Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC | ₹3.1 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹3.3 Cr+₹24.6 L (8.03%)Rejected-Finance | ₹3.3 Cr+₹24.6 L (8.03%) | L2 | Rejected-Finance Highest |
| 3 | Not Admitted-Fee | - | - | Not Admitted-Fee Fee not received |
Tender Value
₹3.0 Cr
EMD Value
₹3.0 L
Closing Date
24 Aug 2021, 6:00 pmClosed
ACE I RHB
Additional Chief Engineer-I Rajasthan Housing Board Jyoti Nagar jaipur
Water supply scheme for Rajasthan Housing Board colony Vatika Jaipur
2021_RHBCE_235933_2
ACE-I_04/2021-22
Open Tender
Civil Works - Water Works
Percentage
365 days
Jaipur
As per NIT
3 documents required · 3 mandatory
₹3,540
As per NIT
₹3.0 L
Yes
6 Dec 2023
5 Aug 2021
27 Aug 2021
5 Aug 2021
24 Aug 2021
5 Aug 2021
Amount
Construction of RCC INTZE type Head Service Reservoir of following capacity and staging consisting of excavation in all types of strata, RCC work, cement plaster with water proofing compound to the inner face of the container including refilling disposing off the surplus stuff, plinth protection , all labour and material charges including providing and fixing of accessories such as ladder , manhole frame and covers, water level indicator (float type), ventilator with SS screen, lightening arrestor, float valve, puddle collar, G.I. pipe railing around walk way and top dome, providing RCC staircase from 4.5 mtr height of ground level to top level, chambers for all valves, providing and applying three coats of cement paint to the external surfaces of container, column, bracing, carbonation paint on external surface of top dome, food grade epoxy paint on internal surface and giving satisfactory hydraulic test and water tightness test as per I.S. code, etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job includes conducting SBC test, design and proof check of reservoirs (if required),painting the name of the scheme and other details on the reservoir, providing alluminium portable ladder suitable to reach at height of 4.5 Mtr(start of RCC reservoir) and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work . RCC OHSR, SBC 10T/sqm, seismic zone II and Staging 20 Meter
Construction of RCC Clear Water Reservoirs of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top roof slab and food grade epoxy paint to inner face of the container and slab, including refilling and disposing of surplus stuff , all labour and material charges, providing and fixing accessories such as M.S./Alluminium ladder/RCC Stairs inside and outside, manhole frame and cover, puddle collar, ventilators, satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints on all exposed surface of structure etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job include painting the name of the scheme and other details on the reservoir and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. Notes The rate indicated below are excluding the cost of pipes, specials and valve required for inlet, outlet, washout, overflow piping arrangement, but inclusive of DI puddle collar for inlet, outlet, overflow and washout pipe of appropriate sizes to be embedded in concrete. RCC Circular Flat Slab CWR, SBC 10T/sqm, seismic zone II .
Conducting Geo physical Resistivity electric survey for pin pointing of Tube well ( 2 point each tube well)
Providing & Installation Testing commissioning Horizontal split case pumps totally enclosed fan colled motors coupled with pump & necessary base plates coupling and foundation bolt etc on concrete foundation / RSJ with accurate level ling and proper alignments complete discharge of pump 25 LPS head 40 Mtr. (bronze impeller) make : Kirloskar, Motor : C & G taking combind efficiency 55% (2 working + 1 stand by).
Supply, Erection, testing and commissioning of suitable size made out of 18 gause painted sheet canopy type out door LT panel board, (2+1) (PMCC) conforming SLD and specification suitable for 25 LPM 40 mtr. Head for mono block motor pumps 2 nos. Spare details component 6 Nos contractor, 3 Nos MCB with controlling fuse, single phase preventer 2 nos, overload relay 2 nos, AMP mtr 3nos, volt mtr, CT 9 nos, capaciter per feeder (for maintaing power factor) Make telemecanique/L&T or equivalent make and direction engineer incharge. (2 working + 1 stand by).
Supply, installation operation & maintenance of chlorine dioxide COD 5000 based Non Electricty based Dosing pump driven by water for disinfection of water on regular basis at pump house including all chemicais and recurring expenditure during DLP
Supply, fixing, commissioning of dosatron non electricity based water powered liquid dispenser dosing pumps with chlorine dioside disinfectant with all installation materials and specials like rotameter, cartridge, upvc pipe fittings, adopter, bends valves, sockets, NRVs etc. as per specification in VOL. Including transportation, loading, unloading etc. at sector 5 & 8 and sector 26, Pratap Nagar, Jaipur with includes construction of safe space / arrangements/room to accomodate above dosing pump. Cost for 1 No. Dosing pump
CDD 5000 Chlorine Dioxide (CLO2) in powder form of minimum 5000 ppm per liter as per DIN EN 12671, the chlorine Dioxide should be 100% soluble in water as per specification in Vol. Total quantity for on year treatment of 25 to 36 lacs liter of water per day at Pratap Nagar sector 5 & 8 and 26 Distribution centers for dose resulting 0.06 ppm Required for CLO2 powder qty. for 2 nos. dosing pump 1100 Kg
Providing Steel tubular office chair with cane seat and back made of ERW 1/14 gauge pipe with half hanging arms.
Providing Woden stool ordinary size 38x38x45 cm
Providing table of size 175x90x75 as per detailed specifications.
Providing for Office almirah with locker 78"x36"x19"
Providing for Wisdom Seatings Heavy USE Visitor Chair
Providing for Octave Office Executive Visitor Chair in Black
Provision for O&M of scheme including T&P, reparing of pipe line with material and reparing of motor pump and supply of water through tankers (in required) complete in all respect for one year
Bidder Name
Amount
M/s anil kumar gupta(GSTN-08ABOPG2014M1ZM)
P M Construction Company(GSTN-08ABIPY8298F1ZR)
P M Construction Company
P M Construction Company
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .