Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.8 LAccepted-AOC 5D 95 VRINDAVAN YOJNA RAEBARELI ROAD LUCKNOW UP 226 029 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226029 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹68.0 L+₹3.7 L (5.72%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹69.7 L+₹5.4 L (8.35%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹80.9 L+₹16.6 L (25.8%)Rejected-Finance NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹1.1 Cr+₹46.8 L (72.7%)Rejected-Finance NOT AVAILABLE | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
8 Jul 2023, 6:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR TO DAMAGE RCC STRUCTURAL MEMBER EXTERNAL AND INTERNAL PLASTER WORK SHAFT AREA RAIN WATER PIPE LINE AND OTHER MISC WORK AT RASHI AREA AND REPAIR MAINT OF CERTAIN BR WORK LIKE PLASTERING TILING JOINERY SANITARY FITTINGS AND OTHER MISC WORKS AT
2023_MES_600812_1
8285/E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class B and category a(i)
8 documents required · 8 mandatory
₹1,000
GE NW NAVY NAGAR COLABA MUMBAI
₹2.2 L
Yes
18 Aug 2023
3 Jun 2023
10 Jul 2023
3 Jun 2023
8 Jul 2023
24 Jun 2023
3 Jun 2023 - 1 Jul 2023
Amount
Taking down old existing unserviceable cement plaster loose/unsound weaken cement concrete of any description and in any position from existing external/internal surfaces of wall, roof, etc
M&L for 20 mm thick plastering in two coats 15 mm thick backing coat in CM 1:6 and 5 mm thick setting coat in CM 1:4 mixed with water proofing compound @ 2% by weight of cement on fair faces of brick work or concrete wall surfaces finished even and smooth without using extra cement and using welded mesh where required all as specified including chicken wire mesh and scaffolding, Safety net etc all complete as directed by Engr-in-Charge. (Note :- WPC to be mixed in setting coat only and shall be measured and paid separately) ( Note : Chicken wire mess rate including )
M&L for rendering 15mm thick in CM 1:6 on other than fair faces of bricks work or concrete finished even and smooth without using extra cement.
M&L for 05 mm thick plastering in CM 1:3 on concrete surface on ceiling finished even and smooth all specified & as directed.
Supply only integral water proofing compound of approved ISI make.
M&L for CI Nahani trap dia of outlet 75mm fixed in repairs including jointing to waste pipe in runlead fixed in cement concrete type B 1 (1:2:4).
S&F PTMT grating doom over Nahani trap and floor trap of 100mm Dia (Minimum weight 25 gms)
Taking down CI soil/waste/vent/rain water pipes including all fittings like shoes bends swan necks etc of any dia all as specified and directed.
S & F CI soil/waste/vent pipe in any length with ears 100mm bore (sand cast) in any length with cement joints fixed to walls complete all as specified directed.
S & F CI soil/waste/vent pipe in any length with ears 75mm bore (sand cast) in any length with cement joints fixed to walls complete all as specified directed.
S & F CI bends (any radius) for soil/waste pipes 100mm bore diminishing pieces or tapers on walls fitted with oval access door complete all as specified.
S & F CI bends (any radius) for soil/waste pipes 75mm bore diminishing pieces or tapers on walls fitted with oval access door complete all as specified.
S & F CI branch piececs single (equal or unequal) ordinary or inverted (spigot or socked type) with parallel branches for 100mm bore pipe (Y or T) all as specified and directed.
S & F CI branch piececs single (equal or unequal) ordinary or inverted (spigot or socked type) with parallel branches for 75mm bore pipe (Y or T) all as specified and directed.
Taking down PVC rain water pipes including all fittings like shoes bends swan necks etc of any dia all as specified and directed.
S&F PVC (SWR) pipes 160mm bore single socketed in any length with rubber ring joints fixed to wall
S&F PVC (SWR)bends (any radius) for rain water pipes 160 mm bore diminishing pieces or tapers on walls complete all as specified.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall
S&F PVC (SWR)bends (any radius) for rain water pipes 110 mm bore diminishing pieces or tapers on walls complete all as specified.
S&F in repair vitreous china squatting pan Orissa pattern of size 580 x 440 mm white with back inlet and integral footrest and anti syphonnage pipe including 'P' or 'S' trap and provn of lime concrete complete all as specified.
S&F in repair 10litre capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets all complete as specified and as directed.
S&F PVC connection 15mm size with PTMT nuts of length 450mm in repairs
M & L for preparation of newly plastered surfaces of walls & applying two coats of chemical waterproofing treatment(601 raincoat of Pidilite or Dr.fixit or equivalent) of approved colour on wall such as Flexcoat, Beckcoat Exshield etc or equivalent over a coat of primeseal/primers complete as per manufactures Instructions, all as directed.
M & L for preparation of old decorated surfaces of walls & applying one coat of chemical waterproofing treatment(601 raincoat of Pidilite or Dr.fixit or equivalent) of approved colour on wall such as Flexcoat, Beckcoat Exshield etc or equivalent over a coat of primeseal/primers complete as per manufactures Instructions, all as directed.
M & L for preparing newly plastered wall surface and applying two coats OBD over putty of 1 mm thickness to prepare the surface even and smooth all complete all as specified and direceted.
M&L three coats white washing on new plastered surface on ceiling including prepration of surface all as specified and directed
Removing demolished materials outside MD land to a distance exc 5Km but n exc 10Km.
M&L Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L non-skid coloured Ceramic tiles 300x300x6 to 7mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not excceding 0.11 sqm, in floors etc, set and jointed in epoxy mortar and pointed in white of coloured cement to match including 15 mm thick screed bed in CM 1:6 all as specified.
M & L Coloured glazed ceramic tiles 300 x 200 x 7mm on vertical surfaces set & jointed in neat cement slurry and pointed in white cement mixed with pigment over 12mm thick rendering as in backing coat in CM 1:4 all as specified and as directed.
M&L non-skid coloured Ceramic tiles 400x400x6 to 7mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in epoxy mortar and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 all as specified.
S&F in repair Plastic water closet seat cover, white/black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminisied hinges devices complete all as specified and directed.
S&F in repairs vitreous china wash basin white flat back 550 x 400mm , with fitting of PTMT waste coupling suitable size incl angle iron brackets with painting of brackets etc complete all as specified and directed .
S & F in repair pillar tap 15mm bore, cast copper alloy fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions.
S&F in repair Stop valves, cast copper alloy high pressure 15mm bore ISI marked with cruch or butterfly handles screwed down both side for iron pipes complete as specified and directed
S & F 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed in repairs
Supply and fix in repairs PVC corrugated waste pipe 32mm dia bore 800mm length long with couplings etc complete.
S&F in repairs Bib taps, 15mm dia cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F in repairs High density polyethylene pipes (HDPE) 40mm dia of pressure rating 6 kgf/cm2 fixed complete to wall, floors for drain out the waste water in Kitchen Sink/wash basin complete all as specified and directed.
S&F Flush pipe of polyethylene of low or high density for low level cistern.
S&F stainless steel tubular towel rail 20mm dia D type 60cm long between flanges all complete as directed.
S& F in repair vitreous china wash down water closet padestal pattern (Anglo-Indian type) white (excluding fixing bolts, flushing cistren and flush pipe) with 'P' or 'S' trap complete all as specified supplied and fixed in repairs.
S & F in repairs Aluminium wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm, cut to required size and fixed to doors,windows shutter (wooden/aluminium), with wooden beading (any size)or aluminium wire staples and removing old beading, complete all as specified and directed.
S&F 150 mm extruded aluminium handles, fabricated type anodised fixed in repairs complete all as specified and directed.
S&F 100 mm extruded aluminium handles, fabricated type anodised fixed in repairs complete all as specified and directed.
S&F 150mm aluminium anodised barrel tower bolts of extruded section fixed in repairs complete all as specified and directed.
S&F 100mm aluminium anodised barrel tower bolts of extruded section fixed in repairs complete all as specified and directed.
S&F in repairs 300 mm long aluminium alloy , anodised sliding door bolt with hasp and staple ( bolt type ) and fixing bolt and sliding bolts of extruded section or cast aluminium alloy all as specified and directed.
S&F in repairs 140 mm overall length floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor all complete as specified and as directed by Engr-in-Charge.
S&F in repairs hasp and staple safety type,mild steel, wire type, stove enamelled black including bolt to hinge plate and fixed with screws 125mm size complete all as specified and directed.
Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 sqm each all as specified and directed all as specified and directed.
All as per Item No 52 above but exc 1.5 sqm but n exc 4 sqm each all as specified and directed.
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 2omm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of fplain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles. & rails with suitable PVC sheet beading, and joined together with sovent cement, suppling & fixing in the frame at site as per specification & direction.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixing in opening as per specification & direction.
M&L machine cut Kota stone ( greenish colour, pre mirror polished) slab in one piece as in double steps cill of aluminium slding window 18 to 20 mm thick over 20 mm thick screed bed in cement mortar 1:3 complete all as specified.
M&L machine cut Kota stone ( greenish colour, pre mirror polished) slab in one piece as in lintel and and sides of aluminium sliding window 18 to 20 mm thick over 15 mm thick rendering in CM 1:3 complete all as specified and directed.
S & F powder coated anodised aluminium frame/track or shutters for windows, ventilators etc. with one or more rebates including joining cleat for fixing etc.fixed or sliding type/louvered window or ventilator without sash bar, aluminium including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws locking arrangements etc. complete all as specified and directed by Engr-in-Charge. Note: Minimum 25 micron anodisation for all aluminium sections)
M&L powder coated aluminium grill with suitable aluminium anodised frame section of ‘F’ section of size 23.4 x 15.3 x 1.4 mm thick manufactured by M/S Deco grill pattern DG-102 (80mm x 66mm aperture) all complete.
S&F 4mm thick plain sheet glass ordinary quality and glazing with aluminium and neoprene beads in square n. exc 0.5 sqm in each pane all complete.
S&F 4mm thick frosted sheet glass ordinary quality and glazing with aluminium and neoprene beads in square n. exc 0.5 sqm in each pane all complete.
S & F Aluminium wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm, cut to required size and fixed to Aluminium doors,windows shutter aluminium wire staples complete all as specified and directed.
S&F in repairs aluminium serrated finish 20mm dia curtain rod of approved pattern and shade with all fittings as per site requirement such as end block, rounded block, brackets, CP screws, rovel plug, etc. complete all as specified and directed by Engr-in-charge.
Taking down shutters of any description n exc 1 sqm each.
All as per Item No 64 above but exc 2 sqm
S&F factory made shutter 35 mm thick second class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc edges of framing, plain chamfered or rounded fitted with cut and mitred beads fo securing gauge etc suzes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) complete all as specified and directed
S&F 35 mm thick factory made Flush shutters , solid core constrution with block board core and plywood face panels, commercial type on both side complete all as specified and directed
S&F 30mm thick flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides all as specified and directed.
S & F 25mm thick block board, grade-1 quality exterior grade commercial type fixed with screws to timber frame work of width n.exc. 25 cm in shelves or built-in cupbords, almirahs and similar work with lipping patti all complet as directed by EIC.
S&F 100 mm extruded aluminium handles, fabricated type anodised fixed in repairs complete all as specified and directed.
S&F 100mm aluminium anodised barrel tower bolts of extruded section fixed in repairs complete all as specified and directed.
S&F 75mm stailess steel medium weight butt hinges complete all as specified and directed.
S&F 150 mm extruded aluminium handles, fabricated type anodised fixed in repairs complete all as specified and directed.
S&F 150mm aluminium anodised barrel tower bolts of extruded section fixed in repairs complete all as specified and directed.
S&F 300 mm long aluminium alloy , anodised sliding door bolt with hasp and staple ( bolt type ) and fixing bolt and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
S&F 140 mm overall length floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor all complete as specified and as directed by Engr-in-Charge all as specified and directed.
S&F hasp and staple safety type,mild steel, wire type, stove enamelled black including bolt to hinge plate and fixed with screws 125mm size complete all as specified and directed.
S&F 100mm size stainless steel medium weight butt hinges all as specified and directed.
M&L for two coat synthetic enamel paint over a coat pink primer on new wooden surface of any description over 10 cm width or girth not otherwise described including preparation of surface complete all as specified and directed
S & F Sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wasters, including bedding in cement mortar to dwarf walll or including fixing cantilever brackets and connecting union to pipe over all size 915mm x 460 mm bowl sie 410mm x 330 mm x 160mm complete all as specified and directed.
S&F in repair fancy type cromium plated stop valves of 15mm bore, with cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed cmplete all as specified and directed.
S&F in repair 15mm bore dia brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed cmplete all as specified and directed.
S&F in repair health faucet (ABS Body) milt steel chromium plated suitable for 15 dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position compete all as specified and directed.
Taking up or down GI tubing 15mm bore and connections all as directed.
S&F as in repairs tubing 15mm bore medium grade, galvanised, ISI marked with all fitting and fixed complete to walls and ceilings or laid in floors.
Demolition of existing treatment of any type and preparing the surface by cleaning the concrete surface with wire brush and high pressure water jet and ensure that it is free of dust, oil, grease, loose particles vegetation roots etc complete all as specified and as directed by Engineer In Charge.
Material and labour for Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) mixed with liquid water proofing compound and 1:30 slope to be maintained complete all as specified and as directed by Engineer In Charge.
Material and labour for 10mm thick rendering in CM 1:4 with mixed with liquid water proofing compound on fair faces of brick work or on concrete surfaces complete all as specified and as directed by Engineer In Charge.
Material and Labour for preparation of newly plastered/RCC surface making surface completely dry and applying primer conforming to IS 3384-1965 @ 0.30 Kg/Sqm to be applied on prepared surface till the surface is properly impreganted.water proofing treatment shall be provided with APP modified water proofing membrane 3 mm thick ( weighting not less than 3.00 Kg/Sqm on prepared suface after the primer has dried the membrane will be laid by torching to the surface as per manufacturer instruction and under strict supervisition .APP polymeric water proofing membrane shall consist of center core of 160 GSM Non Woven polyester mat protected on both side with a high quality polymeric asphaltic mix will be procted both side with thermo fusible HMHDPE film having the technical specification, laying procedure , overlap fusing methology and treatment around rain water pipe spout and tank stagging and similar location as per zonal specfication .After laying membrane apply a layer of blown biumen (conforming to IS 702) 85/25 grade @1.2 Kg/Sqm with blinding material such as sand in dry condition @ .5 to 1.00 Kg/Sqm shall be dusted over the bitumen complete all as specified and as directed by Engineer In Charge.
Material and Labour for plain cement concrete tils 30cm x 30cm x22 to 25 mm thick with grey cement and no pigment machine pressed, set jointed and pointed in neat cement slurry in roofs , including 15 mm thick screed bed or bedding layer for laying tiles in C:M 1:4 complete all as specified and as directed by Engineer In Charge.
Material and Labour for Cement concrete 1:2:4 type B-1 ( 20 mm graded crushed stone aggregate) as coping ,roof padding, in roof kerb or mud stops ,water through and like including weathering,silghtly rounded or chamfered angle and throating with necessary formwork complete all as specified and as directed by Engineer In Charge.
Chipping ,removing carefully concrete work by low impact hammer ,breaker without damaging the structure & cleaning and disposal of debris out side the premises etc. complete as directed by Engr-in-Charge. Hard concrete shopuld not be removed by force.
M & L for clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete, Applying two coats of alkaline rust converting primer FEOVERT of Krishna Conchem of Roff rust cleaner of Piddilite or Dr Fixit Rust removal or sholirust of STP Ltd. on the rebars,including cleaning the reinforcement ,wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry and applying two coats of anticorrossive treatment. Note :- Measurement on the basis of area of concrete exposed.
M/L for providing and fixing additional steel bar or stirrups of diameter in various structural elements like columns beams and foundation including drilling bending and fixing the bars with epoxy putty etc complete as directed by Engr-in-Charge
M & L for applying two coats of anticorrosive Treatment to Reinforcement by application of two coats of anti-rust protective coating in the form of Acrylic Polymer with a minium splid content to 40% solid mixed with cement in 1:1.5 proportion ( 1 part polymer and 1.5 part cement) on rebars after cleaning of rust scales with time interval of minimum 4 hours between each coat by brush as per manufacturers instruction.Anti-rust protective shall be procured from one of manufacturer given below complete all as specified and directed by Engineer-in-Charge. (Make :- Fosroc/Sika/BASF/ Krishna Conchem)
M & L for building up the profile of structural members by using latex B2 modified air cured mortar system in damaged areas (1Cement-3 part graded cleaned pre-packed river sand 10% latex mortar by weight of cement-0.5 w/c ratio) upto 20 mm to 40 mm thickness including leveling profiling and removing and cleaning existing vegetation growth in structural and Non structural items all complete etc. all complete as directed by Engr-in-Charge. (Make :- Fosroc/Sika/BASF/Krishna Conchem)
M & L for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete all complete as directed by Engr-in-Charge.
M & L for repairing of shrinkage of structure by dirlling hole in structures using up to a depth of 15 mm and 18 mm dia, removing dust, etc by vacuum cleaner and blowers, providing and fixing of heavy grade GI pipe nipple 15 mm dia 100 mm long @ 1 mtr c/c in both direction and injection of high strength polymenr base injection grout with flexural strength of minimum 45 MPa, Tensile strength of 26 MPa in 7 days and compressive strength of minimum 50 MPa in 1 day up to 80 MPa in 7 days giving minimum pot life of 1 hr@20C and closing ends nipple epoxy putty/silica jelly after injecting the chemicals mised with cement slurry.
Material and labour for providing and fixing welded MS wire mesh weighin not less than 1 kg/Sqmt on the prepared surfaces fixing of wiremesh should be done using electric drill and nails it should be properly fixed on the surfaces complete all as specified and directed by the Engineer-in- Charge
M&L for casting and repairing of excessively damaged members with micro concrete at all levels with all leads and lift as directed including mixing, laying, levelling, finishing including curing complete. Grade of Micro-concrete to be M-40 at 28 days and same shall be procured from one of manufacturer given below. (Make : Fosroc/Sika/BASF/Krisha conchem/Dr Fixit Pidilite).(Rates includes jacketing,formwork and micro concrete)
Material and labour for demolition of reinforced cement concrete of Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed by the Engineer-in-Charge
Material and labour for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by the Engineer-in-Charge
Material and labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by the Engineer-in-Charge
Material and labour for MS TMT bars 8mm dia and over as in reinforcement cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends & binding with and including MS annealed wire not less than 0.9mm dia complete all as specified and directed by the Engineer-in-Charge
Material and labour for reinforced cement concrete (design mix) M-30 in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by the Engineer-in-Charge
Material and labour for applying 20mm - 25 mm screed with one component fibre reinforced PMM with water producing thixotropic consistency using heavy-duty slow speed drill with spiral mixing paddle or a Pan type mixer attached to spray units with nozzle at site applied by trowel or spray where ambient temperature if 30°C or more use of chilled water for conditioning the bagged product in an air-conditioned store prior to use. Mixing mperature shall be between 5 and 40°C. Mixed material shall achieve compressive strength of 15 MPa in 1 day & 45 MPa in 28 days and a flexural strength of 7 MPa @ 7 days. It shall compensate both plastic and hardened shrinkage and have minimum direct adhesive bond strength of greater than 2 MPa. It shall be alkaline, compatible with host concrete with similar thermal properties and shall achieve a elastic modulus of minimum 25 kN/Sqmm complete all as specified and directed by the Engineer-in-Charge. Make : Carlisle Syntec/Thermax Ltd/Kryton Build Mat Pvt Ltd/SNI Infratech Pvt. Ltd.
Dismantling of wrought Iron or mild steel work of any description
SATYANARAYAN CONSTRUCTION
S S ENTERPRISES
ASHOK CONSTRUCTION
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .