Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.5 LAccepted-AOC 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC Lowest quoted | |
| 2 | L2₹51.7 L+₹2.1 L (4.26%)Rejected-AOC | L2 | Rejected-AOC quoted higher than L1 bidder | |
| 3 | L3₹52.0 L+₹2.4 L (4.92%)Rejected-AOC CANADA BUILDING 224 DR D N ROAD FORT MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L3 | Rejected-AOC highest quoted |
Tender Value
₹48.0 L
EMD Value
₹95,970
Closing Date
9 Oct 2020, 3:00 pmClosed
Sr APD
Dr Babasaheb Ambedkar International Airport Nagpur
SITC of SAPL Threshold light fittings and Installation of PAPI14 lightings at Dr Babasaheb Ambedkar International Airport Nagpur
2020_MADC_612122_1
MIL/NGP/Engg E/2020-21/NIT 10
Open Tender
Electrical Works
Item Rate
90 days
Dr Babasaheb Ambedkar International Airport Nagpur
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,248
MIHAN India Ltd
₹95,970
29 Oct 2020
24 Sept 2020
12 Oct 2020
24 Sept 2020
9 Oct 2020
24 Sept 2020
Amount
Supply of 300 watts, 6.6A/6.6A, 5 KV 50 Hz, PCP encapsulated isolating transformer suitable forindividual series lamps airport lighting circuits. The transformer shall be designed to be water proofand suitable for direct burial in the earth or installation in a base complete as per specifications attached.
Supply of following uni-directional INSET TYPE HIRL Approch LIGHT FITTING with shallow base, matching body made of die cast aluminium, 3 x 105W 6.6Amps pre-focused Halogen Lamp, connected heat resistant accessories, prism assembly, optical assembly, 'O' ring seal, pressue relief plug, hardware, clear lenses etc. complete as required including 1 set of spare 'O' ring, gaskets and 1 Set of spare lamps as per the particular specifications enclosed.
Supply of elevated type High Intensity Uni-directional Threshold light fitting with Green Lens suitable for use with 200W, 6.6A, Halogen Lamp complete with spreader lens clamping mechanism, pre-focus lamp holder, central column assembly, breakable coupling, gaskets, two pin secondary lead plugs, base plate with six numbers M-10 stainless steel bots, spring and plain washers, including 200W Halogen Lamp with suitable Green spreader lens specified accessories confirming to ICAO requirements and as per the enclosed particular specifications etc. complete as required.
Supply of 1 x 6 sq.mm, 5 KV grade copper conductor XLPE insulated, polyethylene sheathed, singlecore, copper tape screened Airfield Ground Lighting series cable as per specifications as required.
Supply of 1 x 16 sq.mm, 5 KV grade copper conductor XLPE insulated, polyethylene sheathed, singlecore, copper tape screened Airfield Ground Lighting series cable as per specifications as required.
Supply of C.I. Isolating Transformer housing box along with top lead, water tight, round type, metal container of size 330mm dia and 200 mm height made of 10 mm thick cast iron molding all round, except the top surface, which is 15 mm thick cast iron suitable to receive a light fitting base plate on the top and underground housing associated with transformer power cable and having clear holes, each on three side surface(two diametrically opposite (for AFL cable entry) and one in between), centre 3" above bottom surface suitable to receive 1 no of 50mm. dia "B" class GI pipe & check nuts as required. The box should have two earth bolts of M 10 X 30 mm. welded inside near the cable entry hole on one side, 4" away from the hole centre and having a drain hole at the bottom suitably tapped to receive 15 mm. dia. "B" class GI pipe and having clear opening of 220 mm. at the top surface and 6 nos M10 tapped hole at the hole center 260 mm. dia. to receive fitting base plate and bolts as required as per the drawing. Single Hole CI Housing Box.
Supply of C.I. Isolating Transformer housing box along with top lead, water tight, round type, metal container of size 330mm dia and 450 mm height made of 10 mm thick cast iron molding all round, except the top surface, which is 15 mm thick cast iron suitable to receive a light fitting base plate on the top and underground housing associated with transformer power cable and having clear holes, each on three side surface(two diametrically opposite (for AFL cable entry) and one in between), centre 3" above bottom surface suitable to receive 1 no of 50mm. dia "B" class GI pipe & check nuts as required. The box should have two earth bolts of M 10 X 30 mm. welded inside near the cable entry hole on one side, 4" away from the hole centre and having a drain hole at the bottom suitably tapped to receive 15 mm. dia. "B" class GI pipe and having clear opening of 220 mm. at the top surface and 6 nos M10 tapped hole at the hole center 260 mm. dia. to receive fitting base plate and bolts as required as per the drawing. Single Hole CI Housing Box
Supply of 2 x 4 sqmm, 600 V grade EPR insulated, PCP sheathed, two core copper conductor secondary cable as required
Supply of 600 V grade plug and receptacle of type II, class 'B' connector and suitable for field attachment with 2 x 4 sq.mm. EPR insulated, PCP sheathed, two core copper conductor secondary cable as required
Supply of 6 Sqmm plug & receptacle of type I, class B connector & suitable field attachment with 5 KV grade XLPE insulated PE sheathed single core screened copper conductor cable as required.
Installation, testing and commissioning of PAPI System (04 units) along with all its accessories, bases for checking stick including finalization of location, taking level & setting right angles (minimum 03 times) by Total Station / Theodolite, excavation, RCC foundation (1:2:4) upto required level, plastering, refilling, providing foundation bolts and nuts, fitting, fixing, cleaning, marking, earthing, connecting, providing pipe for secondary leads, painting and ground calibration of the system etc. complete as required
Installation, testing and commissioning of inset fittings with core drilling, aligning & setting including providing sealing material & installation of shallow base, isolating transformers, crimping / joining of plug & receptacles and moulding the leads, connection of secondary leads alongwith other accessoriesrequired for commissioning i/c supply of all consuamables materials etc. as required.
Installation, testing and commissioning and numbering of elevated type HIRL /MIRL fitting/Taxiway on the existing collar including installation of lens, filters, lamps and other accessories, alignment, levelling, making transformer connection, earth connection etc. complete as required.
Making field connections by crimping 16/6 Sq.mm plug and receptacle with existing16/6 sq.mm single core PVC copper conductor PVC insulated, PVC sheathed cable including filling the gap with water sealing compound, applying HT insulation tape, over which PVC tape etc. as required.
Installation of Transformer Housing Box with a base concrete of 1:3:6 of size 630x630x100mm thick all round concrete of 1:2:4, 150mm thick, the top sloppedd with 1:2:4 cement concrete including providing and fixing 250mm long 15mm dia. "B" class GI pipe with check nut for drainage of water including excavation of side shoulder and refilling etc. complete as required
Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (50 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63mm dia(OD-63 mm & ID-51mm nominal
Cutting kerf of suitable size i/c chipping, hammering, cleaning & drying etc. & refilling the kerf with sealant material including primer etc. as reqd. in bitumin/PQC area & laying following numbers of secondary leads:-
Earthing with GI earth pipe 4.5 m long and 40mm dia, accessories and providing masonary enclosurewith cover plate on the top having locking arrangement and watering pipe, complete with charcoal and salt etc. as required
Laying of one no. XLPE insulated & Polyethelene sheathed AFL screened cable of 5 KV grade size /LTcable/secondary lead upto 25 sqmm in the existing RCC/ METAL/HDPE pipe as reqd.
Providing and Laying earth connection from earth electrode with 6 SWG dia GI wire in 15mm dia GI pipe from earth electrode as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing complete as required.
Supply of Red Filter 180 degree
Supply of Black Filter 180 degree
Supply of PAPI Filter Red
Supply of Runway Lamp (Halogen) Holder
Supply of C. I. Box Cover Plate 10 mm thick
Supply of HT Tape
Supply of Insulation Tape
Agrawal Traders
AMA private Limited
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .