| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹24.7 L+₹1.8 L (7.65%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹26.0 L+₹3.0 L (13.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹27.4 L+₹4.4 L (19.3%)Rejected-Finance HOUSE NO 49 SECTOR 28 FARIDABAD 121008 HR | FARIDABAD | FARIDABAD | HARYANA | 121008 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹29.5 L+₹6.5 L (28.2%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹23.3 L
EMD Value
₹46,600
Closing Date
12 Mar 2020, 6:00 pmClosed
Col N S Johal
HQ 138 Works Engineers PIN-914138 C/O 56 APO
SPECIAL REPAIR TO BUILDING NO P-50 UNDER GE 865 EWS
2020_MES_326855_1
138WE/L-76/2019-20
Open Tender
Civil Works
Item Wise
180 days
GE 865 EWS
As per NIT
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹46,600
Yes
31 Mar 2020
19 Feb 2020
14 Mar 2020
19 Feb 2020
12 Mar 2020
7 Mar 2020
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of precast block work or stonework built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Dismantling timber scantlings fillets, rails, posts, rafters, purlins, etc, under 40 Sqcm in section, complete all as specified and as directed by Engineer-In-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc), or insulation boards/slabs/ blankets, any thickness any type including cover fillets, complete all as specified and directed.
Taking down shutters of any description area not exceeding 1 sqm each, resecuing or easing & adjusting and refixing in the same opening complete all as specified and directed.
Taking down shutters of any description area exceeding 1 sqm and not exceeding 2 sqm each, resecuing or easing & adjusting and refixing in the same opening complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and directed
Plain fillets of 2nd class soft wood, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 13 sq.cm & not exc 25 sq.cm, complete all as specified & directed.
2nd class soft wood as in beeding for edges of ceiling, lining or wooden flooring work, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 06 sqcm & not exc 13 sq.cm, complete all as specified & directed.
Cover fillets of standard hard board, 6mm thick, 40mm wide, and fixing with screws, complete all as specified and as directed by Engineer-In-Charge.
9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, medium density, fixed with screws to frame work as in fixed in wall panalling and partition, with nails to timber frame work, complete all as specified.
9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, medium density, fixed with screws to frame work as in fixed in ceiling, flat or sloping with nails to timber frame work, complete all as specified.
9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, medium density, fixed with screws to frame work as in palmet boxes etc, rebated or flat edged, complete all as specified.
19/20mm dia aluminium alloy anodised curtain rods, complete all as specified & directed.
Aluminium anodised curtain bracket of suitable size, complete all as specified & directed.
Precast cement concrete block, M-10(1:3:6), type C-1, (using 20mm graded crushed stone aggregate) masonry with solid blocks exceeding 10 Cm in width and setting in cement mortar 1:6, complete all as specified and as directed.
Rendering 15 mm thick, on other than fair faces of brick work or concrete surfaces, in cement mortar 1:4 rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed.
Rendering 15 mm thick, on fair faces of block or concrete surfaces, in cement mortar 1:6 rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed.
10 mm thick rendering in cement mortar 1:3 on concrete surfaces as in ceiling , surface finished even & smooth without using extra cement complete all as specified and directed .
Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar (1:4) complete all as specified and directed .
Preparation of new plastered surfaces of walls and applying two coats of exterior emulsion paint over a coat of primer complete all as specified and directed.
Preparation of old plastered surfaces of walls and applying one coat of exterior emulsion paint complete all as specified and directed.
Preparation of old plastered or unplastered surfaces of ceiling and applying two coats of white wash complete all as specified and as directed.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemperincluding a coat of primer over 3mm thick wall care putty complete all as specified and as directed.
Preparation of old painted wooden surface of any description and applying one coat of synthetic enamel paint complete all as specified and directed.
50 mm thick plain cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregates) as in plinth protection/path, finished even and fair including cutting grooves at every 3.00 metre and filled with bitumastic complete all as specified and directed.
Forming contraction (Dummy) joints 50 mm deep x 10 mm wide, filled with sealing compound grade 'A' complete all as specified and directed.
75mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in sub base of floor complete all as specified and directed.
Non skid ceramic coloured tiles 8mm thick (square/rectangular) , area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as directed by EIC, as in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. Shade/Colour of tile shall be approved by the GE.
Glazed ceramic coloured tiles of size 300 mm x 200 mm x 7 mm thick as on vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:4 complete all as specified and directed. Shade/Colour of tile shall be approved by the GE.
Dismantling roof tiles or roof treatment of any description including cement mortar, bedding (but not backing) and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
Brushing neat cement slurry with 3.0 kg of cement per square metre complete all as specified and directed.
Cutting out cracks to V-section in existing roofs or terracing, leaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified.
25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregates) as in floor finish, surface finished even and fair to receive top finish complete all as specified and directed.
APP (Atactic Poly-propylene polymer) modified membranes, five layered, 3mm thick weighing not less than 3.6 Kg/Sqm, having a centre core of polyester non-woven mat (FP) reinforcement dipped into APP modified mix and sealing all the over laps 75mm on length side and 100mm on width side of membranes by torching as per manufacturer’s instructions by authorised applicator only over and including a coat of industrial bitumen primer 85/25 @ 1.2 Kg per Sqm over plastered surfaces @0.50 Kg/Sqm and including 20mm thick screed bed in cement mortar 1:4 with WPC as manufacturer instruction, on roof slab, complete all as specified and as directed (WPC shall be measured and paid separately under respective item) .
Supply only liquid water proofing admixture.
Taking down carefully aluminium / copper point wiring light/fan/socket or power complete including unscrewing from board fitting and fixture such as switches, sockets, ceiling roses, lamp holders, brackets, pendent holder , light fittings , regulators, distribution/ Meter boards, MCBs etc and making good the distturbed surface matching with existing specifications complete all as specified and directed.
Point wiring for one light point or fan point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, FRLS single core, multi-stranded, copper conductor cable, 1100 Volts fire resistance ISI, drawn in and including PVC casing and capping, fire resistance, ISI marked, fixed surfaces of walls and ceilings, terminated in and including rectangular PVC board for mounting fitting/ switches/ sockets and 1.50 Sqmm, copper conductor, multi-stranded, FRLS as earth continuity wire connected to earth terminal, including making good to disturbed surface as matching to existing descriptions/ specifications, complete all as specified and as directed.
Description all as per serial item No- 43.00 here-in-before but for one 5 Amps socket outlet on same board, complete all as specified and as directed.
Description all as per serial item No- 43.00 here-in-before but for one 5 Amps socket outlet on independent board, complete all as specified and as directed.
Point wiring for 3-pin, 15 Amps, socket outlet on independent board with 4 Sqmm, PVC insulated, unsheathed, FRLS single core, multi-stranded, copper conductor cable, 1100 Volts, drawn in and including PVC casing and capping, fire resistance, ISI marked, fixed surfaces of walls and ceilings, terminated in and including rectangular PVC board for mounting fitting/ switches/ sockets and 2.50 Sqmm, copper conductor, multi-stranded, FRLS as earth continuity wire connected to earth terminal, including making good to disturbed surface as matching to existing descriptions/ specifications, complete all as specified and as directed.
Switch piano, flush type, single pole, one way, 5 Amps, 240 volts complete all as specified and as directed.
Switch socket combination 2-in-1, 5 Amps, flush type, complete all as specified and as directed.
Switch socket combination 2-in-1, 5/6-pin, 5/ 15 Amps, flush type, complete all as specified and as directed.
Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings,with & including 9 watt LED lamp complete all as specified and as directed.
Ceiling rose, surface bakelite 65 x 50 mm three terminals complete all as specified and directed.
Sheet metal enclosures for distribution box for MCBs, Single pole and neutral, 8 way with, 240 Volts, double door, with 200 Amps rated bus bar blank plate complete all as specified and directed.
Sheet metal enclosures for distribution box for MCBs, Single pole and neutral, 12 way with, 240 Volts, double door, with 200 Amps rated bus bar blank plate complete all as specified and directed.
Excavation in trenches n. exc 1.5m wide and n. exc 1.5 m deep and getting out in hard and dense soil complete all as specified and directed .
Returning filling in incl spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed .
Removing excavated soil to a distance n exc 50m and depositing at a level n exc 1.5m above the starting point complete all as specified and directed .
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type-I, flat, size 250mmx150mmx40mm, complete all as specified and directed.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed Note: Punned thickness shall be measured.
Replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm, 4 core, laid in trenches or passing through pipes, including making necessary connections at both ends, and taking down existing cable complete all as specified and directed.
Taking down existing unserviceable/old DBs from any height and any make good complete including disconnection from existing MCBs/Isolator etc complete all as directed.
Factory made epoxy powder coated distribution board ,double door, triple pole and 4 ways (TPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with one MCB TPN 415 V, 63 Amps, 10KA as incoming and 12 Nos, single pole, MCB 63 Amps, outgoing and conforming to IS : 8623 complete all as specified and directed.Make : Legrand/L&T/Siemens
Isolator, triple pole and neutral (TPN ) 63 Apms, 415 Volts, connecting with copper lugs including taking down old one complete all as directed. Make : Legrand/L&T/Siemens
Distribution board, single pole and neutral (SPN) MCB 40 Amps, 240 volts, 50 Hz AC, made from moulded self-existing thrmostate plastic and suitable 'C' curve 10 KA breaking capacity and terminal box suitable for 4 to 10 Sqmm cable complete, conforming to IS 8828 including taking donw old one all as specified and directed.Make : Legrand/L&T/Siemens
Distribution board, single pole and neutral (SPN) MCB 32 Amps, 240 volts, 50 Hz AC made from moulded self-existing thrmostate plastic and suitable 'C' curve 10 KA breaking capacity and terminal box suitable for 1.5 to 6 Sqmm cable complete conforming to IS 8828 incluiding taking down old one all as specified. Make : Legrand/L&T/Siemens
Rewinding of burnt winding of exhaust fans of sweep size 350-450mm including dismantling from site and removing the burnt out winding, cleaning the stator with CTC solution to remove the burnt slots complete. and rewinding the same with new super enamelled copper wire same gauge and size/number of turns, varnishing the winding and reassemble complete all as specified and directed.
Supply and fixing following spares part/items of exhaust fan of various type
Flexible twin twisted copper wire core of size 23/0.0076mm upto 1.5 mtr length.
Ball bearing suitable for sweep size 350mm- 450mm.
Gun metal bushings suitable for sweep 350mm-450mm.
Painting of exhaust fans upto 450mm sweep complete with two coats of synthetic enamell paint of white colour or any approved colour after cleaning the surfaces & marking the Sl Nos & formation name all as directed.
Replacement of louvers made out of metal sheets suitable for upto 450mm sweep exhaust fans
48 Watt LED streetlight fitting complete made up of pressure die cast housing with toughned glass and individual high powerLEDs with secondary optics, IP66 protection and impact resistance of IK07 & 10KV external SPD, including GI bracket made out of GI pipe 50 mm bore, medium grade pipe 1.2 m long bend to shape required fixed to pole / wall with 02 Nos MS clamps made out of flat iron 40 x 5 mm including nuts, bolts and washer, painting with two coats aluminium paint over a coat of primer, suitable for LED fitting, complete all as specified and directed. Make : Havells Cat part No LHETAXU7PA6W048 or equivalent in / Wipro / Bajaj /Crompton Greaves
Recess mounting LED light fitting 34 Watt including separate electronic driver & high brightness SMD LEDs ultra modern suitable for armstrong/grid/POP ceiling in MS housing with high brightness 4000K LED sutable for 230 Volts 50 HZ diffused type optics 600mm x 600mm in size complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed . Make: Havells cat part No:-PLR28/36WLED857MOD or equivalent in Bajaj/ Crompton Greaves/ Philips/ Wipro/GE.
1 x 20W LED, tube light fitting mounted on integrated sleek extruded polycarbonate LED channel with white acrylic cover suitable for 230 volt 50 Hz ,cool white colour, bipin holder, connector block etc complete will all accessorized internally prewired alongwith tube rod 20W LED and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed . Make: Havells cat part No:-STOUTPLUS600BS20WLED840SPCWH or equivalent in Bajaj/ Crompton Greaves/ Philips/ Wipro/GE.
10 Watts LED, 230 volts,50 HZ AC, bulk head fitting complete with all accessorized internally prewired alongwith 10W LED and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete including taking down existing unservicable light fitting complete all as specified and directed. Make: Crompton Greaves cat part No:- LBHE-10-CDL or equivalent in Bajaj/ Havells/ Philips/ Wipro/GE.
Sub main wiring for circuit/ submain wiring alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including PVC casing and capping, fire resistance, ISI marked, fixed on surfaces of walls/ ceilings, including making good to disturbed surface matching to existing descriptions/ specifications, complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanized iron wire 4.0mm dia as earth lead means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15 mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1(using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt, 15mm dia, medium grade, GI pipe as protection to earth lead and earth lead as 4.0mm dia GI wire (main earthing lead from earth electrode to test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing.
ESS AAR ENTERPRISES
M/S LIBE & CO
M/S Behl Sons
H R CONSTRUCTION
M/S BHAT ENGINEERS
PRAVEEN KUMAR AND SONS
M/S MA CONSTRUCTION Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .