Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹14.3 L+₹51,850 (3.77%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹15.0 L+₹1.2 L (8.87%)Rejected-Finance FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | Rejected-Technical 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | - | Rejected-Technical REJECTED DUE TO LACK OF REQUIRED CATEGORY OF ENLISTMENT | |
| 5 | Rejected-Technical | - | Rejected-Technical REJECTED DUE TO LACK OF REQUIRED CATEGORY OF ENLISTMENT |
| Sl No | Description | Qty | Unit | SKS Electricals L2 | UNIQUE ENGINEERS L3 | shanti enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00 | Servicing and Maintenance of Micro Processer based fire alarm control panel of Make Apollo installed at MH khadki Phase - I building, comprising of six loop data card, battery, LCD/LED display panel, buzzers with software programs etc, including testing by OEM all as specified and as directed.
The details of the Fire alarm panel are as under:-
(a) Main Control panel of Fire Alarm System - (01+02) Nos, Make : Apollo -TD1
(b) Heat and Smoke detectors - 661 Nos, Make :Agni
(c) Battery 12V, 7AH to 10 AH - 24 No, Make : Exide.
(d) Response indicator - 221 Nos. , Make :Agni
(e) Manual Call points- 40 Nos Make : XP95
(f) Dual tone electronic Hooter- 06 Nos , Make Agni
(g) Repeater Panel - 09 Nos, Make :Apollo
(h) Control Module for AHU - 12 Nos , Make Apollo
Notes :-
(i) The Rates are inclusive of regular inspection of authorised OEM, once in a month.
(ii) The maint and servicing includes clearing the fault in loop wiring , cleaning the heat/smoke detectors with blowers, response indicator, MCP, Sounder cum Strobe with control module etc all as directed by Engineer In Charge.
(iii) Major Spares required for maintenance of the above panel shall be measured and paid separately under relevant item No 2 to 5.
(iv) The rates are inclusive of cleaning of Fire panels rooms as directed by JE E/M/Engr-in-charge. | 9 | Each Job | 13,500 ₹1,21,500 | 13,800 ₹1,24,200 | 10,000 ₹90,000 Lowest |
| 2.00 | Supply, Installation, commissioning and testing of Apollo - TD1 addressable single loop fire alarm repeater panel with primary supply voltage 230volts AC (max upto 260 volts) and secondary supply upto voltage 30 DC, The panel should be competable in operating temperature upto 50 degree centigrate and operating humidity level less than 95 % (non condensed) with graphic touch LCD display complete including dismantling the old panel all as specified and directed.
Note :- (i) The panel should be as per the OEM recommendations.
(ii) Site inspection for maintenance of Fire alarm system is necessary before quoting the tender. | 5 | Each | 26,000 ₹1,30,000 Lowest | 26,500 ₹1,32,500 | 51,000 ₹2,55,000 |
| 3.00 | S&F in repairs Apollo addressable smoke detector all as specified and directed. | 174 | Each | 2,600 ₹4,52,400 Lowest | 2,700 ₹4,69,800 | 2,600 ₹4,52,400 Lowest |
| 4.00 | S&F in repairs Apollo addressable manual Call point all as specified and directed. | 18 | Each | 3,000 ₹54,000 Lowest | 3,100 ₹55,800 | 3,000 ₹54,000 Lowest |
| 5.00 | S&F in repairs Apollo addressable sounder all as specified and directed. | 14 | Each | 3,500 ₹49,000 Lowest | 3,590 ₹50,260 | 4,000 ₹56,000 |
| 6.00 | Servicing and Maintainence of Micro processer based Fire alarm control panel of Make Zicom installed at MH kirkee Phase -II building having six loop data card, battery, LCD panel, buzzers with required software programs etc, including testing by OEM all as specified and directed.
The details of the Fire alarm panel are as under :-
(a) Fire alarm Main Panel - 28 Nos, Make : Agni/Ravel/Zicom
(b) Heat and smoke detectors - 1623 Nos Make : Agni/ravel/System Sensor
(c) Battery 12V, 7AH/10 AH - 56 Nos , Make : Exide
(d) Response indicator - 600 Nos Make :Agni/Ravel
(e) Manual Call points- 48 Nos Make : Agni
(f) Hooter - 48 Nos, Make Agni/Ravel/Zicom
(g) Control Modual for AHU - 24 Nos Make :Agni/Ravel/Zicom
Notes :-
(i) The Rates are inclusive of regular inspection of authorised OEM, once in a month.
(ii) The maint and servicing includes clearing the fault in loop wiring , cleaning the heat/smoke detectors with blowers, response indicator, MCP, Sounder cum Strobe with control module etc all as directed by Engineer In Charge.
(iii) Spares required for maintenance of the above panel shall be measured and paid separately under relevant item No 7 to 11.
(iv) The rates are inclusive of cleaning of Fire panels rooms as directed by JE E/M/Engr-in-charge. | 9 | Each Job | 13,500 ₹1,21,500 | 14,000 ₹1,26,000 | 10,000 ₹90,000 Lowest |
| 7.00 | Supply, Installation,commissioning and testing of Ravel/Agni (RE-102/104), 4 zone microprocessor based Conventional Fire alarm control panel. The panel is capable to operate conventional input devices such as 2 wire smoke detectors , pull stations and other normally open contact devices. The out puts include notification appliance circuits(sounders) , Three form C relays 2 for alarm, 1 for fault and RS485 port to interface with remote annunciator (optional). It supervises all wiring, AC voltage and battery level. complete including dismantling the old panel all as specified and directed.
The panel comprises of the following Features:-
(i) Operates on 220 volts , 50 Hz AC supply
(ii) Stand by battery back up withn built in charging
(iii) Low battery visual warning with audiable tone
(iv) Zone isolation facility with loop voltage cut off
(v) 16X2 LCD display and Error free Fire/Fault status in unambiguos colored LED indication.
(vi) Programmable auto silence and Key pad lock.
(vii) Compatible to all types of conventional detectors | 5 | Each | 18,500 ₹92,500 | 19,200 ₹96,000 | 7,000 ₹35,000 Lowest |
| 8.00 | S&F in repairs Agni/System sensor/Zicom smoke detector all as specified and directed. | 148 | Each | 1,000 ₹1,48,000 | 1,100 ₹1,62,800 | 900 ₹1,33,200 Lowest |
| 9.00 | S&F in repairs Ravel/Agni/Zicom system sensor manual call point all as specified and directed. | 20 | Each | 1,000 ₹20,000 | 1,100 ₹22,000 | 900 ₹18,000 Lowest |
| 10.00 | S&F in repairs Agni/Zicom system sensor sounder cum flasher all as specified and directed. | 20 | Each | 1,600 ₹32,000 | 1,650 ₹33,000 | 1,200 ₹24,000 Lowest |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
13 Oct 2025, 6:00 pmClosed
CWE Khadki Pune
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
REPAIR REPLACEMENT AND MAINTENANCE OF FIRE ALARM SYSTEM AND CONNECTED WORKS AT MILITARY HOSPITAL UNDER GE MH AND RH KHADKI
2025_MES_731017_1
CWE/KKE/TOKEN-131 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CWE Khadki Pune
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE MH AND RH KHADKI
₹28,000
Yes
16 Dec 2025
15 Sept 2025
15 Oct 2025
15 Sept 2025
13 Oct 2025
29 Sept 2025
15 Sept 2025 - 22 Sept 2025
Amount
Servicing and Maintenance of Micro Processer based fire alarm control panel of Make Apollo installed at MH khadki Phase - I building, comprising of six loop data card, battery, LCD/LED display panel, buzzers with software programs etc, including testing by OEM all as specified and as directed. The details of the Fire alarm panel are as under:- (a) Main Control panel of Fire Alarm System - (01+02) Nos, Make : Apollo -TD1 (b) Heat and Smoke detectors - 661 Nos, Make :Agni (c) Battery 12V, 7AH to 10 AH - 24 No, Make : Exide. (d) Response indicator - 221 Nos. , Make :Agni (e) Manual Call points- 40 Nos Make : XP95 (f) Dual tone electronic Hooter- 06 Nos , Make Agni (g) Repeater Panel - 09 Nos, Make :Apollo (h) Control Module for AHU - 12 Nos , Make Apollo Notes :- (i) The Rates are inclusive of regular inspection of authorised OEM, once in a month. (ii) The maint and servicing includes clearing the fault in loop wiring , cleaning the heat/smoke detectors with blowers, response indicator, MCP, Sounder cum Strobe with control module etc all as directed by Engineer In Charge. (iii) Major Spares required for maintenance of the above panel shall be measured and paid separately under relevant item No 2 to 5. (iv) The rates are inclusive of cleaning of Fire panels rooms as directed by JE E/M/Engr-in-charge.
Supply, Installation, commissioning and testing of Apollo - TD1 addressable single loop fire alarm repeater panel with primary supply voltage 230volts AC (max upto 260 volts) and secondary supply upto voltage 30 DC, The panel should be competable in operating temperature upto 50 degree centigrate and operating humidity level less than 95 % (non condensed) with graphic touch LCD display complete including dismantling the old panel all as specified and directed. Note :- (i) The panel should be as per the OEM recommendations. (ii) Site inspection for maintenance of Fire alarm system is necessary before quoting the tender.
S&F in repairs Apollo addressable smoke detector all as specified and directed.
S&F in repairs Apollo addressable manual Call point all as specified and directed.
S&F in repairs Apollo addressable sounder all as specified and directed.
Servicing and Maintainence of Micro processer based Fire alarm control panel of Make Zicom installed at MH kirkee Phase -II building having six loop data card, battery, LCD panel, buzzers with required software programs etc, including testing by OEM all as specified and directed. The details of the Fire alarm panel are as under :- (a) Fire alarm Main Panel - 28 Nos, Make : Agni/Ravel/Zicom (b) Heat and smoke detectors - 1623 Nos Make : Agni/ravel/System Sensor (c) Battery 12V, 7AH/10 AH - 56 Nos , Make : Exide (d) Response indicator - 600 Nos Make :Agni/Ravel (e) Manual Call points- 48 Nos Make : Agni (f) Hooter - 48 Nos, Make Agni/Ravel/Zicom (g) Control Modual for AHU - 24 Nos Make :Agni/Ravel/Zicom Notes :- (i) The Rates are inclusive of regular inspection of authorised OEM, once in a month. (ii) The maint and servicing includes clearing the fault in loop wiring , cleaning the heat/smoke detectors with blowers, response indicator, MCP, Sounder cum Strobe with control module etc all as directed by Engineer In Charge. (iii) Spares required for maintenance of the above panel shall be measured and paid separately under relevant item No 7 to 11. (iv) The rates are inclusive of cleaning of Fire panels rooms as directed by JE E/M/Engr-in-charge.
Supply, Installation,commissioning and testing of Ravel/Agni (RE-102/104), 4 zone microprocessor based Conventional Fire alarm control panel. The panel is capable to operate conventional input devices such as 2 wire smoke detectors , pull stations and other normally open contact devices. The out puts include notification appliance circuits(sounders) , Three form C relays 2 for alarm, 1 for fault and RS485 port to interface with remote annunciator (optional). It supervises all wiring, AC voltage and battery level. complete including dismantling the old panel all as specified and directed. The panel comprises of the following Features:- (i) Operates on 220 volts , 50 Hz AC supply (ii) Stand by battery back up withn built in charging (iii) Low battery visual warning with audiable tone (iv) Zone isolation facility with loop voltage cut off (v) 16X2 LCD display and Error free Fire/Fault status in unambiguos colored LED indication. (vi) Programmable auto silence and Key pad lock. (vii) Compatible to all types of conventional detectors
S&F in repairs Agni/System sensor/Zicom smoke detector all as specified and directed.
S&F in repairs Ravel/Agni/Zicom system sensor manual call point all as specified and directed.
S&F in repairs Agni/Zicom system sensor sounder cum flasher all as specified and directed.
S&F in repairs 12 volt 7 AH/10AH battery all as specified and directed.
Supply, draw, connecting, testing and commissioning of 2 core 1.5 sq mm stranded copper conductor, PVC insulated PVC sheathed FRLS, flexible armoured cable laid on ceiling/wall clamped with aluminium clamps/ drawn in ERW pipe all as specified and directed . Note :- (i) The cables are to be drawn through the false ceilings, laid in floors, fixed to walls as per the site requirements. (ii) The conduits are to be measured and paid seperately under relevent item No 13.
Supply and laying of Mild Steel Stove enameled black conduit alongwith the accessories such as tees, bends, elbows, bell mouth ends and all fixing accessories such as couplers, locknuts, saddles, pipe hook etc. on surface/recess including painting, in case of recessed conduit, cutting the wall and making good the same for of recessed conduit of size 25 mm dia all as specified and directed.
Dismantling and taking out ABC type Fire Extinguisher of capacity 6 kgs by removing hose, valve assembly and depressurizing the extinguisher and transporting to approved testing Lab/workshop and carry out complete over hauling of cylinder, valves etc including purging, testing and refilling the cylinder upto 6 kg (as per OEM recommendations) ABC powder as per IS 2878 complete including one coat of synthetic enamel paint on the cylinder with appropriate colour, labelling and transporting back to site, installing on its existing position all as directed by the Engr-in-charge.
Dismantling and taking out Fire Extinguisher CO2 type 4.5 Kg capacity removing discharge hose nozzles and transporting to approved testing Lab/workshop and carry out complete over hauling of cylinder, plunger nozzles,valves etc including purging, High pressure testing and refilling the cylinder upto 4.5kg net CO2 all as per IS 2878 complete including one coat of synthetic enamel paint on the cylinder with appropriate colour, labelling and transporting back to site, installing on its existing position all as directed by the Engr-in-charge.
SKS Electricals (BID ID -3442216)
UNIQUE ENGINEERS (BID ID -3443157)
Bidder Name
UNIQUE ENGINEERS
shanti enterprises
SKS Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .