Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-AOC AT SAMET ELECTRO TOWER TAMRIT MARKET COMPLEX ROOM NO 15 HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | ₹1.2 L | L1 | Accepted-AOC technocommercially eligible L1 bidder |
| 2 | Rejected-Technical AT FCI LAXMI BAZAR TALCHER PO VIKRAMPUR DIST ANGUL ODISHA 759117 | TALCHER | ANGUL | ODISHA | 759117 | - | - | Rejected-Technical REJECTED FOR NOT BEING L1 |
| 3 | Rejected-Technical | - | - | Rejected-Technical REJECTED FOR NOT BEING L1 |
| 4 | Rejected-Technical NABA MISHRA COLONY HATATOTA TALCHER DIST ANGUL PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | - | - | Rejected-Technical REJECTED FOR NOT BEING L1 |
Tender Value
₹1.8 L
EMD Value
₹2,300
Closing Date
20 May 2024, 5:00 pmClosed
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Electrical Wiring of Non-residential buildings at Rest rooms, Store room, Latrine room of filter bed, INTUC Office rooms, Security guard rooms, Coal dispatch room, and Drinking water supply room at Project Office of JNC, JA.
2024_MCL_307632_1
GM(JA)/EnM/e-Tender/ 24-25/E-648/13 Dtd 07/05/2024
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
Jagannath OCP
As per NIT
4 documents required · 4 mandatory
₹2,300
Yes
17 Jul 2024
7 May 2024
22 May 2024
8 May 2024
20 May 2024
8 May 2024
8 May 2024 - 13 May 2024
Amount
Scope of the Work:- i. The manpower engaged should be VT trained. ii. Supervisor of shift will engage the manpower in job. iii. The manpower will bring their own safety gears, i.e. shoes, helmet, safety belts, etc. as applicable iv. The job includes electrical wiring of non residential buildings at rest room, store room, latrine room of filter bed, INTUC office rooms, Security guard room, coal dispatch room, drinking water supply room at Project Office.
Wiring for light point/fan point/exhaust fan point/ccall bell point with 1.5 sq.mm FR PVC insulated copper conducter single core cable in surface/recessed PVC conduit with piano type switch phenolic laminated sheet, suitable size MS Box and earthing the point with 1.5 Sq mm FR PVC insulated coopper coonducter single core cable etc. as required .
Wiring for Circuits/sub-main wiring along with Earth wire with the following sizes of FR PVC insulated copper conducter single core cable insurface/recessed PVC conduit as required .2x2.5 Sq.mm + 1x2.5 Sq.mm earth wire
Wiring for Circuits/sub-main wiring along with Earth wire with the following sizes of FR PVC insulated copper conducter single core cable insurface/recessed PVC conduit as required . 4 x6 Sq.mm +2x6 Sq.mm earth wire
Supplying & fixing metal Box of 180mm x 100mm x 60mm deep(nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 5pin 15/16 Amps socket out let and 15/16 Amps piano type switch,connection .
Supplying & fixing metal Box of 150mm x 75mm x 60mm deep(nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3pin 5/6 Amps socket out let and 5/6 Amps piano type switch,connection .
Supplying & fixing of 5 Amp to 32 Amps rating 240/415 Volts 'C' curve miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections , testing & commissioning etc as required
Providing & fixing of 20 Amps , 240 V,SPN Industrial type socket out let with 2 Pole and earth metal enclosed plug top along with 20 Amp "C" Curve, SP MCB in sheet enclousure with on surface with chained metal cover for socket outlet and complete with connection , testing and commissioning etc as required
Supplying & fixing of Metal box of following sizes(nominal size) on surface with suitable size of phenolic laminated sheet cover in front including painting as required. 180 mm x100 mm x60 mm deep
Supplying & fixing of Metal box of following sizes(nominal size) on surface with suitable size of phenolic laminated sheet cover in front including painting as required. 200 mm x150 mm x60 mm deep
Installation , Testing & Commissioning of pre-wired, florocent fittings complete with all accessories and tube etc. directly on wall including connection with 1.5 Sq.mm PVC insulated copper conducter , single core cable and earthing etc as required
Supplying and fixing of 3 Pin 5 Amp ceiling rose on the existing junction box wooden block including connection etc as required.
Supplying & fixing of Angle holder including connections etc as required .
Supplying and fixing stepped type electronic fan regulator at existing modular plate switch box including connections but excluding modular plate etc as required.
Providing and fixing of DP MCB with encloser (32 Amp)
Providing and fixing of 32 Amp main switch .
Providing & fixing of MCB Distribution box (4 way)
Supplying & Drawing of 6 Sqmm twin core weather proof Alluminium service wire
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/S MAA ELECTRICALS
J.N. RAY
M/S. S.S.ENTERPRISERS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].