Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.3 LAccepted-AOC | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹23.7 L+₹2.4 L (11.4%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹24.5 L+₹3.2 L (15.1%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹32.1 L+₹10.8 L (50.9%)Rejected-Finance | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹34.3 L+₹13.0 L (61.2%)Rejected-Finance | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
10 Jul 2024, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
REPAIR / REPLACEMENT OF INTERNAL WIRING WITH REPLACEMENT OF FITTING AND FIXTURES AND CONNECTED WORKS AT SUNJUWAN UNDER GE JAMMU
2024_MES_658861_1
GEJC-23/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE Jammu
₹1 L
Yes
30 Aug 2024
13 Jun 2024
12 Jul 2024
13 Jun 2024
10 Jul 2024
27 Jun 2024
Amount
Charges for attending day to day/ E/M petty complaint for OTM/Md accn in respect of repair/rectification of fault in electric fitting MCB DBs, internal wiring LT Panel and fixture and rectify the faults and replacement of unserviceable any type of fitting/fixture, MCB's, any type, bakellite sheet restore the electric supply and made the item functionable light point, fan point, socket point 5A/15A, switches sockets, fan regulator, light fixtures any type of lamp, MCB DB's and all electrical accessories and day to day /door to door maintenance, making the points/accessories serviceable in all respect with replacement of any minor parts like small length of wires (not more than 1 metre) and other connected minor accessories. Work shall also include to check and removal of leakage in service connection/submains of houses as and when directed. The scope also include cutting of existing bakelite sheet to accommodate new wiring acessories all type of electric fitting/fixture. Notes: - Any other replacement of major items shall be measured and paid under respective items as supply only. Fixing charge of fitting/fixture and MCB's of any type is deemed to be included in the above item. (i) Contractor representative/Engineer will report to complaint cell in morning at 9:00 am to collect routine/urgent nature of complaint related to internal electric supply and shall submit the complaint resolve report at 5:00 pm, till completion of contract. The work shall be attended by the contractor immediately. The contractor will ensure availability of manpower (two electrician and two helper) equipped with all sorts of petty items such as insulation tape, galvanised screwes, nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure availability of every type of requisite T&P items to his tradesman. All routine/urgent job received on job slip will be repaired and got signature of user's and will be deposited to complaint cell within 24hrs. In case of any delay in attending the complaint more than 12hrs after handing over of routine/urgent works, the contractor shall be liable to pay the penalty as per the item rate. (ii) Contractor shall maintain the maintenance register showing all daily complaints received and shall maintain job card for attending complaints. The signature of the user shall be obtained on the job card showing the materials used in the work after completion of the job. (iii) If the Contractor did not attend complaints, a penalty of Rs 300/- per day per complaint recovery shall be made from the work done amount. (iv) The MES Department is not responsible for the payment of staff hired by contractor for complaint rates for attending the complaints by the electrician are deemed to be included in the item for repair i.e. Electrician/Helper, as all the items of CA are to be supply and fixed by the contractor. (v) Proper record (date wise) of complaints received and rectified by the contractor shall be produced for verification at the time of payment of each RAR/Bill. (vi) All the complaint slip, register and connected documents will be provided by the contractor without any extra cost. (vii) After any repair the site has to be cleaned and make the surface good.
Supply only switch piano, flush type single pole one way 5 Amp, 240 volts ISI marked complete all as specified and directed.
Supply only socket outlet 2 in 1, 3 pin, 5 A complete all as specified and directed.
Supply only switch socket outlet combined 5 pin 5 amp flush type, 240 volts ISI marked complete all as specified and directed.
Supply only switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 volts ISI marked complete all as specified and directed.
Supply only socket outlet 3 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete ISI marked complete all as specified and directed.
Supply only switch piano, flush type single pole one way 15 Amps, 240 volts ISI marked complete all as specified and directed.
Supply only ceiling rose 3 terminal surface type complete all as specified and directed.
Supply only lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply only bell, AC 230 Volts single pole complete all as specified and directed.
Supply only bell push flush type single pole one way 5 amp complete all as specified and directed.
Supply only MCB SP 6 to 32 Amps, 240 Volt 'B' series complete all as specified and directed.
Supply only SPN 32 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only SPN 40 to 63 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed.
Supply only insulation tape roll of different colours as per sample complete all as specified and directed.
Taking down old unserviceable copper / aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden/iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Material and labour for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid / steel conduit and into existing CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Notes: - (a) Wiring shall be done by using proper colour coding including making the disturbed surface good. (b) Earth wire shall be of green colour. (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description all as per Ser item No 18.00 here-in-before but for one 5 pin socket outlet 5 amps on the same board complete all as specified and directed.
Description all as per Ser item No 18.00 here-in-before but for one 5 pin socket outlet, 5 amps, independent complete all as specified and directed.
Description all as per Ser Item No 18.00 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and directed.
Material and labour for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including new cast iron / pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Notes: - (a) Wiring shall be done by using proper colour coding including making the disturbed surface good. (b) Earth wire shall be of green colour. (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description all as per Ser item No 22.00 here-in-before but 5 pin socket outlet on same board complete all as specified and directed.
Description all as per Ser item No 22.00 here-in-before but socket outlet 5 amps, independent board complete all as specified and directed by Engineer-in-Charge.
Description all as per Ser Item No 22.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and directed.
Description all as per Ser item No 22.00 here-in-before but drawn through and including new surface conduit PVC rigid non-metallic conduit 20mm dia for socket outlet 5 amp independent board complete to accommodate the accessories for PVC gang box all as specified and directed.
Description all as per Ser Item No 22.00 here-in-before but drawn through and including new surface conduit PVC rigid non-metallic conduit 20mm dia for socket outlet 15 amp independent board complete to accommodate the accessories for PVC Gang box all as specified and directed.
Supply and fixing switch piano, flush type single pole one way 5 Amp, 240 volts ISI marked complete all as specified and directed.
Supply and fixing socket outlet 2 in 1, 3 pin, 5 A complete all as specified and directed.
Supply and fixing switch socket outlet combined 5 pin 5 amp flush type, 240 volts ISI marked complete all as specified and directed.
Supply and fixing switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 volts ISI marked complete all as specified and directed.
Supply and fixing socket outlet 5 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete ISI marked complete all as specified and directed.
Supply and fixing switch piano, flush type single pole one way 15 Amps, 240 volts ISI marked complete all as specified and directed.
Material and labour for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including modular metal flush boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc complete all as specified and directed for the following: - Notes: - (a) Suitable Modular white cover sheets with frame as specified to be provided in replacement of mild steel / galvanised sunken boxes and measured and paid separately as per relevant item. (b) Wiring shall be done by using proper colour coding including making the disturbed surface good. (c) Earth wire shall be of green colour. (d) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description all as per Ser item No 34.00 here-in-before but 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per Ser item No 34.00 here-in-before but socket outlet 5 Amps independent board complete all as specified and as directed by Engineer-in-Charge.
Description all as per Ser Item No 34.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and directed.
Supply and fixing in repairs modular switch 1 way 6 A, 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular socket, 6 A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular socket 6 A / 16 A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular fan step regulator, 120 W, 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular metal flush box ½ module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular metal flush box 3 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular metal flush box 4 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular metal flush box 6 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular metal flush box 8 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular metal flush box 12 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular white cover plate with frame 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular white cover plate with frame 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular white cover plate with frame 3 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular white cover plate with frame 4 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular white cover plate with frame 6 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular white cover plate with frame 8 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs modular white cover plate with frame 12 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in repairs distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud TPN 4 way 415 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in repairs distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in repairs distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in repairs distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in repairs MCCB 4 pole, 415 Volt fixed thermal and fixed magnetic setting of capacity 125 Amps 16 KA complete all as specified and as directed.
Supply and fixing in repairs 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in repairs 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 Amp, in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing SPN 32 Amp rating 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing SPN 40 to 63 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing 415V 10 KA 'B' curve TPN 40 to 125 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply only calling bell ding dong / buzzer, AC 230 Volts single pole complete all as specified and directed.
Supply only stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed.
Supply and fixing for bell push, flush type single pole, 5 Amp, 240 volts complete all as specified and as directed.
Supply and fixing ceiling rose 3 terminal surface type complete all as specified and as directed.
Material and labour in repair for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Material and labour in repairs Self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed.
Supply and fixing in repairs LED lights fitting 1 x 20 W, 220 V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95, 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4' ft long) with LED rod 20 watt, 230 Volts 50 Hz complete all as specified and as directed.
Supply and fixing in repairs LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing in repairs bulk head luminaries IP-65 with opal diffuser 10 watt, 230 Volts LED type complete with 10 watt LED bulb complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Material and labour in repairs for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in repairs for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in repairs for copper cable for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed.
Material and labour in repairs for copper cable for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 metre deep below normal ground level with top edge of the earth plate not less than 1.5 metre below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 precast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and as directed.
Supply and fixing in repairs Bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (06 No's each) of size 8''X5'' complete all as specified and directed.
Supply and fixing in repairs Bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (12 No's each) of size 12''X10'' complete all as specified and directed.
Supply and fixing in repairs Bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (02 No's each) of size 5''X5'' complete all as specified and directed.
Supply and fixing in repairs plug top 15 Amps complete all as specified and directed.
Supply and fixing in repairs of Vertical Distribution Board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing MCB's and should be IP-43 protected with copper bus bars, neutral links, earthing bar all as specified and directed including taking down old unserviceable distribution board / MCB any type complete all as specified and as directed. Notes: - (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 volts with adjustable thermal settings. (ii) MCB's shall be measured and paid separately. (iii) TPN distribution board and MCCB should be of same make.
Supply and fixing in repairs PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin 5 amp 240 volt alongwith switch piano 5 amp 240 volt complete all as specified and as directed.
Supply and fixing in repairs PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin 5 amp 240 volt alongwith switch piano 15 amp 240 volts complete all as specified and as directed.
BMMJ TRADERS AND ENGINEERS
M/S RAVINDER SINGH
M/S Sukhmani Construction Co.
DARVESH ENGINEERING WORKS
Sarbat Construction Co
M/s Sahib Construction and engineers
VEE ESS ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .