| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.0 CrAccepted-Finance | ₹2.0 Cr | L-1 | Accepted-Finance Being the lowest bidder |
| 2 | L-2₹2.1 Cr+₹12.4 L (6.22%)Rejected-Finance BADRI RAI COMPANY ARUN KUMAR RAI DULIAJAN STATION ROAD P O DULIAJAN P S DULIAJAN DIBRUGARH PIN 786602 | DULIAJAN | DIBRUGARH | ASSAM | 786602 | ₹2.1 Cr+₹12.4 L (6.22%) | L-2 | Rejected-Finance Not being the lowest bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically disqualified |
| 4 | Rejected-Technical NULL | - | - | Rejected-Technical Technically disqualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technically disqualified |
| Sl No | Description | Qty | Unit | M/S Badri Rai & Company L2 | Debashish Goswami L1 |
|---|---|---|---|---|---|
| 1.00Civil and Electical Works | |||||
| 1.01 | Excavating, supplying and filling of local earth (including royalty) by
mechanical transport upto a lead of 5km also including ramming andwatering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. | 75.85 | Cum | 329.15 ₹24,966.03 | 320.43 ₹24,304.62 Lowest |
| 1.02 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). | 30.51 | Cum | 6,244.78 ₹1,90,521.99 | 6,079.29 ₹1,85,473.06 Lowest |
| 1.03 | Dry brick pitching half brick thick in drains including supply of bricks
and preparing the surface complete :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 113.78 | Sqm | 542.15 ₹61,683.12 | 527.78 ₹60,048.17 Lowest |
| 1.04 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu?ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 2.45 | Cum | 9,093.8 ₹22,288.9 | 8,852.81 ₹21,698.24 Lowest |
| 1.05 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural
sources : 6 graded stone aggregate 20 mm nominal size
derived from natural sources) | 116.62 | Cum | 5,713.56 ₹6,66,343.94 Lowest | 5,939.57 ₹6,92,702.35 |
| 1.06 | Centering and shuttering including strutting, propping etc. and removal of form for
Lintels, beams, plinth beams, girders, bressumers and cantilevers | 33.11 | Sqm | 543.17 ₹17,984.36 | 528.78 ₹17,507.91 Lowest |
| 1.07 | Columns, Pillars, Piers, Abutments, Posts and Struts | 22.36 | Sqm | 718 ₹16,054.48 | 699.04 ₹15,630.53 Lowest |
| 1.08 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level
Thermo-Mechanically Treated bars of grade Fe-500D or more | 309.95 | Kg | 80 ₹24,796.16 | 77.92 ₹24,151.46 Lowest |
| 1.09 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron) | 4,043.26 | Kg | 416.33 ₹16,83,330.44 | 405.3 ₹16,38,733.28 Lowest |
Tender Value
₹2.3 Cr
EMD Value
₹4.6 L
Closing Date
8 Sept 2025, 2:00 pmClosed
Superintending Engineer GU
Office of the Superintending Engineer GU
Construction upgradation of Ground floor rooms of Centre for Brahmaputra Studies at Gauhati University
2025_GU_46521_1
T/25-26/132 Date 12.08.2025
Open Tender
Composite Works
Item Rate
90 days
Gauhati University
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
₹4.6 L
Yes
Office of the Superintending Engineer GU
2 Jun 2026
14 Aug 2025
8 Sept 2025
14 Aug 2025
8 Sept 2025
14 Aug 2025
1 Sept 2025
Amount
Civil and Electical Works
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming andwatering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu?ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Powder coated minimum thickness 50 micron aluminium
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board
12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Size of Tile 800 x 800 mm
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size)
Cement mortar 1:3 (1 cement : 3 coarse sand)
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
Supplying fitting fixing 35mm thick both side laminated Century flush door Shutter with Natural Anodised Aluminium Door Frame of Hindalco Extruded Section SP-4343 size 108mmx53mmx2mm with door fittings Godrej make, complete with all lobour and material Single Door shutter without vision panel
Double Door shutter without vision Panel
Supply, fitting , fixing of aluminium section profile - natural anodized (SK-100) - 100mm skirting of 3.0 meter per piece length with PVC beading and plastic end caps
Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
2 x 4 sq. mm + 1 x 4 sq. mm earth wire
2 x 6 sq. mm + 1 x 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
3 x 6 sq. mm
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Group B
Group C
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
15/16 A switch
3 pin 5/6 amps socket outlet
6 pin 15/16 A socket outlet
Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm)
6 Module (200mmX75mm)
4 Module (125mmX75mm)
3 Module (100mmX75mm)
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature cirtuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. As required. Single pole
Single pole and neutral
Triple pole and neutral
Supply , fittin, fixing of AC ceiling fan of having 1200mm sweep with complete accesorise & connection. Orient make or Equivalent.
Supply and installation of new LED slim aluminium recessed panel light-round complete with all accessories.
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 2 TR
Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeedmotor, coil sectio withDX copper coil, electronic expansion valve, corded remote control,outercabinet,vibrationisolators,drainpan,othernecessary supportsetc.,suitableforoperationonsinglephaseACsupply230V ±10%, 50Hzcompleteas required. Theunit shall haveautomatic orceshutdownprovisionincaseof fireonreceiveingsignal from BMSSystem. Thecoolingcapacityof indoorunitwillbeatair inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Low static ductable units (minimum 25 pascal external static pressure) 1.3 TR
Supply, Installation, testing and commissioning including vaccumiazationandNitrogentestingof followingnominal sizesof soft/hard drawn copper refrigerant piping for VRV/VRF system, completewith fittings, with suitable adjustable ring typehanger supports, jointing/brazingincludingaccessories, insulatedwithXPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrilerubbertubularsleevessectionsofspecifiedthicknessasgiven below for Suction and Liquid lines, all accessories as per specifications etc. as required : 15.86mmdia(OD) (Softdrawn)with tubethickness1.2mmwith19 mm thick insulation
19mmdia(OD)(Harddrawn)with tubethickness1.2mmwith19mm thick insulation
25.4mmdia(OD) (Harddrawn)with tubethickness1.2mmwith19 mm thick insulation
28.58mmdia(OD)(Harddrawn)with tubethickness1.2mmwith19 mm thick insulation
31.8mmdia(OD)(Harddrawn)with tubethickness1.62mmwith19 mm thick insulation
M/S Badri Rai & Company (BID ID -279542)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
cancelled_1.pdf
pdf • 0.32 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .