| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 BIDDER | |
| 2 | L2₹26.4 L+₹2.3 L (9.69%)Rejected-Finance HOUSE NO 2 BYELANE ANJALI UPA PATH AJANTA PATH SURVEY P O BELTOLA GUWAHATI 781028 ASSAM | GUWAHATI | KAMRUP METRO | ASSAM | 781028 | L2 | Rejected-Finance DUE TO OTHER THAN L1 BIDDER | |
| 3 | L3₹27.0 L+₹2.9 L (12.2%)Rejected-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance DUE TO OTHER THAN L1 BIDDER |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
21 Jun 2025, 6:00 pmClosed
GE DINJAN NO 02
GE DINJAN NO 02 POST - DINJAN DIST - DIBRUGARH PIN - 786183 ASSAM
REPAIR TO DRAIN BOUNDARY WALL SECURITY WALL GATE FENCING PATH CULVERT ETC IN ZONE-III IVA AND ZONE IVB AT LEKHAPANI UNDER GE DINJAN NO 2
2025_MES_709445_1
8878/E8
Open Tender
Civil Works - Others
Item Rate
180 days
DINJAN
AS PER TENDER DOCUMNETS
9 documents required · 9 mandatory
₹500
GE DINJAN NO 02
₹50,000
Yes
10 Jul 2025
21 May 2025
24 Jun 2025
21 May 2025
21 Jun 2025
7 Jun 2025
Amount
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water & removal of debris off the premises etc. complete all as specified & directed.
M&L for rendering 15mm thick in CM 1:4 and finished fair and even all as specified and directed by Engr-in-Charge.
M&L Prepration of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified and as directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles complete all as specified & directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified and as directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directd by engr-in-Charge.
M&L for Brickwork with subclass ‘B’ bricks,(Except bricks) straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directd by engr-in-Charge. (Note : Servicable Old bricks obtained from demolition shall be reused after cleaning and washing )
M&L Brickwork with subclass ‘B’ bricks, straight for curved on plan to any radius in half brick thick walls built in CM 1:4 complete with and including joints shall be neatly struck flush with same green mortar as the work proceeds
M & L for Brickwork with subclass ‘B’ bricks, (Except bricks) straight for curved on plan to any radius in half brick thick walls built in CM 1:4 complete with and including joints shall be neatly struck flush with same green mortar as the work proceeds complete all as dirceted. (Note : Servicable Old bricks obtained from demolition shall be reused after cleaning and washing )
M & L Bricks sub class B laid on edge bedded and jointed in CM 1:6 and pointed in cement mortar 1:6 complete with and including joints shall be neatly struck flush with same green mortar as the work proceeds complete all as specified and as directed.
M & L for Plain cement concrete (1:3:6) type C1 (using 20mm graded stone aggregate) as in surface channels etc complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B-1 using (20 mm graded stone aggregate) in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed surfaces embedded in concrete complete all as directed.
Excavating in post holes (or similar holes) in any type of soil each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm ,watering and removing surplus soil to a distance not exceeding 50m and making good surface (soft /loose soil) complete all as directed.
M&L for rolled mild steel section such as angle etc as in post and struts as in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, Flat iron fillets (for securing wiremesh etc ) including all necessary drilling , bolting or riveting etcand similar works conforming to Fe 410-0 or Fe 310-0, ccomplete all as specified and directed
M&L for PCC 1:3:6, type C-1 (20mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as directed
Dismantling fencing wire mesh, any type complete all as directed.
Supply only chain link fencing MS galvanised fencing including lines wires, any mesh, size and type to standards, rails, straining bolts, etc. including provision of binding wire all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete.
S/F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties/tie bars for roof/Chain link including securing bolts complete all as specified and directed
S/F Mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5cm but not exceeding 10 Cm long and dia of shank 11 to 15mm complete all as directed.
Restraining, resecuring including making good staples etc Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured).
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed. (each line wire to be measured) with and including taking down the same complete all as dirceted.
M&L for preparation of newly steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old painted or plastered surfaces of walls etc by washing, rubbing down and applying one coat of cement base paint complete all as specified & directed.
M&L for preparation of old painted or plastered surfaces of walls etc by washing, rubbing down and applying two coats of cement base paint complete all as specified & directed.
M&L for preparation of old painted surfaces of steel of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
M&L for preparation of old plastered / unplastered surfaces of walls and applying two coat of acrylic antifungal exterior emulsion paint over a coat of primer complete all as specified & directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid dry or laid dry and pointed complete all as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removing debris and rubbish out of the premises to a distance beyond 50m and upto a total distance of 250m complete all as specified & directed.
M&L for Hardcore of guage exc 63mm but n exc. 100 mm, using broken stone and boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as directed.
M & L for plain cement concrete (1:4:8), type D-2, (using 40mm graded stone aggregates) foundation filling and mass concrete, sub bsae etc complete all as specified and directed.
M & L for Chequered cement conc tiles cast in rubber moulded glossy finish of approved colour general purpose double layer of size 25cm x 25cm x 22mm thick with mixture of white and grey cement in equal proportions and pigments set and jointed and pointed in neat cement slurry in floor over and including 15mm thick bedding of cement mortar (1:6) complete all as specified and as directed
M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of coarse sand, compacting and proper embedding/ layingof inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as directed.
S&F TMT bar 10mm dia and above cut to length bent to shape required including cranking hooking ends and binding with and including mild steel (annealed) wire not less than 0.9mm dia or securing with clips complete all as directed.
M&L for providing precast reinforced cement concrete (1:2:4) Type B-1 using 20mm graded stone aggregate as in precast cover slab set in cement mortar 1:6 complete all as specified and as directed
Dismantling wrought cast iron or mild steel work of any description not otherwise provided for complete all as directed.
S/F Framed work of rolled mild steel conforming to Fe-290 (GdeE165) as in doors or gates & water tank staging of angle or other section with gusset plates, rails, braces, etc, drilled for fixing of steel sheeting or other covering; doors etc to be prepared for hanging or sliding with and including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting, running rails & guides) and hanging, fastening & fixing complete all as directed,
Taking down steel gates from its position and repair the same including thorughtining alignment properly including welding additional stiffer, brases, pintol hinges locking arrangement etc and erecting the same back in position after applying one coat of synthetic enamel paint in area of gate n.exc 5.00 Sqm each leaf all as directed (Note : Necessary MS sections such as angle, pipe, bars, flats , lathe /bush Pintol hinges shall be finished with necessary greasing and the same shall be be measured and paid seperately by weight )
S/F mild steel best quality lathe machine made floor bushes and pintal hinges for steel gate welded to existing gate complete all as specified and directed by Eng-in-charge. Note:- Any additional Mild steel member welded shall be masured and paid separately
Gravell (BID ID -3331802)
MAA COMMUNICATION (BID ID -3323531)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .