Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹22.9 L+₹4.5 L (24.6%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹26.0 L+₹7.6 L (41.7%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹27.7 L+₹9.3 L (50.9%)Rejected-Finance 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹28.6 L+₹10.3 L (56.0%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
27 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
REPAIR MAINT AND OVERHAULING OF LIGHTENING PROTECTION SYSTEM IN TECH AREA AT AF STN CHAKERI KANPUR
2020_MES_356461_1
8412/E8
Open Tender
Civil Works
Item Rate
184 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹74,000
15 Sept 2020
27 Jun 2020
3 Aug 2020
27 Jun 2020
27 Jul 2020
13 Jul 2020
60 days
Amount
Dismantling/taking down old unsv lightening conductors & material & labour for fixing lightening conductor assembly made out of GI pipe light grade of size 50 mm bore along with welded flange at one end & GI reducer socket 50 x 40mm at another end connected with GI pipe light grade of size 40 mm bore with one end GI reducer socket to connect air termination & connector for earth strip duly fixed with necessary nuts bolts & washers in PCC 1:2:4 type B0 30cm x 30cm x30cm complete all as specified and directed. Note : GI pipe 40/50mm & air temination shall be measured & paid separately under relevant items
Supply only GI pipe light grade of size 40 mm bore for erection of lightening conductor complete all as specified and directed.
Supply only GI pipe light grade of size 50 mm bore for erection of lightening conductor complete all as specified and directed.
Supply only air termination Aluminium rod 20mm dia, 300 mm long for lightening conductor complete all as specified and directed.
Supply & fixing for Aluminium strip 25 x 3.15 mm on wall/batten or recessed or buried in ground complete all as specified and directed.
All as per item No 5 but Copper strip 32 x 6 mm -do-.
All as per item No 5 but Copper strip 25 x 3 mm -do-.
Supply & fixing for GI strip 32x6mm on wall/batten or recessed or buried in ground complete all as specified and directed.
M&L for overlap jointing of addl requirements of copper / GI / Aluminium strips by making drilling holes 02 Nos with brass/GI nuts, bolts and lead washers complete all as specified and directed. Note -brazing is is required to be done when copper strip is used and welding for GI strips
Dismantling aluminium earthing/lightening conductor strip from wall/roof of bldg & refixing on porcelain insulators after grouting insulators on wall/roof with neccesory fixing arrangement (nuts, bolts & PCC work) complete all as specified and directed. Note : (i) Porcelain insulators shall be measured & paid separately under relevant items rate quoted.
Supply & Fixing porcelain insulator of required size not exceeding than 10 cm long with two nos hole each on both end for fixing properly with nuts & bolts on wall of buildings for separated to lightining conductor or earthing stirp from building complete all as specified and directed. Note : The distance between two insulators fixed on the wall not more than 1 mtr lenght.
M&L for testing of old earthing using calibrated earth tester & submitting result to engr -in -charge. Earthing which showing highe results valueas specified in IS rule and disconnetivity should be replaced with new earthing items are considered as below complete all as specified and directed:- Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 5 Kg) shall be carried out one day before the testing & the cost of the same shall deemed included in unit rate quoted.
M&L for painting on wall with synthetic enameled paint of black colour of 200 x 150 mm size and writing work for earth test result with date complete all as specified and directed.
Material and labour for making High conductive, Non corrosive,Maintenance Free yet Repairable Electro-Chemical - Gel earht pit suitable for Lightning Conductor application using earth enhancing compound ISOGEL of 20 kg kit, CPRI Tested 'ISOROD' of 3 inch dia, 8 ft long and 0.12 inch thick made of K type electrolytic copper with top removal gel filling cap, seepage holes, Stainless steel fasteners, HDP Lockable earht pit cover cum inspection/termination chamber and all required accessories including design modifications, to achieve the required earth termination rod resistance value of less then 1 ohms complete all as specified and directed. Note: 1. Earth work will be included in unit rate . 2. connecting strip for equipement of 32x6 mm copper up to 7.5 meter will be included in unit rate. 3. Test point to be made on insulation base i.e. porcelain insulator or mica sheet of 3 mm thick will be included in unit rates . If earth resistance value is found to be outside the permissible limits successful bidder shall do fresh earthing on his own expense.
Material and labour for providing the MS plate size 0.05 sqm of triangle /rectangular shape and oval shape to identify the earthing not less than 1.6 mm thick and angle iron 25x3 mm and 600mm height welded with plate and grouting vertically alongwith earthing pit with PCC block not less than 300x300x300 mm duly painted background with black colour and writing arial font with white colour the type of earthing i.e. Chemical earthing No.X /Copper earthing No.XX /Charcoal earthing No. XXX and Earthing Result in Ohm and date of testing,date of due date of testing complete all as specified and directed.
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 8 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 complete all as specified and directed.
M&L for providing new earthing for bldg complete with copper plate of size 600 x 600 x 3.0 mm with copper earth strip of size 25 x 3 mm and earth pit not less than 4.25 mtr deep below normal ground level with top edge earth of the plate not less than 3.50 mtr below normal ground level connected to copper strip (25 x 3 mm ) from earth plate to test point by means of brass bolts, nuts, check nuts and lead washers or copper riveted joint including char coal dust, common salt, funnel with wire-mesh, 20 mm dia light grade GI pipe for watering and 40 mm dia GI pipe light grade for protection of copper strip and excavation / earth work with PCC pit 1 : 3 : 6 type C2 using 40 mm graded stone aggregate and RCC cover of 40 mm thick with 1 : 2 : 4 type B-O using 12.5 mm graded stone aggregate reinforced with 6 mm dia mild steel round bar 75 mm C/C both way with two Nos 12 mm dia MS handle complete all as shown in electrical plate No 3 of SSR Part I, the rates includes testing charges also complete all as specified and directed.
M&L for provn of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.5M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification complete all as specified and directed..
Material and labour for earthing complete with copper plate electrode 90cm x 60cm x 5 mm thick buried directly in ground with top edge of plate not less than 4.5mtr deep below the normal ground level connected to copper strip 32 x 6mm copper strip as main earthing lead and connected and tinted copper bolt, nuts, check nuts ad washers besides braising at all joints and connected to earth test point all as shown on plate No 2 of SSR Part -I 2009 and including necessary excavation, earth work, returning filing, removal of extra soil etc, filing adequate qty of charcoal dust, common salt and MgSO4, PCC work (1:3:6) type C1 using 20mm graded stone aggregate for earth pit with 40 x 40 x6 mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B1 40mm thick cover reinforcement with 8mm TMT bar @ 75 C/C on both way with funnel with wire mesh and 50mm dia GI light grade for earth lead protection pipe and 40 mm dia GI medium grade for watering complete all as specified and directed. Note for item No 14 to 19 :- The excess requirement (if more than 7.5 Mtr) of GI wire /Aluminium strip /copper strip and their joints for connecting upto the test point will be measured and paid separately
Supply and fixing of GI pipe light grade of size 40 mm bore for laying in trenches/floors or walls including all fittings for fixing complete all as specified and directed.
M&L for cutting/boring of PCC / WBM / hard standing at a depth not more than 30 cm deep & 20 cm in breath and making good disturbed surfaces by using the new materials on cutting areas/ disturbed surfaces complete all as specified and directed.
Dismantling / taking down old rusted copper / GI / Al strip from any height or situation complete all as specified and directed.
M & L for repairing of broken earthing pits chamber with PCC (1:3:6) type C-1 with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, funnel with wire mesh for watering pipe including Painting with White cement colour (Red/Green/Yellow) of earthing pits of diffirent colour as per Earthing type (Chemical/Lightening Protection and Conventional ) complete all as specified and directed.
Material and labour for new earthing pit with PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 8 mm dia bar, 3 Nos. both way, funnel with wire mesh,water poring arrangement ,connecting main Earthing lead from Earthing pit to Test point /equipment all as shown in electrical plate No. 3 of SSR Pt-I, 2009 complete all as specified and directed. .
M & L for repairing of broken lightening arrestor PCC by providing new PCC grouting Plastic gulli on room and flange to be fixed with screw after dismentling complete PCC (1:3:6) type C-1 of size .150MMX600MMX600MM and above 150x300x300mm and rendering complete all as specified and directed.
M&L for cutting / boring of PCC/hard standing at a depth not more than 30 cm deep and 30 cm in breadth for passing earthing conductor and making good the disturbed surfaces with PCC (1:2:4) type B-0 or cement mortar (1:3) complete all as specified and directed.
Supply and fixing of GI pipe light grade of size 15 mm bore for laying in trenches/floors or walls including all fittings for fixing complete all as specified and directed.
M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe complete all as specified and directed.
Material and labour to provide the PVC Pipe heavy duty of 50 MM DIA size for the GI/ALU/Copper strip enabling crossing to the wall by providing such pipe for ensuring that the Strip will remain insulated from wall and filling up the remaining portion of PVC Pipe, Polyerethen Puff/ filler for protection of insects including boring of suitable hole as well as making good of disturbed surface and matching with existing colour with the help of putti /distemper of same colour complete all as specified and directed.
All as per item No. 29 but PVC PIPE 40 mm dia -do-
All as per item No. 29 but PVC PIPE 32 mm dia -do-
Material and labour for painting externally of earthing pit with White cement and mixing of colour (Red/Green/Yellow) of earthing pits of diffirent colour as per Earthing type (Chemical/Lightening Protection and Conventional ) complete all as specified and directed.
M&L for making High conductive, Non corrosive, Maint Free GI pipe earthing with earth pit suitable for Lighting conductor application using earth enhancing compound 3 inch dia, 8 fit long and .12 inch thick with top removal get filling cap seepage holes stainless steel fasteners, and all required accessories including design modification including connection with GI strip upto test point complete all as specified and directed.
PAWAN COOL CORPORATION
Bharat Sales Corporation
A.B.Enterprises
BHATIA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .