| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L1 | Accepted-AOC Accepted due to lowest rate quoted | |
| 2 | L2₹24.4 L+₹46,060 (1.92%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L2 | Rejected-Finance Rejected due to highest rate quoted | |
| 3 | L3₹27.1 L+₹3.1 L (13.1%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L3 | Rejected-Finance Rejected due to highest rate quoted | |
| 4 | L4₹28.2 L+₹4.3 L (18.0%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L4 | Rejected-Finance Rejected due to highest rate quoted | |
| 5 | L5₹28.8 L+₹4.8 L (20.1%)Rejected-Finance | L5 | Rejected-Finance Rejected due to highest rate quoted |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
18 Oct 2024, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR REPLACEMENT AND MAINT OF LT PANELS LIGHTENING ARRESTOR UG CABLES APFC PANELS VOLTAGE STABLIZER TPN DBs SERVICE CONNECTION AND OTHER E/M ALLIED WORKS AT AF STN ARJANGARH AND PERIODICAL MAINTENANCE AND SERVICING OF COOLING APPLIANCES REFRIG
2024_MES_675631_1
GE/GUR-/NIT-26/2024-25
Open Tender
Civil Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹75,000
10 Dec 2024
20 Sept 2024
21 Oct 2024
20 Sept 2024
18 Oct 2024
4 Oct 2024
Amount
M & L for opening the bus bar and rear/front panel of LT Panel board (01 No incoming and 09 to 15 Nos outgoing), disconnecting the cables from the busbars, replacement of suitable size of aluminium lugs of various size (25 sq mm to 300 sq mm) through hydraulic crimping method, replacement of burnt out nuts/bolts, replacement of cable glands, replacement of internal wiring, replacement of partially burnt out bus bar (if required) taking down carefully the copper/aluminium bus bar as required at site, scrapping the bus bar by emery paper for removing the silt/carbon, replacement of PVC insulation tape (RYB) and assembling the bus bar, LT Panel board complete for testing complete all as specified and as directed.
All as per item No. 01 above but of (01 No incoming and upto 8 Nos outgoing)
All as per item No. 01 above but of (01 No incoming and upto 06 Nos outgoing)
All as per item No. 01 above but of (01 No incoming and upto 04 Nos outgoing)
M & L for scrapping the old painted surfaces and spray painting of HT/LT panel board of size upto 6 m x 2.5m x 1 m with two coats of synthetic enamelled paint of approved colour complete with all fittings etc complete all as specified and as directed. (Note rate quoted by the contractor deemed to be included the writing of outgoing and incoming feeder etc).
All as per item No. 05 above but of size 3 m x 2 m x 1 m.
All as per item No. 05 above but of size 2 m x 2 m x 0.75 m .
M&L for Fabricate, Supply install test and commissioning in repair of Feeder pillar box (Out door type) of size 50 cm x 50 cm x 25 cm (L x H X B) suitable for 440 Volt, 3 phase & Neutral , 50Hz supply, floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet with gland plates at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including with suitable size aluminium bus bars 200 Amps 04 Nos in its full width (35 cm length) to be fixed on suitable size of insulators. The bus bar having 06 Nos of holes including provision of suitable size of nuts and botls of all four bus bars, the feeder pillar box shall be floor mouted with provision of four nos of legs made out of 50 x 50 x 5 mm MS angle not less than 40 cm and shall be grouted under PCC 1:2:4 complete all as specified and as directed.
M&L for Maintenance / repairs to APFC panels, 3 phase AC 415 V, by skilled technician and replacement of unserviceable spares as specified below for capacities 40 to 200 KVAR including replacement of short circuited copper conductor cables with appropriate gauge PVC insulated stranded copper conductor cables and cleaning of all moving contacts of relay contactors, tightening of all terminals and testing afer repairs to ensure serviceability and corrected output at specified powerfactor complete all as specified and as directed.
M&L for Dismantling Air Circuit Breaker 4pole/3pole, 630 to 2000 Amps 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil,no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and as directed. Note : Spare parts will be measured and paid separately.
Supply , fix ,test and commissionning in repair in existing panel APFC Relay, 12 Stages digital type suitable for 415V, 3phase, AC supply complete all as specified and as directed.
Supply and install capacitor metalized poly propylene ultra heavy duty (LTXL) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15%. complete all as specified and as directed of following sizes:-
(a)25 KVAr.
(b)20 KVAr.
(c)10 KVAr.
(d) 5 KVAr.
(e) 2KVAr.
Supply and fix on load "AUTOMATIC MOTORIZED CHANGE OVER SWITCH" of capacity 400 A, 4 Pole , 415 Volts, 50 Hz as per IEC-60947, complete with add on block bridge with function of auto and manual switch and with handle to operate manual including necessary connection with contactors and delay timer complete all as specified and as directed.
Supply and fix on load "AUTOMATIC MOTORIZED CHANGE OVER SWITCH" of capacity 630 A, 4 Pole , 415 Volts, 50 Hz as per IEC-60947, complete with add on block bridge with function of auto and manual switch and with handle to operate manual including necessary connection with contactors and delay timer complete all as specified and as directed.
Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 10 Sqmm nominal cross section x 4 core complete all as specified and as directed.
All as per item no. 15 above but Size 16 Sqmm X 4 core.
All as per item no. 15 above but Size 25 Sqmm X 4 core.
All as per item no. 15 above but Size 50 Sqmm X 3.5 core.
All as per item no. 15 above but Size 95 Sqmm X 3.5 core.
All as per item no. 15 above but Size 185 Sqmm X3.5 core.
All as per item no. 15 above but Size 240 Sqmm X3.5 core.
M&L for searching fault location of HT/LT UG cable 11000/415 Volts laid in trenches/ducts with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with frequency distance calculator etc incl transportation of machinery. Excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re-fixing cables with lugs complete all as specified and as directed.
Supply and fix ON load four pole changeover switch with front handle operated of 4 pole 415 volt 50 Hz 630 amps in open execution to be fixed in existing panel with suitable size nut/bolts complete all as specified and as directed.
Supply and fix ON load four pole changeover switch with front handle operated of 4 pole 415 volt 50 Hz 400 amps in open execution to be fixed in existing panel with suitable size nut/bolts complete all as specified and as directed.
Supply & Fixing in repair including making connection testing and commissioning of new MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and as directed.
All as per item No. 25 above but MCCB TP 125 Amps, 415 Volts, 36 KA, 50 Hz complete with extended terminals and PVC spreader complete all as specified and as directed.
All as per item No. 25 above but MCCB TP 250 Amps, 415 Volts, 36 KA, 50 Hz complete with extended terminals and PVC spreader complete all as specified and as directed.
All as per item No. 25 above but MCCB TP 400 Amps, 415 Volts, 36 KA, 50 Hz complete with extended terminals and PVC spreader complete all as specified and as directed.
All as per item No. 25 above but MCCB TP 630 Amps, 415 Volts, 50 KA, 50 Hz complete with extended terminals and PVC spreader complete all as specified and as directed.
All as per item No. 25 above but 4 Pole, 125 Amps, 415 V, 25 KA, 50 hz complete with extended terminals and PVC spreader complete all as specified and as directed.
All as per item No. 25 above but 4 Pole, 200 Amps, 415 V, 25 KA, 50 hz complete with extended terminals and PVC spreader complete all as specified and as directed.
All as per item No. 25 above but 4 Pole, 400 Amps, 415 V, 36 KA, 50 hz complete with extended terminals and PVC spreader complete all as specified and as directed.
All as per item No. 25 above but 4 Pole, 630 Amps, 415 V, 50 KA, 50 hz complete with extended terminals and PVC spreader complete all as specified and as directed.
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete all as specified and as directed.
Supply and fixing of GI tubing, light grade, 80 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete all as specified and as directed.
Supply and fixing of GI tubing, light grade, 100 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete all as specified and as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 25 to 50 sq mm complete all as specified and as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 70 to 150 sq mm complete all as specified and as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 185 to 300 sq mm complete all as specified and as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 400 sq mm complete all as specified and as directed.
Supply and erecting in true vertical position steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9 meter long) complete as per IS 2713, Including disconnecting and taking out old damage PCC pole complete all as specified and as directed. Note :- Necessary earth work and PCC will be measure and paid seperately under relevant items.
Supply and fixing prestressed concrete pole 9 meters long 102 mm x 152 mm at top and 102 mm x 289 mm at bottom of class 10 complete, Including disconnecting and taking out old damage PCC pole complete all as specified and as directed. Note Earth work and PCC shall be measured and paid separately as these respectively.
M & L for Painting of steel pole with cross arms, clamp of any length and shape for LT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbersand marking three blue & three white bends width 20 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height complete all as specified and as directed.
S&F Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for LT size 20 X 15 Cm fix in repairs complete all as specified and as directed.
M& L for removal and demoltion of old u/s RCC cable trench cover of any size and any description and retrieved of old u/s reinfocement complete all as specified and as directed.
S&F in repair for mild steel plates (plain or chequered) of Grade Fe 410-W (Gde-E-250) Quality 'A' for covering the cable trenches/cable ducts of described size complete with arrangement of lift hooks with provision of four Nos holes complete all as specified and as directed.
Suuply and fixing street light brackets made out of GI tubing light grade, 40 mm bore 1200 mm long bent to sahpe at 120 degree, fixed on pole by providing MS clamp made up to flat iron 50 x 6 mm including nuts and washer of suitable size, fixed in repairs complete all as specified and as directed.
M&L for pole painting, concrete pole with 02 coat of wheather exposed dust proof "apex" emulsion, pole height should be 9/11 mtr. Painting should be done from top to bottom at ground level. Bottom portion of the pole upto 1.50 m from top of the copping with one coat of synthetic enamel paint with marking pole numbers & marking three blue & two white strips width 25 cm by fluorescent paint complete all all as specified and as directed .
Supply ,install testing and commisioning of maintenance free chemical earthing system conforming to IS: 3043 using 77mm dia 3000mm long copper rod with exothermic T point rod with long copper strip of size 50mm x 6 mm and 90 mm dia terminal pipe of thickness 1.6 mm and 3000 mm long with copper test certifcate 99.99%. The ground enhancing compound made of Marconite conductive aggregate (consist of Marconite resin-based cements, adhesive and gypsum plasters) shall not be less than 45 kg. The electrode shall be provided on its top with an earth termination clamp made out of electrolytic grade copper for connecting earth continuity conductor with copper wire. PCC chamber of size 300x300x300 mm with cover shall be provided on the top of the earth system on 100 mm thick PCC 1:3:6 bed concrete . The chamber shall burried in ground with top edge projecting upto 75 mm from ground surface complete all as specified and as directed. Note:- i) The quoted rate shall include cost of copper strip 50mm x 6 mm upto 7.5 m length and bore in hard/disintegrated rock. ii) The earth resistance shall not be more than 01 ohm . iv) the size of bore should not be less than 1500 mm dia.
M & L for Earthing to OH/Sub stn with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI wire 4 mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 1991, GI earth lead wire protected by GI pipe 15mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI medium grade and provision of earth test point including testing on completion Note : Main earth lead beyond 7.5 meter shall measured and paid saperatly.
All as per above item No - 50 above but main earth lead 32 x 6 mm galvanised iron strip.
All as per item No 50 above but using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead.
M & L in repair for Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall in repair complete all as specified and as directed.
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.
M & L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed.
M&L for Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed.
Supply and fix epoxy insulators 25 mm dia base with suitable screws complete for fixing AL strip if size 25x3.15 mm complete all as specified and as directed.
Supply and fix porcelain insulator (white colour) for running of GI/Aluminium/Copper strips of size 32/20/25 mm including suitable size of screws for fixing vertically/horizontal plane at any height and making suitable size holes on strips including nut/bolts/wahsers etc complete all as specified and as directed.
M & L for Air termination of Lighting conductors, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed .
M & L for Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and as directed .
Excavation of soft/loose soil in trenches not exc 1.5 meter wide & not exc 1.5 mtr in depth: for foundationetc or for manholes, laying of pipe in any type of soil and getting out complete all as specified and as directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and as directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and as directed.
M & L for Old size sub class ‘B’ bricks, laid in trenches as cable covers complete all as specified and as directed.
M & L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass complete all as specified and as directed.
M & L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and as directed.
M & L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and as directed.
Supply and fill of back feel compound in earth pit complete all as specified and as directed.
S & F in repair sub main wiring for circuit of size 6 sq mm 2 core (FRLS) alongwith earth wire of 6 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor in existing PVC conduit complete all as specified and as directed.
S & F in repair sub main wiring for circuit of size 4 sq mm 2 core (FRLS) alongwith earth wire of 4 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor in existing PVC conduit complete all as specified and as directed.
Supply and fixing in repair TPN DB's 8 way vertical type 415 V, double door suitable for housing of 125 Amps MCCB as main incoming complete all as specified and as directed.
All as per item No. 72 above but of 4 way and suitable for housing of 100 A/63 A MCCB as main incoming complete all as specified and as directed.
S & F MCCB 125 Amps capacity, 4 pole, 25 KA, fixed thermal and magnetic release complete with extended terminals to be fixed in 8 way TPN DB complete all as specified and as directed.
All as per item No. 74 above but capacity 100 Amps, fixed thermal and magnetic release, 4 Pole, 25 KA suitable to be fixed in 4 way TPN DB complete all as specified and as directed.
Suply and fixing 240 V, 10 KA, 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity SP 5-32 Amps in the MCB DB complete all as specified and as directed.
Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 10 Sqmm nominal cross section x 2 core complete all as specified and as directed.
S & F in replacement enviroment friendly recess/pendent mounting LED flat panel 2'x2' fabricated CRCA sheet steel housing cool white with high efficient LEDs & glare free opal diffuser (40 W) PF>0.95 driver life >25000 Hours, operating range 140v to 280 V including all accessaries complete all as specified and as directed.
Supply and fixing in repair LED street light fittings 70 watts 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including therma; management in multiple optics complete with IP 65/66 protection complete with provision of twin core teisted copper wire 23/0.0076 upto security light from pole loop boxcomplete all as specified and as directed.
Supply and fix in replacement double door TPN DBs 4 way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site required complete all as specified and as directed.
S & F in replacement with MCB TPN 32 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed.
S & F in replacement with MCB TPN 50 to 63 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed.
S & F pole box for street light dust and vermin proof with hinged door and locking arrangement make Sintex model GSJB 3020 complete with 4 way connector 2 Nos. of capacity 60 amps incl one MCB SP C series 06 amps 10 KA capacity for Security light connection with flexIble wire 3 core 2.5 sqmm with suitable size of PVC conduit and including suitable clamps & suitable size brass chrome plated glands-02 nos at bottom for cable entry and exit complete all as specified and as directed.
M&L for Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed. (for loop boxes and fixing of GI pipe with pole)
M&L for Comprehensive maintenance of electric water heater storage type of capacity 25/50 Ltrs, 230 volts single phase AC and descaling of inner tank of geyser ,insluding brazing /welding if required ,replacement of worn out parts,re-assembling and refixing on site ,including preparation of surface of geyser and painting with 2 coat of white enamelled paint by spray painting machine complete all as specified and as directed. Note :- Spares parts will be measured and paid seperately under respective items.
S&F in replacement of geyser assembly 06/09 holes with washer suitable to fix thermostate , heating element of the existing size including clamps with bolts and nuts etc complete all as specified and as directed.
S&F in replacement of heating element 2000 watt capacity triangular/circular type complete all as specified and as directed. .
S&F in replacement of thermostate suitable for 25/50 Ltrs storage type water heater complete all as specified and as directed. .
S&F in replacement of light indicator (Red & Green colour) suitable for 25/50 ltrs water heater complete all as specified and as directed.
M&L for Comprehensive maintenance of electric Desert cooler , 230 volts single phase AC having nominal air flow capacity of 4000 cfm and cleaning inside the surface including brazing /welding if required ,replacement of worn out parts,re-assembling and refixing on site ,including preparation of surface of Desert cooler and painting with 2 coat of white enamelled paint by spray painting machine complete all as specified and as directed.
S&F in replacement of 12"/18" , 230 volts , single phase fan motor and frame of desert cooler with copper winding complete all as specified and as directed.
M&L replacement of Bush bearing of fan motor for 12"/18" desert cooler complete all as specified and as directed.
M&L for replacement of tullu pump with suitable size PVC pipe for desert cooler complete all as specified and as directed.
M&L for replacement of fan motor blade suitable size of desert cooler complete all as specified and as directed.
M&L of cotton wood pad set of superior quality for desert cooler complete all as specified and as directed.
M&L for Servicing, Oiling, Greasing and Cleaning of window type/ split type AC, 1.5/2 Ton with high pressure pump of any capacity, checking of defects/ leakage of gas and adjusting setting to work and testing complete all as specified and as directed.
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of window/ split type AC 1/1.5/2 Ton capacity complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of Sch "A"
S&F in replacement of new indoor unit of split AC of capacity 1.5/02 ton with suitable for existing out door unit from authorized dealers of company complete all as specified and as directed.
S&F in replacement of new outdoor unit of split AC of capacity 1.5/02 ton with suitable for existing indoor door unit from authorized dealers of company complete all as specified and as directed.
M&L for replacement running capacitor of existing makes and capacity duly ISI marked for Window / split type AC, 1/1.5/2 Ton capacity complete all as specified and as directed.
M&L for replacement of starting relay of existing makes and capacity duly ISI marked for window / split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
M&L for replacement starting capacitor of existing make and capacity duly ISI marked for window type A/C 1.5 ton and split type AC 1/1.5/2 ton capacity complete all as specified and as directed.
S&F in replacement of Electronic control (PCB) of existing makes and capacity duly ISI marked for Window and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for Window and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
S&F in replacement of blower motor for window/split type AC of capacity 1.5/2.0 Ton complete all as specified and as directed.
S&F in replacement of new rotary type AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 1.5/02 Ton capacity complete all as specified and as directed.
S&F in repair replacement new sealed compressor reciprocatng type suitable for split/ window type AC, 1.5/02 Ton capacity single phase, 230 Volt, 50 Hz in and including refilling refrigerant gas R-22 filling up to required pressure and testing complete all as specified and as directed.
S&F in replacement of Evaporator coil for Window and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
S&F in replacement of Suction/Discharge valve for Window and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
S&F in replacement of Copper tube for 1.5 /2.0 Ton split AC 1/4 complete all as specified and as directed.
S&F in replacement of Copper tube for 1.5 /2.00 Ton split AC 1/2 complete all as specified and as directed.
S&F in replacement of Copper tube cover complete all as specified and as directed.
Material and labour for PVC drain pipe rigid and flexible 20mm dia with clamps of suitable size as per site requirement complete all as specified and as directed.
S&F in replacement of insulation pipe size ¾” or 1” dia for split AC 1.5 / 2 Ton complete all as specified and as directed.
M&L for shifting/relocating of split/window type AC 1.5/2 Ton from one location to another location as required including all connected works complete all as specified and as directed. Note :- (i) The cost of dismantling and refixing of Split/Window type AC deemed to be included in unit rate.
M&L for servicing, oiling, Greasing and Cleaning of water cooler of any capacity with high pressure pump , checking of defects/ leaking and adjusting setting to work and testing complete all as specified and as directed.
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of any capacity complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of Sch "A" (iv) Refilling and toping up of refrigenrant (type and quantity) as required on site is measured and paid separately.
S&F compressor reciprocating type (hermetically) sealed for capacity 40/80/160 litre water cooler complete all as specified and as directed.
S&F in repair of thermostat switch suitable for existing water cooler any make and capacity complete all as specified and as directed.
M&L in replacement for starting relay and overload relay suitable for existing size and make water cooler complete all as specified and as directed.
M&L in replacement for starting capacitor for water cooler suitable for existing size & make water cooler complete all as specified and as directed.
M&L in replacement for running capacitor suitable for existing size & make water cooler complete all as specified and as directed.
M&L for Dismantling of old defective condenser fan motor of water cooler of any make and capacity and refixing and testing the same after rewinding with super enameled copper wire of existing gauge including replacement of shaft/ bush etc complete all as specified and as directed.
S&F in replacement for fan blade of condenser motor of any make and capacity of water cooler complete all as specified and as directed.
S&F of wastage water tray of any capacity of water cooler complete all as specified and as directed.
M&L for servicing of deep freezer any capacity and size by cleaning greasing including painting with one coat of super synthetic enameled paint including preparation of surfaces complete all as specified and as directed.
S&F of starting relay of deep freezer of any size & make complete all as specified and as directed.
M&L for gas charging in deep freezer any make and capacity including testing of leakage complete all as specified and as directed.
S&F of thermostat switch for deep freezer any make & capacity complete all as specified and as directed.
M&L for servicing, oiling, cleaning greasing of refrigerator any capacity including replacement of following unserviceable parts, starting relay - 01 No., over load relay-01 No, capacitor 20 mfd -01No, thermostate switch - 01 No, Door rubber beeding set - 01 Set complete all as specified and as directed.
S&F in repair replecement new sealed compressor suitable for Refrigerator of any capacity single phase, 230 Volt, 50 Hz in and including refrigerant gas filling up to required level complete all as specified and as directed.
Supply & fix in replacement ceiling fans complete with accessories 230 V,1200 mm sweep. BEE 5 star rated complete all as specified and as directed.
Supply & fix in replacement exhaust fans single phase 230/ 240 V of size 300 mm sweep with louver Steel body complete all as specified and as directed.
M&L for rewinding of following fans with same gauge of super enameled copper wire complete varnishing ,baking ,connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with nuts /bolts/washer /split pin and blade screw s etc testing , complete all as specified and as directed for the following:-. NOTE: (i) Spare parts like bearing,capacitor,bushes if required will be measured and paid separately. (ii) The rates shall be deemed to include dismantling of fan and reassembling after repair /replacement of worn out parts.
Ceiling fan 1200 /1400 mm sweep .
Exhaust fan 300 mm sweep .
Exhaust fan 450 mm sweep .
Wall mounted fans 400 mm /450mm sweep.
Supply and fix in repair ball bearing suitable for the following fans : Make :-NBC/SKF/Tata
Ceiling fan 1200 /1400 mm sweep .
Exhaust fan 300 mm sweep .
Exhaust fan 450 mm sweep .
Wall mounted fan 400 mm sweep .
Supply and fix in repair capacitor 2.5 mfd, 230 volt ,50 hz all as specified and as directed. Make : Tibcon or equivalent as approved by GE.
Supply and fix in repair capacitor 3.15 mfd, 230 volt ,50 hz all as specified and as directed. Make : Tibcon or equivalent as approved by GE.
Supply and fix in repair capacitor 4 mfd, 230 volt ,50 hz all as specified and as directed Make : Tibcon or equivalent as approved by GE.
M&L for servicing, cleaning of RO water purifier of any make/size and capacity with high pressure pump, checking of defects/adjusting setting to work and testing complete all as specified & as directed.
S&F in replacement of RO water purifier candle of existing size and make complete all as specified and as directed.
S&F in replacement of RO water purifier membrane of existing size and make complete all as specified and as directed.
S&F in replacement of RO water purifier booster pump of existing size and make complete all as specified and as directed.
S&F in replacement of RO water purifier PVC inlet/out pipe of existing size and make complete all as specified and as directed.
M/S Rohit Enterprises (BID ID -3136691)
YASHVI ENGINEERS (BID ID -3136780)
akhil enterprises (BID ID -3142796)
A B K Enterprises (BID ID -3135290)
H.B. Traders (BID ID -3136370)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .