Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-Finance KODBELTALA BOALIADANGA BERHAMPORE MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | L1 | Accepted-Finance ACCEPT | |
| 2 | L2₹29.9 L+₹5.1 L (20.6%)Rejected-Finance ASANSOL | ASANSOL | L2 | Rejected-Finance REJECT | |
| 3 | L3₹31.2 L+₹6.4 L (25.7%)Rejected-Finance 56C 2 BIDHAN NAGAR RD KOL 700067 W B | KOLKATA | KOLKATA | WEST BENGAL | 700067 | L3 | Rejected-Finance REJECT |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
8 Nov 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Asansol Municipal Corporation
Maintenance of Darbadanga Pump House and Sirishdanga Pump House including supplying and installation of necessary materials of Jamuria, B- I within AMC
2023_MAD_575375_12
EQ-56/WS/ENG/2023
Open Tender
Miscellaneous Works
Item Rate
1080 days
Asansol Municipal Corporation
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹20,000
6 Jan 2024
22 Sept 2023
10 Nov 2023
22 Sept 2023
8 Nov 2023
22 Sept 2023
Amount
Day to day Periodical inspection as and when required by electrical supervisor having valid supervisor's certificate of competency from directorate of Electricity (Licensing board) , govt. of west bengal or under any other state govt. of India along with pump Technician/ Supervisor. The supervisor requires to have thorough/in-depth instruction of all the electrical appliances to ascertain the healthy/ fault free operational condition of each equipment i.e For all kinds of pump-motor & its MCC panel, cable, HT VCB, ACB, OCB, Transformer, LT panel, PDB, capacitor bank, all type of valves, actuators, relays, contactors, timers, SFU including cleaning of contacts by CRC 226 spray in HT & LT panel board, cleaning of all terminal sockets and checking of healthy condition of draw out feeders all complete and also any kind of Electro mechanical works of less than Rs. 500/- agency will be done within the above fixed cost along with cleaning of jungles of pump house campous time to time all complete as per direction & satisfaction of E.I.C.
HT VCB PANNEL
Supply & installation of new CT of adequate rating incl. fitting & fixing all complete with all allied works.
Supply & installation of new PT of adequate ratingincl. fitting & fixing all complete with all allied works.
Supply & installation of vaccum bottle of adequate rating incl. fitting & fixing all complete with all allied works.
Electric Heater repairing incl. fitting & fixing all complete with all allied works.
Supply & installation of rose contact of adequate rating incl. fitting & fixing all complete with all allied works.
TRANSFORMER 750 KVA INDOOR TYPE AT SIRISH DANGA
Supply & installation of 11 KV Bush of adequate rating including fitting & fixing all complete with all allied works.
Re winding of transformer including fitting, fixing, testing, commissioning all complete including filling with Oil.
Filtering of Transformer Oil with necessary machinaries and Di-electric test of 33 kV for Transformer Oil.
Supply and installation of adequate size oil seal gasket for transformer.
Supply and filling with filtering of Transformer oil of Power oil.
Supply and filling of Silica Gel
AUTOMATIC VOLTAGE STABILIZER
Repairing of AVR with all adequate rating Contactor ,rectifier material including fitting & fixing all complete with all allied work
Rwinding of AVR with all adequate rating Contactor, rectifier material including fitting & fixing all complete with all allied work
ACB OR PDB PANNEL: ACB 1600 AMP (INCOMMER)
Repairing of Bus bar incl. fitting fixing all complete with all allied works. Like Socketing, Glanding of cable.
Supply & installation of Contact of adequate rating incl. fitting & fixing all complete with all allied works.
Replacement of old damage Voltmeter/Ammeter
Supply & Installation of HRC/HBC fuse of adequate rating material including fitting & fixing all complete with all allied work
Disconnector / Isolator Swiitch on PDB 125 Amp to 315 Amp Switch Disconnector for 45 KW & 132 KW Motor.
Supply & Installation of Isolator Switch (Disconnector switch) by dismantling old one of adequate rating including fitting & fixing all complete with all allied work
Supply & Installation of HRC/HBC fuse of adequate rating material including fitting & fixing all complete with all allied work
Repairing of Busbar including fitting fixing all complete with all allied works likesocketing glanding of cable etc
Supply & Installation of Busbar for PDB panel of adequate rating material including fitting & fixing all complete with all allied work
16A mp to 63 Amp Switch for 10 KW to 22 KW Motor Disconnector for Actuator / RTCC / Ventilation
Supply & Installation of Isolator Switch (Disconnector switch) by dismantling old one of adequate rating including fitting & fixing all complete with all allied work
Supply & Installation of HRC/HBC fuse of adequate rating material including fitting & fixing all complete with all allied work
MCC Panel for Starter of Pump For 132 KW pump Auto Transformer Starter.
Rewinding of Auto Transformer coil by dismantling of old damage coil ,including fitting and fixing all complete
Supply & Installation of Contactor of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of MCCB of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of CT coil of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of Relay of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of Timer of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of AUX of adequate rating material including fitting & fixing all complete with all allied work
MCC Panel for 22 KW to 60 KW pump Star Delta Starter
Supply & Installation of Contactor of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of MCCB of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of CT coil of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of Relay of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of Timer of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of AUX of adequate rating material including fitting & fixing all complete with all allied work
Pump Specification: 132 KW pump Discharge Capacity 454 M3 / HR Head 65 M
Supply & Installation of new Bush by dismantling old one including fitting & fixing all complete with all allied work
Supply & Installation of new Ball bearing by dismantling old one including fitting & fixing all complete with all allied work
Supply & Installation of new Roll bearing by dismantling old one including fitting & fixing all complete with all allied work
Supply & Installation of new Shaft by dismantling old one including fitting & fixing all complete with all allied work
Supplying and filling of Pump oil
30 HP to 80 HP Pump Discharge Capacity 210 M3/HR Head 39 M
Supply & Installation of new Bush by dismantling old one including fitting & fixing all complete with all allied work
Supply & Installation of new Ball bearing by dismantling old one including fitting & fixing all complete with all allied work
Supply & Installation of new Roll bearing by dismantling old one including fitting & fixing all complete with all allied work
Supply & Installation of new Shaft by dismantling old one including fitting & fixing all complete with all allied work
Supplying and filling of Pump oil
Dismantling, Cleanning, Rewinding and Heat Varnish of motor and reinstallation
132 KW MOTOR
45 KW MOTOR
22 KW MOTOR
Replacement of Bearing Housing (including all necessary materials & labour cost)
132 KW MOTOR
45 KW MOTOR
22 KW MOTOR
Replacement of Ball bearing, Housing (including all necessary materials & labour cost)
132 KW MOTOR
45 KW MOTOR
22 KW MOTOR
Repairing of motor terminal socket including all necessary items required
132 KW MOTOR
45 KW MOTOR
22 KW MOTOR
For 4 HP to 10 HP Submersible pump DOL Starter
Supply & Installation of Contactor of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of MCCB of adequate rating material including fitting & fixing all complete with all allied work
Transformer 500 KVA Indoor type
Supplying and Filling of Transformer oil.
Supply & Installation of 11 KV Bush of adequate rating including fitting & fixing all complete with all allied work.
Rewinding of coil including fitting fixing testing commissioning allied work.
Replacement of Silicagel
Power Distributiom Board 1600 Ampere (Incommer)
Supply & Installation of Isolator Switch(Disconnector switch) by dismantling old one of adequate rating including fitting & fixing all complete with all allied work.
Supply & Installation of HRC/HBC fuse of adequate rating material including fitting & fixing all complete with all allied work.
Supply & Installation of new CT of adequate rating including fitting & fixing all complete with all allied work.
Supply & Installation of new PT of adequate rating including fitting & fixing all complete with all allied work.
Supply & Installation of new Earth Fult Relay, Over Voltage Relay, Over Current Relay of adequate rating including fitting & fixing all complete with all allied work.
Supply & Installation of Isolator Switch (Disconnector switch) by dismantling old one of adequate rating including fitting & fixing all complete with all allied work.
Supply & Installation of HRC/HBC fuse of adequate rating material including fitting & fixing all complete with all allied work
Total Starter of Pump: For 110 KW VT pump Star Delta Starter
Supply & Installation of Contactor of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of MCCB of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of CT coil of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of Relay of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of Timer of adequate rating material including fitting & fixing all complete with all allied work
Supply & Installation of AUX of adequate rating material including fitting & fixing all complete with all allied work
110 KW VT pump Discharge Capacity 178 M3/HR Head 100 M current rating 186A
Supply & Installation of new Bush by dismantling old one including fitting & fixing all complete with all allied work
Supply & Installation of new Ball bearing by dismantling old one including fitting & fixing all complete with all allied work
Supply & Installation of new Roll bearing by dismantling old one including fitting & fixing all complete with all allied work
Supply & Installation of new Shaft by dismantling old one including fitting & fixing all complete with all allied work
Dismantling, Cleanning, Rewinding, and Heat Varnish of motor and reinstallation of 110 KW Motor.
Repaiiring of motor terminal socket including all necessary items required for 110 KW VT Motor.
Supplying and filling of oil for pump and motor.
For Sub Mersible Pump Motor of 5 HP to 10 HP.
Surging of strainer pipe including labour cost, fitting & fixing all materials complete with all allied work
Ground piling for pipe including labor cost,fitting & fixing all materials complete with all allied work
Cable clamping including labor cost, fitting & fixing all materials complete with all allied work
Flange leakage repairing including labor cost,fitting & fixing all materials complete with all allied work
Collumn pipe repairing including labor cost, fitting & fixing all materials complete with all allied work
Supplying and laying of GI pipe 40 mm including labor cost,fitting & fixing all materials complete with all allied work
Supplying and laying of GI pipe100 mm including labor cost,fitting & fixing all materials complete with all allied work
Extracting the Pump from river for testing including labor cost,fitting & fixing all materials complete with all allied work
Rewinding of motor coil, replacing of bush bearing, ball bearing and shaft including lowering / reinstalling the Pump to river for testing including labor cost, fitting & fixing all materials complete with all allied work
Supply and installlation of new Motor set by dismantling of old Motor Set including all necessary materials & labour cost
Supplying and filling of Pump oil
Gland Packing (including all necessary materials & labour cost)
Supply & laying of Cable incl. necessary earth work and foundation trench fitting fixing socketing glanding all complete for 1.1 KV grade 3 core cable.
Supply & laying of Cable incl. necessary earth work and foundation trench fitting fixing socketing glanding all complete for 1.1 KV grade 3.5 core cable.
Straight through Jointing of Cable by heat sink process method including supply of jointing kit and fitting fixing socketing glanding all earth cutting if necessary all complete for 1.1 KV grade 3 Core Cable.
10 Sq mm to 35 Sq mm
50 Sq mm to 95 Sq mm
120 Sq mm to 185 Sq mm
240 Sq mm to 400 sq mm
Straight through Jointing of Cable by heat sink process method including supply of jointing kit and fitting fixing socketing glanding all earth cutting if necessary all complete for 1.1 KV grade 3.5 Core Cable.
10 Sq mm to 35 Sq mm
50 Sq mm to 95 Sq mm
120 Sq mm to 185 Sq mm
240 Sq mm to 400 sq mm
Socketing of Cable by crimping method incl. supply of adequate size of socket and fitting fixing of ampere tape all complete for 1.1 KV grade 3 core cable.
10 Sq mm to 35 Sq mm
50 Sq mm to 95 Sq mm
120 Sq mm to 185 Sq mm
240 Sq mm to 400 sq mm
Socketing of Cable by crimping method incl. supply of adequate size of socket and fitting fixing of ampere tape all complete for 1.1 KV grade 3.5 core cable.
10 Sq mm to 35 Sq mm
50 Sq mm to 95 Sq mm
120 Sq mm to 185 Sq mm
240 Sq mm to 400 sq mm
Leakage repairing by saddle clamp with insert rubber of 12.5 mm thick including supply, fitting & fixing of adequate saddle clamp with necessary work like earth work, dismantling, de-watering, cutting of pipe and grinding for all types of Pipe with supply of hiring basis labour and machinaries all complete.
200 mm to 300 mm dia Pipe line
350 mm to 500 mm dia Pipe line
Leakage repairing by bolted collar including supply, fitting & fixing of of adquate bolted collar with necessary work like earth work, dismantling, de-watering, cutting of pipe and grinding for all types of pipe with supply of hiring basis labour and machinaries all complete.
200 mm dia
250 mm dia
300 mm dia
350 mm dia
400 mm dia
450 mm dia
500 mm dia
Renewing lead joint to CI pipes and specials and spun yam 'including reusing 60% of old and using 40% new lead of approved quality new span yarn and caulking the same properly including labour charges for dismantling the existing damaged portion complete as per direction of EIC by approved quality lead, spun yarn, fuel and other materials will be supplied by the agency including necessary earth work in exacavation, dewatering & back filling in same trenches as per EIC.
200 mm dia
250 mm dia
300 mm dia
350 mm dia
400 mm dia
450 mm dia
500 mm dia
Repairing of manifold line by replacing of old damaged MS pipe (8 mm to 12.5 mm thick) including supply and febricating, welding of new pipe along with earth cutting, dewatering, hiring basis hydra & JCB if required and all other items for complete the work.
200 mm dia
250 mm dia
300 mm dia
350 mm dia
400 mm dia
450 mm dia
500 mm dia
600 mm dia
Repairing of Air Valve by replacing old damage Ball including all necessary work to complete the item.
100 mm dia
150 mm dia
200 mm dia
Welding of MS pipes including necessary materails & labour cost at site.
Sluice Valve repairing by dismantling old spindle, supply of new spindle, rubber sheet and nut bolts (if required) incl. earth work, de-watering, fitting fixing all complete for all types of pipe.
100 mm to 200 mm dia
250 mm to 350 mm dia
400 mm to 500 mm dia
Sluice Valve repairing by dismantling old bush, supply of new bush rubber sheet and nut bolts (if required) incl. earth work, de-watering, fitting fixing all complete for all types of pipe.
100 mm to 200 mm dia
250 mm to 350 mm dia
400 mm to 500 mm dia
Sluice Valve repairing by dismantling old Lock nut, supply of new lock nut rubber sheet and nut bolts (if required) incl. earth work, de-watering, fitting fixing all complete for all types of pipe line.
100 mm to 200 mm dia
250 mm to 350 mm dia
400 mm to 500 mm dia
Sluice Valve gate linear repairing with supply of rubber sheet and nut bolts (if required) incl. earth work, de-watering, fitting fixing all complete for all types of pipe line.
100 mm to 200 mm dia
250 mm to 350 mm dia
400 mm to 500 mm dia
Sluice Valve Gland packing & greaseing, incl dismantling old gland packing and nut bolts (if required) incl. earth work, de-watering, fitting fixing all complete for all types of pipe line.
100 mm to 200 mm dia
250 mm to 350 mm dia
400 mm to 500 mm dia
NON-RETURN VALVE: Repairing of gate incl. fitting fixing all complete with all allied works like supply of nut-bolts, rubber sheet (if required)
100 mm dia
150 mm dia
200 mm dia
250 mm dia
Supply & installation of NRV of PN. 1.6 incl. fitting fixing all complete with all allied works like supply of nut-bolts, rubber sheet (if required)
100 mm dia
150 mm dia
200 mm dia
250 mm dia
Supply and Fixing new Post Top Light Set by replacement the old damage light including all necessary material, wireand labour required.
Repairing of inside and outside campus LED light in Pole / Wall including necessary wire and labour required.
20 watts to 60 watts
72 watts to 140 watts
160 watts to 210 watts
Supply of new outdoor type LED lights by replacing of old LED lights of campus light in Pole / Wall including necessary wire and labour required.
40 watts
60 watts
72 watts
80 watts
120 watts
140 watts
160 watts
180 watts
210 watts
Supply of new indoor type LED Tube lights by replacing of old LED Tube lights inside of pump house & other rooms of pump house including necessary wire and labour required.
22 watts
30 watts
Replacement of old LED Lamp by the new one including holder if required.
11 watts
16 watts
20 watts
30 watts
40 watts
Repairing and Replacing of AC Ceiling Fan and Exhaust Fan
Rewinding and overhauling of AC Ceiling Fan including all necessary material, labour required
Rewinding and overhauling of Exhaust Fan including all necessary material, labour required
Supply and fixing new Exhaust fan by replaceing the old damage Exhaust Fan by new one Heavy duty 60 W
A. Construction Co.
BANERJEE ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .