Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹5.8 L
EMD Value
₹11,619
Closing Date
22 May 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (E) BSNL ED Warangal
EXECUTIVE ENGINEER (E), BSNL Electrical Division, 2nd floor, E-10B Exchange building Hanmakonda, Warangal-506012
Providing repairs of EA sets (for Super critical Critical Stations) at Warangal OA and Karimnagar OA under Warangal BA.SH DG Repairs at Jagityal, Sirsilla ans Metpally Area
2023_BSNL_154230_1
11/EE/BSNLED/WGL/2023-24 dated. 15/05/2023
Open Tender
Electrical Works
Item Rate
60 days
Jagityala
Please refer Tender documents.
16 documents required · 16 mandatory
₹590
Accounts officer (cash),O/O GMTD, BSNL ,WARANGAL
₹11,619
27 May 2023
16 May 2023
23 May 2023
16 May 2023
22 May 2023
16 May 2023
Amount
General Servicing of following capacity EA sets including draining out the existing oil, filling new lubricating oil, replacing the filter kits, adjusting the belt tensions, cleaning the EA set and testing on exchange load as required a)10/15/12.5
Replacement of the following components(when found faulty)i/c removing the existing one and testing after replacement as required. A)Normal duty fuel flexible pipe of length approx.30/36 Inches
Hour Meter electonic type.
V-Belts
Hoses for Radiator
Carbon Brushes i)up to 10/15/20/40
ii)up tp 63 KVA
Rectifier diodes
Coolant
Diesel Over Flow Pipe
Door Hinges
Air Filter Elements (Both Inner and Outer including Sealing ring) i)Upto 63 KVA
Water temperature gauge (mechanical)
Turbo Oil drain Hose
Exhaust Fan
WaterPump assly (up to 62,5 KVA)
Set of Hoses (Water Line)
Oil Filling Cap Assembly
TYRE Type COUPLING For HA694MTC ENGINE
Replacing of Automatic Voltage Regulator (AVR) suitable upto 63 KVA Alternator and necessary wiring connections i/c testing and commissioning as required.)
Replacing/ supplying and fixing of the Self starting motor 12 Volts 2.2 KW suitable for Kirloskar/Mahindra/Escort/Eicher Engines as per their suitable model (Make: Autolek/ Mico/ TVS Lucas)
Battery Copper cable for connecting Battery and self starting Motor ,one end Lug soldering other end Terminal soldering 1mtr long
Control wiring with necessary switch gears/ Ignition switch assly/ Toggleswitch/Push botton /Repairing of control panel to work in Manual mode operation etc as required.
Repairing of Woodward Governor , by removing governor from engine , repairing at workshop by replacing necessory components refixng to the engine testing etc as required,
S/F of 63 amps 4 pole MCB type change over switch including inter connections making good the same etc as required L&T/C&S etc make
Providing 63/40 AMPS Rotory Type Change Over switch
Supplying and fixing of 12 volts 10 Amps SMPS Based Battery chargers
Removing of faulty fuel Injection Pump from Engine, by removing all fuel connections , all bolts and nuts. Shifting of fuel injection pump to he nearest authorised Mico/Bosch Workshop for calibration. Calibration of Fuel injection pump by replacement of necessory components such as Delivery valves, elements, rollers springs,bearings packing kit , 'o'ring kit etc as required . Calibration of fuel injection Pump on test bench by very skilled manpower taking the readings (Discharge quantity and pressure) on testing machine etc as required and vice-versa.
Repairing of jamed fuel injection pump at site by the very skilled man power , cleaning the pump checking the functioning of the governor , testing of the dg etc as required
Repairing of self starter of EA set upto 63 KVA i/c transportation, reinstallation, testing and commissioning as required
Servicing of Radiator of EA set upto 63 KVA Cleaning arresting the lekages, i/c brazing the cracks, Providing as required
Providing and fixing Terminal Plate 63 amps 4 pole
De-coupling of alternator from ebngine by removing vcoupling bolts leg bolts out going cables, both earthings etc and bring the alternator from ea room /Canopy to out side and loading the alternator in to the vehicle after rewinding the alternator , refixing the same in the above manner etc complete as required.
Transportation,unloading of the alternator at the nearest workshop after repair return back to the site, loading at workshop and unloading at the site etc as required.
Providing rewinding of the burnt alternator by removing of burnt stator core with heat treatment process or by hydraulic press at workshop and removing of burnt stator winding cleaning of the core with petrol and providing new insulated paer rewindiong the core with H class insulated copper wire of similar gauge of copper along with similar class of insulation , applying warnishing drying the core by keeping oven by maintenance required temperature, refixing the core in aluminium shield by heat treatment proces or by Hydraulic press refixing the rotor in stator etc and load test on exchange load after installation at site etc complete as required(After deduction of salvage value of old copper) a) 15KVA
Supplying and fixing of RR assembly to the existing rotor including testing making good etc as required.
Supplying and fixing of DE&NDE Bearings
V S ELECTRICAL WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .