| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC | L1 | Accepted-AOC Being a lowest | |
| 2 | L2₹33.2 L+₹2.0 L (6.30%)Rejected-Finance BALSUA P O JHAKOLARI PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being not a lowest | |
| 3 | L3₹35.0 L+₹3.7 L (11.9%)Rejected-Finance 58 1ST FLOOR PATEL NAGAR BATHINDA | BATHINDA | BATHINDA | PUNJAB | L3 | Rejected-Finance Being not a lowest | |
| 4 | L4₹36.2 L+₹4.9 L (15.7%)Rejected-Finance HOUSE NO 104 WARD NO4 MOHALLA WADHERIAN PATHANKOT GURDASPUR PUNJAB 145001 UDYAM PB 16 0006453 | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Being not a lowest | |
| 5 | L5₹37.1 L+₹5.8 L (18.6%)Rejected-Finance | L5 | Rejected-Finance Being not a lowest |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
18 Jan 2020, 6:00 pmClosed
GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
SPECIAL REPAIR TO BLDG NO. T-102, T-104, T-125 AND T-129 AT 19 ENGR REGT AND CERTAIN PROVN OF WORKS UNDER AGE BR-II AND AGE EM OF GE (WEST) PATHANKOT
2019_MES_307432_1
GE/PKT-60/2019-20
Open Tender
Civil Works
Item Rate
180 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹88,000
Yes
13 Feb 2020
18 Dec 2019
20 Jan 2020
18 Dec 2019
18 Jan 2020
2 Jan 2020
19 Dec 2019 - 28 Dec 2019
Amount
Dismantling of AC corrugated or semi corrugated sheeting in roof including ridges etc.
S & F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, etc. fixed with self tapping screws as specified.
S & F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet pieces 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall and as in ridge etc fixed with self tapping screws as specified.
S & F hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc,) including all necessary drilling bolting or riveting, etc and similar work conforming to Fe 410-0 or Fe 310-0
S & F mild steel work in tubular trusses (framed) /rectangular hollow section, purlines and fastening including distance pieces etc. including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 all as specified and directed.
Dismantling of wall and ceiling boards (fibre, plup, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets.
S & F for suspended false ceiling system using chicago metallic (E grid)exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length)with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant termite resistant , fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture complete all as directed.
Fixing only anodised aluminium snap grid frame work of size 605 X 605 mm for false ceiling all as specified.
Fixing only non asbestos fibre cement building boards 4mm thick fixed or laid/inserted to timber/GI/Aluminium framework with screws
Taking down cement plaster of any description and thickness on walls/ceillings etc including racking out joints,hacking for key, scrubbing down with water etc complete all as specified and as directed
Material and labour for rendering 15 mm thick on brickwork or concrete wall surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for preparing of new plasterd wall surfaces and applying two coats of oil bound distemper over two coats of wall care putty etc complete all as specified and as directed.
Material and labour for complete removal of existing treatment wall surfaces and applying two coats of oil bound distemper over two coats of wall care putty etc complete all as specified and as directed.
Material and labour for preparation of new plasterd wall surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
Material and labour for complete removal of existing treatment of wall surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M & L for plain cement concrete type D-2, 1:4:8 (40mm graded crushed stone aggregate), 75mm thick as in sub base.
M & L for 75 mm thick PCC 1:3:6 type C2 using (40mm graded stone aggregate) as in plinth protection, path & hardstanding.
Dismantling of floor hearth and wall tiling incl cement morter bedding (but not backing) removing serviceable tiles to store and rubbish off the premises.
M&L for 25mm thick plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate as in levelling course.
M & L for coloured joint free Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) are of each tile exc 0.18 Sqm but n. exc. 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick screed bed or bedding layer with CM 1:6 complete all as specified.
M & L for coloured joint free Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) are of each tile exc 0.18 Sqm but n. exc. 0.38 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as in skirting/dado including 10mm thick backing coat in CM 1:4 complete all as specified.
M & L for non-skid ceramic coloured tiles as in floors, area of each tile exceeding 0.11 square metre but not exceeding 0.18 square metre of 7 to 8 mm thick set and jointed in neat cement slurry and pointing in coloured cement laid over 20 mm thick screed bed in cement mortar 1:6 complete all as specified.
M & L for coloured Glazed ceramic tiles in vertical surfaces 350 x 250 x 7mm/450 x 350 x 7mm set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat in cement mortar 1:4 complete all as specified.
Demolition stone slabs and tiles laid, bedded and pointed in any mortor description or thickness in floors, aprons etc complete
M & L for chequred cement concrete tiles 30 cm x 30 cm x 25mm thick , set, jointed and pointed in neat cement slurry in floors with grey cement and pigments including 20mm thick secreed bed or bedding in CM 1:6 complete all as secified and as directed.
M & L PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, culls, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up[top 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughjs and the like including weathering, slightly rounded or chamfered angles and throating, as directed in kerb/coping including necessary form work complete.
Demolition of stone/brick masonry in CM or cement/ lime mortar complete all as specified.
M & L for brick work with burnt bricks sub class ‘B’ old size brick, straight or curved on plan exc 6.0 m mean radius built in cement mortar 1:6.
Taking down chowkats or frames with shutters (without taking off shutters from frames) not exc 1.5 Sqm each.
Taking down chowkats or frames with shutters (without taking off shutters from frames) exc 1.5 Sqm but not exc 4 Sqm each.
S & F pressed steel frame of size 165 x 60mm for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate, etc complete all as specified
S & F 35 mm thick factory made second class hardwood glazed /gauzed and skelton door shutters, open rebated & prepared to recive glass/ gauged etc as in mosquito proof door shutter etc with out sash bars, edges of framing plain, chamfered or rounded,fitted with cut & mitred beads for securing glass, gauze etc, size of members of shutters as specified in SSR Part I section 8, clasue 8.20(a) and fixed to chowkats complete all as specified.
S & F 40mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides.
S & F MS barrel tower bolt 200mm long stove enameled black with bright bolt.
S&F MS pressed handle oval type, stove enamelled black 150mm size
S & F MS Sliding door bolts 300mm long plate type stove enameled black with bright bolt not less than 12mm dia with and incl a min 6 bolts and nuts four on bolt plate and two on staple plate.
S & F door spring ordinary rat tail rod pattern springs including roller and roller plate complete of mild steel 300mm long complete including welding to steel frames.
S & F steel window/Ventilator factory made out of box type and shutter (double shutter) with sash bar made out of section using flash butt welding, hinges shall be provided to both shutters complete including all fittings including grills, glazing , guaging and two coat synthetic enamel paint over a coat of red oxide primer all as per drg No CEPZ/TD/245/01 Sh 1/1, CEPZ-TD/246/01 Sheet 1/2 and Sheet 2/2 all as specified and directed by Engr-in-Charge.
M & L for applying two coat of synthetic enamelled paint over a coat of red oxide on steel and iron surfaces of any description, not other wise described over 10 cm width or girth including preparation of new surfaces.
M & L for applying one coat of synthetic enamelled paint over steel and iron surfaces of any description , not other wise described over 10 cm width or girth including preparation of old surfaces.
M & L for applying two coats of synthetic enamelled paint over a coat of red oxide on steel and iron surfaces of any description, n. exc10 cm width or girth including preparation of new surfaces.
M & L for applying two coats of synthetic enamelled paint over a coat of pink primer over wood & wood based materials of any description , not other wise described over 10 cm width or girth including preparation of new surfaces.
Taking up or down steel tubing 15mm dia and connections, including cleaning for refixing or removal to store.
Taking up or down steel tubing 20mm dia and connections including cleaning for refixing or removal to store.
S & F 15mm dia medium grade GI tubing with all fitting and fixed to wall, ceiling or laid in floors etc
S & F 20mm dia medium grade GI tubing with all fitting and fixed to wall, ceiling or laid in floors etc
S & F vitreous china wash down water closet pan (Pedestal Pattern ) white including fixing bolts, plastic water closet seat, black, closed pattern, solid type with flat bottom, and cover and mild steel chromium plated hinging device complete and including making good to floor to match with adjoining surfaces complete all as specified and as directed
S & F Wash basins, Vitreous China (flat back type) 550 x 400mm, including cutting for and pinning in ends of brackets or erecting stand , waste pipe etc.
S&F brass chromium plated tubular towel rail 20mm dia 'D' type 60cm long between flanges all as specified and directed by Engr-in-charge.
S & F PVC 10 ltrs capacity valveless symphonic action type low level flushing cistern including flush pipe, cantilever brackets incluiding taking down existing cistern etc complete.
S & F PVC connections 15mm size with PTMT nuts of length 450mm.
Supply and fixed Pillar taps fancy type cast copper alloy chromium plated with capstan head without letter Hot or Cold water screwed down for 15 mm dia iron pipe.
S & F 15mm bore dia of pipe bib taps cast copper alloy, fancy type chromium plated, with capstan head screwed down, screwed for iron pipe of brass ferrule complete.
Supply and fix stop valve/angle cock fancy type cast copper alloy, chromium plated with capstan head serewed down for 15 mm dia iron pipe.
Supply and fixed stop valve / angle cock fancy type cast copper alloy chromium plated with long shank and cup (concealed type) capstan head serewed down for 15 mm dia iron pipe.
Taking down eves gutter and rain water pipes (any size or pattern), including all fittings, head shoes, bends, swan-necks atc., incl cleaning or refixing or removal to store (mesured overall as fixed along the centre line over fittings the accessories)
S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as directed.
S & F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls or laid in floor or trench.
S & F 110 mm bore PVC (SWR) bends complete all as specified.
S & F 75 mm bore PVC (SWR) bends complete all as specified.
S & F PVC (SWR) 110mm bore 'T' equal or unequal with access door complete all as specified and directed.
S & F 75mm PVC(SWR) floor trap plain with grating incl jointing with solvent cement.
S & F PVC (SWR) 110mm bore vent cowl complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position ( unframed ) as in purlins.
S & F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-W (Gde E-250) quality -A.
Material and labour for preparing of new plasterd wall surfaces and applying of two coats of oil bound distemper over a coat of primer etc complete all as specified and as directed.
Material and labour for complete removal of existing treatment wall surfaces and applying of two coats of oil bound distemper over a coat of primer etc complete all as specified and as directed.
M & L roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing neat cement slurry with 3.0kg of cement per sq. metre.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for.
M & L machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over screed bed or bedding layer 20 mm thick in cement mortar 1:6 complete all as specified.
M & L machine kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over backing coat 10mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for and refixing in the same position after carrying out necessary repairs.
Dismantling of framed trusses n.exc 10.0m and refixing in the same position after carrying out necessary repairs.
S & F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410-W (Gde-E-250) quality-A.
S & F mild steel, plain, black sheet 1.25mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for laying of under ground cable, foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in any type of soil (sooft/hard).
M & L for cement concrete Type C2 1:3:6 (40 mm graded aggregate) as in foundations, filling and mass-concrete.
M & L for modular brickwork with fly ash burnt bricks, straight or curved on plan exc 6m mean radius, built in 1:4 complete all as specified.
M & L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement.
Removing excavated material(soil) exc. 250m but n exc. 500m and dipositing where directed at a level not exc 1.50m above the strating point.
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M & L for mild steel TMT bars 6 m to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M & L for precast reinforced cement concrete type B1 1:2:4 (20 mm graded stone aggregate) as in cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, set in cement mortar 1:4 complete all as specified.
S & F reinforced cement concrete pipes, class NP 2 of 300mm bore with one collar per length of pipe complete all as specified.
M&L for providing concrete to drain pipes including packing under and haunching completely surrounding pipes with cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) after they are laid and tested complete all as specified.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/hard soil all as directed.
M & L for excavation in post holes (or similar holes) each n. exc 0.5 cum, getting out in soft/hard soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as directed.
PCC (1:5:10) type E-2 using 40mm graded stone aggregate as in foundation filling & mass concreting complete all as specified and directed.
PCC 1:2:4 type B-2 ( 40mm graded stone aggregate ) in foundation filling and mass concrete complete all as specified and directed.
Rendering 15mm thick on surfaces other than fair faces of brick work or concrete surface in CM 1:6 (Internal surfaces) complete all as specified and directed.
S & F mild steel screw bolts (machine made) 11 to 15 mm dia of neck with hexagonal or square heads one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut ex. 5 cm and n exc 10cm long.
S & F mild steel bolts (machine made) of dia exc. 12mm and n.exc 20mm, purpose made, with hexagonal or square heads one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut ex. 30 cm long.
M & L for machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade rubber moulded glossy finish with grey cement and pigment.
M & L for Sand filling under floors or in foundations including watering and consolidation.
Returning, filling in, excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M & L for brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in
M & L for form work to soffits of suspended slabsuch as roof slab, floor slab landing and similar work not exc 200mm thick.
M& L for 100 mm thick cement concrete type D2, 1:2:4 (40mm graded stone agregate) as in flooring complete all as specified and directed.
M & L for 25mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S & F stainless steel kitchen Plate rack 1mm thick of size not less than 900mm x 600mm x 200mm complete all as specified and directed
M & L for block board 12 mm thick, grade 2 quality, interior grade, commercial type complete all as specified and directed.
M & L for block board 18/19 mm thick, grade 2 quality, interior grade, commercial type complete all as specified and directed.
M & L decorative laminates 0.9mm thick type I, or surface finish, colour and pattern as approved.
S & F 30mm wide continuous (piano) hinges, mild steel, bright finish or electroglavanised.
S & F 150 mm extruded brass handles, fabricated type, polished bright
S & F 100mm hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws.
S & F ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed
M & L for 2nd class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads, sectional area not exc 3 sq cm.
S & F mild steel heavy duty telescopic channel 500 mm long for drawer complete all as specified and directed..
Taking down old unserviceable copper/aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators, sockets and defective main switch/DB/MCB/Metal plug etc. by unscrewing carefully from boards etc and making good disturbed surfaces of walls complete all as specfied and directed.
M & L for point wiring for light/fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC concealed conduit having thickness not less than 1.8 mm with all fittings including anodise press steel sunk box having thickness not less than 2 mm with 3mm thick ISI marked bakalite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly in , cutting chiseling for concealed piping ,including insulation test of point wiring and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified. Note: colour coding is to be maintained. (Ph-Red, N-Black, Half -Yellow, Earth- Green)
All as per srl item No 113.00 above but for 5 pin 5 amps socket outlet independent board complete all as specified and directed.
All as per srl item No 113.00 above but for 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed.
M & L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with in and including PVC concealed conduit having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash /colour wash to matching with the existing colour and all as specified and directed. Note: (a) Insulation test of point wiring (b) colour coding is to be maintained. (Ph-Red, N-Black,Earth- Green)
S & F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed.
S & F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
S & F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed.
S & F ceiling rose 65 x 50mm three terminals complete all as specified and directed.
S & F ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed.
S & F LED smart Lamp B22 type, 14 watt, complete all as specified and directed.
S & F tube light fitting energy saving decorative LED box type 20 watt (4 Feet), 230 volts, 6500 K energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories prewired and including making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings. (Note power factor should not be less than 0.95 and fitting shall be fixed on 02 Nos PVC square blocks) complete all as spd and directed. Note:- (i) Contractor shaal produce LM79 & LM 80 test report from OEM owned NABL accredited laboratory. (ii) Contractor shall give guarantee/ warranty of complete fitting/ fixture for minimum 2 years from the date of completion. (iii) Contractor shall conduct the inspection of company representative at site before installation of the material at no extra cost. (iv) Contractor shall arrange complete material at site for approval of GE before incorporation in the work.
S & F sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
S & F MCB single pole 240 volts, of rating from 6 to 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
S & F MCB SPN 240 volts, of rating from 6 to 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
M & L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore medium grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt and precast PCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed. Note: Excavation and earth work is deemed to be included in the rates quoted.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying and stretching the cable and punned down to form a bed. The punning shall be done by hand, complete all as specified and directed.
Supply and laying well burnt old size bricks sub class 'B' in trenches laid dry flat for cable protection of U/G cable all as specified and directed by Engr-in-Charge.
Supply and fixing GI tubing medium grade of 40 mm nominal bore of pipe in trenches/under roads/ under culverts/under paths/under floor/on walls /with pole in new position with screwed sockets joints, together with all tube fittings (such as bends, elbow, tees, short places connections back nuts, diminishing places, caps, plugs and union etc) complete all as specified and directed .
Supply and laying for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 Volts grade, of size 16 Sqmm 2 core complete all as specified and directed. Note:- Earth work including excavation, returning filling , removing, sand cushioning, GI pipe,brick covering for mechanical protection of cable etc will be measured and paid for separately under respective items of schedule.
S & F bldg secuirty light fitting energy saving high efficiency LED street light fitting 25 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of suitbale size and making connections using cord flexible 3 core copper cable of size 23/ .0076 from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage.
M & L for fixing of Exhaust Fan, heavy duty, 230 volts, 300 mm sweep, complete with louvers shutter complete all as specified and directed.
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 45,658.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 5% (Five percent) of the accepted contract sum shall be delivered by the successful bidder within 28 days from the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
GANDOTRA CONSTRUCTION CO
M/S RUDRA CONSTRUCTION CO
Ambika Construction Co
OMKAR SHARMA AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .