Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹2.3 L
EMD Value
₹4,562
Closing Date
3 Dec 2026, 4:30 pm6d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
The Director
CSIR CLRI, Adyar, Chennai
Transformer Oil filtration and servicing of switch gear systems in Electrical Substation at CSIR-CLRI, Adyar, Chennai 600020
2026_CSIR_296011_1
CLRI/26(01)/2026-27/Wks
Limited
Electrical Works
Item Rate
30 days
CSIR-CLRI, Adyar
Please refer tender document
11 documents required · 11 mandatory
₹0
₹4,562
3 Dec 2026
5 Nov 2026
4 Dec 2026
5 Nov 2026
3 Dec 2026
5 Nov 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrical Items | |||||
| 1.01 | Transformer oil Filtration 1000kVA: Filtration of transformer oil through stream line filter unit to improve the Di-electric strength to the optimum value for 1000kVA transformer and testing & providing the test reports for Di-electric strength and acidity of transformer oil, including the transport charges for transformer oil filter unit with oil testing equipments to site & retun back. | 1 | L.S | 100 | ₹100 |
| 1.02 | Transformer oil Filtration 1600kVA: Filtration of transformer oil through stream line filter unit to improve the Di-electric strength to the optimum value for 1600kVA transformer and testing & providing the test reports for Di-electric strength and acidity of transformer oil, including the transport charges for transformer oil filter unit with oil testing equipments to site & retun back. | 1 | L.S | 100 | ₹100 |
| 1.03 | Silica Gel Breather: Supply, installation, testing & commisioning of Dehydrating Silica gel (approximately 1kg) breather suitable capacity to 11kVA/430V Distribution Transformer / OLTC of the transformer of different make having rating upto 1600kVA. | 2 | Each | 10 | ₹20 |
| 1.04 | Insulation Testing: Testing of 1000kVA & 1600kVA Transformer insulation resistance value checking including primary HT cable & secondary bus duct disconnection and refixing as per original conditions. | 2 | L.S | 10 | ₹20 |
| 1.05 | Supply of Tranformer oil: Supply & filling of Trasnformer oil as per IS:335/1993 for exisitng 1000kVA & 1600kVA Transformers (Actual quantity will be billed based on the site requirement) | 300 | Litre | 10 | ₹3,000 |
| 1.06 | Service of OLTC: Filtration of transformer oil in OLTC (1600kVA Transformer) using stream line filter unit including removing & refilling and checking the condition of moving part spares, internal cleaning, gear alignment checking & T/F oil filling based on requirement (Spares & T/F oil price excluded) as required. | 1 | L.S | 10 | ₹10 |
| 1.07 | Overhauling and Maintenance of HT OCB: Removing of the existing HT OCB 400A, operation & testing of relays, checking all the parts including the primary & secondary contacts, Cleaning the dust, mechanism checking, lubrication and refixing the same. Measure the insulation resistance values for all poles with open & closed condition including the testing & issuing of test certificates for following: 1. Over current and earth fault relay 2. Auxiliary relay and Instatenous test 3.Master trip relay 4. Under voltage / over voltage relay (Make: Crompton or equivalent) | 3 | L.S | 10 | ₹30 |
| 1.08 | Overhauling and Maintenance of LT ACB: Removing of the existing LT ACB 3200A, operation & testing of relays, checking all the parts including the primary & secondary contacts, Cleaning the dust, mechanism checking, lubrication and refixing the same. Measure the insulation resistance values for all poles with open & closed condition including the testing & issuing of test certificates for following: 1. Over current and earth fault relay 2. Auxiliary relay and Instatenous test 3.Master trip relay 4. Under voltage / over voltage relay (Make: L&T or equivalent) | 1 | L.S | 10 | ₹10 |
| 1.09 | Overhauling and Maintenance of LT ACB: Removing of the existing LT ACB 2000A, operation & testing of relays, checking all the parts including the primary & secondary contacts, Cleaning the dust, mechanism checking, lubrication and refixing the same. Measure the insulation resistance values for all poles with open & closed condition including the testing & issuing of test certificates for following: 1. Over current and earth fault relay 2. Auxiliary relay and Instatenous test 3.Master trip relay 4. Under voltage / over voltage relay (Make: English Electric or equivalent) | 1 | L.S | 10 | ₹10 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
BOQ_346065.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .