| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹83.0 LAccepted-AOC AZADGARH 1150 9 124001 | ROHTAK | ROHTAK | HARYANA | 124001 | 1 | Accepted-AOC Work Allotted | |
| 2 | 2₹88.9 L+₹5.9 L (7.13%)Rejected-AOC H NO 1100 SECTOR 3 124001 | ROHTAK | HARYANA | 124001 | 2 | Rejected-AOC Unallotted | |
| 3 | Not Admitted-Technical NA | NA | NA | 121004 | - | Not Admitted-Technical Not Complied with technical specification | |
| 4 | Not Admitted-Technical | - | Not Admitted-Technical Not Complied with technical specification |
Tender Value
₹92.4 L
EMD Value
₹1.8 L
Closing Date
14 Nov 2023, 12:00 pmClosed
SANJEEV KUMAR
EE PHE Division No.2 Jind
Julana Town Estimate for disposal of treated effluent of existing 4 MLD STP to Gatauli Shamlo Drain Julana Town District Jind.
2023_HRY_326625_1
20239D918158 DA62 4AFD B3A7 450D6C3AB255569PUH
Open Tender
Civil Works
Works
365 days
Julana
4 documents required · 4 mandatory
₹5,000
₹1.8 L
Yes
22 Jan 2024
6 Nov 2023
14 Nov 2023
6 Nov 2023
14 Nov 2023
6 Nov 2023
Amount
Supplying, erection, testing and commissioning of submersible pumping sets as per BIS SPECIFICATION No. 8034-1989 (as amended upto date for pumps) and IS 9283- 1979 (as amended upto date for motor) the pump motor sets should be capable of pumping clear fresh cold water having characteristics as specified in Clause-4 of Is 8034 1989 and Clause 4.1 of IS 9283-1979 7000 LPM 45 Mtr. Head 125 BHP
Supplying, erection, testing and commissioning of submersible pumping sets as per BIS SPECIFICATION No. 8034-1989 (as amended upto date for pumps) and IS 9283- 1979 (as amended upto date for motor) the pump motor sets should be capable of pumping clear fresh cold water having characteristics as specified in Clause-4 of Is 8034 1989 and Clause 4.1 of IS 9283-1979 2700 LPM 45 Mtr. Head 50 BHP
Supplying, erection, testing and commissioning of submersible pumping sets as per BIS SPECIFICATION No. 8034-1989 (as amended upto date for pumps) and IS 9283- 1979 (as amended upto date for motor) the pump motor sets should be capable of pumping clear fresh cold water having characteristics as specified in Clause-4 of Is 8034 1989 and Clause 4.1 of IS 9283-1979 1400LPM 45 Mtr. Head 25BHP
Supply, erection, testing and commissioning Wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted of approximate size 1200x900 mm and 400 mm deep having following items :- Main switch 400 Amp. 1 No. (LandT, Siemens, ABB). CT 250/5 Nos. ( AD/ KAPPA/ L and T). Digital Multi Function Meter 1 No. SPP 1 No. of approved make. Motor Starter, Star Delta (L and T Siemmens, ABB) Capacitor KVAR as per site requirement. Indicating Lamp- One set and all other item as per site requirement and suitable capacity for below pumping set 7000 LPM 45 Mtr. Head 125 BHP
Provision for Sluice gate valve complete in all respect as per schedule V and to the besr satisfication of Engineer - in - charge ( make IVC, kirsloskar, at 4 MLD STP 600 x 900 mm.
Bidder Name
Amount
Sudhir Singh Contractor(GSTN-06BBNPS3903D1ZP)
Kulbir Singh Contractor(GSTN-06ATZPS6352H1ZW)
Kulbir Singh Contractor
Kulbir Singh Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .