Engineer-in-Charge
Switch socket combination (multi purposes) 6 Pin 15 Amps point to be controlled by one switch & wiring with 2.5 Sqmm PVC- unsheathed copper conductor cable 2.5 Sqmm PVC insulated earth wire on independent board complete all as specified and directed by Engineer-in-Charge
S&F switch Piano type single pole one way 5 Amp,230 VAC supply complete all as specified and directed by Engineer-in-Charge
S&F socket two in one ,3 Pin 5 Amps 230 VAC supply complete all as specified and directed by Engineer-in-Charge
S&F switch Piano type single pole one way 15 Amp on laminated sheet top cover complete to all as spd (Sheet top cover including in point wiring) complete all as specified and directed by Engineer-in-Charge
S&F socket Pinao type 6 Pin 16 Amp, 230 V AC complete all as specified and directed by Engineer-in-Charge
S&F Ceiling rose, three terminals with bakalite 20mm back plate complete all as specified and directed by Engineer-in-Charge
S&F fan regulator electronic socket type 5 speed for ceiling fan 1200/1400 mm sweep complete all as specified and directed by Engineer-in-Charge
Supply & fixing Lamp holder PVC /Polycarbonate type with back plate Suitable for batten fittings and including LED lamp 9 watt, complete all as specified and directed by Engineer-in-Charge
S&F in replacement of LED tube light with fitting 1x 18/20 watt (4 feet long) 230 volt,6500˚K temp, 0.9 Power factor with environment friendly, complete all as specified and directed by Engineer-in-Charge
S&F in replacement of LED Building security light 25 Watt Luminaries comprising of epoxy powder coated housing,enclosed with glass cover including 40mm GI bracket with GI F.I. pipe, cable 1.5 Sqmm and fixing arragement etc. complete all as specified and directed by Engineer-in-Charge. Make : Bajaj Cat Part No.169821BCLST 25 W LED or Equievalent Havells / Crompton Greaves
S&F as in replacement MCB distribution board double Door of sheet metal Single pole and neutral 8 way with 200 amps rated bus bar 240 volts duly recess in ground / wall and making good to disturbed surfaces complete all as specified and directed by Engineer-in-Charge
S&F MCB, SPN 240 volt 32 Amp 10 KA 'B' curve complete all as specified and directed by Engineer-in-Charge
S&F MCB single Pole 240 Volts 6 to 40 Amp 10 KA 'B' curve complete all as specified and directed by Engineer-in-Charge
S & F replacement of MCB distribution board double Door of sheet metal TPN 6 way with 415 Volts complete with and including MCCB 63 Amps,16KA complete all as specified and directed by Engineer-in-Charge. Make: Havells / HPL / Legrand
Taking down old unserviceable sub main wiring of any size from wall and conduit complete all as specified and directed by Engineer-in-Charge
M&L for Sub main wiring with two single core PVC FRLS insulated stranded copper conductor cable of size 6 Sqmm and PVC insulated FR-copper wire 6 sqmm for continuous earth wire drawn into existing concealed conduit complete all as specified and directed by Engineer-in-Charge Note : All 3 Runs of single / wire shall be measured as 1 RM in Mtr.
Supply and laying in replacement, XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with stranded aluminium conductor 1100 volts grade confirming to IS-1554 cross sectional area 16 Sqmm 4 core including thimbles/lugs complete with & including passing through pipe along wall, under road crossing / Nallah / Under floor etc complete all as specified and directed by Engineer-in-Charge (Note:-Earth work, sand cushioning, GI Pipe protection & brick protection to be measured and paid separately)
Protection to cable with one layer of bricks laid flat across the cable using old size sub class 'B' bricks complete all as specified and directed by Engineer-in-Charge
M & L Sand cushioning for LT cable protection in trenches with dry coarse sand to under ground cable 23cm thick, 8cm thick below the cable and 15cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge
Steel tubes 40mm bore light grade galvanised for cable protection fixed to poles/laid under floor/under road crossing complete with all fittings complete all as specified and directed by Engineer-in-Charge
Excavation in trenches, not exc 1.5 mtr wide & not exc 1.5 mtr in depth for pipe line, cable trenches not exc1.5 mtr in depth & getting out in sof t /loose soil complete all as specified and directed by Engineer-in-Charge
Returning, filling in including spreading leveling, watering and well ramming in layers each not exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-Charge
Removing surplus spoil to a distance not exc 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge
M&L for MS clamp of size 40mmx3mm for holding GI pipe with pole and wall complete with nut, bolts and washer complete all as specified and directed by Engineer-in-Charge
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with top edge of earth plate at a depth not less than 1.5 Mtr below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts and washers of galvanized iron or steel and thimbles upto equipment and other end of the earth wire connected to earthing test point and protected by galvanized iron pipe light grade 20mm dia upto earthing test point / equipment fixed with 2 Nos. of mold steel clamps made out of 25mm x 3mm flat iron and preforated water pipe 20mm dia galvanized iron pipe heavy grade 2.25 Mtr long and top with socket and plug and bottom connected to earth plate by silt and two bolts / nuts / washers complete with funnel and wire mesh, PCC chamber in cement concrete (1:3:6) type C-1 and cast iron cover with frame all as shown on electrical plate No. 3 of MES Schedule Part - I of SSR-2009 complete all as specified and directed by Engineer-in-Charge. Note : (i) Outer edge of earth pit will be 1 Mtr away from the outer edge of PCC Chamber. (ii) Galvanized iron earth wire 4mm dia upto earthing test point / equipment is encluded in this item. (iii) Water pipe shall be provided in slainting position. (iv) 20mm dia galvanized iron pipe for watering shall be provided with a socket and plug and shall be 10cm above the ground level.
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type end joint complete with jointing material and accessories suitable for3 core XLPE armoured aluminum conductor cable of size120 to 185 Sqmm complete all as specified and directed by Engineer-in-Charge.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type end joint complete with jointing material and accessories suitable for3 core XLPE armoured aluminum conductor cable of size 120 to 185 Sqmm complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement air break gang operated switch, triple pole, 11 KV (outdoor type) mechanically operated, suitable for horizontal or vertical mounting fixed type complete with 12 insulators and steel frame, with operating mechanism worked from ground level with fixed contacts of phosphorous bronze and moving control of copper, for current rating upto 200 Amps including GI pipe heavy duty of required size and with locking arrangement including Godrej (Freedom) 65mm pad lock with two keys with fuse mounts, fuse carriers and HT fuse elements having 400 amp rating suitable for HT 11 KV, 50 Hz, AC supply including necessary electric connections complete and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of ACB 4 Pole, 415 volts, with Thermal magnetic Release (Manual Fixed type)of capacity 630 Amps complete all as specified and directed by Engineer-in-Charge
Supply, fixing in replacement, LED street light fitting of 45 Watt including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -65 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 Volts, AC. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report. complete all as specified and directed by Engineer-in-Charge
Supplying and fixing cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size as indicated or directed complete all as specified and directed by Engineer-in-Charge. Note :Exposed steel surface shall be treated with two coats of aluminium paint over a coat of red oxide primer and unexposed surface of steel sections shall be applied one coat of red oxide primer.
M & L for Top up with fresh transformer oil in transformer in-site after filtration / dehydration with minium dielectric strength of 55 KV complete complete all as specified and directed by Engineer-in-Charge
Dehydration/filtration of transformers oil of existing transformers (out door/indoor , step up/step down),/Voltage stabilizers at site by means of oil dehydration machine having arrangement for heating to remove the moisture silt/sludge and wastage removing arrangement etc to make the oil fit for use in accordance with IS-1886 to achieve minimum dielectric strength of 42 KV by continoues process of dehydration complete including testing at standard gap of 2mm by oil testing machine complete all as specified and directed by Engineer-in-Charge. Note :- (i)Electricity for running dehydration machine & testing shall be provided by the deptt free of cost. (ii) Testing machine to be arranged by the contractor under his own arrangement.
Supply and spreading levelling, compacting 20mm graded stone aggregate under GO / DO structures, outdoor sub stations after cleaning the surface Vegetation, grain, roots etc. complete all as specified and directed by Engineer-in-Charge. 3 Note : Deduction @ 15% will be done for void for payment purpose.
Supply and fix in replacement GI pipe 25 mm bore light grade for protection of cable including provision of clamps, nuts, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directed by Engineer-in-Charge.
Material and labour for replacement of silica gel of air breather filled complete for transformer of capacity 63 to 500 KVA complete all as specified and directed by Engineer-in-Charge.
Cleaning sprinkled transformer oil, grease and all other foreign materials from external body surfaces of transformers of capacity 63 to150KVA and preparing the surface to receive paint and applying one coats of synthetic enamel paint (spray painting) including writing MES number and SM Number with white paint over black base in letters not less than 10 cms in height complete all as specified and directed by Engineer-in-Charge
All as per item No 71 here-in-before but transformers of capacity 250 and upto 500 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement post top LED 10 watt made in cast aluminum with decorative opal polycarbonate diffuser with IP65 protection complete all as specified and directed by Engineer-in-Charge.
Surface dressing not exceeding 15cm deep in soft/loose soil including cleaning of E&M installation premises, uprooting of tiny trees, bushes, beeds, grass and removing poly bags, brick bats, stone pebels debris etc. to a distance n.exc 50m complete all as specified and directed by Engineer-in-Charge.
Removal filter media (gravel ,sand etc) upto bottom of water filter bed of water capacity 20000 gallons/hour one by one ,washing media,removing sludges,mud,clay and all foregin materials,setting aside usefull media for and replacement of deterioted /distorted media with new media of various specifications complete all as specified and directed by Engineer-in-Charge (media shall be measure and paid seperately) Note: one quote of black paint in whole filter walls and pipes and Refilling and relaying of old gravel and sand media is included in item rates quoted
Supply and laying filter media of screened graded sand/gravel laid, stone gravel of size 2mm to 5 mm complete all as specified and directed by Engineer-in-Charge
All as per Item No 76 here-in-before but for size 0.5 mm to 1 mm complete all as specified and directed by Engineer-in-Charge
Supply and fixing Horizontal split casing type clear water pumping set comprising of totally enclosed fan cooled sqiirrel cage induction electric motor 100HP/75KW 3 phase ,415 volts 50Hz mounted (B3),continously rated (S1) with ambient 50 degree C, F class insulation with temp rise enclosed conforming to protection IP-55 ,horizontal foot limited to class B altitude less than 1000 m above m.s.i performance efficiency values are conforming to IS 12615:2011 or IEC 60034-30-1-2014 fitted with horizontal split casing centrifugal pump MOC: C.I Impeller ,casing CI, shaft & sleeve SS suitable for 5820 LPM @50 METER head both directly coupledalong with coupling with MS common base frame complete all as specified and directed by Engineer-in-Charge
Supply and Fixing floating valves of conical shape of approx length 15 feet made of iron sheet of suitable size and ring type system which is attched with sluice valves of size 300mm in sedimentation tank of capacity 38 lakh gallon complete all as specified and directed by Engineer-in-Charge. NOTE Contractor will provide above item as per site requirement.
Supply only PVC submersible cable of copper conductor 50 sqmm 3 core suitable for 75/100 HP motors complete all as specified and directed by Engineer-in-Charge
Supply and fixing wooden block(Shisham) type of dimension ( 3.5 feet x 0.5 feet x 0.125 feet) fix on above fluculators of water supply instalations complete all as specified and directed by Engineer-in-Charge
Supply and laying CI Pipes of size 80mm with spigot and socket ends centrifugally cast, class LA in any trenches complete all as specified and directed by Engineer-in-Charge
Supply & laying Ductile Iron pipe ( K-7) with spigot & socketed ends class LA rubber tightened joints type centrifugally cast of size 100mm dia complete all as specified and directed by Engineer-in-Charge
S&F in replacement of sluice valve class PN-1.6, IS 14846 with brass spindle, flanged end of size 100mm bore including joint with rubber or fiber board gasket, nut bolts washers as per existing specification and body shape for Over Head tanks inlet & outlet pipes complete all as specified and directed by Engineer-in-Charge
S&F in replacement of sluice valve class PN-1.6, IS 14846 with brass spindle, flanged end of size 80mm bore including joint with rubber or fiber board gasket, nut bolts washers as per existing specification and body shape for Over Head tanks inlet & outlet pipes complete all as specified and directed by Engineer-in-Charge
Supply & laying Ductile Iron pipe ( K-7) with spigot & socketed ends class LA rubber tightened joints type centrifugally cast of size 200 mm dia complete all as specified and directed by Engineer-in-Charge
Supply & laying Ductile Iron pipe ( K-9) with spigot & socketed ends class LA rubber tightened joints type centrifugally cast of size 300 mm dia complete all as specified and directed by Engineer-in-Charge
S&F in replacement of sluice valve class PN-1.6 14846 ISI marked with brass spindle, flanged end of size 300mm bore including joint with rubber or fiber board gasket, nut bolts washers as per existing specification and body shape complete all as specified and directed by Engineer-in-Charge
S&F in replacement of sluice valve class PN-1.6, IS 14846 marked with brass spindle, flanged end of size 200mm bore including joint with rubber or fiber board gasket, nut bolts washers as per existing specification and body shape complete all as specified and directed by Engineer-in-Charge
Construction of valve pit of size 140cmx140cmx120cm(Type B) OF brick machinary including cover of MS sheet 3.15 thick and angle iron 40mmx40mmx6mm with hinges ,handle,and locking arrangement including painting with two coat of synthetic enamelled paint over a coat of red oxide and grouting to PCC concrete 1:3:6 including necessary earthwork complete all as specified and directed by Engineer-in-Charge.
M&L for DI fitting for spigot & socket pipes, bends, tapers tee pieces ,caps & plugs up to 300 mm bore of pipe complete all as specified and directed by Engineer-in-Charge -------------------------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,27,516.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 28 & 29(R) (Schedule of Credit) of Tender document
POOJA CONSTRUCTION COMPANY
M/s Balvinder Singh Engineer and Contractors
M/s Surjit Singh and bros
SWARN SINGH AND CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .