| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.8 LAccepted-AOC M 18 HOUSING BOARD UNIT MADAYANKUTTAI POST METTUR DAM 636 452 | METTUR DAM | SALEM | TAMIL NADU | 636452 | ₹17.8 L Quoted ₹18.9 L | 1 | Accepted-AOC L1 |
| 2 | 2₹22.1 LRejected-AOC 36 MAADI LINE SALEM CAMP METTUR DAM 636456 | METTUR DAM | SALEM | TAMIL NADU | 636456 | ₹22.1 L | 2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | SabhariAndCo L2 | THIAGARAJAN ENGINEERING CONTRACTOR L1 |
|---|---|---|---|---|---|
| 1.00 | Charges for cutting and removal of heavily eroded flue gas duct plates (Multilayer) from the parent plate and transporting of scrap to Central Stores/M.T.P.S-I. | 320 | m2 | 1,500 ₹4.8 L | 1,300 ₹4.2 L |
| 2.00 | Labour charges for welding eroded initial welding joints in the flue gas duct below 2 metre. | 500 | mtr. | 350 ₹1.8 L | 250 ₹1.3 L |
| 3.00 | Labour charges for welding eroded initial welding joints in the flue gas duct above 2 metre. | 500 | mtr. | 400 ₹2 L | 300 ₹1.5 L |
| 4.00 | Charges for transporting of 6mm M.S/ Checkered plates from Central Stores/ MTPS-I. to Boiler area, cutting into required size, leading, lifting, positioning on the eroded portions below 1.5 m of the flue gas duct and welding the same. | 140 | m2 | 2,300 ₹3.2 L | 2,000 ₹2.8 L |
| 5.00 | Charges for transporting of 6mm M.S./ Checkered plates from Central Stores/ MTPS-I. to Boiler area, cutting into required size, leading, lifting, positioning on the eroded portions above 1.5 metres side wall portions of the flue gas ducts and welding the same. | 120 | m2 | 2,800 ₹3.4 L | 2,500 ₹3 L |
| 6.00 | Charges for transporting of 6mm M.S./ Checkered plates from Central Stores/ MTPS-I. to Boiler area, cutting into required size, leading, lifting, positioning on the eroded top portions of the flue gas ducts and welding the same. | 60 | m2 | 3,000 ₹1.8 L | 2,700 ₹1.6 L |
| 7.00 | Providing sampling points / temperature measuring points at various location of flue gas ducts | 8 | Nos. | 7,500 ₹60,000 | 6,500 ₹52,000 |
| 8.00 | Charges for cutting and removal of the eroded portion of previously patched up plates at the flow entry direction in the flue gas duct plates and transporting of scrap to Central Stores/M.T.P.S-I. | 120 | mtr. | 350 ₹42,000 | 300 ₹36,000 |
| 9.00 | Charges for removal of wear resistance plate for patch up the eroded intricate portion and re fixing the same after completing the patch up. | 20 | m2 | 1,800 ₹36,000 | 1,500 ₹30,000 |
| 10.00 | Cutting gas | 17 | set | 4,500 ₹76,500 | 4,000 ₹68,000 |
Tender Value
Refer Docs
EMD Value
₹16,300
Closing Date
17 Oct 2025, 2:00 pmClosed
Superintending Engineer /Mechanical-I/MTPS-I
Office of the Superintending Engineer / Mechanical -I Mettur Thermal Power Station- I Mettur Dam-636406
MTPS I BM Unit III AOH 2025 26 Flue Gas duct A and B sides Patch up works and other repair works between APH out let to ESP inlet
2025_EB_611088_1
CE / MTPS-I / SE / M-I / BM /OT.286/ 2025-26
Open Tender
Power/Energy Projects/Products
20 days
Mettur Thermal Power Station-I / Mettur Dam
As per the Tender Specifications
4 documents required · 4 mandatory
₹0
₹16,300
Yes
29 May 2026
3 Oct 2025
18 Oct 2025
3 Oct 2025
17 Oct 2025
3 Oct 2025
Amount
Charges for cutting and removal of heavily eroded flue gas duct plates (Multilayer) from the parent plate and transporting of scrap to Central Stores/M.T.P.S-I.
Labour charges for welding eroded initial welding joints in the flue gas duct below 2 metre.
Labour charges for welding eroded initial welding joints in the flue gas duct above 2 metre.
Charges for transporting of 6mm M.S/ Checkered plates from Central Stores/ MTPS-I. to Boiler area, cutting into required size, leading, lifting, positioning on the eroded portions below 1.5 m of the flue gas duct and welding the same.
Charges for transporting of 6mm M.S./ Checkered plates from Central Stores/ MTPS-I. to Boiler area, cutting into required size, leading, lifting, positioning on the eroded portions above 1.5 metres side wall portions of the flue gas ducts and welding the same.
Charges for transporting of 6mm M.S./ Checkered plates from Central Stores/ MTPS-I. to Boiler area, cutting into required size, leading, lifting, positioning on the eroded top portions of the flue gas ducts and welding the same.
Providing sampling points / temperature measuring points at various location of flue gas ducts
Charges for cutting and removal of the eroded portion of previously patched up plates at the flow entry direction in the flue gas duct plates and transporting of scrap to Central Stores/M.T.P.S-I.
Charges for removal of wear resistance plate for patch up the eroded intricate portion and re fixing the same after completing the patch up.
Cutting gas
MS Welding Rod
Consumables and T & Ps for item S.No.1 to 9
SabhariAndCo (BID ID -1483651)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid