Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹1.9 L+₹16,271.37 (9.46%)Rejected-Finance 35 1 B M 1ST BYE LANE CHAPDANI HOOGHLY 712222 | CHAPDANI | HOOGHLY | WEST BENGAL | 712222 | L2 | Rejected-Finance L2 | |
| 3 | L3₹1.9 L+₹16,436.10 (9.55%)Rejected-Finance 17 23 K P ROY LANE KOLKATA 700 031 | KOLKATA | KOLKATA | WEST BENGAL | 700031 | L3 | Rejected-Finance L3 |
Tender Value
₹1.8 L
EMD Value
₹4,000
Closing Date
12 Nov 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EX. ENGR (E)/ LTG/Z-I
OFFICE OF THE LIGHTING EX. ENGR (E) DEPARTMENT/ZONE-I THEKOLKATAMUNICIPALCORPORATION 79, BIDHAN SARANI , KOLKATA WEST BENGAL 700006
REPAIRING WITH REPLACEMENT OF DAMAGED PILLAR BOX,POLE AND OTHERS ELECTRICAL ACCESSORIES AT WARD NO 29, 30, 33 UNDER BR III.
2026_KMC_1047186_1
LTG/131/BR-III/Z-I/26-27
Open Tender
Electrical Work/ Equipment
Percentage
20 days
kmc ward 333
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹4,000
17 Nov 2026
30 Oct 2026
13 Nov 2026
30 Oct 2026
12 Nov 2026
30 Oct 2026
120 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Installation the feeder pillar box only on cement brick foundation
including plastering and neat cementing as per specification and
direction of E.I.C. | 10 | EACH | 2,396 | ₹23,960 |
| 2 | Supplying & Erection of medium size feeder pillar box of Size (1200 x
750 x 450 mm) made up of 2 mm thick MS Plate along with suitable
M.S. Angle. The P.B. have double hinge door at the front & back with
suitable locking arrangement. The box will be painted by 2 cores of
aluminiam paint over 1 coat of red oxide paint. Suitable arrangement
should be provided for fixing of Timer unit, fuse unit & other
accessories. Leg of the pillar box will be 900 mm in length by made
up of (35 x 35 x 3 mm MS Angle with suitable base Plate. Legs of the
Pillar box will be erected at 300 mm below the ground level with
cement concrete (6:3:1). Rest portion coverd by 5" Brick Wall with
plastering & net cement & bottom portion filled with silver sand as
drawing & direction of E.I.C | 10 | EACH | 9,241 | ₹92,410 |
| 3 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION -
REPAIR 14. Dismantling steel tubular/Rail/Strut embedded in CC
foundation incl. excavation, filling of holes, restoring surface,loading
at site and delivering, unloading, sorting, stacking properly at any
place as per direction upto a lead of 1.6 km | 7 | PER POLE | 649 | ₹4,543 |
| 4 | SCHEDULE OF RATES FOR OH LINE INSTALLATION (LT
DISTRIBUTION).Erection of Poles.Erection of Single Steel tubular
pole of length as given below with/without sole plate & Cap etc. in CC
foundation (Proportion and dimension indicated below), having
600x600x150 mm thick CC (4:2:1) base block below sole plate/pole
with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and
0.30 mts. above ground level including 3 mm thick neat cemented
finish and GI earth bolt after making drilled holes etc. on pole &
carriage of pole upto 1.6 Km from Store to work(site including filling
up the excavated earth pit with shifted soil and ramming properlyUpto
9.0 mtr. Size 0.6x0.6x1.70 mts | 7 | SET | 2,835 | ₹19,845 |
| 5 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials
from K-1 to K-14 are excluding VAT) 134. 50mm x 6mm Galv. [Hot
Dip] steel strip | 7 | METER | 144 | ₹1,008 |
| 6 | SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Soil
Excavation.Excavation of soil FOR installation of Earth Electrode
and filling & ramming.FOR Morrum Soil. | 7 | CUBIC METER | 286 | ₹2,002 |
| 7 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials
from K-1 to K-14 are excluding VAT) 124. 40mm GI pipe
(ISI-Medium) | 7 | METER | 221.4 | ₹1,549.8 |
| 8 | BUILDING WORKS (F) STRUCTURAL STEEL WORKS, GRILLS,
GATES ETC. B. REPAIRING 2. Welding in M.S. structural work with
gas or electric: (a) Tack weld | 50 | POINT | 9 | ₹450 |
| 9 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION -
REPAIR 16. Supplying and Fixing GI water proof looping cable box
having hinged GI Top Cover having 4 mm thick with rubber gasket
lining, railway type mechanical locking arrangement, earthing terminal
with lug etc. of the following sizes as indicated below, Comprising of
one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc.
and housing the same in pole muffing incl. addition and alteration to
the existing CC muffing (6:3:1) after dismantling the damaged looping
cable box etc. where necy. incl. painting (a) 200 x 150 x 100mm | 7 | EACH | 498 | ₹3,486 |
| 10 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC
insulated & unsheathed single core stranded copper wire
(Brand(approved by EIC) of the following sizes in the prelaid
polythene pipe and by the prelaid GI fish wire and making necy.
connection as required 3 x 22/0.3 (1.5 sqmm | 90 | RUNNING METER | 48 | ₹4,320 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.08 MB
Tendernotice_2.pdf
PDF • 0.60 MB
BOQ_2565360.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .