Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹27.0 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder | |
| 2 | L-2₹29.0 L+₹1.0 L (3.71%)Rejected-AOC | L-2 | Rejected-AOC other than Lowest bidder | |
| 3 | L-3₹32.4 L+₹4.4 L (15.8%)Rejected-AOC 146 D POCKET B MAYUR VIHAR PHASE II DELHI 110091 EAST DELHI 110091 | EAST | DELHI | 110091 | L-3 | Rejected-AOC other than Lowest bidder | |
| 4 | L-4₹33.0 L+₹5.0 L (18.0%)Rejected-AOC 275 2 AJIT NAGAR UPPER GADIGARH AIR PORT ROAD JAMMU INDEX NO D 04 ADGNJ | JAMMU | JAMMU AND KASHMIR | 180001 | L-4 | Rejected-AOC other than Lowest bidder | |
| 5 | L-5₹33.6 L+₹5.6 L (20.0%)Rejected-AOC | L-5 | Rejected-AOC other than Lowest bidder |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
13 May 2023, 6:00 pmClosed
Lt Col Ram G
GE Kaluchak Pin-900673 C/O 56 APO
SPECIAL REPAIR TO ROOF TREATMENT, FALSE CEILING, DOOR, WINDOW, EARTHING, PUMPING WORK, WIRING AND ADDN ALTN OF ROOF FLOORING AND CONNECTED WORKS AT RATNUCHAK MIL STN UNDER GE KALUCHAK
2023_MES_589588_1
GE/KC/NIT-01/2023-24
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹76,000
Yes
16 Jun 2023
15 Apr 2023
20 May 2023
15 Apr 2023
13 May 2023
29 Apr 2023
15 Apr 2023 - 22 Apr 2023
Amount
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified & directed.
Machine cut kota stone slab flooring, 20-25 mm thick as per sample kept in GEs office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing laid over and including 20mm screed layer in cement mortar 1:6, complete all as specified & directed.
Machine cut marble tile, 20 mm thick as per sample kept in GEs office as in vertical surfaces such as skirting/dado etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing, laid over and including 10mm thick screed bed in cement mortar 1:4, complete all as specified & directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified and directed.
Glazed ceramic coloured tiles of size 450mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
Dismantling wall & ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified & directed.
Non asbestos 4mm thick board (classic) of size 600x600mm laid on and included GI snap grid frame work (Grid size 605x605mm) for false ceiling with powder coated GI angle of size 25x25mm, main runner ‘T’ of size 25 x 40mm, secondary runner ‘T’ of size 25x30mm suspended with 3mm GI wire with butterfly clips for levelling, complete all as specified & directed. Note : 1. Quoted rates are inclusive for making holes, cutting chassis and making good to existing walls in cement mortar 1:3 or PCC 1:2:4 type B-1 as per existing finish all as directed at site. 2. All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm.
Dismantling asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in as in ridges, hips, valley gutters, drip and straight flashings, fixed with self tapping screws, complete all as specified & directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each including cutting holes for taking out hold fast or dismantled brickwork and making good disturbed portion in cement mortar 1:3 or PCC 1:2:4 type B-1, complete all as specified & directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) n exc. 1.5 Sqm each including cutting holes for taking out hold fast or dismantled brickwork and making good disturbed portion in cement mortar 1:3 or PCC 1:2:4 type B-1, complete all as specified & directed.
Pressed steel frames of size 125mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, necessary welding for fixing of butt hinges of any size/any number, complete all as specified & directed. Note : PCC for filling of hollow portion shall be measured and paid for separately.
35mm thick factory made 2nd class hard wood (Sal/ Hollock) plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides.The size of rail and style as per IS–1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified & directed.
35mm thick 2nd class hard wood (Sal/Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I, complete all as specified & directed.
Factory made box type steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS sheet tube with double side shutters (Wire Gauged shutter and Glazed Shutter), side hung shutters with MS handles and MS stays dovetailed or welded including 02 nos MS Tower Bolt 150mm long for each leaf, 8 mm square guard bars at spacing as shown in drawings, MS flat iron frame work, MS hinges, tarred hold fast, PCC 1:2:4 type B1 as in bed of hold fast, 01 No. per leaf of stopper of 100mm size, one coat of red oxide zinc chrome primer etc, complete all as specified and shown as drawing No. CEPZ/TD-354/09 sheet 1/3 to 3/3. Note : a). Wire cloth and Sheet glass shall be measured and paid seprately under respective items. b). Rate of both type of shutters is inclusive in the quoted rate.
Steel ventilator with top hung shutter including hinges, steel peg stay, complete including one shop coat of red oxide zinc crome primer including taking down old unserviceable ventilator, complete all as specified & directed.
PCC 1:3:6 nominal mix, type C-0 using 12.5mm graded crushed stone aggregate as in filling of pressed steel door frames/chowkats and similar items, complete all as specified & directed.
3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads or glazing pins in metal frame in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
Mild steel galvanised wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, wire staples or beading etc, complete all as specified & directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted in openings as per specification and drawing shown in SSR Part-II, complete all as specified & directed.
Factory made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete all as specified & directed.
Extruded aluminium alloy handle, fabricated type, anodised, 150mm long, complete all as specified & directed.
Aluminium anodised, barrel tower bolt of extruded section and fixed, 200mm long, complete all as specified & directed.
300mm ordinary rat tail rod pattern door spring including roller and roller plate of mild steel and fixed to pressed steel frame / MS frame/ wooden chowkhats including necessary welding work etc where-ever required, complete all as specified & directed.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm, complete all as specifed & directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) with and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed, 300mm long, complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified & directed.
Rolled mild steel work in main and cross beams, hip and jack rafters; purlins where connected to comman rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, conforming to Fe-290 grade-E-165, complete all as specified & directed.
Mild steel framed work as in plates (plain or chequered) channels square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe-290 grade-E-165, complete all as specified & directed.
Mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, n exc 30cm long, diametre of neck in exc 12mm but n exc 20mm, complete all as specified & directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed.
RCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified & directed.
Use & waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc alo splays between floors and beams for rough finished surfaces of concrete, complete all as specified & directed.
TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specifed & directed.
15mm thick rendering in cement mortar 1:6 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
5mm thick rendering in cement mortar 1:4 over 10mm thick rendering in cement mortar 1:6 on brick or concrete surfaces using integral water proofing compound, surface finished even and smooth without using extra cement, complete all as specified & directed. Note : Integral water proofing compound shall be measured & paid for seperately under respective items.
Supply only integral water proofing compound, complete all as specifed & directed.
Preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of alkali-resistant priming paint over 2mm thick wall care putty, complete all as specified & directed.
Complete removal of existing treatment from old decorated plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of alkali-resistant priming paint over 2mm thick wall care putty, complete all as specified & directed.
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
Preparation of new or previously untreated wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified & directed.
Preparation of new plastered or concrete surfaces of walls, chajjas, facias, parapets etc and applying two coats of cement base paint over a coat of cement primer, complete all as specified & directed.
Complete removal of existing treatment from external wall surfaces, preparation of old plastered surfaces of wall and applying two coats of cement base paint, complete all as specified & directed.
Taking up or down steel tubing and connections 15mm bore, complete all as specifed & directed.
Taking up or down steel tubing and connections 20mm bore, complete all as specifed & directed.
Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Vitreous china wash down water closet (Pedestal pattern), coloured with ‘P’ or ‘S’ trap, plastic water closet seat cover, white, closed pattern with flat bottom, and mild steel chromium plated or aluminised hinging device, fixed with screws of suitable size including making connections to trap and to flush pipe, fixing flushing cistern etc. and making good to floors, fixed in repairs, complete all as specified & directed.
PVC valveless, syphonic action type flushing cistern, 10 litres capacity, plunger type, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long, complete all as specified & directed.
Angle valves, fancy type, chromium plated, cast copper alloy, 15mm bore screwed down, high pressure with capstan head, both ends screwed for iron pipe or for union etc., complete all as specifed & directed.
Chromium plated hand shower (Health Faucet) with with 8mm dia 1 meter long easy flex tube in chrome finish & wall hook, fixed in repairs, complete all as specified & directed.
Stop valves, 15mm bore, fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specifed & directed.
Bib tap, 15mm bore, fancy type, chromium plated , cast copper alloy with capstan head, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified.
Vitreous china wash hand basin, oval type, white, flat back of size 630x450mm with 32mm dia waste pipe, brass CP waste coupling 32mm dia with long screwed shank and fly nuts, chain and plug, porcelain stopper, fixed in black granite stone including cutting of size in granite, moulding of edges, complete all as specified & directed.
Viterous china urinal, bowl type flat back, size 465x355x265mm (minimum) white with grating and union for discharge pipe, complete including providing and fixing plugs, beding urinal against wall in cement mortar 1:2 securing urinal plugs with and including 60mm long brass screws, pointing around urinal back in cement, complete all as specified & directed.
PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified & directed.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered `Hot’ or `Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe of 15mm bore, fixed in repairs, complete all as specified & directed.
Stainless steel grating of 100mm size (square/round), male/female pattern with or without hole, fixed in nahani/floor traps with white/coloured cement, complete all as specified & directed.
PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, complete all as specified & directed.
PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls, complete all as specified & directed.
PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls, complete all as specified & directed.
PVC connections 15mm size with PTMT nuts of length 600mm, complete all as specified & directed.
110mm bore PVC (SWR) bends any radius with oval access door, complete all as specified & directed.
75mm bore PVC (SWR) bends any radius with oval access door, complete all as specified & directed.
PVC (SWR) vent cowl of size 110mm bore, complete all as specified & directed.
PVC (SWR) junction single (Single T) equal or unequal, 75mm bore with oval access door, fixed in repairs, complete all as specified & directed.
Soap dish, brass chromium plated, of size 100x60mm, fixed to walls with chromium plated screws, complete all as specified & directed.
Towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges with chromium plated brass screws & wooden/plastic cleats, complete all as specified & directed.
Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top), triple layered, hoisted & fixed in position of capacity 1000 ltrs including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for bore of pipe 25mm, making necessary arrangements for fixing of inlet, outlet, over flow pipe, wash out pipe etc, complete all as specified & directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 20mm, complete all as specified & directed.
20mm dia stainless steel curtain rod of 1mm wall thickness in one length as per door/window with stainless steel bracket & knob of suitable size, stops rollers etc, fixed in repairs, complete all as specified & directed.
Demolition of cement concrete (un-reinforced) of any description in any position not otherwise specifically provided for, complete all as specified & directed.
75mm thick PCC 1:3:6, nominal mix, type C2, using 40mm graded crushed stone aggregate as in plinth protection, surface finished even and smooth without using extra cement including forming and filling of joints 12mm wide with bituminous & sand 1:3 by weight, complete all as specified & directed.
75mm thick PCC 1:4:8 (nominal mix), type D-2 using 40mm graded crushed stone aggregate as in sub base of floor, complete all as specified & directed.
Screed bed or bedding layer of cement mortar 1:6, 15mm thick for laying floor finishes, complete all as specified & directed.
Precast designer coloured paver tiles (factory made rectified) of size 300mmx300mm x 25mm, top layer glazed made in any type of cement and pigment, in required patterns (compressive strength not less than 250 Kg per Sqcm) as approved by GE in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match, complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipe etc. n exc 10 sqm on plan in any type of soil and getting out, complete all as specified & directed.
PCC 1:4:8, nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Mild steel framed work as in compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc., conforming to Fe-290 grade-E-165, complete all as specified & directed.
Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface of roof tiles/concrete padding etc including grubbing up of tree roots, removing existing water tank of any capacity, refixing at same place after making necessary arrangements, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in padding on roof, for levelling of roof slab, finished even and fair, complete all as specified & directed.
5mm thick rendering in cement mortar 1:3 on concrete surfaces of chajjas, upward fascias, ceiling and similar items, surface finished even and smooth without using extra cement, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of walls including cornices, pilasters, chajjas, facias, parapets etc by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of cement base paint, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of ceiling by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying one coat of white wash, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of ceiling by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of oil emulsion distemper, complete all as specified & directed.
Complete removal of existing treatment from old decorated plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of alkali-resistant priming paint, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of walls including cornices, pilasters etc by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying one coat of weather proof exterior emulsion paint, complete all as specified & directed.
Mild steel framed work as in grills, gratings, etc. with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 grade-E-165, complete all as specified & directed.
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
Taking down carefully unserviceable main switche fuse unit, distribution boards of any type/size from their position including making good to disturbed surfaces of wall etc, complete all as specified & directed.
Taking down carefully existing sub main wiring with aluminium conductor/copper conductor cable of any size with GI earth wire including wooden batten etc and making good disturbed surface of walls etc, complete all as specified & directed.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch using proper colour coding, complete all as specified & directed.
All as per Srl item No. 100 above but for one 3/5 pin 6 Amps socket outlet on same board.
All as per Srl item No. 100 here-in-before but for one 3/5 pin 6 Amps socket outlet on independent board.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 2.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 2.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 15/16 Amps independent using proper colour coding, complete all as specified & directed.
Switch piano flush type 5 Amps 240 volt, single pole one way, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5/6 Amp, flush type universal, 240 volt, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 6 & 15/16 Amp, 240 Volt, flush type universal, complete all as specified & directed.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, 240 Volt, complete all as specified & directed.
Electronic fan regulator, 2 module, 120watt, (5 stepped type), 240 Volt for 1200/1400mm sweep AC ceiling fan, complete all as specified & directed.
Tube light fitting integrated type suitable for LED 20W (4 feet) indoor, decorative aluminium extruded T5 LED batten complete with housing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified & directed.
LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size 23/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified & directed.
Factory made epoxy powder coated distribution board, SPN, 8 ways with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
Factory made epoxy powder coated distribution board, SPN, 4 ways with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
Factory made epoxy powder coated distribution board vertical type, VTPN, 4 ways with metal double door (IP-43 protection) confirming to IS : 8623, fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 200 Amp copper bus bar, neutral bar, standard DIN rail, earth bar, cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one MCCB 63/100/160 Amp 4P as incomer and MCBs SP/TP as outgoing, complete all as specified & directed.
MCCB of capacity 100 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, ATM (Thermal magnetic release), adjustable overload 80-100%, adjustable short circuit 5-10 In, complete all as specified & directed.
MCB, single pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
MCB, SPN, 63 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
Sub main wiring using uniform coding of wiring with two runs of 4 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn into and including PVC concealed conduit 'ISI marked' of 25mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required with all fittings and fixing accessories & one run of 4 Sqmm FRLS PVC insulated solid copper conductor for earth continuity wire in green colour, complete all as specified & directed. Note:- Two runs of copper conductor 4 sqmm and one run of 4 Sqmm copper earth wire including PVC conduit of 25mm dia will be measured and paid as one unit only.
Sub main wiring using uniform coding of wiring with two runs of 6 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn into and including PVC concealed conduit 'ISI marked' of 25mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required with all fittings and fixing accessories & one run of 6 Sqmm FRLS PVC insulated solid copper conductor for earth continuity wire in green colour, complete all as specified & directed. Note:- Two runs of copper conductor 6 sqmm and one run of 6 Sqmm copper earth wire including PVC conduit of 25mm dia will be measured and paid as one unit only.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Supply, hanging and testing of 1200mm sweep, 230 volts, AC ceiling fans, BEE rated energy efficient ceiling fan conforming to IS:374-2019, having 3 blades alongwith copper wound stator (capacitor start) with minimum air delivery 210 cubic metre per minute, power consumption not more than 50 watt, top speed minimum 370 RPM or higher, speed control by 5 step electronic regulator including capacitor, down rod, canopy, making connection with three core flexiable copper cable of 1.50 Sqmm upto ceiling rose & taking down old unserviceable ceiling fan of any type/size from existing location and depositing in MES store, complete all as specified & directed.
Taking down carefully ceiling fans from any height of any sweep/ make /model after disconnecting electric connections, servicing, overhauling, greasing etc, preparation of old surfaces of ceiling fans and blades by scraping out old existing paint with the help of emery paper/ wire brush, filling the cavities and painting with two coats of white synthetic enamelled paint over a coat of red oxide zinc chrome primer with the help of spray machine including greasing, re-writing MES SL No with black paint in capital letters and replacement of defective components/ accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance, complete all as specified & directed.
Intergral LED security light luminaire 60W LED, 230 volts made up of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, luminaire efficacy >110 Lumens per Watt, Secondary optics for better light distribution, having two nos Potted driver (OEM) (one inbult and one spare potted driver) 4KV internal +10KV SPD, THD<10%, pf>0.95, mounted on & including GI bracket made out of 40mm bore medium grade pipe of 1.70m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer, making connection with PVC copper conductor cable of 1.5 sqmm, complete all as specified & directed.
Metallic exhaust fan, 300mm (12") sweep, single phase, 230 volts, 50 Hz AC, 1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings, complete with louvers and shutters, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable including cutting holes in existing brick walls for making opening for fixing of exhaust fan of 300mm sweep including grounting bolts/nuts and making good disturbed surface of walls using cement sand mortar 1:4, complete all as specified & directed.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Galvanised iron tube 40mm bore light grade (ISI marked) for cable protection to poles/ under floor/ under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified & directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
Sheet metal enclosures single pole and neutral earth enclouser with a two pin and earth plug and socket complete with one single pole MCB 20 amps, C curve, 10 KA, 240 volts, complete all as specified & directed.
MCCB of capacity 160 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 35 KA (minimum) or higher, ATM (Thermal magnetic release), adjustable overload 80-100%, adjustable short circuit 5-10 In, complete all as specified & directed.
MCB, SPN, 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
MCB, 415V, B curve, four pole, 40 to 100 Amp 10KA with and including DB complete with connectiing, testing and commissioning, complete all as specified & directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth strip 32x6mm size (up to 7.5m in length from earth plate) by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 50mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised steel strip of 32 x 6mm to connect earthpit to electrical equipment room, complete all as specified & directed.
All as per Srl item No. 100 here-in-before but for one light point controlled by two numbers two way switches.
Switch piano flush button 6 Amp single pole, two way, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
Bell push flush type, one way 6 Amps single pole one way, complete all as specified & directed.
Electronic bell, multi music, AC, 240 volts, single pole, complete all as specified & directed.
Factory made epoxy powder coated distribution board, SPN, 12 ways with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
MCB, SPN, 40 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
Taking down carefully electric meter of any description by disconnecting electrically and refixing the same in old or new location, complete all as specified & directed.
Supply, installation and testing of water heater storage type (Geyser), single phase 230V, 50Hz, 5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 25 Litre capacity, 2000Watt rated power, incoloy 800 glass coated heating element, inner tank coating of ferro glass powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up and fixing arrangement on wall including providing hole fastners - 04 Nos, hot & cold water metallic flexible pipes 15 mm bore of adequate length as provided by OEM or required at site - 2 Nos, non return valve 01 No and including necessary plumbing work, complete with integrated shock safe plug with all protection features as per OEM design and standard including takind down old unserviceable geyser, complete all as spcified & directed.
Cutting & screwing of existing water supply line of 15mm bore for alterations or additions (or lengthening screw on pipe to form connector) including testing after completion, complete all as specified & directed. (each cut measured)
Bib tap, 15mm bore, fancy type, chromium plated, long body with cup, cast copper alloy with capstan head, screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs, complete all as specified & directed.
Socket outlet, 5 pin type, 6 Amp, flush type, 240 Volt, complete all as specified & directed.
12mm thick perforated gypsum board for insulation and acoustic purposes, 60cm x60cm in size including aluminium snap grid work in ceiling made out of aluminium extruded section using aluminium angles of size 25x25x2mm thick fixed on wall with and wooden gutties including necessary cutting holes on existing wall and making good the disturbed surfaces main and cross aluminium tee of size 38.10x38.10x1.60mm thick @0.60m c/c with bulbed heads suspended with 5mm dia GI J'' hooks of length 75mm and 3mm dia GI wire etc complete with necessary cleats nuts bolts etc, complete all as specified & directed.
Pyramid constructions
AKSHAY CONSTRUCTION COMPANY
GENESIS INDIA
KAMAL CONSTRUCTION
M/S TRIKUTA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .