Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 CrAdmitted-Finance | ₹5.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹5.4 Cr+₹16.0 L (3.06%)Admitted-Finance | ₹5.4 Cr+₹16.0 L (3.06%) | L2 | Admitted-Finance |
| 3 | L3₹5.4 Cr+₹18.0 L (3.45%)Admitted-Finance | ₹5.4 Cr+₹18.0 L (3.45%) | L3 | Admitted-Finance |
| 4 | L4₹5.4 Cr+₹19.6 L (3.76%)Admitted-Finance | ₹5.4 Cr+₹19.6 L (3.76%) | L4 | Admitted-Finance |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/S TSASKAN CONSTRUCTION COMPANY L4 | M/S SONAM RIGZIN L2 | M/S GHULAM MOHD SOFI L1 | M/S TASLIM AHMED L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Civil Items. Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and
disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil . including cost of carriage compltete job. | 987.92 | Cum | 150 ₹1,48,188 | 120 ₹1,18,550.4 Lowest | 179 ₹1,76,837.68 | 170 ₹1,67,946.4 |
| 2.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. | 1,013.11 | Cum | 100 ₹1,01,311 Lowest | 120 ₹1,21,573.2 | 169 ₹1,71,215.59 | 150 ₹1,51,966.5 |
| 3.00 | Extra rates for quantities of works executed :
2.22.1 In or under water and/ or liquid mud, including pumping out water as required. | 790.33 | Cum | 130 ₹1,02,742.9 | 80 ₹63,226.4 Lowest | 339 ₹2,67,921.87 | 120 ₹94,839.6 |
| 4.00 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)including carriage complete job.including cost of carriage compltete job. | 41.65 | Cum | 5,000 ₹2,08,250 | 4,500 ₹1,87,425 Lowest | 4,786 ₹1,99,336.9 | 5,000 ₹2,08,250 |
| 5.00 | Providing and fixing up to floor five level precast cement concrete solid blocks including hoisting and seating in position with cement mortar 1:3 (1: cement 3: coarse sand), cost of centering, Shuttering and complete. Crushed 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mmm nominal size) | 69.81 | Cum | 8,700 ₹6,07,347 Lowest | 10,000 ₹6,98,100 | 9,500 ₹6,63,195 | 9,500 ₹6,63,195 |
| 6.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone | 13.27 | Cum | 9,700 ₹1,28,719 Lowest | 10,000 ₹1,32,700 | 11,000 ₹1,45,970 | 10,600 ₹1,40,662 |
| 7.00 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. | 1,03,977 | kg | 98 ₹1,01,89,746 Lowest | 108 ₹1,12,29,516 | 103 ₹1,07,09,631 | 106 ₹1,10,21,562 |
| 8.00 | Centering and shuttering including strutting, propping etc. and removal of form for:
A, Foundations, footings, bases of columns etc. for mass concrete. | 345.6 | Sqm | 300 ₹1,03,680 Lowest | 320 ₹1,10,592 | 409 ₹1,41,350.4 | 300 ₹1,03,680 Lowest |
| 9.00 | B, Lintel, beams, plinth beams, girders, bressumers and cantilevers. | 342.64 | Sqm | 350 ₹1,19,924 Lowest | 350 ₹1,19,924 Lowest | 425 ₹1,45,622 | 550 ₹1,88,452 |
| 10.00 | c, Suspended floors, roofs, landings, balconies and access platforms. | 962.98 | Sqm | 350 ₹3,37,043 Lowest | 350 ₹3,37,043 Lowest | 673 ₹6,48,085.54 | 550 ₹5,29,639 |
Tender Value
₹5.3 Cr
EMD Value
₹10.7 L
Closing Date
4 Jan 2023, 2:00 pmClosed
Ex. Engineer PWD RnB Division Nobra
Ex. Engineer PWD RnB Division Nobra
Construction of Science Laboratories at Degree college Nubra
2022_PWD_8716_1
PWD RnB/N/ 122- 2022-23
Open Tender
Civil Works - Others
Item Rate
360 days
Nubra
please read NIT
7 documents required · 7 mandatory
₹5,000
Payable To Ex. Engineer PWD RnB Division Nobra
₹10.7 L
Executive Engineer Pwd RnB Nubra
27 Mar 2023
14 Dec 2022
6 Jan 2023
14 Dec 2022
4 Jan 2023
14 Dec 2022
3 Jan 2023
Amount
Civil Items. Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil . including cost of carriage compltete job.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Extra rates for quantities of works executed : 2.22.1 In or under water and/ or liquid mud, including pumping out water as required.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)including carriage complete job.including cost of carriage compltete job.
Providing and fixing up to floor five level precast cement concrete solid blocks including hoisting and seating in position with cement mortar 1:3 (1: cement 3: coarse sand), cost of centering, Shuttering and complete. Crushed 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mmm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for: A, Foundations, footings, bases of columns etc. for mass concrete.
B, Lintel, beams, plinth beams, girders, bressumers and cantilevers.
c, Suspended floors, roofs, landings, balconies and access platforms.
e, Edges of slabs and breaks in floors and walls Under 20 cm wide
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. a) works upto plinth level
b) All works above plinth level upto floor V level
COMPRESSED STABILISED EARTH BLOCKS (CSEB) in superstructure above plinth level upto floor five level and curing complete in:Cement mortar 1:6 (1cement : 6 coarse sand)Critical parameters related to finished CSEB:- Dry density 1750 kg/m3 Water absorption Less than 15% Dry Compressive strength More than 2.8N/mm2 Wet Compressive strength More than 1.2 N/mm2 Flexural strength (bending strength) More than 0.5 N/mm2 Pitting depth (Erosion resistance) Less than 10 mm Linear expansion of block upon saturation with water Less than 0.10% Critical parametersof soil for CSEB block production:-Sand and gravel More than 65%Silt 5% to 20% Clay 10% to 15% Plasticity Index Less than or equal to12 Phvalue Between 6 and 8 Stabilizer:- Cement Not less than 5%
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Stone tile work for wall lining upto 10m height with special adhesive likearaldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement: 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade.Granite stone of any colour and shade
Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete.
Providing and fixing bright finished brass door latch with necessary screws etc. complete 300x16x5 mm
Providing and fixing bright finished brass handles with screws etc. complete 125mm
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10mm
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete 100mm
Providing and fixing factory made PVC door frames of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and jointed with two numbers of 150mm long brackets of 15x15mm MS square tube, the vertical door profiles to be reinforced with 19x19mm MS square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using MS screws of 65/100mm size complete as per manufacturers’ specifications and directions of engineer-in-charge
Providing and fixing 30 mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawin
Providing and fixing factory made uPVC Fenista,Saint Goblin, Ncl Veka colour as approved by engineer casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm).9.149A.5 Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm).
Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/top hung UPVC windows, of approved quality, with necessary stainless steelscrews etc. as per direction of Engineer-in-charge 200x19x1.9mm
Providing and fixing casement handle made of zinc alloyed (white powder coated) for UPVC casement window with necessary screws etc. complete.
Providing and fixing of traditional Ladakhi Shingstag of height 2 feet in 2nd class kail wood as per drawing complete in all respects (including polishing, cement concrete coping , fasteners which to be paid separately) including cost of transportation, labour, wood, wastage, taxes, profits etc as per directions of Engineer- in-charge
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20 mm nominal size stone aggregate.
Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) Light shade using white cement
Providing and laying Ceramic glazed floor tiles of size 600x600 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.,complete.
VITRIFIED FLOOR TILES Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigments etc. complete Size of tile 800x800 mm
Providing and laying Vitrified tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades,in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. size of tiles 800x800mm
Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Polished Granite stone slab jet Black, Cherry Red, Elite
Insulation of wall Providing and fixing (PU) Polyurethane 50mm thick of density 28kg -38 kg/ CU .M in between cavity wall.
Providing, fixing and applying Plaster of Paris (POP) false ceiling consisting of frame work made with 50mm sq M.S. tubes of 18 G thickness as main runner at 600 mm c/c both ways, suspended/ supported with M.S. flats 25x4 mm from existing R.C.C. slab, finished smooth to line and level including necessary supports, scaffolding etc. as required and also including applying a coat of red oxide zinc chromate primer over the M.S. frame work and suspenders complete. Including providing and fixing expanded metal of size 5.25 mm x 1.25 mm thickness welded to main runners and applying POP (calcium sulphate semi hydrate variety) to the expanded metal of thickness not less than 10 mm
Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineerin- charge.
Providing and Fixing 15 mm thick densified tegular edged eco-friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanizing @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” ofsize 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main ’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting onperiphery walls /partitions on Perimetre wall angle pre-coated steel size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (Spin tone / Cosmos/hexa) in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanized steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’ , bottom exposed with 24 mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications,drawings and as directed by engineer-in-charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs)having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non - combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/m 0 KC.
15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 fine sand)
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) 1 : 3 ( 1 cement : 3 fine sand) Cement must be PPC with minimum 25% flyash content
Pebble dash plaster up to 10m height above ground floor with a mixture of washed pebble or crushed stone 6mm to 12.5mm nominal size dashed over and including fresh plaster in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mix with 10% finally grounded hydrated lime by volume of cement.
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm
Polishing on wood work with ready mixed wax polish of approved brand and manufacture:
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Dry stone pitching (any thickness) including cost of stones On Horizontal
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall not to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with with water proofing cement compound @ 0.253kg/ sqm. This layer will beallowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Providing and fixing double glazed units(DGU) comprising 6 mm thick glass on either side with 12 mm thick inert gas gapin The DGUs shall be processed from reputed glass processors.
Sanitery Works, Providing, laying and jointing uPVC Pipes (I.S:4985-2000) 6kgf/cm2 including jointing with solvent cement, testing, excavation, refilling and disposal of surplus earth wherever required complete in all respect. a) 110 mm dia
b) 160 mm dia
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design a)100mm diameter
b)150 mm diameter
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design a) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) ith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes :Size 90 x 80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m all kinds of soil. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing uPVC pipes (Type-B) confirming to IS 13592 : 1992 including all fittings e.g. plain or door bends, junctions, cowls, offsets, access pieces etc. jointing with solvent cement including cutting holes in walls, floors excavation, refilling and disposal of surplus earth wherever required and making good. (The cost of cutting holes of all sizes in RCC walls, slabs & beams wherever required including making good the same with sealents as required by the engineer-in-charge shall be included in the rate).75 mm diameter
b) 110 mm diameter
Providing and laying uPVC Pipes confirming to IS 4985 : 2000) pressure 8kg/cm2 including jointing with solvent cement, testing excavation, refilling and disposal of surplus earth wherever required complete in all respect. Including making connection with floor trap with necessary fittings. a)40 mm nominal bore.
b) 50 mm dia
Providing, Laying, Jointing by heat fusion technique and Testing of HDPE Pipes (of PE 80 grade as per IS 4984-1995 ). The pipes shall have a working pressure of 8kg/cm2) complete with fabricated/moulded/compression type fittings/saddles & GI supports of pipes where required. A)110mm OD- 8.0 kg/cm²
b)75mm OD- 8.0 kg/cm²
C)50mm OD- 8.0 kg/cm²
d)32mm OD- 8.0 kg/cm²
Providing and fixing sand PVC trap (P trap) of self cleaning design as complete including cost of cutting and making good the cutouts in walls and floors etc. complete 110 mm inlet and 110 mm outlet
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work up to plinth level.1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. (For rain water pipe)
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work up to plinth level.1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. (For rain water pipe)
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. a) PN-20 to 25 pipe , 25mm OD as directed by the site engineer. inernal
b) PN-20 to 25 pipe , 32mm OD as directed by the site engineer.
c) PN-20 to 25 pipe , 40mm OD as directed by the site engineer.
d)PN - 10 Pipe, 50mm OD (SDR-11)
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work,including cutting chases and making good the wall etc. a)PN - 16 Pipe, 25mm OD (SDR-7.4)
b)PN - 16 Pipe, 32mm OD (SDR-7.4)
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.PN - 16 Pipe, 25 mm OD (SDR-7.4) PN - 16 Pipe, 32 mm OD (SDR-7.4)
providing and fixing PPR Unions 25mm dia
PPR Union 32mm
PPR Union 40mm
PPR Union 50mm
Providing, fixing, testing and commissioning of high pressure Float Valves of PN-6 rating for Overhead water tanks 32 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing, fixing, testing and commissioning of insulation on HDPE water tank with layer of class O closed cell Elastomeric Nitrile insulation sheets 15mm thick followed by insulation of 50 mm thick fiberglass insulation (density 48 Kg/cum) all around the tank. the fiber glass insulation shall be protected by 24 gauge aluminium sheet cladding giving proper overlaps & sealing the joints with suitable adhesive compound.
Providing, fixing, testing & commissioning of lever operated gun metal ball valve with SS ball.25mm nominal bore
32mm nominal bore
40mm nominal bore
50mm nominal bore
Providing, fixing, testing and commissioning of Air Release Valves screwed ends with ball valve of approved brand of manufacture, with accessories etc., complete.15mm dia
Providing, fixing, testing and commissioning of Air Release Valves screwed ends with ball valve of approved brand of manufacture, with accessories etc., complete.
Providing, fixing, testing & commissioning of class-O nitral sheet insulation 13mm /19mm thick to hot water pipe and fittings and valves as per manufacturer's recommendations complete to satisfaction of Engineer in charge. a) 25mm dia 13 mm thick
b) 32mm dia 13mm thick
Providing and fixing insulation to Pipes with 50mm thick resin bonded preformed mineral wool pipe sections of density not less than 144 kg/cum. as per IS:9842 and applying 26g Aluminium sheet as cladding, properly rolled and grooved with joints sealed with a strap of roofing felt (type-III Grade-I conforming to IS:1322) complete with self tapping screws centre to centre distance of 150mm to close cladding joints. The pipes shall be painted with zinc chromate primer before applying insulation a) .25mm nominal bore
b) 32mm nominal bore
c) 40mm nominal bore
d)50mm nominal bore
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing, fixing, testing & commissioning of Solar Water Heating system complete with solar panels, insulated SS 304 storage vessel with cemamic lining inside & interconnecting pipes and valves complete in all respect as per manufacturer specifications. Tank shall be supplied without electrical boosters. (Solar heaters shall be equivalent to sholarhart model LCSC Thermosiphon solar heating system and suitable for frost & harsh condition.) The Vendor shall include in this rate cost of all interconnecting pipes and valves & insulations connecting the panels). Capacity 180 LPD (comprising 1 no. collector panel and 180 ltres SS 304 storage vessel)
Providing & fixing M.S. Puddle Flange fabricated of 600 mm long 'C' class pipe pieces with screwed ends with center of pipe welded with 6mm thick M.S. plate of size (100mm+D) X (100mm+D) for R.C.C. water tank walls / slabs. The entire fitting shall be hot dipped galvanised. (D indicated above nominal dia metre of pipe in mm). (for Fire overhead tanks) a)25mm dia.
50mm dia
65mm dia
80mm dia
100mm dia
150mm dia
Providing, fixing, testing and commissioning of 50mm dia G.I. Vent Pipe on Under ground and over head tank inlcuding cost of 2 Nos. 900 bend and painting with enamel paint complete with in all respect 50mm Dia) (for Fire overhead tanks).
Providing, fixing, testing & commissioning of 450x600mm rectangular C.I. Cover (IS : 1726-91) with frame light duty total weight 38 kg. (23 kg. cover and 15 kg. Frame (for Fire overhead tanks).
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 450x300x150 mm
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.(For wash basin)
Providing and fixing CP Brass long body bib cock of approved quality confirming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P brass angle valve for basin mixer and geyser points of approved quality confirming to IS:8931 15 mm nominal bore
Providing and fixing toilet paper holder.C.P. brass
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing vitreous China Sanitary fixturs and CP fitting and other accessaries for Handicapped toilet (Matrix Set-1). Each Matrix Set shall comprised (Wash Basin 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm). complete all respect.
Providing, fixing, testing & commissioning of CP brass Sink Mixer with Swinging Spout (Table Mounted Model) with 450mm Long Braided Hoses equivalent to (JAQUAR Cat. No. CON-309KNM.
Providing, fixing, testing & commissioning of C.P. brass twin robe hooks equivalent to JAQUAR Cat. No. 1161.
Providing, fixing, testing & commissioning of S.S. hinged grating, 1.5mm thick with frame equivalent to JAYNA NEW HEAVY GRATINGS Cat. No. NHG 140 including setting in floor with cement mortar 1:3.
Providing, fixing, testing & commissioning of automatic high pressure electric water heaters equivalent to VENUS with glass lining thermostats with each element and high temperature cut off, necessary insulation, safety valve, etc. all complete. A)15 litres
b)25 litres
Providing, fixing, testing & commissioning of Health Faucet equivalent to JAQUAR Cat. No. ALD-573 make with flexible pipe and wall hook with each European W.C. Pan.
Providing, fixing, testing & commissioning Soap Dispenser equivalent to (JAQUAR Cat No. ACN-1137N).
Providing, fixing, testing & commissioning of 15mm C.P. brass Connection Pipe Jaquar Cat No. ALD-805B (450mm Long Braided Hose with Two 15mm Nuts & Rubber Washers Without Nipple (Suitable for WC, Geysers & Basin Mixers)) or equivalent make union nuts complete with C.P. brass flange including cutting and making good the walls wherever required. (For Angle Valve)
Provding, fixing, testing & commissioning of Reverse Osmosis Unit capacity 25 lph wall mounted (ION EXCHANGE) FONTUS RO regular of approved equivalent. RO shall has following specifications: Flow Rate - 25 LPH Dimensions L X W X H - 270mm x 300mm x 500mm Power Consumption - 60 Wmax. Pressure storage tank- 8 litres / 2.8 Kg/cm2 - HPN tank Minimum Inlet Pressure - 0.5kg/cm2 RO Element - 75 GPD Max Feed water TDS - 1500 ppm Sediment Filter - 10 microns ACF - 10 microns Rejection of TDS (minimum) - 90-95%
Electrical Works, Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group- A
Group- B
Group- C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
d)2 X 6 sq. mm + 1 X 6 sq. mm earth wire
E)2 X 10 sq. mm + 1 X 6 sq. mm earth wire
f)4 X 10 sq. mm + 2 X 6 sq. mm earth wire
G)4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
3 x 6 sq. mm
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 pair
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. b) 25 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cabble
2 run of cable
3 run of cable
Wiring for group controlled (looped) light point/fanpoint/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Group B
Group C
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Double pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. 40A
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB
For 14 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 6 way, Double door TPN MCBDB
For 8 way, Double door TPN MCBDB
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
225 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) with perforation not more than17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 3 output (1output per phase) and suitable for three phase supply
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 6 zone
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Supplying, fixing of heavy duty DLP U-PVC Trunking made Made from Unplasticized Polyvinyl Chloride ( U-PVC ) , rigid and chemically resistant. The quoted rates shall be inclusive of making the surface good as required/ or fixing on wall with box fastners.105 x 50 mm
Supplying, fixing of Box type floor trunking made out of heavy duty Extruded aluminium. The quoted rates shall be inclusive of floor cutting and making the surface good as required/ or fixing on wall with box fastners. 300 x 40 mm
Providing and fixing in position G.I. 65mm x 100mm x 50mm Telephone and Data outlet boxes complete with duplex cover plate & 2 Nos. RJ-45 outlets (For Data & Voice) .
Providing and fixing in position G.I. 65mm x 100mm x 50mm Telephone and Data outlet boxes complete with cover plate & 1 No. RJ-45 outlets (For Data / Voice) .
Supply, installation, testing and commossioning of 2KVA inverter with lead acid batteries with 2 hrs battery back at full load
Supply, laying, installing, testing & commissioning in position of the following size XLPE aluminium / copper conductor armoured cables as per IS: 1554. On cable tray in massonary trench / directly burried in ground. The quoted price shall be inclusive of clamping while laying on tray cost of sand cushioning and brick protection while directly burrying in ground and sadding in case of laying in massoinary trench. 4 x 25 sq. mm Al.cable
Supplying, installing, effecting connection testing and commissioning cable and joints with solderless crimping lugs, double compression glands etc. as required with earthing of cable glands. 4 x 25 sq. mm cable
Electrical Panel Design, manufacture, S.I.T.C of following Panels made of 16 S.W.G.C.R.C.A. sheet, steel dust and vermin proof compartmentalized construction with bus bar chambers, cable alley, cable glands plate etc. as required duly painted from inside as well as out side, as below:- Note:- Derating shall be considered as per environmental conditions of Nubra Valley at Ladakh MAIN L+P PANEL-1 SCIENCE LAB INCOMER 1 Set of 250 Amps. 415 Volts. 4P MCCB of 25 KA with overload, S/C and earth fault protection. MAIN BUS BARS 315-Amps 3 phase 4 wire 415 volts 50 HZ aluminium bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 1 Set of 0-500-V (96 sq.mm) Voltmeter with VSS & protection MCB 1 Set of 0-100-A / 5-A (96 sq.mm) Ammeter with ASS & CT"s. 3 Nos. phase indication lights LED type with protection MCB. 1 Set of LED indicators for Incoming Breaker 'ON', 'OFF', 'TRIP' LED lamps. OUTGOING 3 Nos. 100 Amp TPN M.C.C.B. of 25 KA with inbuilt protection 7 Nos. 63 Amp TPN M.C.B. of 10 KA MAIN L+P. PANEL-1 AS DESCRIBED ABOVE
UPS PANEL INCOMER 1 Set of 63 Amps. 415 Volts. 4P MCB of 10 KA MAIN BUS BARS 100-Amps 3 phase 4 wire 415 volts 50 HZ copper bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 1 Set of 0-500-V (96 sq.mm) Voltmeter with VSS & protection MCB 1 Set of 0-100-A / 5-A (96 sq.mm) Ammeter with ASS & CT"s 3 Nos. phase indication lights LED type with protection MCB. OUTGOING 2 Nos. 40 Amp TPN M.C.B. of 10 KA 6 Nos. 32 Amp DP M.C.B. of 10 KA UPS PANEL AS DESCRIBED ABOVE
VERTICALTYPE DB INCOMER 1 Set of 100 Amps. 415 Volts. 4P MCCB of 15 KA MAIN BUS BARS 160-Amps 3 phase 4 wire 415 volts 50 HZ copper bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 3 Nos. phase indication lights LED type with protection MCB. OUTGOING 3 Nos. 40 Amp TPN M.C.B. of 10 KA 30 Nos. 5-32 Amp SP M.C.B. of 10 KA VERTICAL TYPE DB AS DESCRIBED ABOVE
Supplying, installation testing and commossioning of following MCCB / MCB duly enclosed in M.S. enclosures( Weather Proof) in following capacities with cable end boxes etc. 63 TPN MCB of 10 KA
M/S SONAM RIGZIN
M/S TASLIM AHMED
M/S TSASKAN CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.32 MB
BOQ_21445.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .