Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹40.5 L
EMD Value
₹80,970
Closing Date
6 Jan 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2025_PWDJK_299173_1
e-NIT No.EDJ/167 of 2025-2026 Dated 26-12-2025
Open Tender
Electrical Works
Percentage
Billawar
please refer to NIT
2 documents required · 2 mandatory
₹600
Executive Engineer PWD RandB Electric Div Jammu
₹80,970
24 Jan 2026
26 Dec 2025
7 Jan 2026
27 Dec 2025
6 Jan 2026
27 Dec 2025
Supply, Installation , Testing and commissioning of 12-18 Watt Mono linear outdoor type spike light with weather proof/ water tight junction box for connections (to be fitted with the help of iron fastner as required at site) made of aluminium extrusion, LED Make : CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG , Rated input supply of Input Voltage 24V DC, Luminaire luminous flux Minimum range 600-800 Lm. IP protection rating : IP65 or higher. The luminaire should have nerrow beam angle (as per site requirement). Job includes all civil work for installation of lights at desired location with the help to frame/angle/nut bolts/Iron Galvanized Razor Blade Wire for monkey meance as directed by Engineer-in-charge. Manufectures word Mark/ Name Engraved/ Embossing / Screen Prionting on die cast housing to allw traceability/ authenticity. (LM70/LM80) certificate/report with liable warranty of product/accessories from OEM shall be submitted.. The Minimum warranty shall be for 2 years. .Job includes all civil work for installation of lights at desired location with the help to frame/angle/nut bolts/Iron Galvanized Razor Blade Wire for monkey meance as directed by Engineer-in-charge Make Philips, Havells, Wipro, LT or Equivalent.
Supply, installation, testing and Commissioning of AC 220V input, DMX 512 , main controller system support minimum 1000 points in offline, support-switch parallel supply, SD card storage, J preset maximum 255 program files, main stream - 32/64 bit power usage -15 watt, sotomatic, regular, present program play. Complete with splitter, decoder etc. as required. Addressing Kit shall automatically write address to a whole group of interconnecting luminaires within minutes. It shall be Miniature industrial design, compact size and touch screen. It can be powered by a power bank with a Micro-B type USB port for on-site programming and testing after installation. The housing shall be extruded Aluminum with black finish weighing approx. 0.2Kg with temperature range -10°C to 40°C, input voltage of 6-24V DC and humidity range of 10 to 90% (no condensation). The product shall be compact in size, compatible with multiple types DMX 512 chips, with Built-in test animation effects, SD card slot to store animation and scenes. The addressing kit shall support standard RDM protocol, searching for RDM luminaires and static detection, Color-pick functions, and can be powered by Micro-B type USB power supply including programming complete in all respect for successful completion .
Supply, installation, testing and commissioning of 10KVA Servo Motor controlled oil colled Automatic Voltage Stabilizer to operate on single Phase load (Transformer oil to be cooling medium and shall be ISI marked IS-335 with latest amendments) and suitable to operate on unbalanced input Single phase voltage of 90 -270volts and delivering voltage of 230 ± 1 %, single Phase, 50 Hz ± 3 % AC power supply. The stabilizer shall be copper wound in sheet steel case, duly painted and filled with transformer oil. The voltage stabilizer provided with single phase, 100 Amp Aluminium bus bar, MCCB DP 100 Amp and on load change over switch 63/100 Amp 2P required during by passing the voltage stabilizer.
Supply, installation, testing and commissioning of Multicolor (100watt) LED RGBW floodlighting luminaire for façade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9, fixture shall be suitable to operate at an ambient temperature range of 10 ºC t + 50 ºC and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50 ºC . Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.
SITC of high quality long through multi color 12W RGBW Spot light light, Protection Rating : IP66 or Higher, complying to BIS standard "IS 10322 (Part 5/Sec 1): 2012" and having CE certification against standard "Low Voltage Directive & Protective Equipment - EN 60598-1:2015", and "Electromagnetic Compatibility Directive - EN 61547: 2009", Mounting Structure : Adjustable surface mount yoke arrangements for fixing the lights. LED fixture with 5050 LED of system lumens 1100lm, Power Consumption: 12W, CCT : RGBW(3000-7000K) as per the design approval, CRI for white : >80, SDCM <3, Optics : PMMA with holder, Beam Angle : 25º/45º/60º, Control : DmX512 Channel : 4 CH, Body : Die casted / extruded aluminium with embossed manufacturer logo, Separate compartment for keeping the decoder/driver in the housing which can be easily removable for service without disturbing the LEDs/Optics, Hot spot and light distribution : Optics Designed to minimize hot spots & fringing in color mixing applications. Power Input : Constant DC 24V with external driver to the constant current decoder, Surge Protection : Inbuilt surge protection in the driver 2KV-4KV(Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection: IK08 or higher, Painting : Chemical 3/7 tank processed treatment before the powder coat black/ash/approved color coat. Fixture will be suitable to operate in a temperature range of -10°C to +60°C, The light fixtures should have IP68 air vent made up of brass/stainless steel which helps to desiccate & prevent from forming moisture inside the light fixture at worst environmental condition. LED life should be at least 60,000 burning hours at L70 at 55 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 70 micron Copper, 2W TC with Black or White masking, Copper/OSP finish. LM79, IK08, IP66, Surge, Endurance and Thermal test from NABL Accredited laboratory. LED Makes should be CREE, LumilLED, Osram, Seoul, Nichia or equivalent with the engineer or 3rd party testing laboratory approval. Power & DMX Loop In/Out along with IP68 connector having the length >300mm. BIS, CE & RoHS Certificates along with tender documents, Fixture body color has to match with Building color.
Supply installation testing and commissioning of 15W, IP65 Decorative bollard with System efficacy of 70 lm/W, with PC Diffuser. LED bollard Light shall be made up of Die cast Aluminium Housing for better heat decapitation, height of bollard should not be more than 1000 mm. L70 life of 50000 Hrs. P.F.>0.90 with THD<25% ,CCT 3000 K, CRI 70,Surge Protection 2 Kv. Input voltage range of 180V to 270V. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab the sample should approved by Engineer-in-charge.
Supply, Installation , Testing and commissioning of IP67 power supply 24V output anlog with its enclosures Power consumption- 200W
Supply, Installation , Testing and commissioning of IP66 box enclosure for power supply.
Supply/Installation/Testing & Commissioning of heritage architectural ornamental decorative cast iron pole . Installation of same with foundation bolts of suitable size to grout it into specially designed RCC foundation, as shown in the enclosed drawing. The decorative light fixture shall be fixed on the top of the pole. The details of pole, & light are given below: - The Pole: The pole shall look like as shown in the drawing. It shall have all similar features as shown in the enclosed drawing/picture. The Cast Iron Pole of 3 Mtr (3000mm) length. The pole has ornamental base (Approx. overall dimension-height 1050mm,bottom dia 370mm) shall have a provision of inbuilt junction box for fixing MCB’s or cutouts with detachable window cover. The part above ornamental base design consists of decorative sections of circular shapes & collar in different dimension, is made of cast iron in fine finish. The design of the cast-iron parts is clearly shown in the drawing. Mentioned dimensions are proposed dimensions, which may vary with actual measurements (Tolerance of ±5%)
Heritage architectural ornamental decorative cast iron pole confirming from CAT-Code VHP-801 &with top post lamP 50 watt having lifetime of 50000 BH (Shall be approved by Department before Supplying) of Dwarka/Karara Mujasame/Hi-Lite Make.
Providing of reinforce cement concrete foundation as per above specifications/enclosed drawing including foundation nuts & bolts of required size welded together firmly with reinforcement properly
Providing service connection to be carried from pole junction box to luminaries using 3x1.5 Sq.mm FR-LSH multistrend copper wire confirming IS 694 ammended upto date of Polycab/Microtek/RR-Cable/Anchor Make.
Supply/Fixing/Testing and Commissioning of 6 Amp to 10 Amp Rating ,240v,*C* Curve 10K,SP Miniature Circuit Breaker suitable for inductive load and to be fitted in existing poles Complete with connections includes its thimbling (L&T/Microtek/Siemens/Legrand/ABB /Schneider Make)
Supply/Fixing of 63 Amp 4-Way(TPN)Joint connector Terminal Block of standard make including Tubular/Reducer/Bottle type terminal thimbles/Lugs of dowel/JV 14 Make with its crimping and tapping of required color Complete Job
SITC of Spike Earthing through GI Rod Electrode of 1.5 mtr length (Complete Job)
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.
Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable)
16 sq. mm 4 core
35 sq. mm 2 core
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required
40 mm dia
63 mm dia
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required (Group-A)
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire
2 x 2.5 sq mm + 1 x 2.5 sq. mm earth wire
2 x 4 sq. mm + 1 x 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 x 10 sq. mm + 2 x 6 sq. mm earth wire
4 x 16 sq. mm + 2 x 6 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mm x 75mm)
3 Module (100mm x 75mm)
4 Module (125mm x 75mm)
6 Module (200mm x 75mm)
8 Module (125mm x125mm)
12 Module ( 200mm x 150mm)
Supplying and fixing of following rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole upto 32 amp.
Single pole and neutral 40 Amp
Single pole and neutral 63 Amp
TPN 40 Amp
TPN 63 Amp
Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.
380mm/15" Heavy duty
450 mm/18" Heavy duty
Supplying and fixing of ceiling fan of followingsweep with 2.25 mfd condenser and 1'-6" down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. (As approved site in-charge)
1200 mm sweep (3 Star)
Supplying and fixing of 400 mm sweep wall mounting fan (oscillating type) on wall with necessary connection as required.
Supplying, installation, Testing & Commissioning of 18 watt LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)
Supplying, installation, Testing & Commissioning of 18- 22 watt LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)
Providing cement concrete foundation including excavation for the poles (45 cm x 45 cm x 75 cm) in 1:3:6 mix (1 cement : coarse sand : stone aggregate 25 mm size) duly plastered and finishing in an approved manner with necessary curing. Job includes grouting of 4 Nos. 20mm dia 200 mm long J-type foundation bolts and errection of pre-fabricated street light pole on these bolts and tightening with nuts as required.
Supply and Installation of integrated All-in-One Solar LED Street light luminaire consisting of solar panel, battery, PIR Sensor and charger built into the luminaire, with minimum system lumen output of 5000 lumens. System efficacy should be ≥180lm/W. Wattage of luminaire should not exceed 30 W. Luminaire should have minimum panel capacity of 30-40 Wp Mono and LiFe Po4 battery capacity of minimum 12.8V 18AH. AIO luminaire should be with PIR sensor with suitable dimming profile to ensure autonomy of 2nights. The luminaire shall have a specially designed pole mounting piece that enables lateral as well as post top mounting and installation. Luminaire should be IP65 protected, IK 08 impact resistance certified with corrosion proof extruded aluminum housing. LiFePO4 battery should be of minimum 2000 cycle life class. Panel type: Mono Crystalline Panel with solar module efficiency≥17% for faster charging. Charge controller should be MPPT type, dusk to dawn operation. LM80 and LM79 report from 3rd party NABL accredited lab must be submitted along with the bid. The product shall comply to IEC60598-2-3 for Safety of Luminaire for Road and Street Lighting, IEC 62109-1 for Safety of Power Converters used in solar Panel Equipment, IEC 62133 & UL1642 for Safety of Lithium Ferro Phosphate Battery and IEC 61730-1,2 & IEC 61215 for Safety of Solar Panel Module. (Make:- Havells/Wipro/Anchor Panasonic/Philips)
Supplying, Fabricating, erecting & fixing of medium class G.I pipe 75 mm in diameter 3000 mm long in poistion for street light having MS base plate of size 450 mm x 450mm x 8mm thick duly welded to the bottom alongwith J-Bolts 300mm long
Supply, Installation , Testing and commissioning of LED projector light fixture 50-60W, LED, MONO, IP 66. The housing should be made of high strength pressure die cast aluminium with 3-4mm thick safety glass and coated by static powder making it weather resistant. Protection screen with tempered glass with high impact resistance IK07. Voltage input AC240V . The luminaire should have options for various beam angle: 10°/25°/50°/60°. Estimated LED Lifetime is L70-100,000 hours minimum@ 25degree Ambient Temperature and LEDs of CREE / OSRAM / NICHIA to be used. Minimum Light fixture Lumen output atleast 3000 Lumens. Operating Temperature : - 20°C to +50°C. Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements.Job includes all civil work for installation of lights at desired location with the help to frame/angle/nut bolts for monkey meance as directed by Engineer-in-charge. Manufectures word Mark/ Name Engraved/ Embossing / Screen Prionting on die cast housing to allw traceability/ authenticity. (LM70/LM80) certificate/report with liable warranty of product/accessories from OEM shall be submitted.. The Minimum warranty shall be for 2 years. .Job includes all civil work for installation of lights at desired location with the help to frame/angle/nut bolts/Iron Galvanized Razor Blade Wire for monkey meance as directed by Engineer-in-charge. Make Philips, Havells, Wipro, L&T or Equivalent.
Supply and fixing of 09 mtr height steel tubular pole 410-SP, steel should be of good quality, the base plate duly welded at bottom of Pole . The mast shall have 4 nos 32 mm dia hole at 2-2.5 meter above to base plate suitable to accommodate 2 to 4 nos of 2.5 sqmm 3 core copper cable from control panel to Luminaries. The adustable ring duly welded between inner periphery of ring and pole cap of steel pipe which is provided with sufficient holes to hold LED flood light . The cap of the ring shall have 4 nos holes welded suitably with 4 nos nuts to facilitate tightening of the ring on the top of the Mast. Painting of 11mtr height pole with coat of primer and 2 coats of silver paint.
Erection of 9 mtr height metalic pole in cement concrete 1:3:6 stone aggregate 40mm nominal size foundation including excavation and refilling etc as required.
Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge. Double arm overhang
Supplying, installation, Testing & Commissioning of 90 watt Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
CAMC for 4 years after Defect liability period of 1 year
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.65 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.53 MB
BOQ_970475.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .