Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹41.5 L+₹9.4 L (29.4%)Rejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Not Being L1 |
Tender Value
₹35.2 L
EMD Value
₹70,400
Closing Date
17 Sept 2024, 6:00 pmClosed
GE CENTRAL BANGALORE
ASC CENTRE AND COLLEGE AGRAM POST BANGALORE 560007
REPAIR MAINT OF CI DI GI PIPE LINES BOREWELL UG SUMP CLEANING PUMP MOTOR REPLACEMENT OF BLOWER MOTORS PANEL MCCBs CABLE AND CONNECTED ITEMS AT 300 KLD STP NEAR 5 No GATE UNDER GE CENTRAL BANGLORE
2024_MES_666821_1
8398E
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE CENTRAL BANGALORE
Pl refer tender documents
6 documents required · 6 mandatory
₹500
GE CENTRAL BANGALORE
₹70,400
Yes
24 Oct 2024
19 Jul 2024
19 Sept 2024
19 Jul 2024
17 Sept 2024
29 Jul 2024
19 Jul 2024 - 27 Jul 2024
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation , laying of pipe line etc and getting out in Soft / loose soil complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
M & L for PCC 1:4:8, type D2 using 40 mm graded crushed stone aggregate as in foundation filling mass concrete complete all as specified and directed
Taking down old 20 mm bore GI tubing and connection including cleaning for re-fixing stacking at site where directed complete all as directed.
All same as per item No 5 here-in-above but 25 mm bore of pipe.
All same as per item No 5 here-in-above but 40 mm bore of pipe.
All same as per item No 5 here-in-above but 50 mm bore of pipe.
Laying only 20 mm bore GI tube medium grade with all fittings all new (ISI Marked) laid in trenches / fixed to wall and ceiling or laid in floors making necessary connection and testing complete all as directed.
All same as per item No 9 here-in-above but 25 mm bore of pipe.
All same as per item No 9 here-in-above but 40 mm bore of pipe.
All same as per item No 9 here-in-above but 50 mm bore of pipe. (Note : for item No 9 to 12 : Servicable GI Pipes obtained from item No 05 to 08 here -in - above).
M & L for 20 mm bore GI tubing medium grade (ISI marked) with fittings all new (ISI marked) fixed to wall and ceiling or laid in floors complete all as directed.
All as per item No 13 here -in - above but 25 mm bore of pipe.
All as per item No 13 here -in - above but 40 mm bore of pipe.
All same as per item No 13 here-in-above but 50 mm bore of pipe.
Repair the existing 20 mm bore defective GI pipe in trenches / on roof / on wall and relay the pipe line after repair to leaked joints of pipe line complete including replacement of GI fitting i.e union,nipple & sockets and refixing in position in trenches & all as directed.
All as per item No 17 here -in - above but 25 mm bore of pipe.
All as per item No 17 here -in - above but 40 mm bore of pipe.
All same as per item No17 here-in-above but 50 mm bore of pipe.
M & L for attending water supply complaints such as water leakage from CI/DI /GI pipe line of 25 mm to 200 mm dia pipe carefully after discon-nection of joints to a length up to 8 mtr and create bund with excavated earth and dewatering / bailing out water complete with diesel engine driven pump set and positioning the pipe line after repairs in civil and defence areas and various locations by exavating in any type of soil, check the nature of defects for leakages and rectification work to be carried out by replacing requisite materials, testing complete on completion of work & then returning filling the soil including disposal of surplus soil if any as directed by Engr-in-Charge. Note : (i) CI/DI/GI pipe of size 25 mm to 200 mm and necessary fittings required for rectification of work will be measured and paid under relevant items. (ii) Necessary permission from civil authorities, local bodies and liaison with these authorities should be considered prior to execution of work (iii) Necessary excavation & earthwork ,Bailing out of water by pumping set ,necessary barricade, diversion boards and necessary safety sings, procedures to be adopted wherever work is in progress without any extra cost.(iv) The breakdown shall be attended within 4 Hrs of intimation round the clock and time of restoration shall be maximum of 8 Hours. The additional manpower required to complete the job shall be provided by the contractor without any extra cost to Govt.
Taking up old unserviceable sluice valve cast iron body of 80 mm bore size and M&L for cast iron Sluice valve class PN 1.6, 80mm bore with flanged ends, drilled, brass spindle, gun metal nut, operating wheel complete all as per IS 14846-2000 with ISI mark and fixed in position with rubber gasket joints, bolts nuts and washers etc all as specified and as directed.
All as per item No. 22 here-in-above but for 100 mm bore
All as per item No. 22 here-in-above but for 150 mm bore
All as per item No. 22 here-in-above but for 200 mm bore
Taking up old unserviceable sluice valve80 mm dia spindle made out of PN-6 steel with check nut made out of brass/bronze material including replacing perished gland packing, rubber gasket, bolts and suitable size of nuts complate all as directed :-
All as per item No. 26 here-in-above but for 100 mm bore
All as per item No. 26 here-in-above but for 150 mm bore
All as per item No. 26 here-in-above but for 200 mm bore
S&F in repair 20 mm dia. Cast copper alloy Stop valves, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as directed..
S&F in repairs gun-metal, globe or gate valve, with crutch or butterfly handle, screwed both ends for iron pipe 15 mm bore complete all as specified. Make: Leader/ Zoloto/L&T (AUDCO)
All as per item No.31 here in above but for 20 mm bore
All as per item No. 31 here in above but for 25 mm bore
All as per item No. 31 here in above but for 40 mm bore
All as per item No. 31 here in above but for 50 mm bore
M&L for fixing in repair Y type Dirt box (strainer) made out of CI with necessary washout arrangement complete including necessary additions & alterations to 150 mm dia pipe incl cutting, gaskets & GI nut bolts & washers etc complete of following sizes:- Note:- (i) CI/MS pipe/ Specials if required will be measured & paid separately.(ii) Quoted rate is deemed to be inclusive of cutting , gaskets , nuts & bolts etc).
All as per item No. 36 here-in-above but for 100 mm bore
Supply and fixing in repair Rubber gasket joint suitable for 150 mm bore cast iron/DI pipes all as specified and directed.
Supply and fixing in repair Rubber gasket joint suitable for 80 mm bore cast iron/DI pipes all as specified and directed.
S&F in repair Cl swing check NRV conforming to IS-5312, sutiable for 100 mm bore pipe consisting Cast iron Body, door as per IS 210, Bronze body ring as per IS 318, natural rubber door face, hinge pin SS ASTM A276 type 410, fasteners as per IS 1367, Natural rubber gasket, etc complete double end flanged and drilled, of Class PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed.
S&F in repair Cl swing check NRV conforming to IS-5312, sutiable for 80 mm bore pipe consisting Cast iron Body, door as per IS 210, Bronze body ring as per IS 318, natural rubber door face, hinge pin SS ASTM A276 type 410, fasteners as per IS 1367, Natural rubber gasket, etc complete double end flanged and drilled, of Class PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed.
M&L for rectification of existing defective run lead joints including burning and removing the old defective lead joints from 80 mm bore CI/DI pipes and providing new lead joints with all required materials and testing the joints for leakages complete all as directed (Note:Earth work shall be measured separately)
All as per item No. 42 here-in-above but for 100 mm bore
All as per item No. 42 here-in-above but for 150 mm bore
All as per item No. 42 here-in-above but for 200 mm bore
Taking down wornout /rusted cast iron pipe any dia laid in trenches & Supply, laying new cast iron pipes 80 mm bore with spigot and socket ends centrifugally cast, Class LA ISI marked in any length suitable forlead joints, laid in trenches making necessary connection and testing on completion complete all as specified & as directed. (Note : i) CI Iron Specials measured & paid seperately ii) Excavation & earthwork , lead joints shall be measured and paid separately under relevant items).
All as per item No.46 here-in-above but for 100 mm bore
All as per item No. 46 here-in-above but for 150 mm bore
All as per item No. 46 here-in-above but for 200 mm bore
M & L for Cast Iron specials such as bends any type radius and angle, tapers any type straight, increasing, decreasing or double socket etc, tee pieces, single branch, ‘Y’ junction, double branch, cross, collars, cps and plugs etc as required at site for jointing any dia of pipe upto 200 mm bore CI spigot & socket pipe complete all as specified and directed.
S&F in repair for Butterfly valve, non-rising type conforming to IS-14846 -2000, sutiable for 100 mm bore pipe consisting of SS spindle as per IS 6603, Cast iron Body, Dome & Wedge as per IS 210, greasy jute type gland packing, fasteners as per IS 1367, Natural rubber gasket, CI manual hand wheel etc complete double end flanged and drilled, of Class PN-1.0 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed. Make : Kirloskar / Venus / Shakti / Upadhyaya
All as per item No. 55 here-in-above but for 80 mm bore
Supply & Fix in repair of cast iron foot valve 100 mm dia complete with necessary bolts, nuts, washers all as directed.
Supply & Fix in repair of cast iron foot valve 80 mm dia complete with necessary bolts, nuts, washers all as directed.
Supply & Fix in repair of cast iron foot valve 50 mm dia complete with necessary bolts, nuts, washers all as directed.
Disconnecting / Removing existing unservicable / defctive scale type water level indicator and S&F new dial type water level indicator suitable for Over Head Storage tank of height 15 m to 21 m staging as per existing make or as approved by GE complete with central movement plate, counter weight, centre dividing wheels, MS/CRCA enclosure, float and connecting control wire system from tank to indicator etc complete grouted in PCC all as directed including testing and commissioning all as directed.
Demolition of damaged valve chamber and Construction of new valve chamber of size 1200x1200x900mm internal dimension including necessary earth work excavation with earth work on any type of soil, PCC 1:3:6, type C2 as in foundation, brick work in CM 1:4, 15 mm thick plaster in CM 1:4 internally and externally, flush pointed in same mortar as work proceeds, 75 mm thick PCC coping all round PCC 1:2:4 tyype B1 (using 20 mm aggregate), flooring shall be 40 mm thick PCC 1:2:4 type B1 (using 20mm aggregate) laid over 75 mm thick hard core. Top cover shall be made out of MS sheet 3.00 mm thick fixed in angle iron frame made out of angle iron size 40x40x6 mm with two number of hinges on one side and locking arrangement at other side complete including painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
All as per item No. 57 here-in-above but of internal size 1000x1000x1050 mm -do-
All as per item No. 57 here-in-above but of internal size 900x900x1050 mm -do-
M & L for dismantling of motor of 20 HP to 30 HP capacities pumpset from installed position in any area as ordered after disconnecting the coupling and electric connections and transporting the motor to the work shop, strip opening of the motor complete incl dismanlting stator, rotor assembly and cleaning the complete assemblies by taking out perished glass sleeve of connecting leads from common termination to terminal block,and washing with carbon tetra chloride, decarbonising and cleaning the rotor with CTC solution.Replacing the glass sleeve of connecting leads from common termination to terminal block, binding the loose coils with binding cloth, varnishing the coils complete and applyng bectol on the excitor coils, stator coils and heating complete, reassembling the unit and testing with megger for insualtion value and re-assembling, aligning with pump, re-inserting shims where necessary, refixing with coupling, tightening with torque wrench to required level, complet painting of motor /pump re-connecting the electric cable etc and check for drawing current testing, commissioning etc all as directed by Engineer-in-Charge.
All same as per item No 60 here-in-above but motor 10 HP to 15 HP capacities -do-
All same as per item No 60 here-in-above but motor 5 HP to 7.5 HP -do-
M & L for dismantling the pump of 20 HP to 30 HP capacity, checking the worn out parts like impeller, shaft, stuffing box, shaft sleeve using Micrometer and transporting to workshop for repairs, check for condition of bearings, removing scales from impeller and pump housing, building the worn out metal of transmission shaft to required level, machining to the required size on lathe machine, grinding and finishing to match the sleeve, and fixing into the housing, re-assembling, transport back to the installation, installing in position, check for alignment with dial gauge, inserting shims where necessary, refixing with coupling, tightening with torque wrench to required level, re-connecting the flanged pipe connections of suction/ delivery including replacement of rubber insertion, complet painting of motor /pump etc complete, all as directed by Engineer-in-Charge.NOTE :- Spares will be measured and paid separately under relevant schedule.
All same as per item No 63 here-in-above but motor 10 HP to 15 HP capacities -do-
All same as per item No 63 here-in-above but motor 5 HP to 7.5 HP -do-
Supply only for incorporating of pumpset repair work in relevant Schedule 'A' Item No 63 for pumpset of capacity 20 to 30 HP :- (i) Shaft bushes with check nuts (stainless steel) for above pumpset.
(ii) Ball bearings suitable for above pump. Make : NBC / SKF.
(iii) Metal Coupling for above pumpset.
(iv) Gland packing end cover (Stainless steel of suitable grade) as per existing size
(v) star rubber Coupling for above pumpset.
Supply only for incorporating of pumpset repair work in relevant Schedule 'A' Item No 64 for pumpset of capacity 10 to 15 HP :- (i) Shaft bushes with check nuts (stainless steel) for above pumpset.
(ii) Ball bearings suitable for above pump. Make : NBC / SKF.
(iii) Metal Coupling for above pumpset.
(iv) Gland packing end cover (Stainless steel of suitable grade) as per existing size
(v) star rubber Coupling for above pumpset.
Supply only for incorporating of pumpset repair work in relevant Schedule 'A' Item No 65 for pumpset of capacity 5 to 7.5 HP :- (i) Shaft bushes with check nuts (stainless steel) for above pumpset.
(ii) Ball bearings suitable for above pump. Make : NBC / SKF.
(iii) Metal Coupling for above pumpset.
(iiv) Gland packing end cover (Stainless steel of suitable grade) as per existing size
(v) star rubber Coupling for above pumpset.
M&L for dismantling the defective induction motor of any capacity/make/class of insulation from foundation bed, duly coupled with pump/compressor, trasnporting to workshop removing burnt out winding from stator/rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing DE /NDE bearings, insulation materials, varnishing , heating, complet painting of motor etc complete, re-assembling, testing and commissioning of 20 HP to 30 HP capacity motors all as directed.
All same as per item No 81 here-in-above but 10 HP to 15 HP
All same as per item No 81 here-in-above but 5 HP to 7.5 HP
Renewal of rubber bush coupling for 20 HP to 30 HP capacities of pumpsets complete all as directed.
All same as per item No 84 here-in-above 10 HP to 15 HP
All same as per item No 84 here-in-above 5 HP to 7.5 HP
S&F in replacement fully automatic star delta motor starter with Spp with metel encloser suitable for 20 to 30 HP motor and .Fabricate, install and testing in replacement factory made, pole mounted canopy headed single door outdoor type, weather proof totally enclosed controlling panel of site suitable size suitable for 3 phase 4 wire 440 volts made out of 3 mm thick CRCA sheet, cubical type, powder coated paint inside and outside, having front hinged door with neoprene rubber gasket including danger notice board/plate earth terminal point, bottom detachable gland plate with holes for incomming and outgoing cables provision fixing arrangement with clamps made out of Mild Steel flat iron 40X5mm including bolts & nuts, Make:-GE / BCH /SIEMENS L&T / C&S / GE/ BCH
S&F in replacement fully automatic star delta motor starter with Spp with metel encloser suitable for 10 to 20 HP motor and .Fabricate, install and testing in replacement factory made, pole mounted canopy headed single door outdoor type, weather proof totally enclosed controlling panel of size 55cm x 50cm x 40cm suitable for 3 phase 4 wire 440 volts made out of 3 mm thick CRCA sheet, cubical type, powder coated paint inside and outside, having front hinged door with neoprene rubber gasket including danger notice board/plate earth terminal point, bottom detachable gland plate with holes for incomming and outgoing cables provision fixing arrangement with clamps made out of Mild Steel flat iron 40X5mm including bolts & nuts, Make:-GE / BCH /SIEMENS L&T / C&S / GE/ BCH
S&F in replacement fully automatic star delta motor starter with Spp with metel encloser suitable for 5 to 10 HP motor and .Fabricate, install and testing in replacement factory made, pole mounted canopy headed single door outdoor type, weather proof totally enclosed controlling panel of size 55cm x 50cm x 40cm suitable for 3 phase 4 wire 440 volts made out of 3 mm thick CRCA sheet, cubical type, powder coated paint inside and outside, having front hinged door with neoprene rubber gasket including danger notice board/plate earth terminal point, bottom detachable gland plate with holes for incomming and outgoing cables provision fixing arrangement with clamps made out of Mild Steel flat iron 40X5mm including bolts & nuts, Make:-GE / BCH /SIEMENS L&T / C&S / GE/ BCH
S&F in replacement fully automatic star delta motor starter with Spp with metel encloser suitable for 20 to 30 HP motor
S&F in replacement fully automatic star delta motor starter with spp with metel encloser suitable for 10 to 15 HP motor . Make:-GE / BCH /SIEMENS L&T / C&S / GE/ BCH
S&F in replacement fully automatic star delta motor starter with Spp with metel encloser suitable for 5 to 7.5 HP motor . Make:-GE / BCH /SIEMENS L&T / C&S / GE/ BCH
S&F in replacement fully DOL motor starter with Spp with metel encloser suitable for 5 to 7.5 HP motor . Make:-GE / BCH /SIEMENS/ L&T / C&S / GE/ BCH
Servicing/Repair of Star delta starter of any capciity/make including checking the all electrical connections ,fuse, SPP,relays,contactor etc .Note: The quotated rate shall be included the all items exacept Conactor and OLT.
Supply and replace power contactor of type ML-2 /MNX equivalent of L&T make or GE complete all as directed.
S&F in replacement Direct-on -line motor starter, type MK1 of L&T make or equivalent in C&S/ BCH/ GE.
Supply and fix in replacement Thermal overload relay of range 45-75A. Make:- GE/SIEMENS/L&T/ABB/JVS/AVIAVA
Supply and fix in replacement Thermal overload relay of range 66-110A. Make:- GE/SIEMENS/L&T/ABB/JVS/AVIAVA
Supply and replace pressure gauge 0-10 kg/cm² ,4" dia internal glycerin filled including stop cock etc complete with necessary fittings incl disamntling old one all as directed. Make:- H-GURU /FIE BIG
Supply and replace pressure gauge 0-50 kg/cm² ,4" dia internal glycerin filled including stop cock etc complete with necessary fittings incl disamntling old one all as directed. Make:- H-GURU /FIE BIG
Dismantling rusted/defective LT panel doors/canopy and M&L for new LT panel doors of size all as per existing with 2 mm / 3.15 mm thickness MS sheet, hinges, locking arrangement etc complete including replacement of neoprene gasket and painting with a coat of of red oxide primer complete all as directed by Engr-in-Charge
M&L for seven stage cleaning and sterilization of inside the RCC/ Steel Underground/semi underground/Over head/Sedmentation/clear water sumps of capacity over head water tank reservoir 100000 gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make: rays Cleantech/ Inus watertech/ satya enterprise.Location : 531 ORs,Seven stages are as under plants:- (a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b). Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical of the company ans scrubbing the walls of the tanks. (c). Third strage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified brannded halogen compound. (e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tnk and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65/Inoxi-60/NB-69 . NOTE:-(i) COMPANY WILL SUBMIT GOVERNMENT LABORATORY TEST CERTIFICATE OF TERBAC-G5/INCHOR-5/NB-10, TERBAC-G65/ INOXIi-60/NB-69, BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE.) (ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID.ENTERING SCALS AND THE SAME SHELL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE ROVISION . (III) STERILIZATION TEAM WILL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM 03 MONTS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. (IV) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE. NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE TO BE INCLUDED IN QUOTED RATE. NOTE:-THE WORK SHALL BE CARRIED THROUGH SPECILIZED AGENCY RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE.
All as per item No.106 here-in-above but Above 200000 gallons capacity over head water tank reservoir at ASC(C&C) P/H.2 & 598 ORs
All as per item No.103 here-in-above but Above 1.0 Lakhs gallons to 2.0 Lakh gallon capacity semi under ground sump at 598 ORs
All as per item No.103 here-in-above but Above 50000 gallons capacity semi under ground sump reservoir at ASC(C&C) P/H.2 & New Dairy Farm
Material and labour for cleaning of semi under ground sump reservoir of capacity 30000 gallons at ASC(C&C) P/H.1,100 Map & 531 ORs by pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositing and levelling as directed and cleaning the tank with the bleaching powder and wire brush after scrapping the walls and bottom of the sump completely without disturbing the water supply to the area including painting the details of sump capacity, date of cleaning and due date of cleaning on the sump wall and applying one coat of white wash to entire sump internally complete all as directed by Engineer-in-Charge.
All as per item No.106 here-in-above but Above 10000 gallon to 25000 gallon capacity semi under ground sump at ASC Butchery,Meerut block,70 Major,Jco mess PH,Bariley block & Kakul block
All as per item No.106 here-in-above but Above 10000 gallons capacity over head water tank reservoir at EME Wksp
supply and filling chlorination chemical highly efficient (high strength) calcium based granular (65-80% chlorine contect) disinfectant complete all as specified and directed by Engr-in-charge.
Supply,install and testing of water meter suitable for 200 mm bore pipe conforming to relevant IS alongwith stainer and connecting pieces,jointing materials etc and connecting to water mains including cutting/grinding of existing water mains as per site requirement for insertion of water meter including taking down old unserviceable water meter complete all as specified and directed by Engr-in-charge. Make : Woltman/Dasmesh/Kranti/Kaycee/Kirloskar.
Supply,install and testing of water meter suitable for 100 mm bore pipe conforming to relevant IS alongwith stainer and connecting pieces,jointing materials etc and connecting to water mains including cutting/grinding of existing water mains as per site requirement for insertion of water meter including taking down old unserviceable water meter complete all as specified and directed by Engr-in-charge. Make : Woltman/Dasmesh/Kranti/Kaycee/Kirloskar.
Taking down and lowering the serviceable/new column pipe by using borewell lifting mechanical crane including necessary lifting tools/accessories complete all as specified and as directed. Note : Supply of column pipe with collar shall be measured and paid separately under relevant items.)
Supply only borewell column pipe of 50 mm bore dia , heavy duty.
Heavy duty collar suitable for lowering GI Pipe of size 50 mm bore fixed in repairs.
Servicing of submersible pump set 5/7.5 HP capacity including replacing of impeller, guide rings, neck rings, IP bush, bolts & nuts and lathe work etc complete all as directed. Note : (a) Rewinding of motor if required will be measured and paid separately.(b) Quoted rate shall deemed to be included the cost of removing and refixing of motor before and after rewinding/servicing.
All as per item No 115 herein before but 5 HP capacity submersible Pump Set.
All as per item No 115 herein before but 12.5/15.0 HP capacity submersible Pump Set.
Rewinding of submersible motor of 5/7.5 HP capacity, 3 phase, with super enamelled PVC insulated copper winding wire including appropriate class of insulation to the existing class and testing on full load after complete re-installation to the satisfaction of Engr-in-Charge. Note : (a) Testing of submersible pump set to be carried out at MES Pump House without extra cost before installation into borewell.(b) Quoted rate shall deemed to be included the cost of removing and refixing of motor before and after rewinding/servicing.
All as per item No 118 here-in-above but 10.0 HP capacity submersible Pump Set.
All as per item No 118 here-in-above but 12.5/15.0 HP capacity submersible Pump Set.
Supply on Flat copper cable 3 core 4 Sqmm multistranded conductor for submersible pump fixed in repairs and testing complete. Make - FINILUX
Supply on Flat copper cable 3 core 6 Sqmm multistranded conductor for submersible pump fixed in repairs and testing complete. Make - FINILUX
Servicing of chlorination plant of any capcity and make of Motor ,nozzele and steerer including replacing of items are required for service condiations etc complete all as directed.
Supply only chlorination test kit including chlorination testing liquide as per site and as directed.
Water collecting from main water sump and testing from authorised water test Lab as per site and as directed.
Cleaning/desludging of raw sewage in under ground sump well up to the depth of 5 Mtr inclduing screening chamber and various sewage pumping installation by closing main incoming manhole and pumping out raw sewage to neat drain by using portabale non clog pump set, cleaning of raw sewage sump by manually or mechanically using (spl T&P such as movable sewage cleaning tanker) scrapping inside wall and bottom by steel wire bush to remove raw material and transport it to outside cantonment area for disposal at low lying area up to the distance of 10 Kms at his own arrangment where the sanitary hazard do not take place and as per guidelines of civil authority all as directed for disposal. Thereafter cleaning/washing of interior surface of UG sump using high grade bleaching powder and lime mixed water incl painting with two coat of cement based paint.
Cleaning/desludging of sewage treated water in under ground sump well up to the depth of 5 Mtr inclduing screening chamber and various sewage pumping installation by closing main incoming manhole and pumping out raw sewage to neat drain by using portabale non clog pump set, cleaning of raw sewage sump by manually or mechanically using (spl T&P such as movable sewage cleaning tanker) scrapping inside wall and bottom by steel wire bush to remove raw material and transport it to outside cantonment area for disposal at low lying area up to the distance of 10 Kms at his own arrangment where the sanitary hazard do not take place and as per guidelines of civil authority all as directed for disposal. Thereafter cleaning/washing of interior surface of UG sump using high grade bleaching powder and lime mixed water incl painting with two coat of cement based paint.
Supply only Air blower gear oil.
S&F in repair for Butterfly valve, non-rising type conforming to IS-14846, sutiable for 150 mm bore pipe consisting of SS spindle as per IS 6603, Cast iron Body, Dome & Wedge as per IS 210, greasy jute type gland packing, fasteners as per IS 1367, Natural rubber gasket, CI manual hand wheel etc complete double end flanged and drilled, of Class PN-1.0 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed. Make : Kirloskar / Venus / Shakti / Upadhyaya
All as srl Item no 129 here-in-above but of 100 mm dia complete. Make : Kirloskar / Venus / Shakti / Upadhyaya/BIR
All as srl Item no129 here-in-above but of 80 mm dia complete. Make : Kirloskar / Venus / Shakti / Upadhyaya/BIR
S&F in repair Cl swing check NRV conforming to IS-5312, sutiable for 150 mm bore pipe consisting Cast iron Body, door as per IS 210, Bronze body ring as per IS 318, natural rubber door face, hinge pin SS ASTM A276 type 410, fasteners as per IS 1367, Natural rubber gasket, etc complete double end flanged and drilled, of Class PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed. Make : Kirloskar / Venus / Shakti / Upadhyaya/BIR
All as srl Item no 132 here-in-above but of 80 mm dia complete Make : Kirloskar / Venus / Shakti / Upadhyaya/BIR
All as srl Item no 132 here-in-above but of 100 mm dia complete Make : Kirloskar / Venus / Shakti / Upadhyaya/BIR
M & L for painting after scraping of old dull paints from the surface by scretching by wire brushes of steel surface over width or girth such as MS pipes, CI pipe, valve, motor, pump dozer etc and applying two coats of synthetic enamed paint by painting brush as per colour code decided by Engineer-in Charge and writing MES/SM No of machinery on the following items :-(i) Pipe lines of size 80 mm to 200 mm dia including stairs,Gate and GI railing - 30RM (ii) LT Panel Board- 05 No (iii) Non clog submersibale pump/Centrifugal pump set with accessories etc - 04 No
M & L preparing and cleaning the joints of RCC pipe after removing existing treatment and applying leak proof cement compound (Dr Fix it) to stop the leakage RCC pipe upto 600mm dia and then apply a coat of cement base adhesive paint.
Testing of sewage effluent at the (inlet of raw sewage sump and equalization tank and out let of chlorine mixing tank) sampling and analysis to be carried out by NABL accredited authorized LAB per IS - 3025 for essential parameters such as BOD/COD Note: Sample of raw sewage & post treatment sewage water to be collected by contractor in presence of rep of accepting offrs and submitted result of the test.
Repair/dechoking of choked sewage lines at sewage treatement plant with the aid of clearing rod,Brush and heavy duty submersible pump of any Cap and testing the entire STP sewage line for choking for minimum period of 8 Hours and rectifying the defects noticed all as per directed and specified by Eng-in-Charge.(Work includes dismantling of any elbow,sluice valve and pipe line if found necessary for dechoking of pipe line and also assembling the same complete and necessary Items,dewatering of sewage ,cleaning etc)
Repairs to leakage with antitoxic chamical solvent to stop water leakage ( of approval company i.e pidilite after removing by mechanically scarifying the the surface for receiving the epoxy. The leakage surface shall completely be removed preferebly with brush before laying of coating alongwith scaffolding and labours safety arrangement complete all as specified and directed.
Supply only stable Calcium hypochloride Grade I,availabilty Chlorine 34 % min,Stability 1/15 Max,moisture 0.3% max etc all as per IS Make: Lion/ Shriram (DCM) or equivalent approved by GE
Removing old filter media complete (Quartz sand gravel and activated carbon in granular form) of size 1200mmto 1800mm sizes complete in layers or as specified by OEM and incl scraping the internal surfaces of sludge drying beds with wire brush,and cleaning with bleaching powder slurry, cleaning with fresh water including applying one coat of white wash on external surface of sludge drying bed and re-filling up with new filter media in layers all as per manufacturers recommendations/ existing incl testing and commissioning etc complete all as directed. Note: New filter media will be measured and paid separately under relevant SCh A item.
Supply only filter media complete Quartz sand gravel and activated carbon in granular form) of size 1200mmto 1800mm or as specified by OEM complete in layers as per existing
S&F in replacement fully automatic star delta motor starter with Spp with metel encloser suitable for 5 to 7.5 HP motor . Make:-GE / BCH /SIEMENS L&T / C&S / GE/ BCH
Servicing/Repair of Star delta starter of any capciity/make including checking the all electrical connections ,fuse, SPP,relays,contactor etc .Note: The quoted shall be inclusive of SPP and relays.
Servicing of any pump set 3 to 7.5 HP capacity including replacing of impeller, guide rings, neck rings, IP bush, bolts & nuts and lathe work etc complete all as directed. Note : (a) Rewinding of motor if required will be measured and paid separately.(b) Quoted rate shall deemed to be included the cost of removing and refixing of motor before and after rewinding/servicing.
M&L for dismantling the defective induction motor of any capacity/make/class of insulation from foundation bed, duly coupled with pump/compressor, trasnporting to workshop removing burnt out winding from stator/rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing DE /NDE bearings, insulation materials, varnishing , heating, complet painting of motor etc complete, re-assembling, testing and commissioning of 3 to 7KW capacity motors all as directed.
Supply and replace pressure gauge 0-10 kg/cm² ,4" dia internal glycerin filled including stop cock etc complete with necessary fittings incl disamntling old one all as directed. Make:- H-GURU /FIE BIG
Supply and replace pressure gauge 0-50 kg/cm² ,4" dia internal glycerin filled including stop cock etc complete with necessary fittings incl disamntling old one all as directed. Make:- H-GURU /FIE BIG
Supply on Flat copper cable 3 core 16 Sqmm multistranded conductor for submersible pump fixed in repairs and testing complete. Make - FINILUX
Taking down defective / unservicable electromagenetic treated water flow metre any size & type fixed in STP 300KLD & supply & fix new electromagnetic treated water flow metre with totalizer sensor meter with all built in accessories comprising : (i) Meter size - 65 mm (ii) Sensor Housing - Cast Aluminium Alloy (iii) Liner Material - Elastomer end connection ANSI 150# electrode (iv) Material - 361 SS (v) Metering tube material - stainless steel (vi) Envitomental Protection - IP 68/NEMA6, including necessary electrical wirings etc make as per existing one or as ordered complete all as directed.
navreet construction (BID ID -3098089)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .