Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹33.0 L+₹18,543.50 (0.57%)Rejected-Finance 11 1 7 P D KYDGANJ PRAYAGRAJ U P PIN 211003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹33.9 L+₹1.1 L (3.47%)Rejected-Finance 0 CIVIL LINES TETARI BAZAR TETARI BAZAR NAUGARH SIDDHARTHNAGAR UTTAR PRADESH 272207 | SIDDHARTH NAGAR | UTTAR PRADESH | 272207 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹41.5 L+₹8.7 L (26.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
Tender Value
₹47.4 L
EMD Value
₹94,880
Closing Date
6 Feb 2023, 6:00 pmClosed
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR
SPL REP/REPLACEMENT OF EXTERNAL WATER SUPPLY LT PANELS AND LT POWER SUPPLY DISTRIBUTION SYSTEM AT 4 AFSB VARANASIUNDER GE AF GORAKHPUR
2023_MES_573949_1
8973/E8
Open Tender
Electrical and Maintenance Works
Item Rate
GE(AF) GORAKHPUR
Class D Cat A ii OR b i
8 documents required · 8 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹94,880
Yes
31 Mar 2023
9 Jan 2023
8 Feb 2023
9 Jan 2023
6 Feb 2023
23 Jan 2023
9 Jan 2023 - 17 Jan 2023
Amount
Excavation in tranches n.exc. 1.5 m deep and n.exc.1.5 m wide in any type of soil and forming bottom surfaces to required level of slope for laying of pipes or for laying of U/G cable complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers n. exc. 25 cm complete all as specified and directed.
Removal surplus soil at a distance n. exc. 50 m and deposited where directed at a lavel not exc. 1.50 m above the starting pont complete all as specified and directed.
Taking up CI water mains of 80 mm dia including all fittings with spigot and socket ends and lead joints including buring out joints and recovering lead, removal to MES store yard all as specified and directed by Engr-in-Charge.
Taking up CI water mains of 150 mm dia including all fittings with spigot and socket ends and lead joints including buring out joints and recovering lead ,removal to MES store yard all as specified and directed by Engr-in-Charge.
Material & laying , fixing in trenches cast iron pipe with spigot and socket ends centrifugally cast class " LA" in any length 80 mm bore all as specified and directed. ( run lead joint shall be measured and paid for separately.)
Material & laying, fixing in trenches cast iron pipe with spigot and socket ends centrifugally cast class " LA" in any length 150 mm bore all as specified and directed. ( run lead joint shall be measured and paid for separately.)
Supply and fix in replacement sluice valve of 80 mm dia ISI marked with cast iron body bonnet wedge stuffing box galvanized thrust plate band plate wheel of gry cast iron ,operated with heigh tensil brass spindle, wedge body seal ring and wedge facing lead tin brass bolt and nut compressed fiber bolt pressured rating PN-I confirmed to 14846 including material and labour for jointing flange joint with rubber / fiber jointing ring bolt nut and washers etc complete all as specified and directed at site. Make Remco/ Kirlosker/BIR.
All as per item No. 08 above but sluice valve of 150 mm dia complete all as specified and directed at site..
Supply and fix CI reflux ( non return ) valve 150 mm bore as per IS 5312 with GM working parts both ends flanged and suitabely machined and drilled for and including required nut , bolts washer rubber/ fiber packing complete all as specified and directed. Make Remco/ Kirlosker.
S & F CI fittings for spigot, socket pipes such as, bends( any type radius and angle) , tapers any type (straight bends in increasing , decreasing or double socket etc.) Tee pieces ,single branch, 'Y' junctions , double branch, cross ( all sockets or socket and spigot), collars , caps and plugs suitable up to 150 mm bore complete all as specified .
All as per item No.11 above but fixing only complete all as specified and directed at site..
M & L for run lead joints for spigot and socket CI pipe and fittings for the 80 mm bore sizes complete all as specified and directed at site.
All as per item No. 13 above but for size 150 mm bore complete all as specified and directed at site.
M & L for flanged joints with rubber fibre board gasket for cast iron pipes 150 mm bore complete all as specified.
Taking up GI steel water tubing from the tranches by necessary excavation or on wall / laid under floor/ ceilings with complete fittings,any grade, removal to MES store yard all as specified for 50mm bore size.( excavation and earth work shall be measured and paid separately.)
All as per item No. 16 above but for size 40mm bore complete all as specified and directed at site.
All as per item No. 16 above but for size 25 mm bore complete all as specified and directed at site.
All as per item No. 16 above but for size 20 mm bore complete all as specified and directed at site.
All as per item No. 16 above but for size 15 mm bore complete all as specified and directed at site.
Supplying and laying steel water tubing medium grade galvanised with all fittings like bend, tees socketes union etc. as required laid in trenches/ or on wall / laid under floor/ ceilings complete all as specified of the 50mm bore size complete all as specified and directed at site..
All as per item No. 21 above but for 40mm bore complete all as specified and directed at site.
All as per item No. 21 above but for 25 mm bore complete all as specified and directed at site.
All as per item No. 21 above but for 20 mm bore complete all as specified and directed at site.
All as per item No. 21 above but for 15 mm bore complete all as specified and directed at site.
Supply and fix in replacement gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipes suitable for 50 mm bore dia of pipe complete all as specified and directed at site.
All as per item No. 26 above but for 40mm bore complete all as specified and directed at site.
All as per item No. 26 above but for 25 mm bore complete all as specified and directed at site.
All as per item No. 26 above but for 20 mm bore complete all as specified and directed at site.
M & L straight plain brass ferrules ( or connnecting screws ) screwed both ends and fixed for the 25 mm bore diameter of pipe complete all as specified and directed at site.
All as per item No. 30 above but for 20 mm bore complete all as specified and directed at site.
S & F chromium plated fancy type bib taps,cast copper alloy with crutch or butterfly handel,screwed down screwed for iron pipe or for brass ferrule and fixed for 15 mm bore dia of pipe complete all as specified and directed.
Dismenteling and taking out complete assyembly of submersible pump set of 41 HP capacity of any make from the existing bore including 45 meter column pipe of size 150 mm bore flanged type ( ERW steel pipe) with jointing material i.e. rubbeer packing ,nuts , bolts and washer etc. by using T & P required for the purpose complete in all respect and deposit to store for keeping in safe custody or for repair as directed by Engineer-in-Charge.
Development of existing bore well by means of 250 PSI Air compressor for not less than 08 hrs under dirctiions of Engineer - in - Charge complete all as specified and directed.
Development of tube well by over pumping until clear discharge is met complete all as specified and directed at site.
Supply , installation / lowering and commissioning the submersible pump set with strove lined non return valve directly coupled with and including induction motor of 35 HP capacity for operation on 415 Volts +/- 10% , three phase , 50 Hz & pump having 5 stage complete with necessary accessoried specified by manufacturer , suitable for 1450 LPM discharge of water at 75 meter head including taking up old u/s submersible pump set all as specified and directed. Make-Penguin / KSB or any other make specified in appendix 'B' to particular specifications.
Supply, connecting and testing (in replacement or for extention) of PVC insulated and sheathed water proof cable wih standard copper conductor flat submersible cable 1100 V grade complete all as specified for cross section area of 25 Sqmm 3 core complete all as specified and directed at site.
Supply and lowering / fixing MS coloumn pipe 150mm bore flange type and 7.1 mm thickness ERW steel pipe including jolinting material i.e. rubber packing nuts, / bolts washers etc complete all as specified and directed at site.
Dismenteling water tanks and removeing store 500 ltrs capacity complete all as specified and directed.
Dismenteling water tanks and removeing store 1000 ltrs capacity complete all as specified and directed.
Supply and fix rotational moulded polyethylene water storage tanks of 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed in SSR Part-I.
Supply and fix rotational moulded polyethylene water storage tanks of 1000 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed in SSR Part-I.
Taking down existing U/S wiring of aviation obstruction light complete from aviation obstruction light to MCB DB ( Approx 50 RM ) complete all as specified and directed at site. .
Matrial & Labour for sub main wiring using 4 sqmm two single core PVC insulated sheathed copper conductor and one run of single core copper cable 1.5 sq mm used as earth wire in PVC conduit of size not less than 20 mm complete all as specified and directed at site.
Supply and fix integral LED aviation light comprising of aluminium housing with polycarbonate enclosure including necessary electric connection with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make Bajaj Cat part No. BGAV 302 LED or equivalent in CG/Havells.
S & F for demolition of old unserviceable valve chamber and construction of new valve chamber of size 1m x 1m x 1 mtr with brick work comprising the following items complete all as specified and directed. (a) 150 MM thick PCC foundation (1:2:4) type B2 40 MM graded aggregrate. (b) Brick construction with (1:6) cement mortar and rendering 15 mm thick externally and internally complete fair face of brick works surface in cm (1:4). (c) MS cover of thickness 4 mm double door type welded to angle of size 40 x 40 x 5 mm embedded in cement coping in PCC (1:2:4) tye B-0 wirh anchor fastner including locking arrangment complete with two coat of heighly corresive resistant apoxy point over one coat of red oxide primer.
Supplying,installation,testing,commissioning of LT panel board 3 phase 4 wire system indoor type factory made wall mounting with suitable clamp dust and vermin proof cubical type interlocking arangement ( IP- 55 protection) fabricated with 2 mm thick CRCA sheet with Anti corrosion coating & finally polyester powder coated of finite green fuly compartment with providing with suitable size of aluminum strip all as specified for the following. (a) Incomming :- (i) On load Change Over Switch 200 Amps , 4 pole 01 No. (ii) MCCB 200 AMPS 4 pole 415 Vollts 35 KA -01 No. (iii) Digital type Amp Meter 0-200 Amp with CT's 03 Nos. (iv) Digital type voltmeter 0-500 Volts -01 No. (v) Indicating lamps (RYB) 01 set of 3. (vi) Aluminium bus bar rating 300 Amps 3 phase neutral-01 set. (vii) Chamber for incoming & outgoing cable. (b) Outgoing :- (i) MCCB 125 AMPS 4 pole 415 Vollts 35 KA -01 No. (ii) MCCB 100 AMPS 4 pole 415 Vollts 35 KA -01 No. (iii ) MCB SPN 32 AMPS 10 KA -03 No. (iv) In built automatic star- Delta starter suitable for submersible Pump upto capacity 50 HP complete with all accessories and wiring complete. Make Havells/ L & T.
Dismantling and taking out unserviceable / defective APFC panel / LT panel / AMF panel by disconnecting all electrical connections complete all as specified and directed
Supplying,installation,testing,commissioning of LT panel board 3 phase 4 wire system indoor type factory made wall mounting with suitable clamp dust and vermin proof cubical type interlocking arangement ( IP- 55 protection) fabricated with 2 mm thick CRCA sheet with Anti corrosion coating & finally polyester powder coated of finite green fuly compartment with providing with suitable size of aluminum strip all as specified for the following. (a) Incomming :- (i) Incoming ACB with Microprocessor Release IPR E of 800 Amps, 4 Pole, 415 Volt with repturing capacity of 50 KA - 1 No. (ii) Digital type Amp Meter 0-800 Amp with CT's 03 Nos. (iii) Digital type voltmeter 0-500 Volts -01 No. (iv) Indicating lamps (RYB) 01 set of 3. (v) Copper bus bar rating 1200 Amps 3 phase neutral-01 set. (vi) Chamber for incoming & outgoing cable. (b) Outgoing :- (i) MCCB 400 AMPS 4 pole 415 Vollts 36 KA -02 No. (ii) MCCB 250 AMPS 4 pole 415 Vollts 36 KA -02 No. (iii) MCCB 200 AMPS 4 pole 415 Vollts 36 KA -01 No.
Supplying,installation,testing,commissioning of AMF control panel suitable for 45 KVA kirlosker make DG Set, factory made free standing , floor mounting dust and vermin proof cubical type interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finally powder coate painting having thickness not les than 100 microns of finite grey, fully compartmentalized with providing two Nos suitable size of aluminum strip for body earthing and including suitable PCC foundation all as specified for the following :- (i) MCCB 100 A ,4P, 36 KA, 415 Volt AC,50 Hz. - 02 Nos. (ii) Power Contactor, 100 A ,4P,operating coil voltage 240 V AC. - 02 Nos. (iii) VAF Meter with CTs 200/5A 15 VA- 01 Set. (iv) LED indicator lamp ( R,Y,B & G ) -01 Set. (v) AMF controller - 01 No. (vi) Battery charging system complete with DC volt meter , DC amp meter indicating lamp,switches,fuses,charging lead - 01 set. (v) 6A, 2P, 2 Way local - remote / auto - manual switch with center off. (vi) DG start/ stop push button and emergency stoop push button. (vii) All other necessary accessories recommended and required by manufacturer such as cranking relay pla relay auxiliary contactor indicator lamp and MCB etc and including complete control wiring between AMF panel and DG set.
Supplying,installation,testing,commissioning of AMF control panel suitable for 75 KVA kirlosker make DG Set, factory made free standing , floor mounting dust and vermin proof cubical type interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finally powder coate painting having thickness not les than 100 microns of finite grey, fully compartmentalized with providing two Nos suitable size of aluminum strip for body earthing and including suitable PCC foundation all as specified for the following :- (i) MCCB 160 A ,4P, 36 KA, 415 Volt AC,50 Hz. - 02 Nos. (ii) Power Contactor, 160 A ,4P,operating coil voltage 240 V AC. - 02 Nos. (iii) VAF Meter with CTs 200/5A 15 VA- 01 Set. (iv) LED indicator lamp ( R,Y,B & G ) -01 Set. (v) AMF controller - 01 No. (vi) Battery charging system complete with DC volt meter , DC amp meter indicating lamp,switches,fuses,charging lead - 01 set. (vii) 6A, 2P, 2 Way local - remote / auto - manual switch with center off. (viii) DG start/ stop push button and emergency stoop push button. (ix) All other necessary accessories recommended and required by manufacturer such as cranking relay pla relay auxiliary contactor indicator lamp and MCB etc and including complete control wiring between AMF panel and DG set. (i) MCCB 200 A ,4P, 36 KA, 415 Volt AC,50 Hz. - 02 Nos.
Supplying,installation,testing,commissioning of AMF control panel suitable for 100 KVA Crompton Greaves make DG Set, factory made free standing , floor mounting dust and vermin proof cubical type interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finally powder coate painting having thickness not les than 100 microns of finite grey, fully compartmentalized with providing two Nos suitable size of aluminum strip for body earthing and including suitable PCC foundation all as specified for the following :- (i) MCCB 200 A ,4P, 36 KA, 415 Volt AC,50 Hz. - 02 Nos (ii) Power Contactor, 200 A ,4P,operating coil voltage 240 V AC. - 02 Nos. (iii) VAF Meter with CTs 200/5A 15 VA- 01 Set. (iv) LED indicator lamp ( R,Y,B & G ) -01 Set. (v) AMF controller - 01 No. (vi) Battery charging system complete with DC volt meter , DC amp meter indicating lamp,switches,fuses,charging lead - 01 set. (vii) 6A, 2P, 2 Way local - remote / auto - manual switch with center off. (viii) DG start/ stop push button and emergency stoop push button. (ix) All other necessary accessories recommended and required by manufacturer such as cranking relay pla relay auxiliary contactor indicator lamp and MCB etc and including complete control wiring between AMF panel and DG set.
Taking down the existing defective LT UG cable from LT panel / pipes / existing duct for fault finding / replacement, all as specified and directed of any size between 150 Sq mm 3.5 core complete all as specified and directed at site.
Dismentling of ACSR conductors complete all as specified and directed at site.
Dismentling of earth wire complete all as specified and directed at site.
Dismentling of cross arms of MS channel or angle sections etc. complete all as specified and directed at site.
Dismentling of insulator any type any size complete all as specified and directed at site.
Supply and laying ,jointing and testing XLPE insulated extruded PVC outer sheath and inner sheath galvanized steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade conforming to IS 7089 (Pt I of 1988) laid in tranches/ pipe/duct/pole complete all as specified and directed size 240 Sqmm 3.5 core.
All as per item No 59 above but size 150 Sqmm 3.5 core complete all as specified and directed at site..
All as per item No 59 above but size 120 sqmm 3.5 core complete all as specified and directed at site..
All as per item No 59 above but size 50 sq mm 3.5 core complete all as specified and directed at site.
All as per item No 59 above but size 35 sq mm 3.5 core complete all as specified and directed at site.
All as per item No 59 above but size 10 Sqmm 4 core complete all as specified and directed at site.
Supply laying fixing or passing through pipe 1100 Voltage grade heavy duty cable with PVC insulated and sheathed aluminium conductor comfirming to relevent IS size 6 sqmm 2 core unarmoured and connecting to system complete all as specified and directed.
Supply & laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm thick over the cable complete all as specified and ditected.
Supply & laying brick for protection of cable sub class 'B' laid dry flat across the cable with width equal to the length of whole bricks complete all as specified and ditected.
Material & Labour for boring, holes for inserting of 50/80 mm bore GI pope under the road/hard standing or any other location not less than 1200 mm deep complete all as specified and ditected.
M & L GI pipe 20 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed.
M & L GI pipe 40 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed.
M & L GI pipe 50 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed.
M & L GI pipe 80 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed.
Supply and fix in replacement FRP , hot press moulded SMC pole box 295X255X120 mm comprising of 100 Ams aluminium bus bar 4 strips ( IP 55 protection ) with one MCB SP 6 Ams to be fixed inside the box and box will be clamped bottom of the pole with FI clamps (duly painted ) nut bolt washers of required size.Make - SINTEX ,Model GSJB-2520 or any other sample approved by GE.
Supply, install, connect & testing cubical outdoor type factory made double door , powder coated LT bus bar feeder pillar box having alluminium bus bar suitable for 200 amps 3 phase and neutral arrangement of size 500mm x 500mm x 200mm with MCCB 4 pole 100 A as incoming including provision of LED Indicating lamps (RYB) 01 set of 3. complete weather proof and vermin proof conforming to IP-54 made out of 3.15 mm thick CRCA sheet including provisions for ventilation and cable termination alley & two Nos suitable size of aluminum strip for body earthing all as per IS. It should be mounted on 40 x40 x 6mm angle frame with a clearance of at least 0.45 mtrs above GL and 0.30 mtrs below ground including required PCC for foundation complete all as specified and directed.
Supplying,installation,testing,commissioning of outdoor type LT panel board 3 phase 4 wire system ,415 Volts ,50 Hz factory made free standing , floor mounting dust and vermin proof cubical type interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finally powder coate painting having thickness not less than 100 micronsof finite grey, fully compartmentalized with providing two Nos suitable size of aluminum strip for body earthing and including suitable PCC foundation all as specified for the following :- (a) Incoming :- (i) MCCB 400 AMPS 4 pole 415 Vollts 36 KA -01 No. (ii) Digital type amp meter 0-400 Amp with CT's 03 Nos. (iii) Digital type voltmeter 0-500 Volts -01 No. (iv) Indicating lamps (RYB) 01 set of 3. (v) Aluminium bus bar rating 600 Amps 3 phase neutral-01 set. (vi) Chamber for incoming & outgoing cable. (b) Outgoing :- (i) MCCB 350 AMPS 36 KA 415 Volts 4 pole -01 No. (ii) MCCB 100 AMPS 25 KA 415 Volts 4 pole -03 No.
Supplying,installation,testing,commissioning of outdoor type LT panel board 3 phase 4 wire system ,415 Volts ,50 Hz factory made free standing , floor mounting dust and vermin proof cubical type interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finally powder coate painting having thickness not less than 100 micronsof finite grey, fully compartmentalized with providing two Nos suitable size of aluminum strip for body earthing and including suitable PCC foundation all as specified for the following :- (a) Incoming :- (i) MCCB 350 AMPS 4 pole 415 Vollts 36 KA -01 No. (ii) Digital type amp meter 0-400 Amp with CT's 03 Nos (iii) Digital type voltmeter 0-500 Volts -01 No. (iv) Indicating lamps (RYB) 01 set of 3. (v) Aluminium bus bar rating 600 Amps 3 phase neutral-01 set . (vi) Chamber for incoming & outgoing cable. (b) Outgoing :- (i) MCCB 250 AMPS 36 KA 415 Volts 4 pole -01 No. (ii) MCCB 200 AMPS 36 KA 415 Volts 4 pole -01 No. (iii) MCCB 100 AMPS 25 KA 415 Volts 4 pole -01 No.
Supplying,installation,testing,commissioning of outdoor type LT panel board 3 phase 4 wire system ,415 Volts ,50 Hz factory made free standing , floor mounting dust and vermin proof cubical type interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finally powder coate painting having thickness not less than 100 micronsof finite grey, fully compartmentalized with providing two Nos suitable size of aluminum strip for body earthing and including suitable PCC foundation all as specified for the following :- (a) Incomming :- (ii) MCCB 250 AMPS 4 pole 415 Vollts 36 KA -01 No. (iii) Digital type amp meter 0-300 Amp with CT's 03 Nos. (iv) Digital type voltmeter 0-500 Volts -01 No. (v) Indicating lamps (RYB) 01 set of 3. (vi) Aluminium bus bar rating 400 Amps 3 phase neutral-01 set. (vii) Chamber for incoming & outgoing cable. (b) Outgoing :- (i) MCCB 200 AMPS 36 KA 415 Volts 4 pole -1 No. (ii) MCCB 160 AMPS 36 KA 415 Volts 4 pole -2 No. (iii) MCCB 125 AMPS 25 KA 415 Volts 4 pole -1 No.
Supplying,installation,testing,commissioning of outdoor type LT panel board 3 phase 4 wire system ,415 Volts ,50 Hz factory made free standing , floor mounting dust and vermin proof cubical type interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finally powder coate painting having thickness not less than 100 micronsof finite grey, fully compartmentalized with providing two Nos suitable size of aluminum strip for body earthing and including suitable PCC foundation all as specified for the following :- (a) Incomming :- (i) MCCB 200 AMPS 4 pole 415 Vollts 36 KA -01 No. (ii) Digital type amp meter 0-200 Amp with CT's 03 Nos. (iii) Digital type voltmeter 0-500 Volts -01 No. (iv) Indicating lamps (RYB) 01 set of 3. (v) Aluminium bus bar rating 300 Amps 3 phase neutral-01 set. (vi) Chamber for incoming & outgoing cable. (b) Outgoing :- (i) MCCB 100 AMPS 25 KA 415 Volts 4 pole -2 No. (ii) MCCB 63 AMPS 16 KA 415 Volts 4 pole -02 No.
Supplying,installation,testing,commissioning of outdoor type LT panel board 3 phase 4 wire system ,415 Volts ,50 Hz factory made free standing , floor mounting dust and vermin proof cubical type interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finally powder coate painting having thickness not less than 100 micronsof finite grey, fully compartmentalized with providing two Nos suitable size of aluminum strip for body earthing and including suitable PCC foundation all as specified for the following :- (a) Incomming :- (i) MCCB 160 AMPS 4 pole 415 Vollts 36 KA -01 No. (ii) Digital type amp meter 0-200 Amp with CT's 03 Nos. (iii) Digital type voltmeter 0-500 Volts -01 No. (iv) Indicating lamps (RYB) 01 set of 3. (v) Aluminium bus bar rating 300 Amps 3 phase neutral-01 set. (vi) Chamber for incoming & outgoing cable. (b) Outgoing :- (i) MCCB 100 AMPS 25 KA 415 Volts 4 pole -2 No. (ii) MCCB 63 AMPS 16 KA 415 Volts 4 pole -02 No.
Supplying,installation,testing,commissioning of outdoor type LT panel board 3 phase 4 wire system ,415 Volts ,50 Hz factory made free standing , floor mounting dust and vermin proof cubical type interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finally powder coate painting having thickness not less than 100 micronsof finite grey, fully compartmentalized with providing two Nos suitable size of aluminum strip for body earthing and including suitable PCC foundation all as specified for the following :- (a) Incomming :- (i) MCCB 125 AMPS 4 pole 415 Vollts 36 KA -01 No. (ii) Digital type amp meter 0-200 Amp with CT's 03 Nos. (iii) Digital type voltmeter 0-500 Volts -01 No. (iv) Indicating lamps (RYB) 01 set of 3. (v) Aluminium bus bar rating 200 Amps 3 phase neutral-01 set . (vi) Chamber for incoming & outgoing cable. (b) Outgoing :- (i) MCCB 100 AMPS 25 KA 415 Volts 4 pole -1 No. (ii) MCCB 63 AMPS 16 KA 415 Volts 4 pole -02 No.
Dimolation and dimantling PCC ( unreinforced) of any description and in any position complete all as specified and directed at site.
PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping , including necessary form work. complete all as specified and directed at site.
Preparation of old painted steel surface and painting of steel tubular pole upto 09 RM long applying two coats of aluminium paint on complete poles including cross arms and writing of numbers on pole with black paint in 40 mm font size of letters including surface dressing all around the poles approximetely 01 Sq Mtr area complete all as specified and directed at site.
M&L earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 4.00 M deep below GL with top edge of plate not less than 3.00 m below GL) connected with GI earth strip of 32X6 mm as earthing leads by means of bolts, nuts, check nuts and washers beside brazing at all joints as shown on drawings and including excavation, earth work. GI pipe light grade 40 mm bore for protection of GI earth strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed.
M&L earthing complete with galvanised steel earth plate 600X600X6.3 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 m below GL) connected with GI earth strip of 32X6 mm as earthing leads by means of bolts, nuts, check nuts and washers beside Welding / brazing at all joints as shown on drawings and including excavation, earth work. GI pipe light grade 40 mm bore for protection of GI earth strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed.
M/S Akhilesh Enterprises
PANDEY TRADERS
SHARP ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .