| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.0 CrAccepted-AOC | ₹46.0 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹47.6 CrRejected-Finance C 709 VARDHAMAN APARTMENT MAYUR VIHAR I DELHI 110091 INDIA | EAST | DELHI | 110091 | ₹47.6 Cr | L2 | Rejected-Finance 2nd Lowest Bidder |
| 3 | L3₹47.6 CrRejected-Finance | ₹47.6 Cr | L3 | Rejected-Finance 3rd Lowest Bidder |
| 4 | L4₹47.7 CrRejected-Finance SITANI BUILDING DINBAZAR JALPAIGURI 735101 | JALPAIGURI | JALPAIGURI | WEST BENGAL | 735101 | ₹47.7 Cr | L4 | Rejected-Finance 4th Lowest Bidder |
| 5 | L5₹47.7 CrRejected-Finance | ₹47.7 Cr | L5 | Rejected-Finance 5th Lowest Bidder |
Tender Value
₹48.2 Cr
EMD Value
₹15 L
Closing Date
3 Oct 2020, 6:00 pmClosed
CE (AF) SHILLONG
HQ CE (AF) SHILLONG ZONE, ELEPHANT FALLS CAMP, PO-NONGLYER, SHILLONG-793009
CONSTRUCTION OF 2 MMPUs AND ESH BUILDING AT AF STN HASIMARA
2020_MES_370957_1
88411/HAS
Open Tender
Civil Works
1855 days
GE(P)(AF) HASIMARA
AS PER NIT
7 documents required · 7 mandatory
₹3,000
GE (P) (AF) HASIMARA
₹15 L
Yes
12 Oct 2020
21 Aug 2020
5 Oct 2020
21 Aug 2020
3 Oct 2020
22 Sept 2020
22 Aug 2020 - 21 Sept 2020
Amount
NOTE (Applicable for all parts/items):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
SCHEDULE "A" Part - I (BUILDING / STRUCTURES WORK ) Details of pre priced schedule is given in tender documents
SCHEDULE "A" PART-II (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (OVERHEAD GANTRY INSIDE THE BUILDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (ROAD) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (CULVERT ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (HARD STANDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XII (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XIII (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIV (CCTV, LAN & TELEPHONE CONDUITING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XV (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XVI (FIRE ALARM ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XVII (FENCING & GATE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XVIII (AIR CONDITIONING, REFRIGERATION & COOLING APPLIANCES ) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' 5 ' signifies this fact only.
Design, Supply, Installation, Testing and Commissioning of Chilled water Central Air-conditioning system of capacity not less than 150 TR (2x75 TR working and 1X75 TR standby) including following items and other items as required for satisfactory performance of the plant complete in all respect for MMPU all as specified in respective drawings to achieve the inside design conditions as per ANNEXURE ‘A’ and details as per ANNEXURE 'A-1' enclosed here-in-after.
Design, Supply, Installation, Testing and Commissioning of Chilled water Central Air-conditioning system of capacity not less than 105 TR (2x52.5 TR working and 1X52.5 TR standby) including following items and other items as required for satisfactory performance of the plant complete in all respect for ESH all as specified in respective drawings to achieve the inside design conditions as per ANNEXURE ‘B’ and details as per ANNEXURE 'B-1' enclosed here-in-after. Note 1 (for Item Ser No 18.01 & 18.02) :- (a) Contractor / bidder needs to check the desired inside design conditions carefully and submit the bid only after ascertaining the capacity of the AC plant required to achieve the inside design conditions. (b) Contractor / bidder should submit complete design for the Central AC plant comprising of heat load calculations, working drawings of complete AC plant supported with design/calculations of each component duly vetted by IIT/NIT/OEM within two months of the date of commencement of work through GE for the approval of Accepting Officer before execution of the work. (c) Contractor/bidder will be responsible for performance guarantee of complete AC plant to achieve the inside design conditions round the clock throughout the year with overall COP of the system not less than 3. (d) Design, Supply, Installation, Testing and Commissioning of Chilled water Central Air-conditioning system shall be undertaken through Manufacturers/ Specialist Firms. Note 2 (for Item Ser No 18.01 & 18.02):- Rates quoted by the contractor shall be complete finished work including cost of all labour, material, scaffolding, finishing as required with tools, plants, cartage, lift, taxes, tollage, octroi, royalties etc. All works shall be executed as per drawings and instructions of Site-in-charge and shall include the supply and installation at site of all the equipment, ancillary materials as specified and all such items what-so-ever which may be required to fulfill the intent and purpose as laid down in the drawings. All materials shall be as per ISI specification and with IS certification marked wherever applicable. The material shall be duly approved by Site in-charge before incorporation in the actual work. Note 3 (for Item Ser No 18.01 & 18.02):- Rates quoted by the contractor shall deemed to be included for Manning & Operation of AC Plants (single operator for both the Plants, round the clock in three shifts) during the period of seasonal tests.
Supply and fixing highlights multifunctional large LED display low power consumption high stability and accuracy functions indoor/ outdoor temperature display, indoor humidity display connectwide Clock Htc-2 digital thermo Hygrometer Electronic Temperature Humidity meter Clock Large LED display, white, (1 Pcs) size 10.5*10 Cm, Indoor and outdoor temperature, humidity date, Clock for 12/24 Hours, Daily Alarm 4. Max / Min Function 5. Indoor temperature range : -10-50/ -14 -122, outdoor temperature range : -50-7- / -58-1587. Humidity measurment Range 10-99 % Rh including power supply : 1* 1.5 AAA battery complete all as specified and directed.
Supply and installation Thermozone Air Curtain AIROTEK model AT-318 of Size 915mmx280mmx280mm, Air velocity 15-18 Mtr/Sec, PSC * induction motor 1400 RPM, current rating 1.5 Amps new generation type designed for horizontal mounting sheet metal pre- treatment, nice looking powder coat painting and new assembly techniques are some of the manufacturing steps which coupled with quality control and test facilities ensure a high degree of reliability, reable noiseless operation with high performance , compact rigid structure with heavy gauge sheet metal(CRCA body), well balanced centrifugal impellers with SS blade and self lubricated sealed bearing heavy duty powerful trouble free motor for continuous operation and easy to Installed and service complete all as specified and directed.
Supply and installation of intelligent Air Curtain sensor control system allowing and opening the installed air curtain with three different fan speed for being as possible yet providing the best and most efficient air curtain effect. The air curtain can with the integrated control system also be connected to a BMS system. The control system can be adjusted on the panel included remote control complete all as specified and directed.
Supply, installation and commissioning of Stainless Steel Water Cooler electric driven (single phase), having approx storage capacity of 40 litre and nominal cooling capacity of 40 Litres per hour complete all as specified and directed.
S&F of Voltage Stabilizer, Single Phase, air cooled, input variation between 130 V to 300 V, 6 Amps, output voltage stabilized at 230 V with accuracy of +2.5%. Make- V Guard Model No-VG 150 or equivalent from make list as specified in PS.
AC MONITORING SYSTEM (FOR ESH BUILDING). Supply & installation of flowchart based programmable Remote Terminal Unit along with battery backup for incase of power fail SMS to Engineer-in-Charge. - Input output as per requirement in system - 3 Serial Port - Digital Inputs (Optical isolation) - Digital outputs - Isolated Analog inputs for monitoring of Temperature & humidity - Local Display, membrane key board and data storage - Compatibility with GSM Modem Make : Cimcon / Safetek/Powertek (To be installed at Central Chiller plant but outside the storage building)
Supply & installation of MS Powder coated CRCA 1.6 mm thickness outdoor panel of minimum size 600mm x 600mm x 300mm for indicator and isolation transformer for RTU protection, to protect voltage fluctuation & provide isolation complete all as specified and directed. Primary Side : Input 0-230-380-415-460 AC Secondary side : Input 0-230 AC Make : CIMCON / BCH/Rittal/Safetek/Powertek (To be installed at Central Chiller Plant but outside the storage building)
Supply & installation of wireless modem suitable for GSM/GPRS based communication system, to be mounted in RTU enclosure complete all as specified and directed. Make : Cimcon / Siemens / Motorola (To be installed at panel & MCS)
Supply & installation of Temperature and Humidity Sensor with transmitter for the room and duct Temperature and Humidity measurement complete all as specified and directed. Make : Masibus / Wika / Baumer / Radix
Supply & installation of process indicator of 48mm x 48mm with retransmission output for monitoring of temperature and humidity complete all as specified and directed. Make : Multispan / Radix / Masibus (To be installed at panel)
Supply & fixing of 75mm x 50mm x 2 mm cable tray installation with material, for inside the chiller plant complete all as specified and directed.
Supply & fixing of 4 Core x 1.5 Sqmm PVC coated armoured copper control cable complete all as specified and directed.
Supply & fixing of 3 Core x 1.5 Sqmm PVC coated armoured copper control cable complete all as specified and directed.
Supply & fixing of 10 Core x 1.5 Sqmm PVC coated armoured copper control cable complete all as specified and directed.
Master Control Station :- Supply & installation of intel core i3 processor or equivalent at minimum 2.00 GHz (2 MB L 2 cache), Intel Server Based Motherboard with minimum 800 MHz bus speed, 2 GB DDR 2 SDRAM @ 667 MHz, 160 GB SATA HDD, DVD Writer, 2 x USB 2.0, 2 x Serial Port, Gigabyte LAN 23" TFT Dispaly Monitor with Resolution of 1440 x 900 Pixel and Support 16.2 M Color with required software complete all as directed. Make : HP / DELL / HCL / ACER (To be installed at MCS & Armoury Room)
Supply & installation of License verson software windows-10, MS Office 2016 and anti virus Software complete all as directed. Make : Quick Heal, Mc Afee, NPAV, Microsoft
Supply & installation of UPS-600 VA, 230V, AC complete with minimum battery backup 15 minutes complete all as directed. Make : APC / Microtek /Live Line
Supply & installation of Laser printer with scanner A4 B & W complete all as directed. Make : HP / Canon / Samsung. (To be installed at MCS)
Supply & installation of SCADA Software License version with required tages for Central Monitoring and control through wireless communication for Master Control Station. Make : Cimcon / Safetek / Motorola. (To be installed at MCS & Armoury Room)
Supply & installation of Front End Processor (FEP) ARM 9 PROCESSOR 32 bit micro controller 512 MB mermory 64 MB data memory with real time clock & 16 x 2 line LCD display, 2 USB, 2.0 ports IS standard, 5-300 Hz communication protocol suitable to GSM mode communication for Master Control Station complete all as directed. Make : Cimcon / Safetek / Powertek . (To be installed at MCS & Armoury Room) (Note: One GSM sim card shall be installed in the FEP with rental & SMS charges, Rs 350.00 per month, for the period of two years, from the date of completion of work, shall be provided by the contractor and cost of the same shall deemed to be included in the unit rate.)
Comprehensive maintenance of complete SCADA system after defect liabillity for Maintenance and monitoring after satisfactory completion of PHASE-I (i.e. SITC work of all the equiipments / accessories at site and Master Monitoring Centre as specified). It includes WHOLE SCADA Automation SYSTEM. Note : (i) Comprehensive maintenance includes replacement of unserviceable parts of equipments as required to run the system fully functional without any cost to the department. (ii) The technician shall be professionally qualified engineer and shall have minimum two years experience in this field.
SCHEDULE "A" PART -XIX (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' 5 ' signifies this fact only.
Forming embankments including raising (or lowering) with RBM, spreading in layers n exc. 30cm thick, watering ramming/rolling and finishing to required size, shape, etc n. exc 1.5m high from base complete all as specified and directed.
INTERNAL ELECTRIFICATION. S&F Blanking plate 1 module. Make :- Legrand Cat No.573649 or equivalent model of make as specified in PS.)
S&F 1400mm sweep ceiling fan and connecting up of cable from ceiling rose with PVC insulated sheathed three core copper conductor wire of size 23/0.0076h connector to fan complete all as specified and as directed.
S&F 1200mm sweep ceiling fan and connecting up of cable from ceiling rose with pvc insulated sheathed three core copper conductor wire of size 23/0.0076h connector to fan complete all as specified and as directed.
Supply and Fixing exhaust fan of size 300mm sweep 1400 rpm and connecting up including provision of cable from ceiling rose or connector to fan complete with louvers complete all as specified and directed.
All as per item Ser No 19.06 here-in-before but of size 450mm sweep complete.
S&F Flame proof wall mounting fan 415mm sweep,1440RPM,250V duly enclosed in cast aluminum alloy LM6 construction complete with fan regulator and fixing arrangement complete all as specified and directed.
S&F LED light fitting flame proof type FLP-WP of 2x20W CMRI certified flame proof light fitting including integral reflector made of aluminium alloy LM6 with heat resistant tubular glass cover held in two aluminium cups, with bipin holders, connector block, etc. and all accessories prewired and including 2 Nos 20 Watt LED tube light of suitable size, connecting up with three core PVC insulated sheathed copper conductor cable of size not less than 0.5 sqmm complete all as specified and directed. (Make: Crompton Cat No.EXTN2LT8-16/20 or equivalent model from make list as specified in PS.)
S&F LED light fitting, 36W, 230V indoor decorative hanging type aluminium extruded dimension 4ft LED Battens-integrated type, with bipin holders, connector block, etc. complete with all accessories pre-wired and including connecting up with three core pvc insulated sheathed copper conductor cable of size 23/0.0076 all as specified and as directed. Make:Crompton Cat No.LCLP54-36-CDL or equivalent model from make list as specified in PS.
S&F LED security light fitting, 20W , 230V Powder coated pressure die cast aluminium compact high power with heat resistant toughned glasswith suitable outer diameter GI bracket,clamp nut bolt etc. complete with all accessories pre-wired and including connecting up with three core pvc insulated sheathed copper conductor cable of size 23/0.0076 all as specified and as directed. (Make:Crompton Cat No.LST-20-CDL or equivalent model from make list as specified in PS.)
S&F Flame proof flood light fittings in cast aluminium alloy LM6 consturction suitable and including 70/80 Watt LED lamp with integral reflector complete with fixing arrangement on wall/pillars complete all as specified and directed.
S&F LED light fitting, 36W, 230V Indoor decorative aluminium extruded dimension 4ft LED Battens-integrated type, with bipin holders, connector block, etc. complete with all accessories pre-wired and including connecting up with three core PVC insulated sheathed copper conductor cable of size 23/0.0076 all as specified and as directed. (Make:Crompton Cat No.LPFC-36-CDL or equivalent model from make list as specified in PS.)
S & F LED 12W retrofit lamp with polycarbonate body and aluminium heat sink cool white complete all as specified and as directed.
S&F Flame proof weather proof vertical TPN DB 415 Voilts 6 way with copper bus bar neutral link, din rail suitable for mounting MCCB as incomer and MCB SPN/SP/TPN as outgoing duly enclosed in case aluminium LM6 alloy enclosure complete withFlame proof cable glands at entry and exit of cable complete all as specified and as directed. (Note:- MCCB/MCB shall be measured and paid separately under respective items.)
S&F Flame proof weather proof SPN DB 250 volts 12 way with copper bus bar neutral link, din rail suitable for mounting MCB SPN/SP/TPN duly enclosed in cast aluminium LM6 alloy enclosure complete with Flame proof cable glands at entry and exit of cables complete all as specified and as directed. (Notes: MCBs shall be measured and paid separately under respective items.)
S&F Flame proof weather proof SPN DB 250 Voilts 8 way with copper bus bar neutral link, din rail suitable for mounting MCB SPN/SP/TPN as outgoing duly enclosed in case aluminium LM6 alloy enclosure complete with Flame proof cable glands at entry and exit of cables complete all as specified and as directed. (Notes: MCBs shall be measured and paid separately under respective items.)
Material & Labour for factory made sheet metal enclousure double door designed vertical TPN DB 4 Way DB, recessed/flushed in wall complete with copper bus bar, neutral link, dinrail suitable for mounting MCCB as incomer and MCB SPN/SP/TPN as outgoing complete all as specified and directed. (Make- Legrand Cat No.507740 or equivalent model from make list as specified in PS.)
Material and Labour for sub main wiring with 2 runs of single core 6 Sqmm (Nominal Area) FRLSH PVC insulated unsheathed multistranded copper conductor cable LT 1100 Volts grade, drawn through in and including PVC rigid conduit pipes of size 25 mm dia medium grade including earth continuity conductor using FRLSH PVC insulated unsheathed copper conductor cable of size 6 Sqmm (Nominal Area) green in colour connected to common earth dolly complete all as specified and as directed. (Note :- Two runs of main cable, one run of earth continuity copper conductor cable and one run of PVC conduit shall be measured as one run length.)
Material and Labour for sub main wiring with 2 runs of single core 10 Sqmm (Nominal Area) FRLSH PVC insulated unsheathed multistranded copper conductor cable LT 1100 Volts grade, drawn through in and including PVC rigid conduit pipes of size 25 mm dia medium grade including earth continuity conductor using FRLSH PVC insulated unsheathed copper conductor cable of size 10 Sqmm (Nominal Area) green in colour connected to common earth dolly complete all as specified and as directed. (Note :- Two runs of main cable, one run of earth continuity copper conductor cable and one run of PVC conduit shall be measured as one run length.)
Material and Labour for sub main wiring with 2 runs of 6 Sqmm(nominal area) FRLSH PVC insulated unsheathed copper conductor cable 1100 votls grade, drawn through in and including stove enameled ERW steel conduit pipe on surface with flame proof accessories of suitable size including earth continuity conductor using FRLSH PVC insulated unsheathed copper conductur cable of size 6 Sqmm (nominal area) green in colour connected to common earth dolly complete all as specified and directed. (Note:- Two runs of main cable, one run of earth continuity cable and one run of EWR steel conduit shall be measured as one run length.)
Material and Labour for sub main wiring with 2 runs of 10 Sqmm(nominal area) FRLSH PVC insulated unsheathed copper conductor cable 1100 votls grade, drawn through in and including stove enameled ERW steel conduit pipe on surface with flame proof accessories of suitable size including earth continuity conductor using FRLSH PVC insulated unsheathed copper conductur cable of size 10 Sqmm (nominal area) green in colour connected to common earth dully complete all as specified and directed. ( Note:- Two runs of main cable, one run of earth continuity cable and one run of EWR steel conduit shall be measured as one run length.)
S & F MCCBs DPX3 4 pole 63A, breaking capacity 25 KA adjustable type complete with cable connection with copper lugs complete all as specified and as directed. (Make : Legrand Cat No.420013 or equivalent model of make of ABB/Siemens.)
S & F MCCBs DPX3 4 pole 80A, breaking capacity 25 KA adjustable type complete with cable connection with copper lugs complete all as specified and as directed. (Make : Legrand Cat No.420014 or equivalent model of make of ABB/Siemens.)
S & F MCCBs DPX3 4 pole 125A, Breaking capacity 25 KA adjustable type complete with cable connection with copper lugs complete all as specified and as directed. (Make :Legrand Cat No.420056 or equivalent model of make of ABB/Siemens.)
S & F MCBs DX3 TPN 25A, Breaking capacity 10 KA Adjustable Type complete with cable connection with copper lugs complete all as specified and as directed. (Make : Legrand Cat No.408679 or equivalent model of make of ABB/Siemens.)
S & F MCBs (C-Curve) SP 40 to 50A capacity complete with cable connection with copper lugs complete all as specified and as directed. Make : ABB/Siemens/Legrand
S & F MCBs (C-Curve) SPN 40 to 50A capacity complete with cable connection with copper lugs complete all as specified and as directed. Make : ABB/Siemens/Legrand
S & F MCBs (C-Curve) SPN 10 to 32 A, breaking capacity 10 KA complete with cable connection with copper lugs complete all as specified and as directed. Make : ABB/Siemens/Legrands
S & F MCBs (C-Curve) SP 6 to 32A capacity complete with cable connection with copper lugs complete all as specified and as directed. Make : ABB/Siemens/Legrands
M&L for earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.3 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 including earth strip protection pipe of dia 15 mm (medium grage), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick and PCC (1:3:6) type C-2 concrete pit and with suitable handle funnel with watering pipe 20 mm bore (light grade) testing on completion complete all as specified & directed. (For Internal Eelectrification - 16 Nos and for External Eelectric Supply- 06 Nos)
M&L LED street light fitting, 1x20W, 230V powder coated pressure die cast aluminium compact high power with heat resistant toughened glass with 40mm dia GI bracket, etc. complete with all accessories internally prewired and including connected with three core twisted flexible wire copper conductor cable of size 22/0.0076 complete all as specified and directed. (Make: C&S electric cat No. LTESS8X2.5HPLED or equivalant modeln from make list as specified in PS.)
S&F LED light fitting 20 watt, 230 volt Indoor decorative aluminium extruded 4 feet LED Battens-integrated type, with bipin holders, connector block, etc. complete with all complete all accessories internally prewired and including connected with three core twisted flexible wire copper conductor cable of size 22/0.0076 complete all as specified and directed. (Make: C&S electric cat No. LTTB4F20WLED/W or equivalant model from make list as specified in PS.)
Material and Labour for sub main wiring with 2 runs of single core 4 Sqmm (Nominal Area) FRLSH PVC insulated unsheathed multistranded copper conductor cable LT 1100 Volts grade, drawn through in and including PVC rigid conduit pipes medium grade of required size including earth continuity conductor using FRLSH PVC insulated unsheathed copper conductor cable of size 4 Sqmm (Nominal Area) green in colour connected to common earth dolly complete all as specified and as directed. (Note :- Two runs of main cable, one run of earth continuity copper conductor cable and one run of pvc conduit shall be measured as one run length.)
Supply and Fixing Water Heater(Geyser) storage type 25 Ltr capicity vertical, thermoplastic body having max EER rating including grouting of stove enameled fastener by drilling in wall and provn of 02 Nos 304 grade stainless steel reinforced flexible connection pipe 600mm long with brass nuts and 02 Nos brass chromium plated angular valves suitable for 15mm bore pipe of water supply complete all as directed and specified.
INTERNAL WATER SUPPLY. S&F 15 mm bore brass bib tap cast copper CP high pressure with long shank and cup, capstan head, screwed down complete all as specified and directed.
S&F 15 mm bore angle cock brass CP high pressure with capstan head, long shank screwed down complete all as specified and directed.
S&F 15 mm bore brass concealed stop cock CP high pressure with capstan head, long shank and cup screwed down complete all as specified and directed.
ROAD. Material & labour for 200 mm thick (Compacted thicknes) GSB (Granular sub base) over compacted sub grade with stone aggregate of grading II, spreading, leveling, rolling with power roller exc 8 tonne not exc 12 tonne and consolidating to required gradient and camber complete all as specified and directed.
M&L for Wet mix macadam (WMM) 100 mm thick (compacted thickness) with course aggregate of (63mm to 40mm) spread, rolled & consolidated using power roller exc 8 tonne but not exc 12 tonne as specified to required gradient and camber complete all as specified and as directed.
M&L for 2 mm thick painting to road surfaces as in lines, dashes, arrows, letters, zebra crossing etc on roads, pavements and the like etc. with thermoplastic road marking paint including applying type-II glass beads dispensed from the inbuilt dispenser unit @ 250-300 gm/Sqm simulteneously complete all as per manufacturer's instruction and as directed.
SEWAGE DISPOSAL. Construction of Septic Tank for 25 users complete all as shown on drawings and as specified.
Construction of Soakage Well for 25 users complete all as shown on drawings and as specified.
EXTERNAL WATER SUPPLY. M&L Cutting to existing CI pipe line of 80 mm dia including taping and fixing CI Tee for 80mm dia branch connection complete all as specified and directed..
Supply and fixing,CI Sluice Valves, flanged with steel spindle and CI wheel confirming to IS-14846(2000) of class 1.0 PN, 80 mm dia complete all as specified and directed.
Construciton of brick masonry valve pit / chamber of internal dimension 90 cm x 90 cm x 90 cm depth with sub class 'B' bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:3:6) type D2 (Using 40 mm graded breoken stone aggregate) as in foundaitn lean concrete, PCC (1:3:6) type C1 ( Using 20 mm graded broken stone aggregate) as in bedding and copping, MS frame with 40 x 40 x6 mm angle iron, 3 mm thick MS sheet cover plate with locking arrangement hinges and two coats of synthetic enamel paint over a coat of red oxide primer including preparation of steel surface, three coats of white wash to plastered surface (exposed to view), excavation in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed.
All as per item Ser No 19.46 here-in-before but of size 45cmx45cmx60cm complete.
EXTERNAL ELECTRIC SUPPLY. S&F HT 11 KV LBSF Panel outdoor complete with 630 Amp load break switch,11 KV HT HRC fuse set, Earth Switch, Bus bar rating 11 KV 630 Amps, PCC etc. complete all as specified and directed. (Make :- M/S EL-TECH CONTROL or equivalant from make list as specified in PS.)
S&F HT 11 KV-05 Nos LBSF Panel outdoor complete with 630 Amp load break switch,11 KV HT HRC fuse set, Earth Switch, Bus bar rating 11 KV 630 Amps, PCC etc. complete all as specified and directed. (Make :- M/S EL-TECH CONTROL or equivalant from make list as specified in PS.)
Supply, Installation, testing, commissioning and testing of Fabrication of LT outdoor 5 segment Cubical panel Board with vertical bus chamber of size 1.5m x 1.2m x0.8m made of 3.0 mm thick CRCA sheet and framing with 40mm x 40mm x 6mm angle iron, floor mounting type, with 1500 Amps copper bus bar, powder coated painted including internal wiring complete providing suitable of size copper cable/strip as required or as per manufacturer"s recommendation with following accessories:-(Main Panel at S/S) Incoming :- (a) ACB 4 pole, Drawout type fitted with intelligent release Micropro 3.1 rating 1000 A 50 KA -01 No (b) Digital single function function volt meter -01 No (c) Digital single function function amp meter with suitable size CT's -01 No (d) LED indicator lamp R-Y-B - 01 Set Out going:- (a) MCCB 4 pole,415 Volts 400 A, 50 KA -01 No (b) MCCB 4 pole,415 Volts 320 A,35 KA -01 No (c) MCCB 4 pole,415 Volts 160 A, 25 KA -02 Nos (d) MCCB 4 pole,415 Volts 400 A, 35 KA -01 No (e) MCCB 4 pole,415 Volts 100 A, 16 KA -01 No (f) MCB TPN,415 Volts,10 KA 20 A, 10 KA -02 Nos (g) Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure - 01 No
Supply, Installation, testing, commissioning and testing of Fabrication of LT outdoor 5 segment Cubical pannel Board with vertical bus chamber of size 1.0m x 1.0m x 0.8m made of 3.0 mm thick CRCA sheet and framing with 40mm x 40mm x 6mm angle iron, floor mounting type, with 450 Amps copper bus bar, powder coated painted including internal wiring complete providing suitable of size copper cable/strip as required or as per manufacturer"s recommendation with following accessories:-(For MMPU-I Bldg) Incoming :- (a) MCCB 4 pole, 415 Volts,320 A , 35 KA -01 (b) Digital single function function volt meter -01 (c) Digital single function function amp meter with suitable size CT's -01 (d) LED indicator lamp R-Y-B - 01 Set Out going:- (a) MCCB 4 pole,415 Volts, 100 A, 25 KA -02 Nos (b) MCCB 4 pole,415 Volts, 63 A, 16 KA -01 No (c) MCB TPN,415 Volts 40 A,16 KA -02 Nos
Supply, installation, commissioning and testing of 500 KVA, Silent Diesel Engine driven generating set outdoor type 415 Volts, 3 phase 4 wire, engine as per IS : 10001/10002 and alternator as per IS : 13364 complete with relay panel for automatic starting on mains failure, control panel having meters, sound proof canopy and concrete foundation complete all as specified and directed comprising of following:- (A) a) Fly wheel to suit flexible coupling. b) Flexile coupling with guards. c) Dry type air cleaners with filters. d) Lubricating oil filter, fuel filter, fuel pre filter. e) Anti-vibration pads-quantity and type as recommended by manufacturer. f) Fuel injection system with injector pump, nozzles, governor(electronic) of suitable capacity. g) Electric start equipment. h) Lead acid storage maintenance free battery 2x12V DC of suitable rating with charging alternator, ammeter, as recommended by manufacturers make: As per OEM standard along with copper battery lead and connector. i) Battery rack made out of MS angle iron 40mmX40mmX5mm and 150mm height. j) Standard safety device. k) Daily service fuel tank of suitable capacity for running 12 hrs non-stop on Full Load with mechanical level indicator, detachable strainer, drain cock, fuel outlet, air vent and locking arrangement etc, including fuel pipe connections. l) Exhaust silencer(Residential silencer) with exhaust piping of suitable size brought out side on top of size 76.5 mm dia and complete length of silencer and exhaust piping continuously wrapped with 12 mm dia asbestos rope and suitable anti vibration arrangement around pipe passing through wall.
Serial Item No. 19.53 (Contd....) m) LCD display type control panel as per manufacturer's instructions indicating KWH, KVA, PF, Volts, Amps, Hz, RPM, Hour, Oil pressure, Oil temprature, coolent temprature, fuel level, battery charging ammeter, battery charging lamp and incator lamp (RYB), panel duly prewired and displaying protection and safetys as under:- aa) Protection:- short circuit, overload, over speed, earth fault as standard and reverse power as optional. ab) Safeties:- Auto shut down, visual & audio alarm for low lub oil pressure, high coolant temperature, low fuel level, canopy temperature & radiator water level. (B) Alternator 500 KVA brushless type at 0.8 power factor, self regulated, self excited, screen protected 3 phase with neutral 415 volts 50 HZ, 1500 RPM, as per IS:13364/IS-4722 complete with automatic voltage regulator, having voltage regulation +/-1%, SPDP enclosure including making cable connections, insulation class-H and alternator control panel as supplied by manufacturer. (C) Base frame sturdy, MS fabricated, channel iron base frame for mounting the engine & alternator with anti vibration pads. (D) Acoustics enclosure of suitable size to accommodate DG set 500 KVA, modular construction, fabricated out of 3 mm thick, cold annealed CRCA sheet duly epoxy painted doors to be provided with high quality EDPN gasket, duly epoxy painted. The canopy to be equipped with heavy duty fans of reputed manufacturer for air circulation and cooling the canopy. Rock wool of requisite density per Kg/m3 to be used for insulation. Enclosure to be provided with one light point controlled with one switch for internal lighting. Noise level at one meter to be 75 decibels @ one meter in line as per CPCB norms. (E) Repair tools to be supplied as under:- (i) Ring spanner set of 10- 01 set. (ii) Screw driver 6",9", 12", 14" - 01 No Each.
Serial Item No. 19.53 (Contd....) (iii) Adjustable spanner 12" - 01 No. (iv) Double end spanner set of 10 - 01 No. (v) Cutting pliers insulated and nose plier 10" & 12" - 01 No. (vi) Techo meter - 01 No. (vii) Tool kit box - 01 No. (F) Maint spares to be supplied as under:- (i) All type of filters - 02 Each. (ii) V-Belt - 01 Set NOTE:- (i) The engine of DG set suitably conditioned to suit the climatic condition, so as to give desire outputs including and testing up to 10% over load. (ii) Foundation of the DG set (PCC/RCC) will be provided by the contractor and will be made as per the manufacturer instruction. Cost of foundation is deemed to be included in the rate of this item. (iii) The items required for testing of DG set e.g. fuel, tripod, tools, water tank etc and panel as below shall be provided by the contractor and the rate of which is deemed to be included in the rate of item. (iv) Testing of DG set will be carried out as specified.
All as per Ser Item No 19.53 to 19.55 here-in-before but for 250 KVA, Silent Diesel Engine driven generating set complete.
S&F LED street light 72 W IP 65, complete all as specified and directed. (Make Crompton cat ref No LSTP-72-CDL or equivalant from make list as specified in PS.)
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
M&L Earthing complete with GI earth plate elecrode of size 60cm×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to GI earth strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work RCC cover 50mm thick and PCC(1:3:6) type C-2 concrete pit with suitable lifting handle and angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15 cm compacted thickness all around the earth electrode with funnel and 20 mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect, protected by 40 mm bore (medium grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion complete all as specified and as directed. (For External Eelectric Supply - 38 Nos, for Lightening Protection - 09 Nos and for Fire Fighting - 06 Nos)
M&L Earthing complete with copper plate elecrode of size 60cm×60cm×3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper earth strip 20 mm x 3 mm by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work RCC cover 50mm thick and PCC(1:3:6) type C-2 concrete pit with suitable lifting handle and angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15 cm compacted thickness all around the earth electrode with funnel and 20 mm bore galvanized iron watering pipe (light gradde) wire mesh, copper lugs, complete in all respect protected by 25 mm bore (medium grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion complete all as specified and as directed. (For External Eelectric Supply- 52 Nos and for Lightening Protection - 18 Nos)
Supply and fixing Elastomer electric insulating mat (Not skid type) class 'B' 2.50mm thick suitable for 11KV rating installtions all as per IS:15652-2006 complete all as directed. (.Make- JB, Safe- Volt, Jyoti)
Supply and fixing Elastomer electric insulating mat (Not skid type) class 'A' 2.00mm thick suitable for 440V rating installtions all as per IS:15652-2006 complete all as directed. (Make- JB, Safe- Volt, Jyoti)
Supply and fixing octagonal pole 8mtr long made of hot dipped GI tube having bottom dia 135mm, top dia 70mm, base flange size 225x225x16mm, single arm bracket 1000mm, fixing nut & bolts of high tensile MS rod, template, TPN connector for loopin & out of main cable, MCP SP,6A rating, cable copper conductor 3 core 1.5 Sqmm from junction box to light fitting complete including necessary PCC foundation for mounting of pole as per manufacture's specifications and as directed.
FIRE FIGHTING. S & F 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903 complete all as specified and directed.
S & F Hose box for keeping 2 Nos hose pipe of length 15 meter each, branch pipe, nozzle, coupling etc of MS sheet of thickness 2.0 mm complete all as specified and directed.
Supply and fixing Fire hydrant stand post with provision of single outlet conforming to IS 908 complete all as specified and directed.
Construction of brick masonry valve pit of size 120 cm x 120 cm x 120 cm (internal dimensions ) with one brick thick wall in cement mortar 1:4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate ) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in bedding and coping and 10mm thick cement plaster in CM (1:4) internally and externally up to 15cm below ground level and providing 50 x 50 x 6 mm angle iron frame all around the fixed point by means of 4 Nos holdfast 150 mm long made out of flat iron 40mm x 6mm embedded in PCC block (1:2:4) type B-1 (using 20 mm graded crushed stoned aggregate) of size 250mm x 200mm x 150 mm including provision of hinges welded with angle iron frame and MS sheet cover 3mm thick, MS handle of suitable size welded with MS cover and suitable locking arrangement including 65 mm dia Godrej pad lock and applying two coats of synthetic enamel paint over a coats of red oxide primer including necessary excavation and earth work in soft/ loose soil complete all as specified and as directed.
FIRE ALARM. Supply and installation of the flowchart based programmable RTU along with battery back up for incase of power fail SMS and wireless modem suitable for GSM/GPRS based communication system to be mounted in RTU enclosure including the following complete all as specified and as directed :- - Input Out put as per requirement in our system - 3 serial port - Digital inputs (optical isolation) - Digital outputs -Isolated Analog Inputs -Local Display, membrane key board and data storage -Compatibility with GSM Modem -Isolation transformer for RTU protection- 1 No. -One panel in each FACP and one panel for fire section with mimik panel. (Note: One GSM sim card shall be installed in the RTU with rental & SMS charges, Rs 350.00 per month, for the period of two years, from the date of completion of work, shall be provided by the contractor and cost of the same shall deemed to be included in the unit rate.)
Supply & Fixing of of three core copper conductor of size 2.5 sq mm FRLS Flexible shielded cable all as specified and directed
Supply & Fixing of two core copper conductor of size 1.5 sq mm FRLS Flexible shielded cable all as specified and directed
M&L for boring holes under road/pavement/hard by trenchless technology using ultrasound technique with necessary machine suitable for and including 25 mm dia GI Pipe light grade complete all as specified and directed.
S & F cable route indicator made up of CI 100mm dia and fixed with 60 cm long angle iron of size 50mm x 50mm x 6 mm embeded in PCC 1:4:8 type D2 (using 40 mm graded broken stone aggregate) of size 30cm x 30cm x 30 cm complete all as specified and directed.
Supply and laying single mode optical fibre cable, 4 core in and including 20mm dia PVC conduit in trenches, wall/floor for connecting fire alarm control panels, to be installed in different location, including joint and jointing materials as required complete all as specified and directed.
EOT CRANE. Design, supply, installation, testing and commissioning of flame proof electrically operated over head travelling EOT crane, double girder, having span of 11.0m, long travel 10.0 m of capacity 3.0 Ton and clear hook height 3.50 m with mobile pedent control system (For Packing Unpacking Cell) considering following conditions complete all as specified and directed:- (i) Height available for working/stacking of equipments should be 3.5m and rest height is to cater for crane installation. (ii) The operation and micro speed of crane should be as following:- (a) Main Hoist:- 4.5m/min (b) Micro in main Hoist - 0.8 m/min. (c) Cross travel - 20 m/min (d) Micro in cross travel - 0.5 m/min (e) Long travel - 14 m/min (f) Micro in long travel- 0.5m/min (iii) EOT crane fitted should be comply with the saftey specification such as limit swiches, alarm, guards, isolating switches, emergency stop button and interlocking, power and control cabling complete etc confirming to IS-807, IS-3177, IS-3938 specifications. (iv) Design, Supply, Installation, Testing and Commissioning of Crane shall be undertaken through Manufacturers/ Specialist Firms. (v) Design of crane and proof checking of design from any of Government Chartered Engineers within 2 months from the date of acceptance of tender.
Design, supply, installation, testing and commissioning of flame proof electrically operated over head travelling EOT crane, double girder, having span of 8.0m, long travel 10.0 m of capacity 3.0 Ton and clear hook height 3.50 m with mobile pedent control system (For Pyrotechnic Cell) considering following conditions complete all as specified and directed:- (i) Height available for working/stacking of equipments should be 3.5m and rest height is to cater for crane installation. (ii) The operation and micro speed of crane should be as following:- (a) Main Hoist:- 4.5m/min (b) Micro in main Hoist - 0.8 m/min. (c) Cross travel - 20 m/min (d) Micro in cross travel - 0.5 m/min (e) Long travel - 14 m/min (f) Micro in long travel- 0.5m/min (iii) EOT crane fitted should be comply with the saftey specification such as limit swiches, alarm, guards, isolating switches, emergency stop button and interlocking, power and control cabling complete etc confirming to IS-807, IS-3177, IS-3938 specifications. (iv) Design, Supply, Installation, Testing and Commissioning of Crane shall be undertaken through Manufacturers/ Specialist Firms. (v) Design of crane and proof checking of design from any of Government Chartered Engineers within 2 months from the date of acceptance of tender.
Design, supply, installation, testing and commissioning of flame proof electrically operated over head travelling EOT crane, double girder, having span of 8.0m, long travel 13.5 m of capacity 3.0 Ton and clear hook height 3.50 m with mobile pedent control system (For Meteor Pyrotechnic Test Cell) considering following conditions complete all as specified and directed:- (i) Height available for working/stacking of equipments should be 3.5m and rest height is to cater for crane installation. (ii) The operation and micro speed of crane should be as following:- (a) Main Hoist:- 4.5m/min (b) Micro in main Hoist - 0.8 m/min. (c) Cross travel - 20 m/min (d) Micro in cross travel - 0.5 m/min (e) Long travel - 14 m/min (f) Micro in long travel- 0.5m/min (iii) EOT crane fitted should be comply with the saftey specification such as limit swiches, alarm, guards, isolating switches, emergency stop button and interlocking, power and control cabling complete etc confirming to IS-807, IS-3177, IS-3938 specifications. (iv) Design, Supply, Installation, Testing and Commissioning of Crane shall be undertaken through Manufacturers/ Specialist Firms. (v) Design of crane and proof checking of design from any of Government Chartered Engineers within 2 months from the date of acceptance of tender.
Design, supply, installation, testing and commissioning of flame proof electrically operated over head travelling EOT crane, double girder, having span of 12.0m, long travel 11.0 m of capacity 3.0 Ton and clear hook height 3.50 m with mobile pedent control system (For MMPU-II SCALP) considering following conditions complete all as specified and directed:- (i) Height available for working/stacking of equipments should be 3.5m and rest height is to cater for crane installation. (ii) The operation and micro speed of crane should be as following:- (a) Main Hoist:- 4.5m/min (b) Micro in main Hoist - 0.8 m/min. (c) Cross travel - 20 m/min (d) Micro in cross travel - 0.5 m/min (e) Long travel - 14 m/min (f) Micro in long travel- 0.5m/min (iii) EOT crane fitted should be comply with the saftey specification such as limit swiches, alarm, guards, isolating switches, emergency stop button and interlocking, power and control cabling complete etc confirming to IS-807, IS-3177, IS-3938 specifications. (iv) Design, Supply, Installation, Testing and Commissioning of Crane shall be undertaken through Manufacturers/ Specialist Firms. (v) Design of crane and proof checking of design from any of Government Chartered Engineers within 2 months from the date of acceptance of tender.
Design, supply, installation, testing and commissioning of flame proof electrically operated over head travelling EOT crane, double girder, having span of 18.0m, long travel 36.0 m of capacity 5.0 Ton and clear hook height 3.50 m with mobile pedent control system (For 03 x ESH) considering following conditions complete all as specified and directed:- (i) Height available for working/stacking of equipments should be 5.0m and rest height is to cater for crane installation. (ii) The operation and micro speed of crane should be as following:- (a) Main Hoist:- 4.5m/min (b) Micro in main Hoist - 0.8 m/min. (c) Cross travel - 20 m/min (d) Micro in cross travel - 0.5 m/min (e) Long travel - 14 m/min (f) Micro in long travel- 0.5m/min (iii) EOT crane fitted should be comply with the saftey specification such as limit swiches, alarm, guards, isolating switches, emergency stop button and interlocking, power and control cabling complete etc confirming to IS-807, IS-3177, IS-3938 specifications. (iv) Design, Supply, Installation, Testing and Commissioning of Crane shall be undertaken through Manufacturers/ Specialist Firms. (v) Design of crane and proof checking of design from any of Government Chartered Engineers within 2 months from the date of acceptance of tender. Note (For Item Ser No 19.77 to 19.81):- (a) VVVFD to be provided for spread control in all motions. (b) Crane fabricator to physically check all internal bldg dimensions on ground before undertaking fabrication work.
COMPRESSED AIR SUPPLY, NITROGEN AND OXYGEN GAS PIPE LINE . M & L for copper pipe 28mm dia wall thickness 0.90mm for compressed air supply complete all specified and directed.
M & L for copper pipe15mm dia wall thickness 0.90mm for connection of wall outlet (Nozzle) @1m for Nozzle complete all as specified and directed.
M & L for wall outlet (Nozzle) complete all as specified and directed.
M & L for Pressure reducer valve complete all as specified and directed.
S&F Flexible pipe for house pipe 6mm dia and 1m long for each connection complete all as directed.
S & F Pressure Regulator for controlling pressure for each gas pipe complete all specified and directed
M&L for reinforced concrete pipes 1200mm dia class NP3 laid and jointed complete with collars completeall as directed.
Ditto all as per Srl Item No 19.89 here-in-before but for next 11 calendar months after completion of 1st 11 calender months.
Ditto all as per Srl Item No 19.89 here-in-before but for next 11 calendar months after completion of 2nd 11 calender months.
Ditto all as per Srl Item No 19.89 here-in-before but for next 03 calendar months after completion of 3rd 11 calender months.
PRIME COST SUM The prime cost is to be used as directed by the Accepting Officer vide conditioin 1(v) and 5 of IAFW-2249 (a) Lump sum price worked out by the tenderer for prime cost sum of Rs.30,00,000.00 for provison of 06 Nos of Blast Proof Door for MMPU-1 buildings including fixing arrangements as approved by GE. (b) The contractor is to quote the amount in Col 6 of this BOQ adding his overhead and profit. The amount shall be adjusted proportionately to the sum actually expended against Prime Cost Sum. Notes:- (i) Item (s) covered under Prime Cost Sum shall be ordered as per condition 5 of IAFW-2249. (ii) Contractor will quote rate for this item upto maxomum of Rs. 34,50,000.00 resulting maximum percentage of 15%. If contractor quotes rate more than Rs 34,50,000.00, amount column shall automatically adapt amount of 34,50,000.00 and percentage column shall adapt percentage 15% . In case of acceptance of such quoted tender, rate quoted against this item shall be amended to 34,50,000.00 through alteration and contractor will have no claim on this account. However if contractor quotes rate less than 34,50,000.00, quoted amount and derived percentage shall be reflected as such under amount column & percentage column.
REWINDER TECHNO ELECTRICALS
SARINS
M.P. SITANI AND SONS
East India Construction Company
Rds Project ltd.
AKM CONSTRUCTION AND ENGINEERING LLP
surendra infrastructure pvt ltd
Hariom Projects Pvt Ltd
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.07 MB
Download all tender documents and submit your bid